Our BUILT Substack Newsletter

Join 27,000+ others. Short, fascinating engineering & infrastructure posts.

Once per week

By Dr. DF Duvenhage

Seawater-pumped storage is an innovative form of hydroelectric energy storage that harnesses the power of seawater as the lower reservoir in a two-tiered energy storage system. This approach offers a compelling solution for storing and regulating electrical energy. In this article, we explore the working principle, historical context, commercial implementations, and critical criteria for site selection in seawater-pumped storage projects.

Working Principle

Seawater pumped storage operates on a fundamental principle of storing surplus electricity during periods of low demand by using it to pump seawater from a lower reservoir to an upper reservoir. When electricity is needed, the stored water is released, flowing downhill, and driving turbines to generate electricity. This reversible process helps balance the grid and is a crucial asset for grid stability and renewable energy integration.

Major components and sub-systems

These facilities consist of several essential components or sub-systems, each playing a unique role in the process. In this article, we delve into these key elements that make seawater-pumped storage a viable and promising technology.

1. Upper Reservoir

At the heart of a seawater-pumped storage plant lies the upper reservoir, typically situated at an elevated location. This reservoir serves as the storage vessel for seawater, holding it until electricity is needed. The upper reservoir is often constructed with a focus on sealing techniques to prevent leakage and minimize environmental impact.

2. Lower Reservoir

The lower reservoir, as the counterpart to the upper one, is located at a lower elevation. This body of water collects the seawater discharged from the upper reservoir when energy generation is required. The difference in elevation between the two reservoirs is crucial for the plant’s energy storage capacity.

3. Penstock

The penstock is essentially a large pipe or conduit that connects the upper and lower reservoirs. When energy needs to be generated, water from the upper reservoir flows through the penstock to the lower reservoir. The penstock is constructed with durability and water-tightness in mind to prevent leaks and energy loss.

4. Pump-Turbine

The pump-turbine is a versatile machine that serves a dual purpose in seawater-pumped storage. It can act as a pump to lift water from the lower reservoir to the upper reservoir when excess electricity is available. Conversely, it transforms into a turbine to generate electricity by allowing the water to flow back down when power demand surges. These pump-turbines are designed to efficiently convert hydraulic energy into electrical energy and vice versa.

5. Electric Generators and Motors

Connected to the pump-turbines are electric generators and motors. When the pump-turbine operates as a generator, it produces electrical energy that is then fed into the grid. In contrast, when serving as a motor, it consumes electrical energy to pump water back into the upper reservoir. This dynamic interplay helps regulate the grid and optimize energy use.

6. Control and Monitoring System

A control and monitoring system is the brains behind the operation. It orchestrates the switching between pump and turbine modes, adjusts water flow rates, and manages the overall performance of the plant. This system plays a crucial role in maintaining grid stability and ensuring efficient energy storage and retrieval.

7. Seawater Intake and Discharge Structures

These are the entry and exit points for seawater into and out of the plant. The seawater intake structure allows water from the ocean to enter the system, while the discharge structure releases water back into the sea. Proper design and location are essential to minimize environmental impact and ensure efficient seawater use.

Historical Milestones

The Okinawa Yanbaru Seawater Pumped Storage Power Station in Japan holds the distinction of being the world’s first seawater-pumped storage facility. Completed in 1999 at a cost of ¥3.2 billion, it boasted a maximum output of 30 MW. Unfortunately, despite its technological success, this pioneering project was not profitable due to unmet power demand predictions, leading to its dismantlement in July 2016.

Seawater infiltration and dispersion were among the main areas under examination during the testing period of the Okinawa Yanbaru Seawater Pumped Storage Power Station. The following findings were reported:

Overall, the findings from the Okinawa Yambaru seawater pumped storage power plant’s test phase have been encouraging. It demonstrated the feasibility of using seawater for energy storage, even in the face of adverse weather conditions. As the plant continues to operate and undergo further testing, its journey toward commercial viability remains on a promising trajectory.

Commercial Implementations

Currently, the Okinawa Yanbaru facility remains the sole operational seawater-pumped storage power station globally. However, proposals for similar projects have emerged, such as the 300 MW Lanai Pumped Storage Project in Hawaii and potential projects in Ireland. Nevertheless, seawater-based pumped storage projects remain relatively rare when compared to conventional hydroelectric options.

Site Selection Criteria

Choosing an appropriate site is a pivotal aspect of seawater-pumped storage development. Key considerations include:

  1. Topography and Geology: The local topography and geology play an essential role in determining the feasibility and cost-effectiveness of a project.
  2. Surplus Power Availability: The availability of surplus power for the pumping process, primarily during off-peak hours, is a critical factor. Without an excess supply of electricity, the facility’s operation may become unviable.
  3. Feasibility of Seawater Infiltration and Dispersion: Ensuring that seawater remains within the storage system without infiltrating or impacting the surrounding environment is crucial. Linings and monitoring systems may be necessary to prevent infiltration and assess dispersion effects.
  4. Cost and Economic Feasibility: The economic viability of seawater pumped storage depends on factors like electricity costs, construction expenses, and available financing.
  5. Demand for Power: A sufficient demand for electricity within the region is essential to justify the construction of seawater-pumped storage projects.
  6. Technical Challenges: Seawater-pumped storage projects present unique technical challenges, including combating saltwater corrosion and fouling by marine organisms.

Challenges

Using seawater in pumped storage systems (PSS) comes with a set of practical challenges, mainly of a technical nature, due to the potential for seawater leaks from the upper reservoir or penstock, which could lead to significant harm to the environment. It’s crucial to address these issues effectively. In this context, two key technical concerns need attention: firstly, ensuring a secure seal for the reservoir, and secondly, choosing materials that can resist corrosion when building the penstock.

Moreover, it’s important to consider the potential spread of seawater caused by wind across the upper reservoir’s surface. To combat corrosion, it’s equally important to use materials that can withstand it for all the equipment involved in the water movement, including pumps and turbines. When deciding where to place these pump/turbine stations and their intakes along the coast, a thorough assessment of the site’s extreme weather conditions must be part of the planning process.

Overlap with existing industries and technologies

Seawater-pumped storage plants, while cutting-edge and distinct in their purpose, share several fundamental components and systems with existing technologies from various industries. The commonalities between seawater-pumped storage and these established technologies open up exciting opportunities for knowledge transfer and the adoption of best practices. Let’s delve into the overlaps and how they can benefit the development and operation of seawater-pumped storage plants.

1. Desalination Intake Stations

Seawater-pumped storage plants rely on seawater as the working fluid, and desalination intake stations, which draw seawater for desalination processes, have mastered the art of seawater extraction. Techniques used in desalination intake stations can inform the design and location of seawater intake structures for pumped storage, ensuring efficiency and minimal environmental impact.

2. Power Plant Cooling Coastal Discharge Stations

Power plants along coastlines have their cooling water intake and discharge systems. These systems offer insights into the management of seawater flow and temperature control. Seawater-pumped storage plants can adopt cooling system practices to optimize the release of water back into the sea while considering its temperature impact on the marine ecosystem. A benefit of seawater pumped-storage plants is that their discharge does not include any change to the condition of the water itself, meaning that this potential impact is not major. Erosion around the discharge is, however, the main factor that must be considered, since the flow rates can be quite high, and likewise the resulting erosion risk.

3. In-Land Pumped-Storage Hydroelectric Power Plants

Traditional pumped-storage hydroelectric plants, although located inland, share common components with seawater-pumped storage plants. These include penstocks, turbines, generators, and control systems. Lessons learned from the operation and maintenance of inland pumped-storage plants can be readily applied to seawater counterparts. Obviously, this is said with cognizance of the fact that inland systems do not have to contend with adverse water quality since they operate with fresh surface water. It is therefore imperative that the necessary attention is placed on the substantially higher risk of corrosion and wear on these mechanical components operating. Luckily, there are adequate highly experienced engineers from the various heavy industries that need to face marine conditions, who will be able to apply their knowledge towards increasing the wear-resistance of these mechanical components.

4. Mooring Systems in the Oil and Gas Sector

The mooring systems used in the oil and gas industry for offshore platforms and vessels require robust engineering to withstand harsh marine conditions. Seawater-pumped storage plants are often located in the open sea, and insights from mooring systems can enhance the structural integrity and stability of the plant. While seawater-pumped storage plants are invariably located near to coastal areas, their intakes might have to be located further off-shore in order to address coastal erosion risks and impact on marine life. These mooring systems from the oil and gas sector can, therefore, be applied to such scenarios for seawater-pumped storage intakes, in order to capitalize on the existing pool of experience and proven approaches.

5. Environmental Impact Mitigation Techniques

Techniques to minimize environmental impacts, such as those employed in water withdrawal and discharge practices, can be shared across various sectors. Lessons learned in mitigating adverse effects on marine ecosystems can benefit seawater-pumped storage plants.

6. Material Selection and Corrosion Prevention

Materials and coatings used in various marine applications can inform choices for corrosion-resistant components in seawater-pumped storage. Innovations in material selection and anti-corrosion strategies from diverse industries can be integrated to extend the longevity of plant infrastructure. As mentioned earlier, freshwater poses a much lower risk of corrosion and fouling than of seawater. However, the use of seawater in cooling of power stations located near coastal areas, and the types of equipment used in these applications, can be easily applied to seawater-pumped storage plants. Seawater pumps, piping, fittings, and operations and maintenance technicals from such cooling plants can be almost directly applied.

Opportunities for South Africa

Seawater-pumped storage power plants have the potential to provide a reliable and cost-effective solution to South Africa’s energy crisis. The country has been experiencing load shedding due to a shortage of electricity supply, and the increasing large-scale renewable energy generation has created a need for energy storage. The occurrence of inland pumped-storage and hydroelectric power plants in South Africa can provide a foundation for the development of seawater pumped-storage power plants. The metropolitan areas in the Western Cape, Eastern Cape, and KwaZulu Natal provinces are ideal locations for seawater-pumped storage power plants due to their proximity to the coastline.

Figure X shows a Digital Elevation Model Topographical Map of South Africa. This shows the elevation above sea level in meters, at a resolution of 30m2. It is quite clear that the highest elevations are located inland. However, there are various coastal regions where there are sharp elevation changes from 0m above sea level to more than 500m.

A Digital Elevation Model Topographical Map of South Africa

Figure X: A Digital Elevation Model Topographical Map of South Africa, https://en-za.topographic-map.com/map-6m7zs/South-Africa/

Considering the greater Cape Town metropolitan area in the Western Cape, shown in Figure Y, a few potential locations can be identified. These points are indicated, along with their elevations in Figure Y. Knowing nothing else, and assuming a similar flow rate to that of the Okinawa Yanbaru Seawater Pumped Storage Power Station of 26m3/s, we can estimate the potential installed capacity of pumped-storage plants located at these points based on the following calculations.

The hydraulic power formula calculates the rate at which water is flowing and the power it carries. It’s calculated as:

P=Q∗ρ∗g∗h*η

Where:

Knowing the elevations above sea level, and assuming a full cycle conversion efficiency of 75% (https://www.eskom.co.za/wp-content/uploads/2022/04/HY-0002-Palmiet-Technical-Brochure-Rev-11.pdf),  we can estimate the potential installed capacity for each location as:

A Digital Elevation Model Topographical Map of the Cape Town metropolitan area

Figure Y: A Digital Elevation Model Topographical Map of the Cape Town metropolitan area, https://en-za.topographic-map.com/map-6m7zs/South-Africa/

While these installed capacities are obviously much larger than even the installed capacity of the entire South Africa, they neglect a key factor; the area available at that elevation to construct the upper reservoir. A storage area is needed where a dam can be constructed using the terrain, or where engineered water storage can be built in the form of a concrete dam or metal tanks. In order to estimate the volume, and subsequently the footprint of flat surface area, needed for such storage, the formula for gravitational potential energy can be used and is defined as:

GPE=m∗g∗h

Where:

Furthermore, the volume can be calculated from the mass of water if the shape of the reservoir is pre-determined. If we assume a reservoir height of 15m, we can determine for various standard-shaped reservoirs, what the footprints need to be for various storage capacities in MWhs.

Capture

Clearly, this complicates the identification of locations for seawater-pumped storage. However, this does not mean that there is no potential for its implementation.

Conclusion

By recognizing these overlapping technologies and sharing best practices, seawater-pumped storage can benefit from the collective knowledge of established industries. This cross-pollination of ideas can lead to improved efficiency, enhanced environmental responsibility, and reduced development costs. As we strive for sustainable energy solutions, harnessing the collective wisdom of multiple sectors can play a pivotal role in the success of seawater-pumped storage and other innovative technologies.

The feasibility of such projects depends on several factors, including topography, geology, hydrology, and in the case of inland pumped storage, the availability of freshwater resources. However, some countries with mountainous landscapes, such as Switzerland and South Africa, have been successful in deploying inland pumped storage systems. The availability of seawater allows for larger and more economical schemes without the need to use valuable and limited freshwater resources. However, the capital costs of seawater-pumped storage plants can be high, and the feasibility of seawater infiltration and dispersion at the upper reservoir must be assessed in detail. Overall, the feasibility of seawater-pumped storage power projects depends on a comprehensive assessment of various factors, including topography, geology, hydrology, and the availability of adequate transmission networks.

Our BUILT Substack Newsletter

Join 27,000+ others. Short, fascinating engineering & infrastructure posts.

Once per week

By DR. DF Duvenhage

 1. Renewable energy technologies, an overview.

Renewable energy technologies are those that can be used to produce energy from direct and indirect effects on the Earth from the sun’s energy. These technologies include solar, wind, hydro, geothermal, ocean, and biomass[1]. According to the International Energy Agency (IEA), renewable energy supply from solar, wind, hydro, geothermal, and ocean rose by close to 8% in 2022, representing a substantial increase in the share of these technologies in total global energy supply[2]. Renewable energy is now a commercially attractive investment opportunity in many countries, with new solar photovoltaic (PV) and wind energy plants being more profitable than fossil and nuclear plants in a fast-growing number of regions around the world[3].

Renewable energy sources have been used to generate heat and power for much of human history, and more recently, electricity. Renewable energy makes up 12% of primary energy use in the United States and 11% worldwide[4]. In 2020, renewable energy sources generated a record 834 billion kilowatt-hours (kWh) of electricity or about 21% of all the electricity generated in the United States. Renewables surpassed both nuclear and coal for the first time on record[5].

The major types of renewable energy sources are biomass, hydropower, geothermal, wind, and solar. Biomass is organic material that comes from plants and animals, and it can be used to produce electricity, transportation fuels, and chemicals. Hydropower uses the energy of falling water to generate electricity. Geothermal energy is heat from the Earth’s core that can be used to generate electricity or heat buildings. Wind energy uses the power of the wind to generate electricity. Solar energy uses the sun’s energy to generate electricity or heat buildings[6].

Renewable energy technologies are at different stages of commercialization. The IEA has defined three generations of renewable energy technologies, reaching back over 100 years. First-generation technologies include hydropower, biomass combustion, geothermal power, and heat. Second-generation technologies include solar heating and cooling, wind power, modern forms of bioenergy, and solar photovoltaics. Third-generation technologies are still under development and include advanced biomass gasification, biorefinery technologies, hot-dry-rock geothermal power, and ocean energy[7].

Renewable energy can help fill the gap in energy needs, even if we had an unlimited supply of fossil fuels, using renewable energy is better for the environment. Renewable energy technologies produce few if any greenhouse gas emissions and have numerous benefits, including job creation throughout renewable energy industries, reduced emissions and air pollution from energy production, increased energy independence, and expanded clean energy access for non-grid-connected or remote communities[8].

 2. CSP, and how it fills a significant gap.

Renewable energy sources such as solar and wind are variable in nature, meaning that their energy production fluctuates depending on weather conditions. This variability can pose challenges for grid stability and energy storage. One technology that can address these limitations is concentrating solar power (CSP).

CSP systems use mirrors to concentrate sunlight onto a receiver, which creates heat that is used to generate electricity. The benefit of CSP’s exploitation of the thermal component of solar irradiation is that the energy can be stored as heat, or thermal energy storage (TES), which provides a workable solution to the challenge of reduced or curtailed energy production when the sun sets or during periods of weather-related intermittency[9]. CSP systems can store thermal energy for many hours, which enables them to be flexible and dispatchable options for providing clean, renewable energy[10]. CSP can provide power grid stability and flexibility, making it a valuable asset as grid demands evolve[11],[12].

Additionally, CSP can provide inertia, which is the kinetic energy stored in spinning generators and is useful in handling transient conditions such as temporary short circuits and momentary disruptions. This inertia is especially useful for low-frequency control[13]. CSP has the potential to reduce the cost of renewable energy from various sources and provide a reliable source of clean energy[14].

 3. An overview of CSP technologies.

CSP utilizes three alternative technological approaches: Parabolic Trough (PT), power or solar tower (ST), and dish/engine[15]. CSP systems use mirrors or lenses to concentrate sunlight onto a receiver, which creates heat that is used to generate electricity.

The ideal conditions required for the economic feasibility of CSP include areas of high solar radiation, low humidity, and minimal dust and clouds. These factors affect the amount and quality of sunlight that reaches the receiver, and thus the thermal energy output. The availability of land, water, grid connection, and environmental impact should also be considered[16].

Countries with CSP in operation and under development include Algeria, Australia, Canada, Chile, China, Denmark, Egypt, France, India, Italy, Mexico, Morocco, South Africa, Spain, Ukraine, the United Arab Emirates, the United Kingdom, and the United States[17].

Parabolic Trough Systems:

Fundamental PT power plant layout

Figure 1: Fundamental PT power plant layout, Adapted from http://energy.gov/eere/energybasics

Parabolic trough linear concentrating systems are used in one of the longest-operating solar thermal power facilities in the world, the Solar Energy Generating System (SEGS) located in the Mojave Desert in California. The facility has had nine separate plants over time, with the first plant in the system, SEGS I, operating from 1984 to 2015, and the second, SEGS II, operating from 1985 to 2015[18]. Parabolic trough systems are commercially mature and have been in operation for over 30 years. They have a lower cost per unit of capacity than power tower systems[19].

Solar irradiance is concentrated by long, curved reflectors onto collector tubes spanning the length of the parabolic troughs. These reflectors consist of a reflective material (such as mirrors or polished metals) that has been bent and orientated to reflect the sunlight onto a focal line [20]. The collectors consist of a glass outer tube, a high-conductance, a coated metal tube filled with a heat transfer fluid (HTF), and a vacuum between the two tubes. The selective coating on the metal tube allows high radiation absorption from the mirrors and limits heat loss due to the emission of infrared radiation from its surface[21].

The HTF within the metal tubes at current PT power plants that are operational or under development are either synthetic oils, molten salts, or steam (water). In the case of using an HTF other than water, heat is exchanged within a boiler, between the HTF and water, to produce high-temperature, high-pressure steam. In the case of direct steam generation, water is cycled through the metal tubes, producing the critical steam[22]. Finally, the steam drives a conventional Rankine-cycle turbine and generator and is condensed either by wet-, dry- or hybrid cooling.

The PTs within the solar field are modular and are arranged in long parallel rows. The structures on which the reflectors and collectors are mounted, in the solar field, track the sun on one axis only. They are aligned in a North-South orientation and track the sun from East to West throughout the day[23]. The HTF must be circulated through the entire solar field, hence they can reach great lengths. This results in the HTF having to be pumped kilometres before reaching the power block where it can exchange heat with water, generate steam, and drive the turbine and generator[24]. As a result of this fact, PT power plants generally need to be located in areas that are not steep and are near flat. This is another key difference between PT and ST technologies.

The temperature of the heat transfer fluid flowing through the pipe, usually thermal oil, is increased from 293ºC to 393ºC, and the heat energy is then used in the thermal power block to generate electricity in a conventional steam generator.

Power Tower Systems:

Fundamental ST power plant layout

Figure 2: Fundamental ST power plant layout, Adapted from http://energy.gov/eere/energybasics

Solar tower power plants also make use of the basic Rankine cycle for energy generation from steam. The key difference between it and PT plants is that the solar irradiance is concentrated by many mirrors in a solar field onto a single point. These mirror structures are called heliostats and track the sun on both the vertical (tilting)- and horizontal (rotating) axis[25]. They reflect and concentrate the sunlight onto a central receiver mounted on a tall tower. Here, the sunlight can be concentrated 600-1000 times, or more, resulting in temperatures in excess of 1000 degC[26].

The fact that the source of the heat is at a central location results in much less need for piping to transport the working fluid. The power block, storage, and condensers can all be located at the base of the tower, meaning that the working fluid does not have to be circulated for such long distances, as is the case with PT technology. The dual-axes tracking system required for the vast solar field is however more complicated than the single-axis system for PT power plants and requires more sensitive calibration.

The HTF used in ST power plants can also range between synthetic oils, molten salt or direct steam. In addition to these mediums, air can also be used as the working fluid because of the high temperatures reached[27]. If any medium other than water is used as the HTF, then heat must be exchanged between it and water to produce the steam required for the Rankine cycle. If direct steam is used, then the same principles as for PT power plants apply. The higher temperature, super-critical steam from ST power plants does however result in higher Rankine efficiencies. Beyond this fact lies the improvement in thermal storage capacity due to the higher temperatures since hotter molten salts can retain heat for longer periods[28].

Spain has several power tower systems. Planta Solar 10 and Planta Solar 20 are water/steam systems with capacities of 11 and 20 megawatts, respectively. Gemasolar, previously known as Solar Tres, produces nearly 20 megawatts of electricity and utilizes molten-salt thermal storage[29]. South Africa currently has two power towers; Khi Solar One, near Upington, and Redstone near Postmasburg. Khi, a 50MW direct-steam power tower, has been operating since 2017, while Redstone, a 100MW molten salt tower, is currently under construction. Power tower systems are less mature than parabolic trough systems, but they have the potential to achieve higher operating temperatures and efficiencies[30].

 4. Detailed breakdown of the underlying sub-systems of CSP.

The two CSP technologies that are suggested to be most applicable for large-scale baseload generation are comprised of different technological subsystems. Each subsystem, in turn, can employ different technology variations for the process it is involved in. The selection of subsystems depends on a variety of factors, most notably of which is maturity and the resulting bankability. Each different technology option for each subsystem leads to many possible configurations. There are certain physical and practical limitations to which technology options can be combined[31]. Furthermore, certain technologies require other specific technologies for the entire system to function successfully. Figure 3 shows the possible configurations based on the commercially available subsystem technologies.

From the diagram in Figure 3, it can be seen that there are a total of 36 different technology configurations for steam as a power block working fluid. It is clear that there are very few subsystem technologies that are limited to working in conjunction with other specific ones. Such is the case for molten salts as the working fluid, however, where it can only be used in conjunction with molten salt TES. CSP technology configurations are flexible, with synthetic oils, molten salts, and steam being compatible with HTF and TES combinations. There are however certain subsystem configurations that are preferred in the CSP industry due to their proven track records and maturity.

CSP subsystem technology combinations

Figure 3: CSP subsystem technology combinations

The individual subsystems that comprise a CSP plant each have their own purpose in the energy conversion cycle. There are various external factors that are considered before selecting a final total system configuration. The most important of these factors are the financial considerations, specifically, the tariff structure offered by the national utility or energy regulator[32].

The yield of the CSP plant will be chosen based on whether the tariff structure incentivizes baseload or peaking generation and the maximum limit on net capacity imposed by the energy regulator[33]. The tariff structure, on the other hand, depends on various complex national aspects, unique to each country’s respective economic, infrastructural, political, and social circumstances.

The most generic CSP power plant layout is given in Figure 4. It gives an indication of which technologies are applicable to which fundamental subsystem and how each subsystem affects certain characteristics of the final power plant. An indication of which resource impacts each subsystem will also be highlighted in order to briefly analyze the dependencies of each, and the total resource dependence of the entire power plant as a whole.

Generic CSP power plant layout Technology configurations

Figure 4: Generic CSP power plant layout – Technology configurations

From Figure 4, it becomes clear that the main resource involved with the operation of a CSP plant is water. Water is mainly used in the collector field, power block working fluid, and cooling subsystems, although it can also be used in the HTF and TES if direct steam generation and storage are selected. Generally, the uses of water in a CSP plant are threefold: collector field cleaning, make-up water for Rankine-cycle and HTF and TES if direct steam generation is used, and cooling of steam from Rankine-cycle.

            4.1. Parabolic trough – Solar Field

The solar field is the area where the mirrors or lenses are located that reflect and concentrate sunlight onto a receiver. The solar field is typically made up of hundreds or thousands of mirrors or lenses that track the sun throughout the day to maximize the amount of sunlight that is concentrated onto the receiver. The solar field is a critical component of a CSP plant, as it is responsible for capturing and concentrating the sun’s energy onto a receiver.

In the case of parabolic troughs, the solar field consists of parabolic-shaped mirrors. These track the sun in an east-west direction as the sun moves across the sky from sunrise to sunset. There are various designs for the parabolic trough frame and tracking system by different OEMs. However, the major components include the mirror support structure and frame, mirrors,

1Frame and Structure

  1. Frame and Structure:
  1. Mirrors (Reflectors):
  1. Rotating Assembly (Tracking Mechanism):
  1. Heat Collector Tube (Receiver Tube):
  1. Heat Transfer Fluid (HTF):
  1. Support Structure and Mounting Hardware:

            4.2.       Parabolic trough – Heat collectors/Receivers

The absorber tube is a critical component of a parabolic trough mirror-collector assembly in a CSP plant. It is responsible for collecting the concentrated sunlight and transferring the heat to the heat transfer fluid (HTF). The absorber tube is typically made of steel or glass and is coated with a selective coating to maximize the absorption of solar radiation[34]. The absorber tube has several sub-components, including the selective coating, expansion bellow, and HTF flow path.

The coating is designed to absorb as much solar radiation as possible while minimizing the amount of heat that is lost through radiation. The coating is typically made of a material with high absorptivity in the visible and near-infrared regions of the solar spectrum, such as black chrome or black nickel. The coating is also designed to have a low thermal emissivity, meaning it does not radiate heat away from the absorber tube as effectively as other materials. This helps to maximize the amount of heat that is transferred to the heat transfer fluid (HTF). The selective coating is a critical component of a parabolic trough CSP system, as it is responsible for maximizing the amount of solar energy that is collected and transferred to the HTF. The coating must be able to withstand high temperatures and vacuum conditions, as well as resist degradation from UV radiation and moisture.

            4.3. Parabolic trough – HTF system

The heat transfer fluid (HTF) system is responsible for transferring the heat from the absorber tubes to the power block.

The type of fluid used in the HTF system can vary, but it is typically a synthetic oil or molten salt that is heated in the receiver and then circulated through a series of pipes to transfer the heat to the power block[35]. The selection of the HTF is a crucial decision in designing a CSP plant. Common HTFs include synthetic oils (such as Therminol and Dowtherm) and molten salt (typically a mixture of sodium nitrate and potassium nitrate). The choice depends on various factors, including operating temperature, efficiency, cost, and system compatibility. Synthetic oils are often used in lower-temperature systems, which are currently the industry norm, while molten salt is favored for higher-temperature applications.

For molten salts, the eutectic mixture of sodium nitrate and potassium nitrate used in CSP plants typically freezes (solidifies) at approximately 220°C (428°F) and melts at approximately 288°C (550°F). These values represent the lowest freezing point and highest melting point for a mixture of these two salts in varying proportions. These properties make Solar Salt a suitable heat transfer fluid in CSP plants because it remains in a liquid state over a wide temperature range, allowing it to efficiently carry and transfer heat in the solar thermal system. The high melting point also ensures that it can withstand the high operating temperatures encountered in CSP applications without solidifying, which would disrupt the system’s operation.

However, the use of molten salt as the HTF results in an increased risk of freezing of the molten salt within the receiver tubes in the solar field, since this happens at around 200°C. Synthetic oils, however, such as Therminol and Dowtherm, are designed to operate within a temperature range typically spanning from approximately -20°C (-4°F) to 400°C (752°F) or even higher. This means that much less heat tracing is needed to ensure the HTF remains well above the freezing temperature, hence them being the more widely adopted HTF for parabolic trough CSP plants.

To minimize heat loss, piping is typically insulated with high-temperature insulation materials like mineral wool or aerogel. Proper insulation helps maintain the temperature of the HTF during transport, reducing energy losses.

Properly sizing the pipes is essential to maintain the required flow rates and minimize pressure drop. Larger pipes can reduce flow resistance and pressure losses, but they also increase material costs. Computational fluid dynamics (CFD) simulations are often used to optimize pipe sizing. Pressure drop in the piping network should be minimized to ensure efficient fluid circulation. This involves careful selection of pipe diameters, flow velocities, and the use of well-designed fittings and valves.

Given the temperature variations in CSP systems, the piping must accommodate thermal expansion and contraction. Expansion joints or flexible connections are used to prevent stress on the pipes and associated equipment. Expansion joints are typically made of materials that can withstand the temperature range and chemical compatibility with the HTF. Common materials include stainless steel, Inconel, or other high-temperature alloys. The bellows, the flexible component of the expansion joint, must be designed to accommodate the expected thermal expansion and contraction. The number of convolutions (the corrugated sections) and their geometry are critical factors.

Proper anchoring and support of expansion joints are essential to ensure they move as intended without imposing excessive stress on adjacent components. The design should allow for axial, lateral, and angular movement. Expansion joints must be designed to withstand the pressure and vacuum conditions of the HTF system. This is especially important if the CSP plant includes a thermal storage system, which can introduce varying pressure conditions.

Finally, an expansion tank is used to accommodate the expansion and contraction of the HTF as it heats up and cools down[36]. As the HTF heats up and expands, it would lead to a significant increase in pressure within the closed piping system if there were no means to accommodate this expansion. This overpressurization could potentially damage the piping, valves, and other components. Expansion tanks help protect the integrity of the HTF piping system by preventing stress and fatigue on the pipes, fittings, and other equipment. This reduces the risk of leaks, deformations, or failures caused by thermal cycling. The size of the expansion tank is determined by the volume of HTF that needs to be accommodated during thermal expansion. The design should consider the maximum expected temperature difference and the coefficient of thermal expansion of the HTF. To prevent overpressurization, expansion tanks often incorporate a pressure relief valve that opens if the pressure exceeds a certain threshold, allowing excess HTF to be released safely.

            4.4. Power Tower – Solar Field

At the heart of these power plants is the solar field array of heliostats, which plays a crucial role in concentrating sunlight onto a central receiver. Heliostats are mirror-like devices that track the sun’s movement on the horizontal and vertical axis to reflect sunlight onto a central receiver located atop a tower. These precision-engineered mirrors are the backbone of Power Tower CSP plants. They are designed to accurately follow the sun’s path throughout the day, ensuring maximum energy capture.

Picture8

Figure 6: Typical components of a Heliostat, http://www.powerfromthesun.net/Book/chapter10/chapter10.html.

  1. Mirror Modules: Mirror modules are the heart of heliostats. They are precision-engineered mirrors designed to efficiently capture and reflect sunlight toward the central receiver. These modules are typically constructed with high-performance glass or metal substrates, coated with a specialized reflective material, such as silver or aluminum. The choice of material is critical to achieving the highest possible reflectivity and durability. Mirror modules are engineered to withstand harsh environmental conditions, including wind, dust, and extreme temperatures, to ensure they maintain their reflective properties over the long term.
  2. Support Structure: Heliostat mirror modules are mounted on robust support frames, which are responsible for holding the mirrors securely in place and facilitating their precise movement. These support frames are typically made of durable materials like steel or aluminum, designed to provide stability and withstand mechanical stresses. The frames must allow for accurate alignment of the mirror modules and accommodate the range of motion required to track the sun’s position throughout the day.
  3. Torque Tube/Tracking Assembly: The Tracking Assembly serves as the backbone of the heliostat structure, connecting the support frame to the drive mechanism. The torque tube is engineered for durability and designed to minimize friction, allowing for smooth and precise tracking of the sun’s movement. Precision tracking is essential to keep the mirrors aligned with the sun. Heliostats use advanced tracking systems. Dual-axis trackers, such as those used in Heliostats, follow the sun’s east-west movement, as well as the sun’s north-south movement, to esnure as much sunlight is focussed on the central receiver at the top of the tower.
  4. Drive mechanism: The drive mechanism is responsible for adjusting the orientation of the heliostats in real-time to ensure that sunlight is continuously focused on the central receiver. Heliostats employ advanced tracking systems to precisely follow the sun’s path. These systems rely on motors, gears, and sensors to achieve high levels of accuracy, maximizing energy concentration at the central receiver. Typically, the sun’s path can be pre-programmed based on a series of geometric calculations considering the time of day, day of the year, the lattitude and longitude of the CSP plant, and the realtive position of the heliostat to the central receiver.
  5. Pilon: The pilon, also known as the pole or pedestal, is the structural support that connects the heliostat assembly to the ground. It plays a crucial role in ensuring the stability and safety of the heliostat array. Pilons are engineered to withstand the forces exerted on the heliostats, including wind loads and the weight of the mirror modules. The design and construction of pilons are critical considerations in the overall structural integrity of the solar field array.

            4.5. Power Tower – Heat Collector/absorber

The central position of the receiver offers a universal advantage to collect all energy at one location and save on transport networks. The central receiver system can be designed as either an external or cavity-type receiver. In an external receiver, the working fluid flows through tubes that are mounted on the outside of the receiver. In a cavity-type receiver, the concentrated solar radiation from reflectors incident into the cavity of the receiver through an aperture. The cavity-type receiver maximizes the capturing of sun rays and minimizes the radiative losses to the environment. The design of the central receiver system must take into consideration several factors, including the working temperature range, heat transfer efficiency, freezing protection, expansion and contraction, heat exchanger, control system, and working fluid. The type of fluid used in the central receiver system can vary, but it is typically a synthetic oil or molten salt that is heated in the receiver and then circulated through a series of pipes to transfer the heat to the power block.

A External Receiver Absorber B Cavity Receiver Absorber

Figure 7: A – External Receiver/Absorber, B – Cavity Receiver/Absorber
A – https://www.solarpaces.org/star-receiver-could-cut-tower-csp-cost-11/, B – Tiryaki, Gürcan & Camdali, Unal. (2017). ENERGY AND EXERGY ANALYSIS OF A SOLAR POWER TOWER SYSTEM WITH A CAVITY RECEIVER.

Absorber tubes are the core elements of the central receiver. They are an intricate network of tubes designed to capture concentrated sunlight. These tubes are typically made of materials like Inconel Alloy 625 / Haynes Alloy 230 with a black Pyromark 2500 coating, ensuring efficient heat absorption. The absorbed solar energy heats the molten salt circulating within the tubes, initiating the energy conversion process.

Inlet and outlet headers are essential components for the efficient circulation of the molten salt through the absorber tubes. The inlet header distributes the molten salt evenly to the absorber tubes, while the outlet header collects the heated molten salt , which has absorbed solar energy. These headers play a crucial role in maintaining uniform flow and heat distribution within the central receiver.

Molten salt circulation pumps circulate the primary heat transfer fluid (molten salt) through the solar receiver to heat it up and to either feed the solar steam generator, store the energy during the high sun radiation hours (cold salt pumps), or deliver it after the sunset (hot salt pumps). These pumps must be robust, capable of withstanding high temperatures, and designed for the specific properties of molten salt. Efficient circulation ensures that the captured thermal energy is effectively stored and later used to generate electricity.

            4.6. Boiler system

At the core of every CSP plant lies the power block, a complex system engineered to efficiently convert the captured thermal energy from solar concentration into electrical power. The Rankine cycle is the fundamental thermodynamic process underlying the power block’s operation. It constitutes a closed-loop cycle that facilitates the conversion of thermal energy into mechanical work and, subsequently, electrical power.

The Rankine cycle involves four principal stages: isentropic compression of the working fluid (typically steam), adiabatic expansion of the working fluid through a turbine, isobaric condensation of the working fluid in a condenser, and isentropic pumping of the working fluid. In CSP applications, the Rankine cycle is tailored to utilize the concentrated solar energy for heating the working fluid, thereby initiating the energy conversion process. The first step in this conversion process is exchanging the heat absorbed by the HTF (either synthetiic oils or molten salt) with water to generate steam.

At CSP plants, the boiler system stands as an essential facet of thermal energy conversion. It plays a critical role in harnessing and elevating the temperature of the working fluid to facilitate the Rankine cycle’s operation and ultimately produce electricity.

In the economizer, which is situated at the entrance of the boiler system, the residual heat in the exhaust gases from the steam turbine is used to preheat the incoming feedwater. This process significantly reduces the amount of thermal energy required to reach the desired working fluid temperature. By optimizing the use of exhaust heat, the economizer enhances overall plant efficiency.

The main boiler represents the core of the boiler system. Here, the pre-heated feedwater is turned into steam. This is done by exchanging heat between the HTF and the pre-heated feedwater in shell-and-tube heat axchangers.

The superheater is located downstream of the main boiler. Its role is to further elevate the temperature of the steam beyond its saturation point. This superheating process ensures that the steam remains in a vapor state throughout its passage through the Rankine cycle, preventing any condensation that may impair turbine efficiency. Superheated steam possesses increased energy content and is essential for driving the steam turbine efficiently.

Finally, in a two-tubeine system, a reheater may be used. In a conventional Rankine cycle, after the high-pressure steam exits the high-pressure turbine stage, it is directed to the condenser, where it is condensed back into a liquid. However, in some power plants, especially those with large turbines and high-pressure boilers, a re-heater is added to the cycle to enhance efficiency. The re-heater in the Rankine cycle increases the cycle’s efficiency by allowing for more energy extraction from the working fluid. It reduces the moisture content of the steam and prevents it from undergoing excessive expansion, improving overall turbine performance and power plant efficiency.

            4.7. Steam Turbine

Steam turbines in CSP plants play a pivotal role in converting concentrated solar thermal energy into mechanical work, which is then transformed into electricity. These turbines operate under unique conditions due to their dependence on solar heat as the primary energy source.

There are certain key characteristics of CSP plant steam turbines that differentiate them from those in coal-fired plants. Firstly, CSP plants typically operate at lower temperatures compared to coal-fired plants. The steam generated in CSP plants is at temperatures ranging from 250°C to 565°C (482°F to 1,049°F), depending on the specific technology used. This lower temperature range is a result of the limitations imposed by the concentrated solar heat source.

Furthermore, due to the lower temperature of the steam, CSP plant turbines operate at moderate pressure levels. The pressure in CSP turbines is usually lower than that in coal-fired turbines, which can reach much higher levels due to the significantly higher temperature of steam generated by burning coal. These lower temperatures and pressures in CSP plants can impact overall efficiency. To compensate, CSP plant designers often implement advanced technologies such as two-stage turbines or reheating to optimize energy extraction from the steam.

            4.8. Condenser

The condensing and cooling of the steam exiting the low-pressure turbine is critical to plant efficiency and operation. There are two major methods used for cooling at CSP plants: recirculating (evaporative) wet-cooling and dry-cooling[37].

Wet-cooling technology uses water as the cooling fluid, absorbing the latent heat of condensation from the steam exiting the low-pressure turbine. There are two types of wet-cooling technologies: (i) Once-through cooling- water is extracted from a source, used to cool the steam in a condenser and returned to the source to replenish the water abstraction, albeit with water at an elevated temperature. (ii)Recirculating, evaporative cooling, where cooling water is circulated between a cooling tower and a condenser, but the warm cooling water evaporates, forming water vapour in the atmosphere.

Once through and recirculating evaporative cooling

Figure 8: Once-through and recirculating evaporative cooling, https://doi.org/10.1016/j.renene.2018.08.033.

Once-through cooling has never been used for CSP because of the lack of adequate water resources in high DNI areas. Recirculating wet-cooling (hereafter referred to as wet-cooling only) is, however, very prevalent, with almost 80% of all operational plants using this cooling technology. This is due to the lower capital cost of wet-cooling technology and greater efficiency, compared to dry-cooling. Furthermore, compared to recirculating wet-cooling, the reduced efficiency of dry-cooling results in a larger solar field required to maintain the power output, at higher capital costs.

Wet-cooling is very effective because the heat from the steam is rejected to the air through the evaporation of the cooling water. Therefore, compared to dry-cooling, the wet-cooling process is less affected by variations in ambient air temperature,  since the evaporative cooling is dependent on wet bulb temperature. As a result of this, wet cooling uses almost 10 times more water than dry-cooling. There are two major mechanisms of water loss in wet-cooling. (i) Evaporative cooling of the warm water leaving the condenser in the cooling towers, as mentioned earlier, is the primary heat transfer method. This, in turn, results in the concentration of minerals each time water is lost to the atmosphere. (ii) In addition, dilution is required to prevent the cooling water from becoming saturated with minerals; which will result in scale formation and reduce cooling efficiency. Dilution is achieved by adding fresh cooling “makeup water”, and rejecting the higher concentration cooling water, known s “blowdown”, thereby continuously limiting mineral saturation and its consequences.

Dry-cooling, as mentioned before, does not use water as the cooling fluid, but air. Instead of the steam being cooled in a condenser by cooling water, it is cooled in what is called an air-cooled condenser (ACC). Here, the steam passes through a bundle of tubes, and ambient air is pulled (or pushed) through this to absorb the heat. This means that the effective cooling that can be achieved is dependent on the dry-bulb temperature of the air, which is always higher than the wet-bulb temperature in dry, arid conditions, where CSP is most prevalent. Dry cooling requires minimal water only for cleaning of the condenser tube bundles. This cleaning is carried out at fixed intervals to prevent external fouling on the tubes and ensure efficient operation. As discussed, the drawback of dry-cooling is its higher capital costs and negative impact on plant efficiency. In light of the fact that CSP is considered the most expensive RET, this extra addition to overall cost and levelised cost of electricity (LCOE) is a major limiting factor for its use at CSP plants. Another inherent drawback is that ambient temperatures are highest on days of high solar irradiation, resulting in the highest efficiency losses on days that are supposed to be the most productive.

            4.9. Thermal storage system

Thermal energy storage systems are the backbone of CSP plants, enabling the harnessing of solar energy even when the sun isn’t shining. These systems address the intermittency of solar energy, providing a stable and reliable power supply, day or night. TES systems store excess thermal energy generated during sunny periods and release it when needed, enhancing the dispatchability of CSP plants.

 Molten salt systems are among the most widely used TES technologies in CSP plants. They involve heating a mixture of sodium nitrate and potassium nitrate to a high temperature, usually around 565°C (1,049°F). The hot molten salt is stored in insulated tanks and can retain its heat for several hours, allowing for on-demand electricity generation.

Solid-state TES technologies involve the use of solid materials, such as ceramics or concrete, with high heat capacity to store thermal energy. These materials absorb and release heat during charging and discharging cycles, offering long-term storage solutions.

Pressurized steam storage is a TES technology that leverages high-pressure steam as the energy storage medium. It offers unique advantages and challenges compared to other TES systems, such as molten salt or thermal oil. During the charging phase, excess thermal energy generated by the CSP plant is used to heat water, creating high-pressure steam. The pressurized steam is then stored in specially designed tanks that can withstand the high pressure and prevent heat loss to the environment. When electricity generation is required, the stored high-pressure steam is released through a pressure reduction system. As the steam expands, it passes through a steam turbine, driving a generator to produce electricity.

An advantage of pressurized steam is its quick response, making this system responsive to grid demand fluctuations. Furthermore, unlike other TES systems that require a separate heat transfer fluid, pressurized steam storage uses water directly, simplifying the system. However, high-pressure steam systems may experience higher heat losses due to the greater temperature differences with the surroundings. The duration for which pressurized steam is also limited by the high pressures required and the losses that increase with larger storage vessels.

The two-tank molten salt storage system stands out as a reliable and efficient TES technology in CSP plants. This system comprises two separate tanks—one for storing hot molten salt and another for cold molten salt. During the charging phase (when excess thermal energy is available), hot molten salt from the solar field is pumped into the hot tank, where it is stored until needed. When electricity generation is required, the hot molten salt from the hot tank is circulated through a heat exchanger, transferring its thermal energy to a working fluid, typically water, to produce steam. The steam is then directed to a steam turbine for electricity generation.

After the hot molten salt has transferred its energy, it becomes cooler and is pumped back into the cold tank for reuse in subsequent cycles. This maintains a constant temperature differential between the two tanks, ensuring efficient energy storage and release. The two-tank molten salt system offers reliability and flexibility, allowing CSP plants to store energy for several hours or even into the night. Its ability to maintain consistent temperatures enhances overall system efficiency.

 5. Conclusion

Concentrating solar power offers a unique advantage over other renewables in the form of its capacity to store energy thermally. In recent projects, large solar photovoltaic plants have been built in conjunction with CSP in order to offset the higher capital costs associated with it and leverage the lower (and declining) costs of large-scale PV. This adds some complexity in the form of power electronics required for the high-voltage conversion of DC to AC electricity. Regardless of how CSP is paired with other renewables, its value lies in unlocking stable, dependable, clean energy from these technologies, since it can offer the baseload or dispatchable supply that weather-dependent PV and wind simply cannot offer. CSP offers a truly practical alternative to fossil-based energy supply while still utilizing many of the same sub-systems and components from these legacy generation technologies. In fact, CSP offers value to other industries in the form of process heat, which PV and wind can only offer by coupling them to inefficient heating cycles, resulting in energy losses. This is what makes CSP even more well-positioned than conventional renewables since CSP can not only offer a stable clean energy supply, but it can also benefit various sectors that rely on heat. One such sector is the fossil fuel sector itself, in the form of solar-enhanced oil recovery and process heat for refining and petrochemical products. This will be discussed in length in a follow-up article, building on the details covered in this introduction to concentrating solar power.

References

[1] https://www.sciencedirect.com/topics/engineering/renewable-energy-technologies

[2] https://www.iea.org/energy-system/renewables

[3] https://gggi.org/renewable-energy-is-now-a-commercially-attractive-investment-opportunity/

[4] https://guides.loc.gov/renewable-energy

[5] https://www.eia.gov/todayinenergy/detail.php?id=48896

[6] https://www.eia.gov/energyexplained/renewable-sources/

[7] https://en.wikipedia.org/wiki/Renewable_energy_commercialization

[8] https://www.energy.gov/eere/renewable-energy

[9] https://www.energy.gov/eere/solar/thermal-storage-system-concentrating-solar-thermal-power-basics

[10] https://www.bbvaopenmind.com/en/technology/innovation/pros-and-cons-concentrated-solar-power/

[11] https://www.energy.gov/eere/articles/concentrating-solar-power-could-provide-flexibility-and-reliability-us-electric-grid

[12] https://www.solarpaces.org/power-grid-stability-why-csp-could-replace-natural-gas/

[13] https://www.renewableenergyworld.com/baseload/grid-inertia-why-it-matters-in-a-renewable-world/

[14] https://www.utilitydive.com/news/cheapest-is-not-always-best-concentrated-solar-power-could-beat-lower-pric/574154/

[15] https://solareis.anl.gov/guide/solar/csp/

[16] https://www.mdpi.com/1996-1073/13/12/3258

[17]  https://solarpaces.nrel.gov/by-country

[18] https://www.eia.gov/energyexplained/solar/solar-thermal-power-plants.php

[19] https://www.nrel.gov/docs/fy04osti/34440.pdf

[20] https://www.irena.org/-/media/Files/IRENA/Agency/Publication/2012/RE_Technologies_Cost_Analysis-CSP.pdf

[21] https://iea.blob.core.windows.net/assets/663fabad-397e-4518-802f-7f1c94bc2076/csp_roadmap.pdf

[22] https://www.researchgate.net/publication/312368564_Concentrating_solar_power_a_review_of_the_technology

[23] https://www.irena.org/-/media/Files/IRENA/Agency/Publication/2012/RE_Technologies_Cost_Analysis-CSP.pdf

[24] https://www1.eere.energy.gov/ba/pba/pdfs/solar_trough.pdf

[25] https://www.irena.org/-/media/Files/IRENA/Agency/Publication/2012/RE_Technologies_Cost_Analysis-CSP.pdf

[26] https://www.researchgate.net/publication/312368564_Concentrating_solar_power_a_review_of_the_technology

[27] https://www.researchgate.net/publication/312368564_Concentrating_solar_power_a_review_of_the_technology

[28] https://www.sciencedirect.com/science/article/pii/S1876610215003525

[29] https://www.energy.gov/eere/solar/power-tower-system-concentrating-solar-thermal-power-basics

[30] https://www.nrel.gov/docs/fy04osti/34440.pdf

[31] https://www.nrel.gov/docs/fy16osti/65688.pdf?source=post_page—————————

[32] https://pubs.aip.org/aip/acp/article/1734/1/070031/997426/CSP-scenarios-in-South-Africa-Benefits-of-CSP-and

[33] https://pubs.aip.org/aip/acp/article/1734/1/070031/997426/CSP-scenarios-in-South-Africa-Benefits-of-CSP-and

[34] https://www.sciencedirect.com/topics/engineering/parabolic-trough

[35] https://www.sciencedirect.com/science/article/abs/pii/S0960148117304779

[36] https://labpartnering.org/technologies/abd3032b-408a-4d1e-b880-9d38387659a9

[37] https://netl.doe.gov/sites/default/files/netl-file/121-RptToCongress-EWwEIAcomments-FINAL.pdf

Our BUILT Substack Newsletter

Join 27,000+ others. Short, fascinating engineering & infrastructure posts.

Once per week

By DR. DF Duvenhage

Evaporative cooling towers serve as the workhorses of industrial and commercial cooling systems, utilizing the natural phenomenon of evaporation to achieve efficient heat transfer. While seemingly simple in concept, these towers rely on a complex interplay of thermodynamics, water chemistry, and mechanical components to deliver optimal performance. Ensuring their longevity and effective operation requires a proactive and comprehensive approach to maintenance. This guide delves into the key factors that influence the health and efficiency of evaporative cooling towers, empowering facility managers and engineers with the knowledge to optimize their systems and maximize their lifespan.

Cooling towers: a systems approach to maintenance

Cooling towers consist of a combination of sub-systems and components that must work together to cool a process fluid. These sub-systems vary in type, from static components like the cooling tower structure, fill, and basin to moving mechanical components such as the circulation pump (or pumps), fan motors and fans, and valves.

The tower structure, typically constructed from concrete, steel, or fiberglass, forms the foundational element upon which the entire system rests. Maintaining structural integrity is paramount, as compromised structural integrity can lead to costly downtime and potential water quality concerns. Regularly scheduled inspections and prompt repairs of any identified cracks or leaks are crucial for mitigating these risks.

Within the tower, the fill media, fabricated from PVC, polypropylene, or ceramic, maximizes the water-air contact area, thereby facilitating efficient heat exchange. Biofouling and scale buildup can significantly obstruct heat transfer, necessitating regular cleaning or, in severe cases, replacement. Implementing appropriate cleaning protocols and closely monitoring fill media conditions are essential for optimizing heat transfer efficiency and ensuring extended service life.

The basin, acting as the water reservoir, demands vigilant attention. Sedimentation and algae growth can disrupt water flow and harbor harmful bacteria. Periodic cleaning and maintaining optimal water chemistry through chemical feed systems and blowdown control are crucial for ensuring basin health and preventing water quality issues that could impact cooling performance.

The circulation pump, the tireless workhorse of the system, propels water throughout the tower. Monitoring its performance through flow rate and energy consumption measurements is critical. Preventive maintenance measures, such as bearing lubrication and seal replacements, guarantee smooth operation and prevent unplanned system stoppages.

The fan system, comprising powerful turbines that draw air through the tower, facilitates evaporation and heat removal. Optimal airflow and energy efficiency rely upon proper fan blade alignment, belt tension, and bearing lubrication. Vibration monitoring plays a vital role in proactively detecting potential imbalances before they escalate into costly breakdowns.

Finally, the intricate network of valves and piping regulates water flow throughout the system, ensuring balanced distribution and optimal performance. Leaks, even minor ones, can lead to water waste and compromise efficiency. Regular inspections and timely repairs are essential for maintaining system integrity and preventing water loss.

By implementing a component-level maintenance approach, facility managers can ensure each sub-system receives the targeted attention it deserves. This tailored strategy, meticulously addressing the specific needs of each element, safeguards the evaporative cooling tower’s longevity and peak performance, ensuring it continues to deliver its vital cooling function for years to come.

Water Chemistry Management

Water, being the lifeblood of evaporative cooling towers, can significantly influence their operational efficiency and structural integrity. The chemical composition of water directly affects the tower components, causing issues such as corrosion, scaling, and microbial growth. Corrosion, arising from the interaction between water and metal surfaces, can lead to structural damage and reduced system efficiency. Scaling occurs when minerals present in water precipitate and accumulate on heat exchange surfaces, hindering heat transfer and impeding water flow. Microbial growth, including the proliferation of bacteria and algae, not only compromises water quality but also accelerates corrosion and fouling.

The impact of water quality

The water flowing through an evaporative cooling tower acts as a dynamic chemical solution, with each dissolved ion, mineral, and gas playing a critical role in the system’s performance. Key parameters like pH, conductivity, hardness, and total dissolved solids (TDS) act as control variables, directly influencing heat transfer efficiency and material integrity. Maintaining optimal ranges for these parameters is crucial for sustained operation.

Water Treatment Strategies

To mitigate the adverse effects of water chemistry, various water treatment strategies are employed, each tailored to address specific challenges. Among these strategies, chemical treatment is a common approach. Corrosion inhibitors are added to the water to form a protective layer on metal surfaces, preventing corrosion. Scale inhibitors, on the other hand, disrupt mineral precipitation, keeping heat exchange surfaces free from scaling. Biocides are utilized to control microbial growth, safeguarding water quality and preventing the deterioration of tower components.

Additionally, physical water treatment methods such as filtration and softening are employed. Filtration removes impurities, suspended solids, and microorganisms, ensuring cleaner water circulation. Water softening involves the removal of calcium and magnesium ions, reducing the potential for scaling. An integrated approach often combines multiple treatment methods to comprehensively address water chemistry challenges.

The most common approach to water treatment on cooling towers is through the use of various chemicals to change the chemical composition of the water, thereby impacting the water’s ability to carry dissolved minerals, sustain biological life and cause corrosion of metal surfaces.

Chemical Dosing

There are three prominent families of chemicals dosed into evaporative cooling water circuits; corrosion inhibitors, scale inhibitors, and biocides or algaecides.

Corrosion inhibitors are an integral component of conventional chemical dosing strategies. These compounds are meticulously measured and injected into the cooling water to form a protective layer on metal surfaces, mitigating the corrosive effects of water chemistry. By creating a barrier between the metal components and the corrosive elements present in the water, corrosion inhibitors extend the life of the cooling tower, ensuring structural integrity and operational reliability. The precise control of the dosage is essential to strike a delicate balance between effective corrosion protection and avoiding excessive chemical buildup.

Scale inhibitors represent another crucial aspect of chemical dosing in cooling towers. As water evaporates and mineral concentrations increase, the potential for scale formation on heat exchange surfaces rises. Scale inhibitors, introduced in carefully calculated amounts, act to disrupt the crystallization process of minerals like calcium and magnesium, preventing the formation of scale deposits. This targeted approach not only preserves heat transfer efficiency but also reduces the frequency and intensity of maintenance activities related to descaling, contributing to long-term system reliability.

In microbiological control, biocides and algaecides assume a central role. The injection of these chemicals is meticulously regulated to curb the growth of bacteria, algae, and other microorganisms in the cooling water. Biocides act as microbial control agents, inhibiting the growth and propagation of harmful bacteria. Simultaneously, algaecides target algae, preventing their colonization and the formation of biofilms within the cooling tower. The precision in dosing these chemicals is crucial to balance effective microbial control and avoid developing resistant strains over time.

Chemical dosing in cooling towers necessitates a nuanced understanding of water chemistry, system dynamics, and the specific challenges posed by the operational environment. Precise measurements, guided by rigorous water analysis and system monitoring, enable engineers to tailor the chemical dosages to the unique conditions of each cooling tower. Regular adjustments and fine-tuning of chemical dosing regimes are imperative to accommodate variations in water quality, ambient conditions, and system load.

Blowdown

Conventional chemical dosing cannot be successfully implemented on a cooling tower without recognizing its limitations in preventing mineral scaling and adapting to the highly dynamic nature of the humid, variable-temperature environment inside a cooling circuit. Antiscalants are only effective at suppressing the water’s attempt to balance its composition through mineral precipitation up to a certain concentration of minerals. This is typically in the range of 650 to 1000 parts per million (PPM) TDS. Above this limit, the mineral reactions are too rapid for any amount of anti-scalants to prevent the species from forming their molecular bonds and precipitating.

Furthermore, the continuously changing environmental conditions and highly oxygenated, humid environment are a perfect breeding ground for algae, bacteria, and fungi. IF the dosing of biocides are not regulated with the changes in the bio-load of the cooling tower, it will not be able to suppress excessive growth or blooms from taking place.

Therefore, periodic purging of a portion of the concentrated circulating water is used to dilute impurities and restore equilibrium. It also adds relatively fresh, uncontaminated water into the system, usually from a municipal source that contains chlorine, which aids in preventing biological blooms from happening. The major drawback with blowdown, however, is that it is the purposeful dumping of water down a drain, resulting in further excessive water consumption by the cooling tower. Blowdown rate optimization by various means can help reduce water consumption and maximize system efficiency.

Membrane Filtration: Membrane filtration technologies, particularly reverse osmosis (RO) and nanofiltration, are both examples of precision water purification. These advanced technologies excel at selectively removing specific dissolved ions and molecules from the water, presenting an effective means of reducing the reliance on chemical treatment for water quality management.

Reverse osmosis and nanofiltration technologies are adept at delivering a high degree of water purification by leveraging semi-permeable membranes. These membranes act as molecular sieves, allowing water molecules to pass through while selectively rejecting dissolved impurities based on their size and charge. This process ensures a remarkable reduction in contaminants, including minerals, organic compounds, and particulate matter, contributing to the production of high-quality water for cooling tower applications.

However, the efficacy of these membrane filtration technologies comes with its own set of considerations. The concentrated effluent generated during the filtration process requires careful on-site management to prevent environmental impacts. Proper disposal or recycling of this concentrated brine stream is essential to maintain environmental sustainability. Additionally, the membranes employed in these technologies are susceptible to fouling, diminishing their effectiveness over time. To address this, anti-foulants are often introduced into the system to deter the accumulation of contaminants on the membrane surfaces, ensuring prolonged membrane life and sustained water purification efficiency.

One notable advantage of membrane filtration technologies is their capability to treat highly contaminated water supply sources, including borehole water or reclaimed process water. By effectively removing a wide range of impurities, these technologies enable cooling towers to operate with a cleaner and more reliable water source, mitigating the risk of scaling, corrosion, and microbial growth. This is particularly crucial in industrial settings where water quality variations can be substantial.

For less extreme filtration needs, more moderate solutions such as media filters come into play. Media filters operate on the principle of physical filtration, capturing suspended solids in the cooling tower basin water. By preventing these solids from reaching heat exchange surfaces and other critical components, media filters play a pivotal role in reducing fouling on cooling tower structures and equipment. While not as intricate as membrane filtration, media filters offer a practical and cost-effective means of maintaining water clarity and minimizing the impact of suspended solids on system performance.

Membrane filtration technologies, therefore, represent an effective option for addressing certain challenges in evaporative cooling tower water treatment. While these technologies offer unparalleled efficiency in removing specific contaminants, careful attention must be paid to the management of concentrated effluent and the prevention of membrane fouling. When applied judiciously, membrane filtration can revolutionize water quality management, providing a foundation for sustained cooling tower performance and longevity in diverse industrial applications. Their high initial costs, sensitive operational control, and impact on the site’s waste-water reticulation infrastructure, need to be considered in detail before they are implemented as a silver-bullet solution to all water treatment related problems.

Electrochemical Technologies: Within the realm of cutting-edge water treatment strategies for cooling towers, Electrochemical Technologies emerge as powerful tools harnessing the principles of electrolysis. Electrolysis, involving the introduction of an electric current through electrodes into a solution—water in this context—paves the way for highly localized alterations in water chemistry. This inherent capability is strategically employed to address three critical challenges in cooling tower water management: mineral scaling, corrosion, and biofouling.

Mineral scaling, a persistent concern in cooling tower systems, arises from the precipitation and deposition of minerals as water undergoes the evaporation process. Electrochemical technologies, by inducing controlled changes in the water chemistry, actively mitigate mineral scaling. The application of an electric current enables the dissolution of certain mineral deposits, preventing their accumulation on heat exchange surfaces. This targeted approach not only enhances the overall efficiency of heat transfer but also minimizes the need for traditional chemical scale inhibitors, reducing the environmental impact associated with chemical treatment.

Corrosion, a perennial threat to the structural integrity of cooling tower components, is effectively countered through the localized modifications facilitated by electrochemical technologies. By manipulating the electrochemical reactions at metal surfaces, these technologies create protective layers, thwarting corrosive processes. The result is an extended lifespan for critical components, reduced maintenance requirements, and enhanced overall reliability of the cooling tower system. This precision in addressing corrosion is particularly valuable in industries where metal components are exposed to challenging environmental conditions.

Biofouling, characterized by the uncontrolled growth of microorganisms such as bacteria and algae within cooling towers, is another challenge mitigated by Electrochemical Technologies. The introduction of an electric current disrupts the microbial environment, hindering the proliferation of harmful organisms. This targeted control not only preserves water quality but also minimizes the risk of fouling on heat exchange surfaces and other critical components. The reduction in biofouling not only enhances system performance but also contributes to energy efficiency by maintaining optimal heat transfer conditions.

While Electrochemical Technologies present a promising avenue for cooling tower water treatment, it is essential to tailor their application to specific system requirements and water chemistries. The controlled nature of electrolysis allows for customization based on the unique challenges posed by different cooling tower environments. Additionally, ongoing monitoring and adjustment of electrochemical parameters ensure that the technology remains effective over the long term.

Mechanical Maintenance

Moving Mechanical Equipment and Components.

The efficient operation of evaporative cooling towers hinges on the diligent upkeep of mechanical components. From the fan and fan motor to the pump and pump motor, along with valves, each element plays a pivotal role in ensuring optimal performance and longevity of the cooling tower system. Adopting comprehensive maintenance practices for these mechanical components is paramount for sustained reliability.

Implementing a proactive maintenance strategy for rotating equipment not only minimizes the risk of catastrophic failure but also optimizes cooling tower performance and efficiency. This translates to reduced operating costs, extended equipment lifespan, and ultimately, enhanced system reliability. By prioritizing the health of these critical components, engineers can ensure the cooling tower delivers its essential function flawlessly, maximizing operational effectiveness and contributing to overall plant efficiency.

Fan and Fan Motor Maintenance

The fan and motor assembly represents a critical component within the cooling tower system, directly impacting performance and operational costs. Regular and focused maintenance is essential to ensure optimal operation and prevent costly downtime.

Failure to address potential issues like bearing wear, belt misalignment, and debris accumulation can have significant consequences. Bearing wear leads to imbalances, inducing vibrations that stress the shaft, motor, and potentially the tower structure. Misaligned belts and pulleys decrease efficiency, translating to higher energy consumption and reduced heat transfer capacity. Additionally, clogged fan assemblies impede airflow, further compromising performance.

Of particular concern is motor failure, which can cause complete system shutdown, resulting in equipment damage and substantial downtime costs. A comprehensive maintenance program is crucial to mitigate these risks and ensure sustained reliability.

Recommended practices include:

Pump and Pump Motor Maintenance

The circulation pump and its associated motor are vital in ensuring efficient heat rejection by a cooling tower. Neglecting routine maintenance can lead to a cascade of detrimental effects. Bearing wear in the pump can induce imbalances, generating vibrations that stress the shaft and motor, potentially impacting pump performance and even compromising the tower’s structural integrity. Improper shaft alignment and seal degradation can contribute to internal leakage, reducing pump efficiency and increasing energy consumption. Furthermore, motor issues like winding insulation breakdown or bearing wear can trigger a complete system shutdown, resulting in significant operational downtime and associated costs.

Implementing a comprehensive maintenance program is paramount to mitigating these risks and ensuring sustained reliability. Key practices include:

While visual inspections of the pump components for signs of wear, leakage, or misalignment can be a cost-effective way to determine the equipment’s condition, continuous monitoring of key parameters is the most robust way to ensure system health. Vibration levels can be monitored to detect imbalances or bearing deterioration early. At the same time, monitoring discharge pressures and flow rates can ensure that the pump and motor are performing as required.

Following the manufacturer’s guidelines for motor inspections, cleaning, and preventive maintenance is always the best way to ensure effective operation and that its warranties remain valid. Monitoring motor winding temperatures is an effective way to ensure that the electrical motor is in a safe working condition.

The following items form the basis of effective maintenance on pumps and motors:

Valve Maintenance

In cooling tower systems, the strategic deployment of manual and control valves holds paramount significance in achieving operational efficiency and system integrity. The blowdown valve plays a critical role in maintaining water quality by facilitating the controlled discharge of concentrated and impurity-laden cooling water, preventing the accumulation of undesirable elements within the system. Proper adjustment of blowdown rates is imperative to maintain an optimal cycle of concentration and mitigate scaling, corrosion, and microbial growth. Improperly functioning or improperly set blowdown valves can lead to several detrimental consequences:

Conversely, the make-up valve regulates the introduction of fresh water into the system to compensate for losses due to evaporation, drift, and blowdown. Precision control of the make-up valve ensures that the cooling tower operates within specified parameters, preventing excessive water usage and conserving resources. Both valves, when appropriately sized, calibrated, and maintained, contribute to the longevity, efficiency, and environmental sustainability of cooling tower operations. Ineffective make-up control can also cause issues:

While blowdown and make-up valves play a critical role in cooling tower water management, numerous other manual valves serve diverse functions within the system. Each contributes to efficient operation and requires proper attention for optimal performance and longevity. Here’s a breakdown of some common manual valves and their maintenance needs:

Isolation Valves

These valves are used to isolate sections of the system for maintenance, repairs, or equipment replacement without shutting down the entire tower. Examples include isolation valves on pumps, heat exchangers, and bypass lines.Regular visual inspection for leaks, ensuring proper closure and opening, and periodic lubrication according to manufacturer’s recommendations are a minimum requirement for ensuring effective operation.

Drain Valves

These valves facilitate draining of the cooling tower basin or sections of the piping for maintenance, cleaning, or winterization.Regular inspections and testing wil help to ensure these valves are fully functional and free of debris, and replace worn gaskets or seals as needed.

Sample Valves

These valves are typically smaller in bore size and allow for collecting water samples for chemical analysis and monitoring water quality without affecting the operations of the cooling tower. It is important to ensure sterility and cleanliness of these valves to prevent contamination of samples that are taken from tehm.

General maintenance considerations for valves

Fill media inspection and cleaning

The fill media in evaporative cooling towers plays a pivotal role in facilitating efficient heat exchange and water evaporation. Implementing comprehensive maintenance practices is essential to ensure the sustained effectiveness of this crucial component. As such, regular visual inspections of fill media are fundamental to identifying early signs of fouling or degradation. Inspectors should look for deposits of scale, sediment, or biological growth that may impede water flow and compromise heat exchange efficiency. Conducting these inspections at scheduled intervals helps prevent the escalation of issues.

Fouling prevention is mainly managed through implementing water treatment programs, as discussed in previous sections, with the aim of reducing the accumulation of mineral deposits and suspended solids on fill media. A routine cleaning schedule based on water quality and tower usage, combined with regular inspections, will help to prevent fouling. High-pressure water jets or automated cleaning systems can effectively remove accumulated deposits. However, automated cleaning systems are expensive, as opposed to manual labor.

By establishing a proactive replacement schedule based on the expected lifespan of the fill media material, operational inefficiencies or loss of production can be avoided at relatively low costs. This helps prevent unexpected failures and downtime. Other than visual and physical inspections, it is possible to gauge the effectiveness of fill media by monitoring the performance of the cooling tower, including water temperature differentials and system efficiency. A decline in performance may indicate the need for replacement.

Water distribution system maintenance

The water distribution system in evaporative cooling towers is critical in ensuring efficient heat exchange and optimal cooling tower performance. In order to prevent issues such as uneven water distribution, scaling, and microbial fouling, it is necessary to consider this subsystem in any evaporative cooling tower maintenance strategy.

Once again, routine visual inspections of spray nozzles, pipes, and distribution basins are essential to identify potential issues promptly. These inspections should be conducted safely while the cooling tower is operational in order to evaluate spray patterns and water distribution across the fill or condenser tubes. Inspect for clogs in the piping due to scaling or damage that may impede water flow and compromise the uniform water distribution over the fill media.

Periodically clean and unclog spray nozzles to ensure an even and uniform water distribution over the fill surfaces. Furthermore, through a scheduled inspection and cleaning regime, it will be possible to replace damaged or worn-out spray nozzles in an effort to maintain proper water distribution patterns. If a nozzle is broken and a solid stream of water falls through a concentrated o[portion of the fill, heat rejection will be greatly compromised, and mineral scaling will be accelerated on certain fill areas. Additionally, by periodically calibrating and adjusting nozzles to ensure an even water distribution, dry spots or over-saturation on the fill media can be avoided.

It is critical to ensure the water distribution headers and nozzles receive the right water pressure to ensure that they fall within the specified operational range. While it is a common practice to adjust flow rates based on changes in system load or ambient conditions to optimize water usage without compromising thermal performance, deviating from the design flow rate can still exasperate other water-quality related matters such as mineral scaling through the formation of dry-spots that experience flash-evaporation.

Cooling Tower Structure

The structural integrity of evaporative cooling towers is a critical factor in their reliable and efficient operation. Structural components, including the tower’s framework, support structures, and associated elements, are susceptible to various forms of degradation, such as corrosion, erosion, and vibration-induced damage. Adopting a proactive approach to maintenance is paramount for safeguarding structural integrity. Once the structure of a cooling tower is compromised beyond a certain point, the only option is to replace the entire cooling tower. While the structure is a static component that is easily neglected, as opposed to moving components, it is the most crucial component for ensuring a long operational lifetime.

Corrosion is by far the most common and severe challenge faced by cooling tower structures. The humid and moist environment of a cooling tower is highly conducive to corrosion, a naturally occurring phenomenon that is not easily prevented. However, one approach is protecting the structure instead of outright avoiding corrosion. By applying protective coatings and paints to exposed metal surfaces, it is possible to create a barrier against corrosive elements. Regularly inspect and touch up coatings to address any areas of wear or damage. Furthermore, cathodic protection systems can be implemented to mitigate corrosion by controlling the galvanic reactions occurring on metal surfaces.

Addressing vibration-induced damage can arise in cooling towers due to the alignment of rotating components such as fans and motors. Misalignment can lead to vibration-induced damage and compromise the structural integrity of the entire system. It is, therefore, imperative to ensure that rotating components are properly balanced to prevent excessive vibration. Unbalanced components can accelerate wear and contribute to structural fatigue. Vibration monitoring is also a highly effective way to detect the development of misalignments on rotating equipment before it can cause damage.

As is the case with most aspects of maintenance, it is important to include routine inspections of the cooling tower structure condition. This includes visual inspections, measurements, and non-destructive testing methods to identify potential issues before they escalate. Maintain detailed records of inspections, noting any observed anomalies, corrective actions taken, and the condition of structural elements. This documentation serves as a valuable reference for trend analysis and decision-making. Furthermore, it is worth noting that a process plant should implement and communicate an emergency response plan to address unforeseen structural issues promptly. This plan should include shutdown procedures, temporary repairs, and contact information for relevant personnel.

Data-Driven Operational Optimization and Maintenance

In the era of Industry 4.0, data has emerged as a powerful tool in predictive maintenance strategies for many processes, including cooling towers. Monitoring key parameters such as water conductivity, pH levels, temperature, and corrosion rates allows for real-time insights into the condition of the cooling water. Advanced sensors and analytics enable early detection of deviations from optimal conditions, allowing engineers to implement timely interventions.

Preventative interventions based on data analysis include adjusting chemical dosages, initiating cleaning cycles, and scheduling maintenance activities. Proactive measures, guided by data, help prevent the onset of corrosion, scaling, and microbial growth, thereby extending the life of cooling tower components and enhancing overall system efficiency. Predictive modeling can further forecast potential issues, allowing engineers to plan and implement preventative measures before problems escalate.

By learning from historical data and identifying trends, we can predict equipment failures before they occur. This enables proactive maintenance interventions, maximizing equipment lifespan and minimizing downtime. Imagine replacing a bearing just-in-time, instead of scrambling after a costly shutdown. Deviations from normal operating ranges become early warning signs. A spike in vibration might indicate bearing wear, while a drop in flow rate could suggest a blocked pipe. Timely intervention based on these signals minimizes downtime and repair costs.

Real-time data reveals hidden inefficiencies. Advanced analytics identify correlations between variables, enabling optimization of fan speeds, pump operations, and chemical dosing based on actual conditions. This leads to reduced energy consumption, improved heat transfer, and lower water use.  The future of cooling tower optimization lies in its integration with broader process and building management systems through advanced communication and the Internet of Things (IoT). Such an interconnected ecosystem enables remote monitoring and control, where operators can monitor and adjust cooling tower performance from anywhere, leading to faster response times and improved operational efficiency. Furthermore, data from the cooling tower can be coupled with information from HVAC systems, lighting, and occupancy sensors to optimize overall building performance and energy use.

The list of parameters that can be monitored on an evaporative cooling tower can become endless, and one must always caution against “analysis paralysis”. As a guide to selecting the most important parameters for a specific application, the following should be considered.

Water Quality:

System Performance:

Environmental Conditions:

Additional Parameters (Depending on specific system setup):

By effectively combining real-time data with historical trends and analysis through machine learning unlocks the true potential for optimization and predictive maintenance. Implementing data-driven strategies requires investment in sensors, monitoring systems, and data analytics expertise, but the long-term benefits in terms of cost savings, efficiency, and reliability often outweigh the initial investment.

General considerations

Any maintenance strategy on any system or process equipment is only as effective as its implementation, documentation, and reporting. Maintain a log of maintenance performed on each piece of equipment, including dates, observations, and actions taken. Technicians should be trained to perform specific tasks safely and effectively, as well as in the thorough documentation and administration of the maintenance strategy as a whole. This documentation aids in trend analysis and decision-making for long-term maintenance strategies. Prioritize safety during maintenance activities, including proper lockout/tagout procedures and equipment shutdown protocols.

Conclusion:

Cooling towers are easily neglected as part of an overall plant-wide maintenance strategy. This is due to them rarely being at the core of whatever process they are servicing. Hence, they are considered part of the “utilities” of a process plant, like water and electricity supply. As a result, they are often overlooked, resulting in their steady, otherwise unobserved degradation and reduction in performance. Too often, this slow decay is only realized once it causes a problem in the core process itself, affecting plant performance, uptime, or safety.

By implementing a comprehensive maintenance program that addresses these key factors, facility managers and engineers can ensure the longevity, reliability, and peak performance of their evaporative cooling towers. This not only translates to cost savings through extended equipment life and reduced energy consumption but also safeguards the overall efficiency and sustainability of their cooling systems.

Our BUILT Substack Newsletter

Join 27,000+ others. Short, fascinating engineering & infrastructure posts.

Once per week

By DR. DF Duvenhage

1. Introduction: The Cornerstone of Optimal Cooling Tower Performance

Evaporative cooling, a well-established and effective method for removing heat from various systems, has been utilized for over half a century. Its popularity stems from its numerous advantages, chief among which is its superior heat rejection efficiency. Moreover, evaporative cooling systems are simple to operate and maintain, ensuring a relatively simple integration with other plant operations and systems.

At the heart of evaporative cooling lies a natural principle. In open-circuit cooling towers, water to be cooled is distributed over a fill pack while air is drawn or blown through the packing. A small portion of the water evaporates, effectively cooling the remaining water. The cooled water then falls into the tower’s sump, and the outgoing air stream carries away the heat extracted from the water.

Closed-circuit evaporative cooling towers, also known as evaporative condensers, employ a heat exchanger or coil within the tower instead of a fill pack. Water is circulated over the heat exchange coil, and heat is extracted from the refrigerant or primary fluid passing through the coil through the same evaporative process.

Evaporative cooling stands out for its remarkable combination of high thermal efficiency and cost-effectiveness. It achieves low cooling temperatures with minimal energy and water usage. These low cooling temperatures are crucial for many processes to achieve optimal system efficiency. By reducing energy consumption, evaporative cooling contributes to preserving natural resources and protecting the environment.

Evaporative cooling towers play a pivotal role in industrial and commercial applications by dissipating heat from various processes. Accurately sizing a cooling tower is crucial for ensuring it effectively meets the specific cooling demands of the application. Improper sizing can lead to a range of detrimental consequences, including:

The challenges faced in selecting the proper size cooling tower are relatively simple; however, ineffective sizing can cause various problems during operation if they are not carefully considered, as discussed above. A critical factor when sizing a cooling tower, which is easily over-simplified, is the seasonal variation in ambient conditions. If a cooling tower is sized for an annualised average condition, it may not be effective in the peak of summer or the dead of winter. Air temperature and humidity impact evaporative towers the most. They need to pull sufficient airflow in any condition, and the selected cooling tower must have enough surface area and soling water circulation rate to achieve that. Sizing your tower right for the extremes from the beginning is the best way to avoid this issue.

2. Understanding Cooling Load: The Foundation of Sizing

The primary factor governing cooling tower sizing is the cooling load, which represents the total amount of heat that the tower must remove from the system or process. Cooling load is typically measured in British thermal units per hour (Btu/h) or kilowatts (kW). Accurately determining the cooling load is essential for selecting the appropriate cooling tower size. The two units measure the same thing but are based on different historical approaches. However, 1 kW (1,000 watts) is equal to 3,412.14 Btu/h, and conversely, 1 Btu/h equates to 0.0002931 kW. Btu/h are typically used with empirical units, in America, while kW is used with metric units, in Europe and many other countries.

Selecting the appropriate size for an evaporative cooling tower requires careful analysis of four primary factors: heat load, range, approach, and wet-bulb temperature. Mastering these considerations ensures optimum cooling efficiency and avoids costly over- or under-sizing.

  1. Heat Load: Accurately determining the process heat load is paramount. Overestimating leads to unnecessary capital expenditure and energy consumption, while underestimating risks inadequate cooling. Standard engineering methods or manufacturer-provided tools can facilitate this calculation. The heat load that needs to be dissipated is unique to each process that requires cooling, and is based on the amount of undesirable heat generated during that process. For example, when compressing air in a multi-stage compressor, the air is heated up, loosing density and ultimately will reach a point where that air will damage materials it needs to interact with. To address this, a cooling tower may be employed to cool the air by circulating cooled water from an evaporative cooling tower through an air-water heat exchanger after each stage. This value might vary under changing process conditions or plant outputs, so the maximum heat load generated must be accounted for when sizing a cooling tower.
  2. Range: The desired temperature reduction of the hot process water to the desired cooled temperature, defines the range. Higher ranges demand larger towers and increased energy input, necessitating a judicious balance between desired cooling level and operational efficiency. This value is typically an input and is based on the heat load that needs to be dissipated, as well as the heat-exchange efficiency of the heat exchangers being used to dissipate the heat. If the overall heat transfer coefficient of the heat exchangers in place is known, then the range can be calculated, and vice-versa.
  3. Approach: This parameter measures the difference between the outlet cold water temperature and the ambient wet-bulb temperature. A smaller approach implies higher efficiency but necessitates a larger tower to accommodate the required heat transfer surface area. The closer the outlet cold water temperature is to the ambient wet-bulb temperature, the more efficient the cooling tower is.
  4. Wet-Bulb Temperature: This crucial environmental factor represents the minimum achievable water temperature via evaporation at a given humidity. High wet-bulb temperatures limit cooling potential and necessitate larger towers or alternative cooling methods to meet process requirements. This value varies seasonally and between locations. The seasonal mean, maximum and minimum must be taken into account when sizing a wet-cooling tower. As an example; if the seasonal maximum wet-bulb temperature coincides with the peak plant or process demand, then the cooling tower will be pushed to its limits to reject the resulting high heat load with a lower achievable minimum temperature due to the higher wet-bulb temperatures.

A graphical representation of Range and Approach

Figure 1: A graphical representation of Range and Approach. https://www.researchgate.net/publication/345463378/figure/fig3/AS:958892817276932@1605629271660/Diagram-Showing-Cooling-Tower-Range-Approach.jpg

Selecting an evaporative cooling tower demands a comprehensive understanding of these four interconnected factors. Utilizing accurate heat load calculations, optimizing range and approach for efficiency, and accounting for local wet-bulb temperature variations are key to achieving optimal cooling performance and cost-effectiveness.

Each of these has an impact on the size and design of the cooling tower:

When three of these four sizing factors are held constant, the requirement for cooling tower size varies directly with heat load, but inversely with range, approach, and wet bulb temperature. This highlights the interplay between these factors and the importance of considering how they might vary with plant operation and atmospheric conditions to optimize cooling tower size.

Cooling load comprises two primary components: sensible heat and latent heat. Sensible heat refers to the energy required to raise the temperature of a substance without causing a change in phase, while latent heat is the energy absorbed or released during a phase change, such as from liquid to vapor.

Heat gain, the total amount of heat entering a system, contributes to the overall cooling load. Sources of heat gain include process heat generated by industrial equipment, solar radiation, and heat transfer from the surrounding environment

Several factors influence the cooling load of a system, including:

Calculating cooling load involves considering the various factors mentioned above. Manual calculation methods, while effective, can be time-consuming and prone to errors. Alternatively, specialized software tools offer a more convenient and accurate approach to cooling load calculations.

3. Sizing Considerations for Different Applications

Selecting the optimal size for an evaporative cooling tower requires astute consideration of the specific application. While the core principles remain constant, the nuances of heat rejection demands vary across industries. Let’s delve into the unique sizing considerations for three key domains: power plants, petrochemical industries, and HVAC systems.

Power Plants

The colossal heat loads generated by power plants pose unique challenges. Accurately estimating condenser heat rejection and factoring in seasonal ambient variations are crucial. Additionally, optimizing range and approach for maximum efficiency under variable load conditions is paramount. Often, multiple tower arrangements are employed to ensure seamless operation across all load profiles.

The cooling towers used in power plants are typically natural-draft cooling towers, using large towering structures that exploit the occurrence of upwards airflow due to their curved shapes and hot, moist air, to expel heat to the atmosphere. Cooling is critical for steam-turbine power plants, where immense volumes of steam are expanded over a turbine to generate vast amounts of electrical energy. This steam, however, needs to be condensed once it has past through the turbine, in order for the vapour to return to a liquid form as well as to maintain a vacuum over the turbine for increased pressreu drop and efficiency.

During the operation of power plants, the most criticalproblem is the use of cooling equipment

for circulating water, particularly in the summer hot period of the year, when the difference between the air temperature and that of the water supplied from the turbines for cooling is smaller. The changes in climatic conditions and trends appearing in recent years; characterised by longer periods high temperatures and greater stress on available water resources, have had a negative impact on the sustainability of standard operating conditions cooling systems of power plants. This makes the selection of cooling technology and the sizing thereof even more important in order to avoid resulting envrionmental penalties and increased water-related costs.

Petrochemical Industries

The diverse and often exothermic nature of petrochemical processes necessitates a flexible and extensive cooling approach. Precise heat load calculations for individual process streams and accurate wet-bulb temperature data become critical. Material selection for the tower and fill media must take into account potential exposure to corrosive chemicals. Redundancy in tower configurations is often employed to ensure uninterrupted process operation both to ensure plant-uptime and production, but also to guarantee the safety of the hazardous nature of the reactions taking place.

Due to the variety of cooling requirements at a petrochemical plant, a centralised approach to cooling is often not possible. As such, various cooling tower clusters are often incorporated. Each cluster will need its own load determination and sizing calculations in order to select the right size and amount of cooling towers. The make, model and technology used for each application might vary, so a cookie-cutter approach to sizing will not be advisable in this sector.

HVAC Systems

Chilling requirements for buildings present a different set of sizing challenges. Fluctuating cooling demands due to occupancy and weather necessitate careful consideration of part-load performance. Smaller tower footprints and noise emission constraints come into play. Additionally, water treatment and drift loss management become crucial factors in selecting the optimal tower size and configuration.

Since HVAC systems use refrigerants to provide chilled water, and air, to the various demand centres in a building, evaporative condensers will be used alongside chillers. This, therefore, adds an additional complication in sizing that needs to be taken into consideration. The chiller will determine the cooling tower or condenser size. Some Chillers have built-in condensers, and therefore only need standard evaporative cooling towers on the exterior of the building. Some chillers need the condenser to be the cooling tower itself, with refrigerant gasses flowing on the inside of tube bundles, and cooling water flowing on the exterior of the tubes in order to condense the gasses.

4. Conclusion

Despite their individual nuances, certain principles bind these diverse applications. Accurately determining heat load, carefully selecting range and approach, and accounting for local wet-bulb conditions remain foundational to effective tower sizing. Additionally, understanding the importance of tower material selection, drift loss control, and maintenance considerations are crucial for long-term operational success.

Selecting the optimal evaporative cooling tower size is an intricate dance between process demands, environmental conditions, and cost considerations. Each application presents a unique set of challenges, necessitating careful analysis and a tailored approach. By understanding the nuances of each domain and applying fundamental engineering principles, we can craft an oasis of efficient cooling that caters to the specific needs of any thirsty process.

Our BUILT Substack Newsletter

Join 27,000+ others. Short, fascinating engineering & infrastructure posts.

Once per week

By DR. DF Duvenhage

1. What are cooling towers, and where are they used?

Evaporative cooling is a well-established and effective method for removing heat from various systems and processes and has been used for over half a century. Its popularity stems from its numerous advantages, including compactness, quiet operation, low energy consumption, and potential for water reuse and savings. Moreover, evaporative cooling systems are simple to operate and maintain, ensuring system efficiency and safety.

Cooling towers find application in a wide range of industries, including:

Cooling towers effectively reject large amounts of heat to the atmosphere, ensuring optimal operation of various processes and equipment. By removing heat, cooling towers help lower energy consumption in multiple applications. Precise temperature control is crucial for many processes, and cooling towers play a vital role in achieving this. Closed-circuit cooling towers can significantly reduce water consumption and minimise environmental impact.

The specific type of cooling tower best suited for an application depends on various factors.

Cooling towers are versatile and efficient systems for removing heat from various processes and equipment. Their diverse applications and numerous benefits make them vital components in many industrial and commercial sectors. By carefully considering the application’s specific needs and choosing the appropriate type of cooling tower, companies can achieve optimal performance and maintain sustainable operations.

2. Evaporative Cooling Tower Types: More than one way to cool the load

Cooling towers can be generally categorised by the following characteristics:

  1. The type of heat transfer medium;
  2. The type and location of the draft;
  3. The type of contact with water.

Since the heat transfer medium we focus on in this article is water (point 1), we will only focus on different wet, or evaporative, cooling tower configurations due to its superior heat capacity through evaporation.

The type of heat transfer medium

Air

Cooling towers which use only air to cooling a process fluid are typocially referred to as Dry Cooling Tower, or Air-cooled Condensers. Dry cooling towers offer a unique and environmentally friendly solution for industrial applications. Unlike traditional wet cooling towers, they require no water, making them ideal for water-scarce, arid regions and ecologically sensitive areas.

Dry cooling towers rely on air-cooled heat exchangers to dissipate heat from the process fluid. This eliminates the need for water evaporation, resulting in minimal water consumption and plume formation. The process fluid never directly contacts the cooling air, ensuring its purity and preventing contamination. Dry cooling towers come in various configurations, including natural draft, mechanical draft, and hybrid models that combine dry and wet cooling technologies.

Air-cooled cooling towers significantly reduce water usage compared to traditional wet cooling towers. This makes them a sustainable option for water-scarce regions and can offer significant cost savings on water bills. By eliminating water evaporation and plume formation, dry cooling towers have a considerably lower environmental footprint than traditional towers. The closed-loop system eliminates the risk of contact between the process fluid and the cooling air, preventing corrosion and extending the lifespan of the equipment.Therefore, they require less maintenance than wet cooling towers, as they have fewer moving parts and are less susceptible to scaling and water-related issues.

There are, however, certain disadvantages, such as their higher initial cost. This can be a significant barrier for some projects. Dry cooling towers are generally less efficient than wet ones, especially in hot and humid climates. This means they may require larger footprints to achieve the same cooling capacity. Mechanical draft dry cooling towers can generate significant fan noise, which may require additional noise mitigation strategies to comply with noise regulations. In extremely hot and humid conditions, the cooling capacity of dry cooling towers may be insufficient for some applications.

Water

Wet cooling towers are the most widely used type of cooling tower, offering a reliable and cost-effective solution for industrial and commercial applications. They operate by evaporating water to dissipate heat from various processes and equipment.

In the case of open-loop design, the process fluid comes into direct contact with air, allowing efficient heat transfer through evaporation. Generally, water is sprayed over the fill media, creating a large surface area for evaporation. As the water evaporates, the air absorbs heat, cooling the fluid flowing through the tower. The evaporation process produces a visible plume of water vapor, which can be a concern in areas with strict air quality regulations.

Picture1

Cooling tower plumes https://s33600.pcdn.co/wp-content/uploads/2021/05/cooling-tower-power-plant.jpg

Wet cooling towers are highly efficient at removing heat, making them ideal for applications requiring significant cooling capacity. Compared to dry cooling towers, wet cooling towers are typically cheaper to purchase and install. Wet cooling towers are generally more compact than dry cooling towers, making them suitable for space-constrained installations. Wet cooling towers are relatively easy to operate and require minimal maintenance, yet if this maintenance is addressed, it will be beneficial to the operational efficacy and longevity of the cooling tower.

The major disadvantage with wet cooling towers is that they use a significant amount of water, which can be a concern in water-scarce regions and may incur higher water bills. The evaporation process generates a visible plume, which can contribute to air pollution and increased humidity in the surrounding area. The cooling water can contain minerals that can lead to scaling and corrosion of the tower’s internal components, increasing maintenance requirements. In cold climates, the plume can pose safety concerns by forming ice on nearby structures and equipment. Furthermore, freeze protection might have to be included in areas prone to sub-zero temperatures.

The type and location of the draft

Induced Draft

In this configuration, the fan (1) is located at the top of the cooling tower, “sucking” air in through the inlet louvres (2) around the periphery of the bottom section of the cooling tower. This air then flows upwards, rejecting the higher-temperature air and evaporating moisture into the atmosphere.

Forced Draft

Here, the fan (1) is located on the side of the cooling tower, “pushing” air up through the cooling tower, resulting in the same heat rejection principles as for an Induced Draft configuration.

Picture2

Comparison of Induced and Forced Draft Cooling Towers

Neither configuration has a significant impact on the sizing of the cooling tower. Instead, the choice between them is based on practical reasons such as noise and space constraints, ease of access to the fan and fan motor and equipment longevity.

The type of contact with water

Open cooling towers

These cooling towers expose process cooling water to the atmosphere. These open towers use an efficient, simple, and economical design. All components in an open system must be compatible with the oxygen introduced via the cooling tower.

Open cooling towers reject heat from water-cooled systems directly to the atmosphere. Hot water from the process enters the cooling tower and is distributed over the cooling tower fill. Air is pulled (induced draft) or pushed (forced draft) through this fill, causing a small portion of the water to evaporate. Evaporation removes heat from the remaining water, which is collected in the cold water basin and returned to the system to absorb more heat.

Their design and operation prioritize efficiency and simplicity, making them a popular choice for many applications. The fill media used in open cooling towers is mainly to maximize the contact surface area between water and air, enhancing the cooling process.

Open-circuit towers achieve high cooling efficiency due to the direct contact between water and air. This makes them ideal for processes requiring significant heat removal. They are also, therefore, best-suited to dry climates, where the relative humidity is lower, thereby decreasing the wet-bulb temperature relative to the dry-bulb temperature. Their relatively simple design translates to lower initial investment costs and easier maintenance compared to other cooling tower technologies. Due to the simple design and higher heat-rejection efficiencies that can be achieved, they require less space than other cooling tower designs, making them suitable for installations with limited space. As a result of the above characteristics, open-circuit towers are readily available from various manufacturers, offering flexibility and cost competitiveness.

The major draw-back from the direct contact of the cooling water with air leads to significant water evaporation, requiring a continuous supply of makeup water. This can be a concern in water-scarce regions and contribute to higher operating costs. The evaporation process generates a visible plume, which can impact air quality and raise humidity levels in the surrounding area. This may require additional mitigation measures to comply with environmental regulations, particularly in urban areas. Minerals in the makeup water can accumulate on the tower’s internal components, as well as process heat exchange equipment where heat is absorbed, leading to scaling and corrosion. This can reduce efficiency and require regular maintenance to address.

Open-circuit cooling towers offer a simple, efficient, and cost-effective solution for various heat rejection needs. However, their high water consumption, environmental impact, and potential for scaling and drift require careful consideration. Choosing open-circuit towers requires balancing their advantages with potential drawbacks and ensuring compliance with environmental regulations and water management practices.

Closed circuit cooling towers

Conversely, these cooling towers completely isolate process cooling fluid from the atmosphere. This is accomplished by combining heat rejection equipment with a heat exchanger equipment, typically tube bundles, in a closed circuit tower. A closed loop system protects the quality of the process fluid, reduces system maintenance, and provides a degree of operational flexibility at a slightly higher initial cost.

Closed circuit cooling towers operate in a manner similar to open cooling towers, except that the heat load to be rejected is transferred from the process fluid (the fluid being cooled) to the ambient air through a heat exchanger. The heat exchanger typically takes the form of a coil of tubes, and serves to isolate the process fluid from the outside air, keeping it clean and contamination free in a closed loop. This creates two separate fluid circuits: (1) an external circuit, in which spray water circulates over the exterior of the coil and mixes with the outside air, and (2) an internal circuit, in which the process fluid circulates inside the coil to be cooled and is returned to the process at a lower temperature. During operation, heat is transferred from the internal circuit, through the coil to the spray water, and then to the atmosphere as a portion of the water evaporates.

By eliminating direct contact, closed-circuit towers slightly reduce water evaporation and water use compared to open-circuit systems. The reduced evaporation results in a significantly smaller or even non-existent plume, minimizing the environmental impact and visual pollution. The closed loop prevents contamination of the process fluid, ensuring its purity and facilitating precise temperature control.

However, compared to open-circuit towers, closed-circuit systems are generally less efficient in heat transfer due to the additional heat exchange step. The more complex design and components of closed-circuit towers result in higher initial investment costs compared to open-circuit systems. The additional components and closed loop require more frequent and specialized maintenance to ensure optimal performance.  Mechanical draft closed-circuit towers can generate significant fan noise, requiring additional sound attenuation measures to comply with noise regulations.

Picture3

Comparison of Open and Closed Circuit Cooling Towers

3. The anatomy of a cooling tower

While seemingly simple from the outside, a cooling tower is in fact an intricate system comprised of various essential components working to effectively remove heat. In it’s most basic form, evaporative coolers are even used in-doors in hot and dry climates to cool rooms. They work in the same general way and on the same fundamental principle of evaporation as the primary form of cooling.To achieve this, the following basic components are required in a cooling tower, irrespective of its configuration, as discussed above.

  1. Basin: This forms the base of the tower, collecting the cooled water and providing a reservoir for the recirculating water system. Its volume is carefully calculated to maintain adequate water inventory, ensuring consistent performance and preventing pump cavitation. Thermal stratification can occur within the basin, with warmer water settling near the bottom and cooler water rising to the surface.

This necessitates proper mixing techniques to achieve uniform water temperature throughout the basin and optimize cooling efficiency.If the cooling capacity needs to be increased, multiple cooling tower cells (fans and fill sections) can be combined in a common-basin configuration. This provides an advantage in the form of centralised treatment for a large system, instead of separate treatment systems required for separate basins.

To compensate for water losses due to evaporation and drift, makeup water is introduced into the system. The basin serves as a mixing point for the makeup water and the recirculating water, ensuring even distribution and temperature equilibrium before the water re-enters the cooling cycle.

A concrete basin of a field errected cooling tower

A concrete basin of a field-errected cooling tower.

https://towertechinc.com/wp-content/uploads/2022/05/open-basin-tower-1-2048×1152.jpg

Basins of varying sizes of packaged cooling towers

Basins of varying sizes of packaged cooling towers.

  1. Fill Media: This is the heart of the tower, consisting of specialized packing materials that provide a large surface area for the hot water to spread and facilitate heat transfer to the air. The primary function of fill media is to maximise the contact surface area between water and air. By employing intricate designs and varied geometries, fill media offer a vast canvas for heat dissipation. Beyond mere surface area, fill media actively facilitates efficient water distribution and interaction with the airflow. Certain designs fragment water into fine droplets, maximising air exposure. Others encourage thin water films to cascade down, mimicking a refreshing shower for the air.

An example of fill media

An example of fill media

https://www.coolingtowerinfill.com/data/watermark/20200422/5e9feceb6450e.jpg

  1. Water Distribution System: This network of pipes and nozzles evenly distributes the hot water over the fill media, ensuring optimal contact with the air for efficient cooling. The primary objective of the water distribution system is to deliver a uniform film of water across the entire surface area of the fill media. This necessitates careful hydraulic calculations to overcome pressure drops, ensure consistent flow rates across different sections, and minimize dead zones where water stagnates and contributes to inefficient heat transfer.

At the heart of the system lie the nozzles, meticulously engineered to atomize the water into fine droplets or sheets. Different nozzle types, such as pressure-jet, fan-type, and full-cone, offer varying spray patterns and flow rates, catering to specific fill media designs and cooling requirements. Proper nozzle selection and orientation are crucial for achieving optimal droplet size, ensuring maximum surface area contact with the air, and minimizing drift loss.

Water distribution headers and spray patterns from the nozzles

Water distribution headers and spray-patterns from the nozzles.

  1. Air Inlet Louvers: These louvers regulate the airflow into the tower, allowing for proper ventilation and preventing water droplets from escaping. The primary function of air inlet louvers is to channel and direct the airflow into the tower. By employing angled blades or vanes, louvers create a controlled airstream that efficiently sweeps across the fill media, maximizing air-water contact and heat exchange. Proper louver design minimizes dead zones within the tower, ensuring all fill media areas experience optimal airflow and contribute to the cooling process.

In certain applications, controlling sunlight exposure within the cooling tower is crucial. For example, excessive sunlight can promote algae growth in the water, leading to increased maintenance and potential biofouling issues. Air inlet louvers can be designed with light-blocking features, such as angled panels or opaque materials, to minimize sunlight penetration and maintain optimal water quality.

  1. Fan System: This system generates airflow through the tower, drawing in fresh air and expelling the heated air. Fans can be axial or centrifugal, each with its own advantages. Axial fans, resembling airplane propellers, generate high airflow volumes at lower pressures, ideal for open-circuit towers. Centrifugal fans, reminiscent of car engine fans, create high pressures with focused airflow, making them better suited for closed-circuit systems.

Modern fan systems often incorporate variable speed drives (VSDs). These allow for adjusting the fan speed based on real-time cooling demands, optimizing energy consumption and reducing noise pollution during periods of lower load.

Since fans are considered roating machinery, they are subject to the typical challenges faced by this class of equipment. Fan blades are subject to immense forces, leading to vibration and potential imbalance. This can cause excessive wear and tear on bearings, shafts, and surrounding components, impacting performance and noise levels. Regular balancing checks and adjustments are crucial. Furthermore, exposure to extreme temperatures, humidity, and corrosive elements can accelerate wear and tear on fan components. Choosing corrosion-resistant materials and implementing preventive maintenance measures are essential.

Centrifugal fans left compared to axial fans right

Centrifugal fans (left) compared to axial fans (right).

https://www.mitacoolingtechnologies.com/wp-content/uploads/2018/12/Centrifugal-or-axial-fan.jpg

  1. Drift Eliminators: These are mesh-like structures that capture small water droplets entrained in the air, minimizing water loss and drift. Drift eliminators achieve their objective through various mechanisms. Common designs employ mesh screens, baffles, or inclined surfaces to intercept water droplets carried by the airflow. Droplets collide with the eliminator elements, lose momentum, and fall back into the water basin for recirculation.

Effective drift elimination requires a balance between capturing droplets and maintaining desired airflow for heat transfer. Eliminator designs minimize airflow impedance while maximizing droplet capture efficiency. Advanced designs employ computational fluid dynamics simulations to optimize the geometry and placement of eliminator elements.

A top view of drift eliminators installed in a cooling tower

A top-view of drift eliminators installed in a cooling tower.

https://www.vistechcooling.co.uk/wp-content/uploads/2019/12/Unknown-Drift-Eliminators-Unknown-1-1-2048×1536.jpg

  1. Casing: This encloses the entire structure, protecting the internal components from the environment and ensuring structural integrity. The casing provides the primary structural support for the entire cooling tower, housing the heavy internal components like fill media, basins, and water distribution systems. It must withstand significant loads from water weight, wind forces, and seismic activity.The casing provides the primary structural support for the entire cooling tower, housing the heavy internal components like fill media, basins, and water distribution systems. It must withstand significant loads from water weight, wind forces, and seismic activity. The casing contributes to reducing water loss through drift. Its tight construction and strategic openings help capture entrained water droplets and direct them back into the basin for recirculation.

    The casing can be constructed from a variety of materials, with some of the more popular options being:

    • Concrete: Durable and affordable, concrete casings offer high structural integrity and fire resistance. However, they are heavier and require longer construction times.
    • Steel: Lighter than concrete, steel casings offer faster construction and adaptability to various configurations. However, they require corrosion protection and may be more susceptible to noise emission.
    • Fiberglass Reinforced Plastic (FRP): Lightweight and corrosion-resistant, FRP casings provide good thermal insulation and noise reduction. However, they may have lower structural strength and higher initial cost compared to concrete and steel.
  2. Makeup Water System: This system replenishes the water lost through evaporation, purge (blowdown) and drift, maintaining the water level and ensuring efficient operation. Makeup water can be sourced from various options, including municipal supply, wells, surface water sources like rivers or lakes, or treated wastewater. The choice depends on availability, water quality, and cost considerations.
  3. Control System: This system regulates the operation of various components, including the water distribution system, fan speed, and makeup water supply, optimizing cooling performance and energy efficiency. Typically, a cooling tower is run as a on/off system, directly controlled by the primary process’ SCADA according to predetermined setpoints required to be maintained for the particular process.
  4. Access Doors and Platforms: These provide safe access through the cooling tower casing into the internal areas to maintain and inspect the tower’s enclosed components.

4. Cooling towers: simple in their complexity

By understanding the basic anatomy of a cooling tower and the role of each component, we gain a deeper appreciation for the engineering and technology behind this essential piece of equipment used in diverse applications across industries. Evaporative cooling towers operate on a simple principle but require the harmonious functioning of the various sub-components that are correctly sized, made from the correct materials to handle the conditions, and arranged in the most appropriate configuration to meet the specific application’s needs. This makes the system comprising a cooling tower appear complex. However, each of these sub-components are in their own right, relatively simple in purpose and integration.

This article highlighted an evaporative cooling tower’s primary functioning principle and purpose, considered the different types and configurations, and concluded with an in-depth evaluation of its major sub-components. Future articles will consider the appropriate approach to sizing a cooling tower, factors that need to be considered for maintaining its effective operation and longevity, and an overview of the different economic sectors in Southern Africa that make use of them the most.

Our BUILT Substack Newsletter

Join 27,000+ others. Short, fascinating engineering & infrastructure posts.

Once per week

1 Introduction

1.1 Battery Electric Vehicles

With zero tailpipe emissions, the positive impact of electric vehicles (EVs) on air quality in urban centres is widely accepted. Regarding their global environmental impact and life cycle carbon emissions, they are regularly subject to debate.

EVsInstead of an internal-combustion engine,  operate on an electric motor that generates power by burning a mix of fuel and gases. There are two basic classes: all-electric vehicles and plug-in hybrid electric vehicles. The former include Battery Electric Vehicles (BEVs) and Fuel Cell Electric Vehicles (FCEVs). Besides charging from the power grid, both types are charged in part by regenerative braking, which recovers some of the energy typically lost when braking [1]. We will, from here on, refer to BEVs when mentioning the concept of electric vehicles.

A BEV utilises chemical energy stored in rechargeable battery packs its prominent feature is that drivers plug them into an off-board electric power source. Otherwise, hybrids supplement an internal combustion engine (ICE) with battery power but cannot be plugged in. Also, BEVs have traditionally been developed as city cars, while small ICE supplement electrical systems in extended-range vehicles. BEVs just run on electricity, with most having 80 to 100 miles (130 to 160 km) of all-electric range, while a few luxury models have capacities of up to 250 miles (400 km). Depending on the type of charging device and battery, when its power source is depleted, it can take 30 minutes (with quick charging) to several hours to recharge it.

Life cycle GHG emissions of EVs relative to other powertrains

Figure 1. Life cycle GHG emissions of EVs relative to other powertrains. Source: https://www.iea.org/reports/global-ev-outlook-2020

With a GHG intensity of electricity generation equal to the global average (518 grammes of carbon dioxide per kilowatt-hour in 2018), BEVs, hybrid electric vehicles and fuel cell electric vehicles have similar lifetime emissions, lower than those of an average internal ICE vehicle (Figure 1).

Though the concept of electric vehicles has been around for a long time, it has gained a considerable amount of interest recently amid rising carbon footprint and air quality concerns. Electric vehicles are part of a scheme around the world focused on advancing environmentally sustainable transportation. Let’s discuss why life cycle assessments might be necessary when reporting greenhouse gas emissions, especially as we look out into the future, and we start adopting more electric vehicles.

1.2 Why Life Cycle Assessment?

To find out if an EV is better for climate, we must reason not in combustion, but life cycle: we will count the emissions due to the manufacture of the car, batteries, extraction and transport of fuel if necessary. Due to the lack of adequate evaluation tools, the indirect environmental effects of transportation disruptions on urban mobility have often been ignored. However, some trends are making life cycle assessment progressively critical [2]. Research institutes and regulatory bodies are developing methods to capture the environmental consequences of these disruptions’ entire cause and effect chain while adapting them to the city, regional, and national scales.

The term life cycle assessment or LCA refers to a structured environmental assessment method to quantify ecological flows and their impacts for a product or service from a cradle-to-grave perspective. We are therefore tracking material and energy inputs, waste and pollution outputs at each life cycle stage; but also analysing the supply chains that deliver those material and energy inputs, and pondering transportation at each stage. Life cycle assessments traditionally consider a whole range of environmental impact categories.

The main stages and typical inflows and outflows considered in life cycle assessment

Figure 2. The main stages and typical inflows and outflows considered in life cycle assessment. Source: https://www.e-education.psu.edu/eme807/node/690

However, many, EV lifecycle-based studies and automotive evaluations have focused on greenhouse gas (GHG) LCA, often referred to as carbon footprints. This is acceptable when the main concern is about climate change impacts, but if we want to understand the full burden of impacts associated with the technology we prefer to think about multiple environmental aspects not to trade one impact for another. Nonetheless, this article will focus only on carbon footprints or LCA of GHG emissions.

Trends in vehicle design, fuels, and users needs are shifting environmental impacts away from the operational life cycle stage [3]. The pie charts in Figure 3 depict gasoline, a conventional fuel that modern societies have depended on for a long time for passenger vehicles, with combustion dominating impacts such as greenhouse gas emissions and energy consumption. Likewise, impacts from cars have been dominated by the operation.

Today, the use phase is the largest contributor to life-cycle GHG emissions of all powertrains. But as we look at alternative fuels and trends towards electric vehicles that run on electricity and hydrogen, the upstream or life cycle-related impacts are increasingly important. As vehicles move towards electrification, production-related emissions exhibit an increasing dominance. These vehicles are more efficient, but as grids tend to decarbonise, GHG emissions and many other air pollutants are ipso facto reduced.

The relative importance of different life cycle stages for fuels and vehicles types

Figure 3. The relative importance of different life cycle stages for fuels and vehicles types.

1.3 Background: LCA of BEVs

Existing studies assessing BEV emissions have different life cycle scopes, which may include or exclude: vehicle and battery manufacturing emissions; power plant emissions from electricity generation; power plant fuel feedstock extraction, fuel extraction, processing, transportation, and combustion emissions; production and transportation emissions; and end of life emissions. Several studies have only included vehicle use or a subset of the emissions related to vehicle use (e.g., vehicle tailpipe emissions and power plant smokestack emissions), leading to incomplete assessments. Life cycle studies suggest that emissions implications from sources other than those two examples can comprise one fifth to one-third of vehicle life cycle GHG emissions, so addressing the full life cycle can be necessary for comprehensive comparisons.

Auke Hoekstra, Senior Advisor on Electric Mobility at the Eindhoven Technical University, is probably the world’s leading expert on cars’ life-cycle emissions. In a recent paper [4], he states that GHG emission reductions possible with BEVs are underestimated in the scientific literature. His thorough review work points out the following causes behind this issue: an overestimation of battery manufacturing, an underestimation in battery lifetime, a static electricity mix over the lifetime of the EV, unrealistic tests for energy use, exclusion of fuel production emissions, and lack of system thinking.

Moreover, previous LCA studies of BEVs have almost uniformly considered small, efficiency-oriented electric vehicles modelled on first-generation cars with approximately 25-kilowatt-hour batteries. Most of these studies have found that the electricity grid composition that charges the EVs and the climate they operate is crucial to understanding their performance [5] [6].

For instance, Specialists at Carnegie Mellon University compared life cycle GHG emissions from several light-duty passenger gasoline- and plug-in electric vehicles across US counties by accounting for driving conditions (city versus highway), ambient temperature, regional differences due to marginal grid mix, and patterns of vehicle miles travelled [7]. They found that EVs can have larger or smaller carbon footprints than gasoline vehicles, depending on these regional factors and the specific vehicle models being compared. Thus, one should look at the spatial and temporal dynamics of where these vehicles are operated and how the grids that they operate on might change over time (Figure 4). In addition to thinking about future electricity grids, it becomes crucial to discuss vehicle design trends.

Framework for a vehicle LCA based analysis

Figure 4. Framework for a vehicle LCA-based analysis. Source: https://iopscience.iop.org/article/10.1088/1748-9326/11/4/044007/meta#erlaa1cf0f1

2 Modelling Approaches

2.1 Trends in battery cost and performance

Some of the trends in vehicle change described in the following section can be explained, in part, by dramatic decreases in battery cost and input increasing performance of electric vehicle batteries. Figure 5 is a projection of the changing price. It stands out that the trends towards, for example, high performance and large vehicles might be something continuing to happen because of battery costs coming down. What happens to our understanding of battery electric vehicles’ life cycle impacts when considering some of these critical trends?

Battery pack price forecast

Figure 5. Battery pack price forecast. Source: https://its.ucdavis.edu/wp-content/uploads/The-Importance-of-Life-Cycle-Assessment-in-Evaluating-the-Environmental-Performance-of-Future-El.pdf

Regarding vehicle design and market trends, with these decreasing battery pack costs, we might see increasing battery pack size even in efficiency-oriented vehicles and greater dominance of luxury and high-performance cars in the BEV sector. We might also see the adoption of shared and autonomous vehicles, especially high-mileage applications, enabled by these larger batteries. Besides, as electricity grids decarbonise, mostly where BEVs are being adopted fastest like in California, the operation-related impacts of electric vehicles dramatically reduce but, potentially, the production-related implications of these vehicles increase. There are implications of these trends.

On the one hand, large and high-performance electric vehicles mean larger batteries and designs that may not focus on efficiency are likely to be bad for GHG emissions. Besides, increasing investment and interest in lightweight materials to deliver on performance and efficiency could also occur.

On the other hand, and likely to be suitable for emission reduction, an increase in range for these vehicles — going from a hundred miles to three hundred miles (160 km to 480 km), for instance — would mean that batteries might last a lot longer because they are not being cycled as deeply in terms of a depth of discharge which is a crucial deterioration process for batteries. Then, barriers to adoption could be reduced by including a higher mileage operation. We will provide some results where our goal is to give readers a preliminary LCA focusing on production and use of new-model and future-model BEVs considering only the most important Spatio-temporal dynamics like ageing electricity fuel mixes.

2.2 Vehicle scenarios

The majority of previous studies reflect outmoded assumptions about BEV designs and have not reflected trends in the car market. A sales review between 2012 and 2018 in the US shows a remarkable shift towards longer vehicle ranges, considerably higher capacity batteries, and a growing preference for high performance and luxury BEVs. The combined effect of these two trends results in an increase in BEV battery capacity of 6.5 kWh per year, from 20 kWh in the first quarter of 2012 to more than 70 kWh in the second quarter of 2018. As the market has grown, so too have the number of models available.

BEV sales and battery capacities in the US

Figure 6. BEV sales and battery capacities in the US. Source: https://doi.org/10.1016/j.trd.2020.102287

We notice significant changes in the types of vehicle that were being sold. The Nissan Leaf, shown in navy blue, dominated those small sales in the beginning, to the Tesla Model S (yellow) coming online and taking a reasonably large share of the market. For example, looking out to 2018, larger vehicles like the Tesla Model 3 and the Tesla Model X become best sellers. These figures should be highlighted because various electric cars can affect what we can say about their life cycle impact.

The recommended approach when accounting for vehicle diversity in LCA-based studies is to take a minimum of three archetypal BEVs, i.e. an efficiency-oriented compact vehicle (EOV), a high-performance luxury sedan (PLS), and a high-performance SUV (PSUV). Researchers and policymakers also need to explore some alternative use models such as shared and autonomous applications. To do this, they are sought to combine existing, and new, LCA models for vehicle components and systems, such as the battery LCA models and GREET from Argonne National Lab [8]. Some methods to estimate use phase impacts under different scenarios including annual mileage estimates from the National Highway Transportation survey or similar databases, and FASTSim, an estimator of BEV energy efficiency that assumes combined city-highway energy economy.

Studies should consider how future vehicle design changes, trends in battery performance, cleaner electricity grids, and annual mileage will affect each vehicle archetype’s total life cycle emissions. EV emissions coming from driving are supposed to be focused on the electricity mix over the vehicle’s whole endurance period. This leads to 55 gGHG per km for Europe. To calculate this accurately for a specific EV, assumptions must be made about the lifetime, e.g. 17 years, yearly mileage (let’s assume 26k km in the first year and 1k less per year), and energy use per km (0.161 kWh/km based on EPA measurements). Results are then usually presented in a functional unit of vehicle mile (or kilometres) travelled, where total emissions are divided by the vehicle’s lifetime miles. This facilitates comparisons with ICE vehicles.

2.3 Trends in electricity grids

As grids continue to get cleaner, i.e. they move towards lower emissions, both new and used electric vehicles will get cleaner as well. This is an asset EVs have over fossil-fueled cars: their emissions can get better over time. The fuel economy of gasoline vehicles is fixed and so are their emissions, as long as they depend primarily on petroleum for fuel. A future in which cars themselves, but the entire supply chain of cars operate on renewable energy could be imagined.

Batteries could power mining equipment that retrieves the ore from which windmills, solar panels, and batteries are made. Green hydrogen produced by solar and wind makes steel and aluminium zero-emission, which in turn makes the manufacturing of cars, batteries, and other clean technologies almost zero-emission. Car batteries also absorb excess solar and wind energy, stabilise the grid, and decrease the available stationary batteries. It is not an overstatement to say that the GHG emissions from batteries could be further reduced by a factor of ten in such a scenario.

Global electricity demand from electric vehicles hits 550 TWh in 2030 in the Stated Policies Scenario (SPS), which is about a six-fold increase from 2019 levels. According to the International Energy Agency projections, the share of demand due to EVs in total electricity consumption grows to as high as 4% in Europe. In the Sustainable Development Scenario (SDS), with demand rising nearly eleven-fold relative to 2019, to almost 1,000 TWh, the total market share ranges from 2% in Japan to 6% in Europe [9].

Electricity demand from the electric vehicle fleet by mode 2019 and 2030

Figure 7. Electricity demand from the electric vehicle fleet by mode, 2019 and 2030. Source: https://www.iea.org/data-and-statistics/charts/electricity-demand-from-the-electric-vehicle-fleet-by-mode-2019-and-2030

Electricity grid trends are usually modelled through a so-called business as usual scenario (BAU), which is essentially the fuel mix for ongoing conditions in a specific electric grid. In the US, for instance, increasing proportions of renewable sources are observed, yet, one would not find the same trend towards a profound reduction in fossil fuels. Consequently, emissions are evaluated under a reference case or BAU, and a carbon tax scenario assumes an allowance fee on CO2 emissions from utility-scale electricity generators.

Carbon tax scenarios are included to represent the potential impact of further changes to the grid mix, particularly for in-use vehicles, and the magnitude of possible change for the average vehicle fleet. Carbon pricing is a policy instrument aimed at minimising the amount of carbon dioxide released into the atmosphere by placing either a tax or a limit on the tons of carbon dioxide emitted. When applied to the electricity sector, carbon pricing discourages the use of carbon-intensive generators in favour of lower- or zero-emitting alternatives [10].

As a result, the average emissions rate (EFt) can be estimated as the mass of GHG equivalent emissions per unit of delivered energy with the following general equation [11]:

eft

where the weighted generation by year (t) and fuel source (x) is multiplied by the life cycle inventories (LCI) of emissions species (e) by fuel type (x), and the impact characterisation factors (m). Therefore, the resource mix can be broken into different fuel source categories: renewables, coal, natural gas, nuclear, fuel oil, etc.

3 Key Findings

3.1 Overall modelling results

Are EVs better for the climate? Yes. This section explores the relative importance of GHG emissions along various stages of the vehicle life cycle. It identifies drivers of emissions reduction for different vehicle technologies relative to each other. In their use phase, EVs have net GHG emissions reductions compared with fossil-fuelled vehicles, but this does not account for the emissions that occur during manufacturing and other moments of the vehicle’s full life of the vehicle.

In the studies compared below, the GHG intensity (expressed as kg CO2-eq/kWh) varies based on the assumed energy use for battery manufacturing and battery energy density. One important outcome here is that the GHG emission intensity of battery manufacturing per kWh tends to decline as assumptions on battery energy density, plant size and plant capacity utilisation increase.

Battery energy density for lithium ion NMC batteries energy use and GHG emissions intensity from manufacturing by various analyses

Figure 8. Battery energy density for lithium-ion NMC batteries, energy use and GHG emissions intensity from manufacturing by various analyses. Source: https://www.iea.org/reports/global-ev-outlook-2019

Taking an integral system perspective further highlights the potential of batteries and BEVs.

The answer to this article’s prime question is not always apparent given the result of an extensive assessment whose report is available on the European Commission’s website — often better than thermal, but not always [12]. On the other hand, the difference is noticeable for a country like France or Sweden, where electricity is very low-carbon. In other words, the main GHG emissions reduction potential over the vehicle life cycle seems to be in the decarbonisation of the power system. In an example calculation, BEVs reduce emissions from 244 to 98 g/km. In a fully renewable system, BEV emission could decrease to 10 g/km [4].

The chart in Figure 9 shows on the left several vehicle scenarios and bars that consist of a yellow part — operation emissions assuming US average grid; a grey part — vehicle materials and glider assembly, i.e. vehicle production; and two blue parts — battery materials production and battery manufacturing itself. The first vital takeaway to acknowledge is that, compared to ICE and HEV, electric vehicles perform better, meaning they have fewer emissions per mile (or kilometres). On the bottom, we can observe the shared and autonomous vehicles. The first thing to watch is that there are great benefits of adopting electric vehicles in these applications relative to an ICE SUV.

With that said, the vehicles’ production-related impacts and the batteries are much smaller relative to the operation. That is happening because these types of vehicles are being used a lot every day. It is also noticeable the difference in relative impacts of vehicle production compared to battery changes, that is because in these high-mileage applications we have assumed battery replacement. Hence, the relative contribution of vehicle and battery production is slightly different.

The main takeaway from these results is that it does matter what case we consider in terms of the proportion of impacts of commute or operation emission in regards to production; but also that as EVs are operated in places like California, the production-related emissions are significant for understanding the life cycle impacts of the vehicle.

GHG emissions of vehicle battery and use phase by vehicle grid and utilisation scenario

Figure 9. GHG emissions of vehicle, battery, and use phase by vehicle, grid, and utilisation scenario. Source: https://doi.org/10.1016/j.trd.2020.102287

Driving emissions are where the BEV realises significant gains on the diesel car. Care must be taken to calculate the electricity mix over the lifetime of the BEV. For the diesel, GHG emissions during fuel production (predominantly from refineries) should be included. All energy use should be based on realistic road tests or numbers of the US Environmental Protection Agency (EPA). This leads to 55 g GHG per km for the BEV and 217 g for the diesel vehicle.

3.2 The California case

The Golden State scenario provides a useful comparison: California represents nearly 50% of the American BEV fleet, over 8% of new vehicles sold in the state are electric (compared with 2% nationally), a large share — around 50% — of its electricity is generated by renewable sources, and finally, the state has enacted progressive policies pushing further deployments of renewables and EVs [13]. There is a clear trend towards the dominance of renewables in California and the only fossil fuel remaining in the mix being some portion of natural gas.

There are significant differences between the values we see for electric vehicles operated on the average US grid and electric vehicles used in California: Life cycle emissions from BEVs under the California scenarios were ~45% lower than under the US average scenario according to a recent study [11]. In Figure 9 we have a national average for the US — the business-as-usual case with yellow bars — then different scenarios: with a carbon tax — the red x mark — and then for California (CAMX) — the black diamond. It should be highlighted that when operating an electric vehicle in California, vehicle production is often more than half of the impact.

Carbon dioxide-equivalent emitted through a life cycle approach for current market BEVs range from 136 gCO2e/mile for an efficiency-oriented compact vehicle in California up to 324 gCO2e/mile for the larger SUV in the US average scenario. In 2025, emissions decrease to 105 gCO2e/mile for an EOV in California, while potentially increasing to 374 gCO2e/mile for the PSUV in the US.

This leads to the net GHG emissions factor per kilowatt-hour that shows deep California reduction and only mild reductions for the US average under the business-as-usual scenario. However, when a carbon tax scenario was tested, it did not significantly affect California, maybe because the state is already increasing their renewables share quite rapidly.

3.3 Battery end-of-life

The term end-of-life (EOL) is the catchall for what is done with the product after being used. The EOL stage includes the disposal and recycling of the glider. It should be outsourced that although recycling, remanufacturing, and reuse are all options, in theory, the fate and reuse or recycling potential of EOL batteries is still uncertain and has not been addressed explicitly in most studies.

Circular Economy Pathways for EV Batteries

Figure 10. Circular Economy Pathways for EV Batteries. Source: https://batteryindustry.tech/wp-content/uploads/2020/04/Circular-Economy-Pathways-for-EV-Batteries.png

While EOL battery-related emissions and the potential benefits of reuse and recycling are not inherently high from a carbon perspective, other environmental impacts are concerned. The current falling costs of batteries and relatively low value of constituent elements post-recycling present challenges for robust recycling systems. Regarding battery lifetime, it is essential to remember that great strides have been made in recent years. Presently, when motor maintenance becomes too costly, cars are scrapped. But this would no longer be the bottleneck for a BEV because the electric motor outlasts most other car components without maintenance. It is estimated that current batteries last at least 1,500 to 3,000 cycles until they lose 20 per cent of their capacity, giving a battery life of 450k to 1,350k km to an electric car with a range of 450 km. Moreover, advances such as solid-state electrolytes could further increase cycles to between 5,000 and more than 10,000 in 2030 while also making batteries nonflammable.

The Battery Directive has set industrial and automotive battery waste management standards in the European Union, including banning landfilling and incineration,  mandating companies to collect and recycle them instead. It also fixes a minimum required recycling rate for each category. Nonetheless, this strategy was decided based on battery technologies that are no longer dominant and is subject to revision [14].

Volumes of Li-ion batteries are expected to soar with the deployment of EVs. Therefore, the legal structure will benefit from being strengthened and modified to consider the new complexities of the transition to EVs and related batteries. This could be enforced, for example, via recovery mandates for each critical battery material separately, instead of a fixed rate for the battery as a whole.

3.4 LCA-based policies

The global policy context is set to regulate vehicle efficiency, fuel economy, and tailpipe emissions. The US and California already think about the life cycle of fuels in some contexts (e.g. the Low Carbon Fuel Standard (LCFS) and RFS2 in a more limited way. But we do not find a general context for thinking about the whole vehicle life cycle (Figure 11).

Vehicle life cycle policy categories and

Figure 11. Vehicle life-cycle policy categories and examples. Source: https://www.researchgate.net/figure/ehicle-lifecycle-policy-categories-and-examples_tbl1_223610448

By omitting life cycle emissions, policymakers could develop a paradoxical policy outcome meaning that even when intending to favour vehicles with lower GHG emissions, cars with higher emissions could result favoured instead. Another question is whether there are benefits to life cycle based policies, such as flexibility for meeting GHG targets for vehicles. Preferences for vehicle light-weighting actions, for example, can also require a life cycle assessment to understand benefits. Indeed, one of the significant challenges to deal with is that a lifecycle-based vehicle policy could be admittedly complex and challenging to achieve if not properly developed and managed.

When looking for actual lifecycle-based policies, we would find only one class of policies that have implemented life-cycle carbon accounting or greenhouse gas assessment, the low carbon fuel standards. In California, policymakers implement it through a standard government-provided model.

Providing a tool and default carbon intensity estimates, the risk of high variability and a lack of transparency is reduced. Without that kind of common modelling framework, there would be a considerable amount of flexibility for vehicle producers to play around with and, eventually, generate bad examples such as ‘Astongate’. Earlier this year, green experts hit out at data underpinning an EV life-cycle CO2 assessment report backed by Aston Martin and Bosch [16]. The two firms were accused of using controversial figures to downplay EVs’ environmental benefits, with the former forced to delay the launch of its EVs until 2025.

Figure 12 has been extracted directly from the low carbon fuel standard website. What we can see is that these fuel pathways that the initiative has come up with. One can request a fuel pathway to receive a carbon intensity score; the tool then provides default carbon intensity estimates. However, there is also the option for vehicle producers to request their carbon intensity scores.

Carbon intensity value adjusted by its Energy Economic Ratio EER representing the emissions that occur from alternative fuel per MJ of conventional fuel displaced

Figure 12. Carbon intensity value adjusted by its Energy Economic Ratio (EER), representing the emissions that occur from alternative fuel per MJ of conventional fuel displaced. Source: https://ww2.arb.ca.gov/resources/documents/lcfs-pathway-certified-carbon-intensities

4 Conclusion

This article demonstrates a qualitative framework for understanding GHG emissions’ direct and indirect impacts in the electric transportation sector. By an LCA approach, we find essential feedback loops that allow for identifying and discussing trends in vehicle model scenarios, electric grids, unintended consequences, and policy synergies. The role of qualitative analysis is vital in the policymaking process, especially in electromobility analysis, where many key decision factors are uncertain or unknowable to date.

Assessing whether or not EVs bring about overall net reductions in greenhouse gas emissions to other powertrain options requires a life-cycle analysis. The extent to which a contemporary average BEV emits less GHG than a regular ICE vehicle depends on the electricity generation mix’s carbon intensity in the use phase and the car’s size. The main GHG emissions reduction potential over the vehicle life cycle is in the power system’s decarbonisation.

Electric cars are now contributing to much lower air emissions than their gasoline-powered counterparts, and are becoming even cleaner. Optimising the manufacturing of EVs and the recycling or reuse of batteries may increase their environmental benefits further. And as electricity becomes cleaner (which it is already happening), the difference between them will only grow — cementing electric vehicles’ role in cutting global warming emissions.

Life cycle-based policies are relevant for internal-combustion-engine and electric vehicles as well. The effect of light-weighting on life cycle emissions demonstrates that there are cases where achieving lower emissions during the operation of a vehicle through light-weighting materials could lead to significant increases in life cycle emission. Hence, it is crucial to think about the actual reactions and trade-offs when trying to achieve total life cycle emissions reductions, even for conventional cars.

The LCA approach may also be used as follows: i) to provide a platform by which vehicle manufacturers can engage in carbon footprint discussions (since the formulation of an LCA forces them to systematically engage in a discussion of essential assumptions, variables, and relationships); ii) to emphasise the most important relationships that may require a more thorough investigation before implementing battery end-of-life policies and recycling techniques; and, iii) to illustrate and communicate direct and indirect global warming impacts to policymakers, users, and other stakeholders.

5 References

[1] https://www.energy.gov/eere/electricvehicles/electric-vehicle-basics

[2] de Bortoli, A., & Christoforou, Z. (2020). Consequential LCA for territorial and multimodal transportation policies: method and application to the free-floating e-scooter disruption in Paris. Journal of Cleaner Production, 273, 122898.

[3] https://its.ucdavis.edu/wp-content/uploads/The-Importance-of-Life-Cycle-Assessment-in-Evaluating-the-Environmental-Performance-of-Future-El.pdf

[4] Hoekstra, A. (2019). The underestimated potential of battery electric vehicles to reduce emissions. Joule, 3(6), 1412-1414.

[5] Strømman, A. H. (2013). Comparative environmental life cycle assessment of conventional and electric vehicles.

[6] Archsmith, J., Kendall, A., & Rapson, D. (2015). From cradle to junkyard: assessing the life cycle greenhouse gas benefits of electric vehicles. Research in Transportation Economics, 52, 72-90.

[7] Yuksel, T., Tamayao, M. A. M., Hendrickson, C., Azevedo, I. M., & Michalek, J. J. (2016). effect of regional grid mix, driving patterns and climate on the comparative carbon footprint of gasoline and plug-in electric vehicles in the United States. Environmental Research Letters, 11(4), 044007.

[8] https://greet.es.anl.gov/

[9] IEA (2020), Global EV Outlook 2020, IEA, Paris https://www.iea.org/reports/global-ev-outlook-2020

[10] https://www.rff.org/publications/explainers/carbon-pricing-201-pricing-carbon-electricity-sector/

[11] Ambrose, H., Kendall, A., Lozano, M., Wachche, S., & Fulton, L. (2020). Trends in life cycle greenhouse gas emissions of future light-duty electric vehicles. Transportation Research Part D: Transport and Environment, 81, 102287.

[12] https://ec.europa.eu/clima/policies/transport/vehicles_en#tab-0-1

[13] D. Gohlke and Y. Zhou. (2020) ​“Impacts of Electrification of Light-Duty Vehicles in the United States, 2010 – 2019,” Argonne National Laboratory, Lemont, IL USA, ANL/ESD-20/4.

[14] EC (2014), Frequently Asked Questions on Directive 2006/66/EU on Batteries and Accumulators and Waste Batteries, http://ec.europa.eu/environment/waste/batteries/pdf/faq.pdf

[15] https://ww2.arb.ca.gov/resources/documents/lcfs-pathway-certified-carbon-intensities

[16] https://www.linkedin.com/pulse/astongate-fake-emission-figures-embattled-carmaker-sock-liebreich

Our BUILT Substack Newsletter

Join 27,000+ others. Short, fascinating engineering & infrastructure posts.

Once per week

1 Overview of the Article

This article is written to give an overview of the stages involved in executing a pipeline project. There are different stages in executing a pipeline project; the construction and installation stages are the most visible. However, there are fundamental stages (Feasibility Studies and Conceptual Design) that must be executed appropriately before the detailed design and construction activities.

The Feasibility studies and conceptual design stage of a pipeline project are the preliminary stages of a pipeline project; they are the project’s planning stage.

While the feasibility studies focus more on the project’s viability, the conceptual studies or conceptual design tend to drive the technical ideas in executing the pipeline project.

This article will describe various activities performed during the conceptual design and feasibility studies stage.

In summary, this article will dwell on feasibility studies and conceptual design of a pipeline project. Most of the emphasis will be on the technical aspect. However, some aspects of the economic studies of a pipeline project will be explained.

Figure 1 Ongoing Pipeline Construction

Figure 1: Ongoing Pipeline Construction

2 Introduction

Embarking on a pipeline project is a rigorous task that must be well planned. Some pipelines traverse hundreds to thousands of kilometers across land and water bodies with various obstacles encountered along its routes.

In West Africa, there various ongoing and successfully executed pipeline projects.

The West Africa Gas Pipeline (WAGP) was conceptualized, designed, and installed to transport Natural Gas from Nigeria to Benin Republic, Togo, and Ghana. The pipeline was planned to supply gas to power plants and industries. The pipeline is 678Km in length and can transport 474MMSCF/Day of gas. The pipeline traverses both land and water as it travels along its route. From Itoki to Lagos beach is approximately 56km in length and is 30” in size. The remaining 569Km is 20″ in diameter and travels offshore from Lagos across the Benin Republic, Togo, and Ghana (https://www.wagpa.org/the-wagp/)

The Ajaokuta – Kaduna – Kano (AKK) Gas Pipeline is a 40” pipeline project undergoing construction as of 2020 in Nigeria. The AKK Pipeline is a section of the Trans Nigeria Gas Pipeline (TNGP) planned to transport gas from the southern part of the country to other regions. The AKK pipeline length is approximately 614Km, starting from Ajaokuta (middle Belt) to the Northern part of Nigeria. The pipeline will serve as a source of gas to power plants and other industries.

There are other pipelines transporting products, including Crude oil to various refineries, refined products to storage and distribution facilities, LPG to storage and distribution facilities.

From the few projects highlighted above, it can be deduced that typical pipeline projects are massive and cost millions to billions of dollars.

The physical execution (construction) phase of a pipeline is the most “visible” stage of a pipeline project; however, other activities must be executed before construction. These activities entail rigorous planning and preliminary design activities.

Typical stages of a pipeline project are feasibility studies, conceptual design, Front End Engineering Design (FEED), Detailed Engineering Design (DED), Fabrication Construction and installation, Commissioning, Operation, and Decommissioning. In some cases, there can be stages such as pre-feasibility studies, Pre-FEED depending on client requirements. The pipeline operation and decommissioning phase are mostly not part of the pipeline project stages. However, they are included because they must be appropriately covered in the pipeline’s planning and design stages.

Among all the stages of the project mentioned above, two stages are critical but mostly not heard of during the execution of a pipeline project. These stages are the Feasibility Studies and the Conceptual design stage.

3 Stages of a Pipeline Project

Though the article’s primary focus is feasibility studies and conceptual design, for clarity, below is a summarized description of all stages of a pipeline project mentioned in Section 2 above. It should be noted that a project does not necessarily need to pass through all the stages mentioned. In some cases, the Conceptualization stage is fused into the feasibility studies, with all conceptual design activities embedded in the feasibility studies. It is challenging to perform feasibility studies without performing key conceptual design activities because the conceptual design output data are used for cost estimation and determination of the project’s feasibility. The company may decide to perform Pre-feasibility studies before embarking on feasibility or conceptual studies. This is used to determine if the project is profitable.

3.1 Feasibility Studies

The feasibility studies aim to establish that the project is achievable, technically and economically. At the end of the feasibility studies, the most economically viable route option and pipeline diameter is selected. The client may perform the feasibility studies if they have the in-house capacity or contracted out.

During the feasibility studies, some of the activities performed include:

At the end of feasibility studies, a report with several attachments is generated detailing all the findings, including economic analysis, to aid decision-making to progress the project into the design stage.

During the feasibility studies, all the available alternatives such as pipeline start point, source of products (Gas, Crude oil, refined products, etc.), possible routings, envisaged customers, envisaged demand for product, are analyzed. At the end of the analysis, options not feasible are discarded. The evaluation of all options should cover the cost impact of each selected option.

At the end of a successful feasibility/conceptual studies, the project progresses into the design phase. Experienced engineers must perform the Technical aspect of the feasibility studies while experienced personnel with sound economic knowledge must handle the commercial aspect.

Note some of the input to be used for the commercial/economic analysis will be provided by the engineers; therefore, executing the cost estimate is collaborative teamwork by Engineers and commercial analysts.

3.2 Conceptual Design

This is the planning stage of a pipeline project. It entails producing ideas that will be used in executing the project. For every idea produced, the advantages and disadvantages are evaluated. The evaluation of the idea is not limited to technical; the commercial impact of the idea execution is critically evaluated.

The conceptual design is the primary design activities performed to minimize project execution errors, minimize cost, properly scope the project, and evaluate its feasibility.

Data gathering is a critical component of the conceptual design stage. These data should include population density along proposed routes, environmental data, reserved areas, gathering information on requirements and regulation covering the project area.

In this stage, preliminary pipeline routes are developed with several options documented for further consideration and review. This project execution stage requires critical brainstorming to device suitable means of executing the project.

3.3 Front End Engineering Design (FEED)

Front End Engineering Design (FEED) is also referred to as Preliminary Design or Basic Design.

Front End Engineering Design (FEED) is performed to bridge the Conceptual Design and Detailed Engineering Design gap.

The FEED utilizes the Concept design as inputs. During the FEED, all conceptual designs are elaborated, and the project detailed documentation commence. Only one of the proposed routes developed, selected after the conceptual design is further investigated and detailed during the FEED. During the FEED execution stage of the project, some of the activities to be performed include

3.4 Detailed Engineering Design

This is the last design stage of a pipeline project. The detailed designed documents are used for the procurement of all items required for the pipeline installation activities. If the FEED is detailed enough, some of the FEED documentation can be issued to prospective vendors, particularly long lead items such as pipes. Documents to be prepared and activities to be performed include:

3.5 Fabrication, Construction and Installation

This is the physical execution of the pipeline project. It encompasses the fabrication of pipes and fittings, clearing ROW, joining pipes, excavating pipeline trench, and installing the pipes.

Steel pipes are welded together and tested as per selected codes and standards.

The installation methodology depends on whether the pipeline is onshore or offshore. There are various techniques used for installing offshore pipelines. These are S-Lay, J-Lay, Towing or Reeling, while open cut, directional drilling, and non-directional drilling may be used to install buried onshore pipelines.

3.6 Pipeline Commissioning

Pipeline commissioning entails bringing the installed pipeline into service. When a pipeline is commissioned, it means the pipeline is ready for the transportation of products.

3.7 Pipeline Operation

Pipeline operation entails the efficient transportation of the product from the source point to its destination. All operating philosophies developed during the design stage are adhered to. Pipelines with a sound control system can be efficiently operated and monitored in a control room.

3.8 Pipeline Decommissioning

Decommissioning entails taking the pipeline out of service. Various procedures and plans are developed and followed to take the pipeline out of service.

4 Activities Performed During Conceptual Design/Feasibility Studies

This section will explain some of the activities performed during the feasibility studies and conceptual design of a pipeline project. To achieve a better economic judgment of the feasibility studies, I have decided to fuse the studies’ conceptual design activities.

It should be noted that there is no defined level of detail required for feasibility studies and conceptual design. However, the design must be good enough to be used for the pipeline economic analysis.

4.1 General Considerations

4.1.1 Source of Products (Gas, Crude Oil or Refined Product)

The idea of executing a pipeline project originates from transporting a product such as natural gas, refined products, and crude oil from one source to another.

All possible sources of the product are critically evaluated. If the intention is to import refined petroleum products into a country, all source points such as seaports, import berth platforms, and production reception facilities are evaluated. The evaluation is based on the product’s availability and the product’s cost at the source point.

4.1.2 Destination of the Product

The destination where the products will be transported is adequately defined. This location is based on different factors and the purpose of transporting the products, i.e., local consumption, processing or refining, storage etc.

If the pipeline is built to transport products for local consumption, a determinant factor is an available market. A detailed market analysis is performed that will aid the decision of the product destination. Premium motor spirit (PMS) demand is high in densely populated cities; therefore, a feasible destination for the product is a populated city.

If regulations restrict the storage of a product such as LPG in a city, its destination should be outside the city.

If the intention is to export crude oil, factors should include available export facilities such as seaports, existing crude export facilities etc.

4.1.3 Define the Means of Transporting the Product

Various options for transporting the product, such as rail transportation, road transportation or pipeline transportation, are evaluated. For average to long-distance transportation of petroleum products, a pipeline is the most feasible means of transportation.

4.1.4 Selection of Codes and Standards

The codes and standards’ selection process entails a detailed revision of country requirements, local regulations, requirements, the terrain of the pipeline, etc.

Pipeline transporting liquid hydrocarbons on land may be designed and constructed as per ASME B31.4 (Pipeline Transportation System for Liquids and Slurries), PD 8101-1 (Code of Practice for Pipelines; Part 1: Steel Pipelines on Land), while those transporting gaseous hydrocarbon may be designed as per ASME B1.8 (Gas Transmission and distribution piping Systems), PD 8010-1.

Offshore pipelines may be designed and constructed as per API RP 1111 (Design, Construction, Operation, and Maintenance of Offshore Hydrocarbon Pipelines (Limit State Design), DNV-OS-F101 (Submarine Pipeline System).

4.1.5 Define Required Facilities

A pipeline is not a stand-alone facility. It is usually connected to other facilities such as reception facilities, storage facilities, metering facilities, pigging facilities. The conceptual design should take into consideration all these facilities and how they impact the pipeline.

4.1.6 Analyze Project Impact on Community/Environment

A preliminary project impact study should be conducted. This is not the Environmental Impact Assessment (EIA) that should be performed in further project stages.

4.1.7 Identify all Stakeholders

Stakeholders in this contest do not mean the companies that own or operate the pipeline. Stakeholders are organizations/persons that can affect the project. Some of the stakeholders include:

4.1.7.1 Products Suppliers

They are a major stakeholder because the availability of the product affects the economics of the pipeline. Therefore a concrete agreement such as a product supply agreement must be reached with the supplier to guarantee product availability.

4.1.7.2 Government

Government is a major stakeholder. Therefore the government at the federal, state, and local levels must be involved in the planning and execution of the pipeline. The company should be aware of current government policies and envisaged future policies that can affect the project.

4.1.7.3 Ministries and Regulatory Agencies

Though the Ministries are part of the government, I decided to separate it because they play a key role during the planning and the execution of the pipeline project. Pipelines will not run entirely on fallow land, they cross rivers, roads, railways etc. therefore, all the responsible ministries, including the ministry of transportation and water, must be involved in the pipeline project planning. The ministries give final approval of the pipeline routing or recommend alternative routing; therefore, they must be part of the planning process.

4.1.8 Local Communities

The communities around the pipeline ROW are major stakeholders because the pipeline permanently resides in the community during its operational years. There must be a good agreement with communities along the entire pipeline proposed route. Pipeline vandalization is a significant problem. Therefore appropriate agreement must be reached with these communities to ensure that the pipeline is safe.

4.1.9 Other Stakeholders

Other stakeholders that may be directly or indirectly involved in the planning process are those the pipeline will temporarily or permanently affect their activities. During construction activities, there might be disruption to the movement of cars. Creating ROW access might affect farmers; therefore, all these persons must be informed of the pipeline’s effect on their activities.

Also, owners of existing pipelines, cables and other facilities that will be crossed or affected must be adequately informed and carried along during the planning and the execution of the project.

5 Selected Activities Performed by Various  Disciplines

During the conceptual design or feasibility studies, design activities are performed by various disciplines. The process and the pipeline discipline are the key drivers; however, instrumentation and control discipline and electrical discipline provide considerable inputs.

Below are some of the key activities performed and documentation generated.

5.1 Process Discipline

Some of the activities performed by the process department include:

5.1.1 Throughput Estimates

The throughput is based on estimated demand and the planned volume of products transported from the source. After the demand is estimated, the actual quantity of products available for evacuation is calculated. The volume to be evacuated is the operating throughput of the pipeline. A margin is usually added to the operating throughput. This is referred to as the pipeline design throughput. Throughput estimation should also take into consideration future increase.

For clarity, below is an example of how to estimate pipeline throughput. I have assumed the research for product demand has been performed.

Company XYZ intends to evacuate 500,000 (Five Hundred Thousand) barrels of crude oil from its storage facility (tank farm) in a day. However, increasing the tank farm’s storage capacity by 50% in the future is possible. The company intends to evacuate 50% of the product by land and the remaining 50% by sea. Of the percentage to be evacuated by land, the company intends to transport 60% of the product by pipeline due to distance to the country’s northern part. However, the remaining 40% will be transported by rail/trucks to a refinery a few kilometers away.

Present Tankfarm Storage Capcity = 500,000 barrels

Future Tankfarm Storage Capacity = 1.5 x 500,000 = 750,000 barrels

Quantity of products to be evacuated by Sea = 0.5 x 750,000 = 375,000 barrels/day

Quantity of products to evacuated by land = 0.5 x 750,000 = 375,000 barrels/day

Quantity of products to be evacuated by rail/trucks = 0.4 x 350,000 = 150,000 barrels/day

Quantity of products to be evacuated by pipeline = 0.6 x 350,000 = 210,000 barrels/day

This implies future operating throughput = 210,000 barrels/per day

Giving a 10 percent margin for design throughput

Design Throughput = 210,000 x 1.10 = 231,000 barrels/day

Therefore, the pipeline must be sized to satisfy a throughput of 231,000 (Two Hundred and Thirty-One) barrels/day.

5.1.2 Pipeline Hydraulic Analysis

Pipeline hydraulic analysis is performed to determine the optimum pipeline size to meet the required throughput. The pump head is required to transport the product from the start point to the destination.

Liquid hydrocarbon pipeline pressure loss can be predicted using the Darcy correlation methods.

Other equations that can be used to estimate pressure loss in liquid hydrocarbon pipelines include:

Modified Colebrook-White Equation, Hazen-Williams Equation is mostly used for a pipeline transporting refined products pressure loss calculations.

Gas pipeline pressure drop can be estimated using the American Gas Association (AGA), Modified Colebrook-White Equation and other available equations.

Software is generally used for hydraulic analysis. However, at this stage, spreadsheets developed in-house can be utilized.

The estimated pressure drop will determine the number of pump stations or compressor stations along the pipeline.

5.1.3 Prepare a Process Flow Scheme for the Pipeline

The flow scheme should show the pipeline characteristics such as diameter, metering stations, block valve stations, pig traps, off-takers etc.

5.1.4 Process Description

The process department must give a clear description of the entire pipeline system. All the equipment required along the entire pipeline facility must be clearly stated.

Process description should clearly define

5.2 Pipeline Discipline

The pipeline department performs activities including

5.2.1 Pipeline Routing

Pipeline routing is performed to determine optimum pipeline routes. Various routes are developed, but most times, three options are developed to aid easy decision making. See below an example of a pipeline route developed using satellite imagery.

Figure 2 Example of Pipeline Route

Figure 2: Example of Pipeline Route (For Illustration Purpose, Wrong Coordinates)

The routes are developed through a desktop study, utilizing various software or data. Routing is performed utilizing satellite imagery, which may be bought or provided in the software.

One of the most widely used software is google earth. Other software includes ArcGIS, QGIS etc.

Google earth can be used to obtain coordinates of desired locations on the proposed routes. The software also provides elevation information that can be used for preliminary pipeline planning and can be used to visualize the level of geographical development over time. This can be used to predict future development along the pipeline route.

Also, features such as roads, railways, rivers, mountains, reserved areas etc. can be easily identified on google earth.

When pipelines are traversing water body’s critical information can be obtained from Admiralty Charts. These charts give detailed information about the location of offshore infrastructures, including pipelines, cables etc. They also give information on the location of the wreckage, anchoring zones, seaports etc.

Most importantly, the depth of water at a specific location is shown on admiralty charts. It should be noted that updated versions of the chart should be obtained during the conceptual design stage.

The information obtained from all software and admiralty charts is only utilized for the conceptual design. Detailed surveys and investigations are required as the project progresses into the FEED stage.

When developing the routes, some of the criteria’s to consider include:

5.2.2 Identify Obstacles along Proposed Routes

During this stage of the project, identifying obstacles should be performed and factored into the cost estimates. Visible obstacles such as river crossings, road crossings, railway crossings and locations that will require special technology to install pipeline should be adequately defined.

Most of these obstacles can be easily spotted on satellite imagery. If necessary, a site visit can be performed to define obstacles of interest appropriately. A table or an attachment of identified obstacles should be prepared. This table should show the coordinates of these obstacles, the type of obstacle, the length of the obstacle and the proposed method of crossing,

If not identified, these obstacles can lead to large variations in the cost estimate as the project progresses.

5.2.2.1 Comparison of Identified Routes

After all routes and obstacles have been identified and documented, a table of comparison should be prepared to show each route’s properties. Below is a tabular comparison of three routes.

Comparison of Identified Routes

5.2.3 Preliminary Wall thickness Calculation

The wall thickness is a critical activity that is performed during the feasibility studies and conceptual design. A large percentage of pipeline project results from the procurement of pipes and fittings. Therefore the wall thickness must be estimated during this project stage. The wall thickness is calculated as per the selected codes and standards; however, the wall thickness will be optimized as the project progresses. It is better to be conservative in estimating the wall thickness during this stage of the project.

5.2.4 Develop Pipeline Facility Concept

The pipeline department should develop a facility concept in conjunction with the process department. The concept should take into consideration pipeline construction methodology.

Some of the concept to develop include

5.2.5 Prepare a Preliminary Pipeline MTO

The pipeline discipline prepares an MTO covering the entire pipeline system. When there is more than one route option, the MTO for each option must be prepared. The MTO will be used in estimating the cost of the pipeline materials.

5.2.5.1 Define Pipeline Material and Grade

The Line pipe material and the grade should be specified during this stage of the project. The grade will be used in the estimation of wall thickness. The material may not change as the project progresses; however, the pipe grade may change. Pipe material grade may change because there might be a need to use grades that result in thinner or thicker wall thickness for offshore pipelines and reduce weight because of higher transportation cost and technical reasons resulting from stress-related issues. Most pipelines are constructed of API 5L pipe materials, with grades ranging from Gr. B to Gr. X120.

5.2.5.2 Develop Preliminary Pigging Facilities

The pipeline engineer should select a location for pig launchers and receivers. If intermediate pigging stations are required, this should be well documented because they will add significantly to the project’s cost. The coordinates of these locations are tabulated in the report.

5.2.5.3 Pump or Compressor Stations

Pipeline traveling long-distance required intermediate pump stations or compressor stations to boost the pressure. The process department will specify the number of stations required. However, selecting the location should be done by a joint team of the process and pipeline engineer. All the locations and coordinates should be indicated on the routes.

5.2.5.4 Metering Stations

All metering stations along the pipeline route should be adequately defined with their coordinates documented.

5.2.5.5 Define Pipeline Inline components Fitting and Flanges

The class rating of all fittings should be defined, locations of other inline components such as isolation joints should be documented.

5.2.5.6 Line Break Valve/ Block Valves Station

The pipeline department should define the location where sectionalizing valves will be located along the entire route. The locations should be shown on the route maps and the coordinates documented in the report.

5.2.5.7 Corrosion protection

The pipeline department should also specify the type of corrosion protection for the pipeline. Also, the type of external coating for the pipeline should be specified.

5.2.5.8 Pipeline Construction

This is very critical as construction activities contribute significantly to the cost estimate. The envisaged construction method for sections of the pipeline should be specified. If unique installations are required for roads, rivers or rails, this location should be documented with the envisaged construction method.

The inability to predict the construction method can result in significant construction cost changes because special construction technology such as horizontal directional drilling can significantly increase the pipeline project’s cost.

5.3 Instrumentation and Control

The I&C department is responsible for developing the pipeline instrumentation and control system concept. This should be part of the final report. Also, an MTO covering the entire system should be developed.

The control system should describe how all instruments installed on the pipeline will communicate with various control systems; how the information will be accessed, processed, and transmitted.

At this stage of the project, the envisaged system architecture should be developed to improve as the project progresses.

The components of the control system should be adequately explained in the report. Typical examples of components of a control system that should be part of the report are:

5.3.1 SCADA System

The SCADA system monitors and control the pipeline facilities in a timely manner and provide a centralized alarm, event management, operation and management reports for the entire pipeline facilities. The SCADA system also ensures proper pipeline shut down by closing pipeline facilities in a planned manner in an emergency.

5.3.2 Station Control System

All stations, such as pigging stations, metering stations, and block valve stations, should have a control system developed with their programmed algorithms assuring the pipeline’s safe operation. The I&C department should give a detailed report on how to integrate the entire stations.

5.3.3 Fail Safe System

The Fail-Safe System, which may contain the fire and gas system and emergency shutdown system, should be adequately detailed in the report.

5.3.4 Process Instrumentation

The report should detail the process information gathering devices. Some of the process information that requires gathering and monitoring in a pipeline system are pressure temperature, flow rate, density, pig detection.

5.3.5 Telecommunication System

The report should give detailed information on the overall network topology and the network components.

5.4 Electrical Department

The feasibility/conceptual design report should have inputs from the electrical department. The inputs should cover power requirements for facilities that are part of the pipeline system, such as pump or compressor stations, block valve stations, metering stations.

Also, components of the entire power system should be documented appropriately.

A preliminary MTO covering the entire electrical system should be developed. This will form part of the cost estimate.

6 Commercial/Economic Analysis

6.1 Budgetary Cost Estimate

Based on the conceptual design, a cost estimate is prepared. A separate estimate should be prepared for each route and pipeline diameter.

The estimate may cover both CAPEX (Capital Expenses) and OPEX (Operating Expenses)

Competent persons should prepare the estimate. The persons should have access to data containing the cost of items in the MTO prepared by each department.

The budgetary estimate should include design, engineering, procurement, construction, testing and inspection, and commissioning of the proposed pipeline.

The cost estimate may be based on in-house cost data; the items’ cost may be sourced from vendors. When data are sourced from vendors outside the country, Increased cost resulting from import duties and transportation should be factored into the estimate.

Usually, the cost estimate’s accuracy is per the recommendations of AACE (Association for the Advancement of Cost Engineering). Kindly refer to AACE Recommended Practice No. 18R-97 for more information on cost estimation and accuracy.

Usually, a class 4 estimate is sufficient for this stage of the project.

Based on the cost estimate output, only one option is selected. This option covering pipeline diameter and the selected route will be further elaborated in the FEED stage.

At the end of the estimate, a detailed estimate for each option is presented in tabular form, and a summary of each option is also presented.

Below is an example of a budgetary cost estimate summary.

CAPEX ESTIMATE

6.2 Market Analysis

Market analysis is a key component of feasibility studies. It is performed to determine the viability of the project. This is performed to determine the rate of demand for the product, the size of the market and how long the market size and demand can be sustained. The output of this analysis is included in the feasibility study report.

7 References

The West African Gas Pipeline (WAGP): https://www.wagpa.org/the-wagp/

Ajaokuta – Kaduna – Kano Pipeline: http://oilservltd-ng.com/olmls/AKK2.php

18R-97: Cost Estimate Classification System – AACA

Our BUILT Substack Newsletter

Join 27,000+ others. Short, fascinating engineering & infrastructure posts.

Once per week

Drilling Rigs, Engines, & Fuels

Introduction: Drilling Rigs, Engines, & Fuels

High-tech, adaptive, and efficient, the oil and gas industry constantly seeks to improve all aspects of the value chain. Whether up, mid, or downstream processes, all undergo continual refinement. Upstream production is perhaps the first to explore and pioneer developing technologies. Sites located onshore and offshore increasingly use smarter, cost-cutting engines and fuel sources that are resistant to price fluctuations. Biofuel and dedicated natural gas engines are regularly employed in exploration and production efforts throughout the energy industry.

Often the choice to use field gas, pipeline gas, compressed natural gas (CNG) or liquefied natural gas (LNG) hinged on logistics related to distance and transportation. An agile natural gas industry, growing infrastructure, and the rapidly expanding availability of inexpensive hydrocarbon gases have virtually eliminated the downsides of drilling rigs fueled partially or entirely by natural gas. LNG fueled drilling rigs are now a timely turnkey solution for producers around the globe. Below we explore the critical aspects of upstream production and the vital components of drilling rigs that make it all possible.

1  Upstream exploration and development

At the root of most modern processes is knowledge. Oil and natural gas exploration rely on the most advanced information models used by geologists and other scientists. Geographic information software (GIS) may be used to model vast amounts of information. Biology, chemistry, and physics are key disciplines used with geology for resource exploration. Possible locations for hydrocarbon deposits, reservoirs, or other geologic formations are found through applying one or several advanced methods. Once determined as a possible site for oil and natural gas development, teams must address property and mineral rights and subsequently begin exploratory measuring, scanning, and drilling operations. This early part of hydrocarbon production lays the foundation for choosing appropriate drilling rigs, engines, and fuels.

Scientists begin exploration at the highest level of conceptualization. This helps eliminate areas that contain hydrocarbons at concentrations below commercial value. Extracting resources from these locations would prove too expensive with current technologies. Formations which trap hydrocarbons are well understood by scientists. Using geologic modelling exploration teams may narrow down reservoir locations without leaving their laboratories. This ‘type’ of exploration has been employed since the early days of oil exploration. Today’s geologists have built on these early concepts and ideas. Incorporating biology aids in determining what varieties of plant and animal life resided within a given area. Knowing this allows exploration teams to anticipate where hydrocarbons reside within a specific geography, including subsea environments.

Applying geophysics disciplines to exploration is also standard practice. Among these disciplines are geodesy, gravity, hydrology, magnetism, meteorology, oceanography, radioactivity, seismology, and volcanology. Seismology is perhaps the most used of these. This discipline studies the propagation of waves as they travel through layers of earth. Exploration teams employ a variety of seismic programs. Dynamite, vibration pads, or other sources are used to generate seismic waves. These waves travel through some layers and formations while bouncing off of others. Measurements of speed and reflection are taken. That data is analyzed to map the subsurface.

Once a reservoir is located, mineral rights and leases must be sought. The initial aim of exploration efforts at this stage is to drill a test well. Before drilling a test well, it is necessary to consider the surrounding lands, should the well produce. Additional wells would likely follow. If a company does not take the initiative to lease not only mineral rights but the necessary surface land leases, another company would be able to drill the adjoining land. Ideally, landsmen responsible for arranging these rights would tie up all of the land covered by the exploration team’s prospect.

Surface rights on a site are secured before drilling licenses are applied for. Depending on the needs of the surface site, the surface lease could be less than 1 hectare (2.5 acres). Larger sized surface leases are required for roadways, easements, and sometimes to tie in the well to pipeline systems. For multi-well sites that employ horizontal directional drilling, it is common for surface leases to exceed 6 hectares (15 acres).

Multiple wells drilled in this fashion significantly reduce the required operating space. As a result, the environmental impact is reduced. Impact assessments and public consultations are frequently a part of this process. These assessments include archaeological, environmental, wildlife, and other assessments. Once concluded, the complex process of drilling and completing a well begins, generally with choosing the site requirements, rigs, power sources, and other vital components of hydrocarbon production. Though similar in many respects, onshore and offshore production sites have many differing requirements.

2  Offshore platforms: Drilling Rigs, Engines, & Fuels

The earliest offshore platforms were built in the 1890s, just before the turn of the 20th century. Initially, they were little more than piers extending from onshore well pads. The first steel-pier island was an early forerunner of today’s highly sophisticated offshore platforms. Built ½ mile offshore with a 25-ft air gap, this steel island suffered from poor well production. 8 years after its initial construction, the prototype offshore platform was destroyed in 1940 by a storm. While early pier-platforms were built off of the California coast, on-water drilling took place in the swamps of Louisiana.

Rectangular, shallow-draft barges were constructed for this purpose. Tugs pulled them into place, where they were often submerged. Submerged barges were outfitted with lattice steel structures, allowing later barges to post in deeper waters. Often, pilings were used to prevent drift or movement due to waves and wind. By 1947 the first offshore tender assist drilling (TAD) unit was mobilized out of sight from land, around a 6-meter depth, in the Gulf of Mexico. It was equipped with the necessary drilling equipment set that typifies drilling rigs.

As companies progressed into deeper waters, platform designs and capabilities took off. Dozens of jacketed, submersible, moored tension leg and floating designs flourished. By 1978 jacketed-support platforms were installed at nearly 400-meter depths. Typically, floating designs, submersibles, and semi-submersibles are used for deep waters. Some offshore platforms are designed to reach reservoirs several thousand meters below the surface. These long wells may be drilled from drillship, fixed jacket, or templates installed on the seabed.

All offshore platforms require the equipment necessary to process and safely handle the conditions of hydrocarbons produced from these reservoirs. Deepwater platforms will contain quarters, recreation, and other facilities for the operators. At moderate depths, it is typical to construct a variety of platforms to accommodate the crew or serve other necessities. An offshore complex can have platforms for production, living, riser, satellite, wellhead, and flaring purposes. These platforms are connected by bridges, subsea cables, and infield pipelines. Depending on the platform’s location, it may be connected to an onshore processing unit.

Drilling Rigs, Engines, & Fuels

3  Drilling rigs: Drilling Rigs, Engines, & Fuels

Among the most iconic of sights associated with oil production is that of the drilling rig, usually the derrick at the centre of a well pad or the unmistakable form of an offshore drilling platform. Drilling rigs are always designed for either onshore or offshore applications.

3.1  Background

Custom designed for a wide variety of needs; onshore drilling rigs come in a variety of sizes. They may be portable, small, medium, or large-sized. Some drilling rigs are customized for mining or other industries. Classifications for onshore drilling rigs include the categories of height, drilling method, derrick position, a pipe used, the power used, and directional drilling. Perhaps counter-intuitive, drilling rigs have an extensive history of use.

Long before modern, engine-powered rigs were developed, pioneering Chinese developed the earliest known forms of drilling rigs to extract natural gas. As early as 500 B.C. Han Dynasty China used rotary and percussion drilling with iron bits to produce oil and natural gas. Derricks were constructed from bamboo poles while bamboo fibres provided a capable drill string. These early drilling rigs were initially capable of reaching depths of ten meters.

As improvements were made, bamboo drilling rigs in China reached depths of 100 meters. Later versions were capable of reaching nearly 700 meters. Drilling rigs made throughout these periods were man-powered using levers and teams of men. 16th Century Chinese drilling rigs would first be succeeded in technological development by 19th-century rigs which used steam engines as their primary power source. Drilling rig derricks were primarily made of wood, while percussive drilling with cables was the norm. Cable tools were quickly replaced with rotary drill bits, providing exceptionally faster drilling times as well as the capability to reach greater depths.

At the turn of the 20th century, the U.S. oil boom began with a blowout in Beaumont, Texas. Hundreds of feet of oil soared skyward. Rotary bits, drilling mud, and steam-powered rigs were assembled in a frenzy. More than 1,500 companies were created as tens of thousands of Americans flooded into town. Oil was in. A new era of energy production was underway from 1901. World War I only increased the demand for this reliable energy source. This flood of producers and workers generated a tremendous variety of improvements to drilling rigs and the practice of hydrocarbon production. From 1900–1950 the blowout preventer (BOP), steel derricks, drill bit advancements, offshore drilling rigs, and early horizontal drilling techniques were created. Hosts of improvements in efficiency, effective products, and safety arose simultaneously. The second half of the 20th century only furthered the fantastic strides in technology and techniques used for hydrocarbon exploration and production.

Drilling rigs traded their steam-powered operations for combustion engines in the 1950s. By the 1970s, these engines powered multiple on-site generators. Bottom-hole assemblies, or drill bits, became more advanced. Operators gained the ability to steer drilling systems with greater accuracy. Tracking downhole drilling operations became more sophisticated with measuring and telemetry equipment. These improvements were pioneered to allow production teams to reach previously inaccessible reservoirs while increasing production rates. Paired with techniques such as hydraulic fracturing or other methods of well stimulation would eventually lead to precise, reliable horizontal directional drilling technologies in the early 21st century.

Within the last two decades, oil and natural gas producers have combined advancing technologies from far-flung disciplines to create highly efficient, effective, and safe drilling systems. The modern drilling rig is a custom engineered masterpiece of design. These drilling rigs are at the core of today’s global energy renaissance, the U.S. Shale Revolution.

One effectively designed drilling rig is capable of drilling multiple wells from a single well pad. Drilling is easily planned, controlled, and monitored using computer software, while operated from climate-controlled environments. Many drilling rigs are equipped with hydraulic ‘legs’ which allow the rig to ‘walk’ across a good pad to a new well site. It is difficult to overstate the impact of these massive and rapid advancements in drilling rig technologies.

2019 10 30 2 31 13asd

3.2  Drilling rig classifications

Because a large variety of drilling rigs exist to serve a broad range of scenarios, many delineations exist for describing them. Exploration teams, well pad engineers, operators, and other experts require these classifications to choose the proper drilling rig for a given production goal. Drilling rigs may be designed for use with a singular drilling technology or with the ability to change and combine technologies to achieve their ends. Classifications based on height, derrick position, directional or horizontal drilling, mobility, drilling methods, drill pipe, ultimate drilled depth, or by power type are common.

3.3  Onshore drilling rigs

As the prototypical drilling rig, onshore rigs may appear simplistic in comparison to their offshore counterparts. While offshore drilling rigs share many similarities to onshore rigs, there are key differences. Onshore drilling rigs are by definition land-based. They are capable of drilling shallow, deep, extended reach, vertical, and deviated wells. Ground transportation is most often required to move these rigs to their destinations. Reliability and ease of handling are highly prized with onshore drilling rigs. As operating rates are expensive, the ability to quickly move, rig up, and rig down is essential. More often than not the physical location and required drilling depth impact the size and chosen drilling equipment for land-based drilling rigs.

Land-based rigs are typically separated into the classifications of conventional or mobile. Conventional drilling rigs are equipped with load-bearing derricks, which are designed to remain anchored to the corners of a substructure throughout drilling operations. These rigs are generally larger, designed to house drill pipe sections of a greater length than exploration or finishing rigs. Land-based rigs of conventional design, despite the implication of their name, maybe equipped with hydraulic legs. So equipped, they can move around a good pad with little assistance.

Onshore rigs may also be classified as mobile when mounted to wheeled trucks or readily transported by truck in a modular form. Mounted in this fashion, mobile rigs may be further classified by the type of mast, whether cantilevered, bootstrap, telescopic, folding, or otherwise.

Drilling Rigs, Engines, & Fuels

3.4  Offshore drilling rigs

Platforms or vessels that function offshore are an iconic sight, inseparable from association with oil and natural gas. Partly because of their size and location, these drilling rigs are sometimes viewed with a sense of arcane wonder. The myriad of complex operations required to construct, transport, and anchor them would be enough to deter most casual onlookers from investigating them. In addition to these operations, offshore drilling platforms are increasingly capable of carrying out upstream processes within the oil and gas value chain. Offshore platforms can explore, drill, and extract hydrocarbons. Many offshore rigs process, store, and transport these resources as well. Finally, these marvels of modern engineering must accommodate the crews that carry out work on them.

Offshore drilling rigs are designed in dozens of ways. Ultimately their design is dependent on the environment they operate within. If operating within lakes, inshore waters, or inland seas, offshore platforms may be fixed to the ocean floor. Platforms that operate further offshore or in deep waters are more likely to consist of an artificial island, be partially or completely submersible, or take the form of a marine vessel.

Engineering for and operating in oceanic environments has long presented some of the most challenging conditions for human endeavours. Producing and transporting hydrocarbon resources from beneath the ocean floor certainly qualifies as a challenging situation. It is among the most challenging and expensive undertaken in history. Only exceptional design, planning, management, and execution make these operations possible. Even then, the margins for error are virtually non-existent. Choosing the proper solutions at every point is essential to the success of offshore platforms. Accordingly, it should come as no surprise that offshore drilling rigs are among the most complex projects undertaken anywhere on earth.

Adhering to proper design principles and equipment selection is a fundamental consideration. Many of these aspects are tied directly to the operating conditions of an oil rig. Variability in the design and operation of an oil rig extends beyond its immediate operating conditions. Many operational aspects of drilling platforms contain flexible options. The configuration of platform complexes varies considerably from rig to rig, even when operating at similar depths. Subsea systems may be configured on the ocean floor. Additionally, many of the standard drilling rig components (discussed in further detail below) can be selected from dozens of options.shutterstock 1106793482

3.5  Horizontal directional drilling

Perhaps the most catalytic development of the last century within the oil and natural gas industry is the perfection of horizontal drilling techniques. Horizontal drilling was first pioneered experimentally in the early 20th century. Companies as early as the 1920s took note of oil wells that dropped significantly in production and pressure amounts. Though incapable of proving such at the time, some suspected rival companies of drilling horizontally into their reservoirs. Officially, horizontal directional drilling (HDD) became a recognized possibility in legal disputes between production companies.

Originally this technique was considered outright impossible or highly improbable at the least. Horizontal drilling was confined to the category of phantom phenomena until early, niche-practice pioneers in the 1930s demonstrated their ability to drill directional wells. Many decades would pass before HDD became a truly significant source of investment for drilling and production companies. This was largely due to the limitations of technology, materials, and engineering. Many difficulties prevented the regular use of HDD oil wells.

Initially, HDD techniques were employed to deviate a well for simple, functional reasons. Operators during these times would sometimes deviate or dogleg a well to avoid an obstruction. Whether encountering an unexpected geologic formation or avoiding trapped equipment, very few operators could accomplish this demanding feat. The next developments in horizontal drilling took place in the 1970s with the advent of downhole drilling motors. Combining this technology with adequate telemetry systems allowed operators to effectively and reliably steer the direction of a wellbore, regardless of its depth.

Horizontal wells provide several distinct advantages over conventional horizontal wells. Early horizontal wells were used to relieve well pressure in out of control (blowout) oil fields. Modern horizontal wells are drilled to reach locations inaccessible to vertical wells, typically those underneath cities, lakes, or preventative geologic formations. The dimensions of horizontal wells also provide significant benefits to producers. Multiple wells may be drilled from a single, initial well.

Drilling multiple wells from a single well produce a cascade effect in both onshore and offshore drilling environments. Onshore, it significantly reduces the footprint of a well pad. This impacts everything from mineral rights and land leasing to dozens of operational concerns. Only a single wellhead is needed to maintain the production of multiple well paths. Offshore drilling platforms are dramatically impacted by this practice. As many as 40 well paths may be drilled from offshore platforms using horizontal drilling techniques. The net result is much more efficient, less costly, and safer production of oil and natural gas. Combining horizontal drilling with hydraulic fracturing may be the crowning achievement so far in HDD operations.

Unconventional resources, previously inaccessible, are now developed on large scale. Without HDD this would be impossible. The majority of unconventional resources present themselves in horizontal geologic formations. Horizontal drilling alone would not be enough to stimulate commercial production of oil and natural gas from these formations. Recently pioneered, hydraulic fracturing is a good stimulation technique used to produce unconventional resources. High-pressure fracturing fluid is injected through perforations in specially designed, horizontally drilled well casing. Fracturing fluids containing sediments or nanoengineered proppants induce desired flow rates. The combination of these technologies created a renaissance in the energy industry known as the U.S. Shale Revolution. Abundant and reliable natural gas production has skyrocketed to levels previously unimaginable.

3.6  Drilling rig components

At a minimum, all drilling rigs require a handful of principal components. The components include a mast (derrick), blowout preventers (BOP), draw works, drilling, engines, and a mud system.

The mast is the support structure, erected above the well, which allows operators to add and remove drill pipe or equipment into the well. Blowout preventers are a type of valve used to reduce and control erratic or unexpected pressures while the draw works are comprised of hoisting equipment for the rig. An oil drilling rig’s rotating assembly is referred to as the drill string. The rotating Kelly, drill collars, bit, and pipe comprise the drill string.  Power is delivered to all primary and subsystems of the site through the drilling rig engines. Mud systems employ pumps, tanks, a circulating hose, and flow lines.

When considered as systems, these components are grouped into five distinct systems:

Drilling Rigs, Engines, & Fuels

4  Drilling rig engines

Excepting the early usage of steam-powered engines, diesel engines have long been the engine of choice for powering drilling rigs. Sturdiness, reliability, and efficiency are synonymous with diesel engines. Located onsite at well pads and platforms, they typically range from 400 – 3,000 hp. As the sole source of power generation at many production sites, these engines are essential to all drilling operations. Renowned for their steadfast performance, diesel engines maintain their status as the dependable internal combustion engine for drilling rigs.

Though standard diesel engines operate on diesel fuel, modern variants patented as early as 2001 may use several fuel types. Continual refinement of blending kits and engine design has produced highly efficient dual-fuel and dedicated natural gas-fueled engines for drilling rigs. The first drilling operations to utilize prototype natural gas engines produced exciting results. Offshore rigs operating with these prototype natural gas-fueled diesel engines demonstrated savings over 4,000 USD per day. Current dual-fuel natural gas (diesel displacement or biofuel) and dedicated gas diesel engines outstrip those figures. Benefits relating to operational efficiency were accompanied by a reduction of harmful emissions.

In the wake of early, successful experimentation with natural gas-fueled drilling engines, spark-ignited (SI) and turbine engines are now capable of duel-fuel and dedicated gas operation. Though not as widely used as diesel engines for drilling operations, each engine presents advantages and disadvantages for rigs.

SI engines are adequately used to sustain stead loads, typically for electric power generation. Conventional or dual-fuel diesel engines are used to aid SI engines by supplying high transient load response for some drilling operations.

Turbine engines are used for a variety of purposes on drilling rigs. Large turbine engines can be used for both stationary and mobile electric power generation. Smaller turbine engines are frequently used to power hydraulic fracturing pumps. As these engines are highly configurable, they are well suited to use a wide variety of combustible fuels. Turbine engines are capable of dedicated natural gas configurations.

Drilling rig engine configurations include:

Drilling Rigs, Engines, & Fuels

5  Engine fuels

As the exploration and production of natural gas resources have increased, the idea of fueling drilling rigs with field gas, CNG, or LNG has grown in prominence and viability. Diesel fuel remains the dominant energy source for drilling rig engines. Yet the data indicate significant cost benefits and emission reductions for adopters of natural gas-fueled drilling engines. Following the initial success and growing adoptions of natural gas fuel sources, many pioneering companies have emerged to provide LNG to onshore and offshore drilling operations.

5.1  Diesel fueled drilling rigs

Fueling drilling rig engines with diesel fuel is the conventional way, with sound reason. The diesel engine was designed to operate at peak output and efficiency with it. As the standby fuel for generations, systems and processes to transport, store, and use diesel are well established. Marginally, diesel outperforms levels of energy production that dual-fuel retrofits. Despite the obvious benefits of diesel fuel, there are significant upsides for operators that adopt natural gas fueled drilling rigs.

5.2  Natural gas-fueled drilling rigs

Drilling rig engines fueled with the natural gas stand to gain economically and environmentally, through initial adoption can prove costly for some. Natural gas can be supplied as an alternative to diesel in four forms. Field gas, pipeline gas, compressed natural gas, (CNG) or liquefied natural gas (LNG). Generally, transportation and availability play primary roles in deciding which natural gas fuel is the best option for fueling drilling rigs.

LNG is primarily liquefied methane gas, cryogenically cooled to -260 degrees Fahrenheit. Both transportation and storage of LNG fuel is conducted at near atmospheric pressures. Vaporization is required on-site for use in LNG fueled drilling rigs. By contrast, CNG is stored and transported under high pressures in cylindrical pressure vessels. When transportation distances are relatively short, CNG fueled drilling rigs are viable. Modular LNG and CNG facilities are rapidly emerging to provide these services, sometimes referred to as small-scale LNG facilities. Pipeline quality natural gas is a highly desirable fuel source for drilling rigs where available.

Field gas is another greatly appealing form of natural gas-fueled drilling rigs. This ‘wellhead gas’ is locally sourced, has the smallest carbon footprint and the highest reduction in operating costs of all available fuel sources (as much as or exceeding 90% reduction of fuel cost). The composition and quality of field gas may vary greatly from one site to another. Some processing is necessary to fuel drilling rig engines with field gas.

The bottom line for natural gas-fueled rigs is that they reduce operating costs while generating fewer emissions. In particular, reduction of nitrogen oxides and particulate matter.

Drilling Rigs, Engines, & Fuels

5.3  LNG fueled drilling rigs

Pioneered in Texas nearly a decade ago, highly portable and efficient LNG fueling systems for drilling rigs has reached a mature level of development. Turnkey services for fueling, regasification, and storage are readily available for operators. Boasting 50% or more cost reduction that diesel-fueled rigs is difficult to turn down for many companies. Permanent LNG systems have smaller footprints than their conventional equivalents and conversions for equipment are relatively simple. The safety record of LNG, a colourless, odourless, non-corrosive, and non-toxic fuel is without peer. Increases of infrastructure and transportation continue to make LNG fueled drilling rigs more accessible to upstream producers.

As a liquefied form of natural gas, LNG rests at 1/600th of its original volume. Energy-dense and easily stored or transported whether on the grid or remotely located. Mobile storage and skid-mounted, or mobile vaporizers, are simply prepared and brought onsite. Additionally, the price of LNG is remarkably stable in contrast to that of diesel fuel. Average adopters of LNG fueled drilling engines will spend less than half as much per day on fuel.

6  Conclusions

Engine fuels, engines, and drilling rigs themselves are at the fore of producing the world’s energy supply through highly planned, complex projects which aim to operate as efficiently and effectively as they are able. Thorough exploration reveals the precise requirements for a site, whether onshore or offshore. Regardless of location, drilling rigs and their components are continually improving in design and operating practices.

Often these operations are technology-heavy and pioneering, constantly seeking to push the envelope of their exceptional capabilities further. Developing engines fueled by natural gas is the next logical step towards improving these goals. LNG fueled drilling rigs, in particular, offer increasingly significant advantages as a global infrastructure for LNG becomes more plentiful, agile, and inexpensive. Continual discoveries of vast natural gas fields and the growing ability to economically produce unconventional resources all but ensures LNG as the emerging, dominant choice for fueling production operations well into the future.

Related reading

Choosing Between SPM Calm and CBM Mooring

Where Natural Gas Is Found and How It Is Obtained

Single Point Mooring (SPM) Calm Buoy Systems – The Ultimate Guide

Further reading

LNG As Marine Bunkering Fuel

LNG Value Chain – The Basics

LNG – An Overview

The United States Shale Revolution

Hydraulic Fracturing Overview

Horizontal Directional Drilling for Oil and Natural Gas

< BACK TO ARTICLES

Our BUILT Substack Newsletter

Join 27,000+ others. Short, fascinating engineering & infrastructure posts.

Once per week

1 Introduction

Green Hydrogen

Green Hydrogen is one of the core elements of the global strategy to shift to low Carbon, sustainable sources of energy. Hydrogen is unique among fuels, as it produces only Water upon combustion. Further, the Water in exhaust gases from Hydrogen combustion can be recycled by condensation in most industrial and domestic settings. Green Hydrogen is produced by the electrolysis of Water using electricity from renewable  sources. The entire energy production cycle using Green Hydrogen, is therefore cyclic, sustainable and has no Carbon Dioxide emissions. This concept is illustrated in Figure 1.

The momentum of investment in green Hydrogen projects has accelerated in the past few years. In the year 2020, the global installed capacity of Water electrolysis for Hydrogen production was around 300 MW and increased to 500 MW by the end of 2021. The IEA has projected that by the end of this decade, the installed green Hydrogen capacity could  be 720 GW[1]

Given the significance of Green Hydrogen in the future energy mix, this articles provides an overview of the current state of art and provides guidance on choosing the right electrolyser for different types of applications.

2 Water Electrolysis Technology

An electrolyser splits Water into Hydrogen and Oxygen, using electricity. The history of Water Electrolysis may be traced to the early nineteenth century. Michael Faraday, a British Scientist, enunciated the Laws of Electrolysis in 1833 and provided the foundation for future developments in this field. The first industrial model of a Water  Electrolyser is attributed to In the, Dimitry Lachinov, a Russian Physicist who, in the year 1888, invented the concept of bipolar electrodes, using parchment separators in an Iron tank. In the year 1899, at Zurich, Dr O.Schmidt, presented  the first industrial bipolar electrolyser, stacked up similar to a filter press. This design was commercialised by Oerlikon [2]. By the year 1902, more than 400 industrial water electrolysis units were in operation and in 1939, the first large Water electrolysis plant with a capacity of 10,000 Nm3 H2/h went into operation [3].

Most of the Water present on Planet Earth is Sea Water. Due to the presence of Chlorides in Sea Water, large quantities of Chlorine gas are produced during electrolysis. Hence large scale industrial utilization of Water electrolysis initially occurred in the manufacture of Chlorine by Saline Water electrolysis. Hydrogen was seen only as a by-product, which could be used to manufacture products like Hydrochloric acid.

When the intent is to produce only Hydrogen, then present-day electrolysis technology requires the use of demineralized Water. However, this is most economical only if  demineralized Water is produced from freshwater. Major developments in green Hydrogen production were therefore pioneered in areas where freshwater was abundant. Hence Norway, which had abundant freshwater, established a 135 MW Water electrolyser operating on Hydel power in 1927, at Rjukan. It produced 30000 Nm3/h of Hydrogen and was operational till the 1970s. A similar 135 MW installation was in operation at Glom fjord, Norway, from 1953 to 1991 [4]. Since then, however, Hydel power went out of fashion due to ecological concerns about big dams. Currently Steam reforming of Natural gas is the dominant Hydrogen production technology displacing electrolysis. In recent times, global warming concerns have brought back Water electrolysis into consideration, though project economics are hampered by the high costs of electrical power and of electrolysers.

2.1 Electrolyser Working principle

Water is a stable compound and energy must be externally supplied to break intramolecular bonds. Figure 2 is a representation of the ‘energy hill’ that separates molecular Hydrogen (H2) and Oxygen (O2) from their reaction product, Water (H2O). This indicates that energy needs to be supplied to split Water and form molecular H2 and O2. Energy in the form of direct current electric supply at high voltage is used to split Water into Hydrogen and Oxygen. In an electrolysis cell, the electrodes which carry electricity also function as catalysts, The presence of a catalyst facilitates the reaction by reducing the energy requirement.

Electrolyser Working principle

2.2 Construction

The components of a Water electrolysis cell are illustrated in Figure 3 and described below:

Containment Shell: All the working components of an electrolyser are held within pressure retaining containment shell. The shell is designed to withstand maximum operating pressures and temperatures. It also provides impact protection during transportation and operation.

Electrodes: These constitute the  interface through which electrons from the external current source enter and leave the Water. The positive terminal, called the Anode, receives negatively charged ions from the Water and strips out their electrons. The Cathode is the negative terminal, which receives electrons from the external circuit and pumps them into the Water.

Electrolyte: Alkaline or acidic Water is the electrolyte as well as the raw material. An electrolyte is a material that allows ions (such as H+ an OH-) to flow but not electrons. The addition of acid or alkali into Water increases the number of ionic charge carriers. Hydrogen ions are converted to Hydrogen molecules by the addition of 2 electrons to 2 Hydrogen ions in solutions. The ion-traffic therefore influences the production rate.

Separator: Electrical short-circuiting between the Anode and Cathode is prevented by the separator. This is designed to permit ion movements, while preventing physical contact between electrodes.

DC power supply: To sustain the movement of electrons and ions for continuous Hydrogen and Oxygen production, the minimum theoretical voltage under standard conditions is 1.23 V. In practical applications, various electrical resistances at electrode interface and electrolyte necessitate a higher applied voltage, ranging around 1.8 V-2.0 V.

Electrolyser Working principle2.jpg

Electrolyser and Balance of Plant.jpeg

An electrolyser cell system typically includes several individual cells arranged in one or more stacks with reactant Water flowing through the cells via input and output conduits formed within the stack structure. Apart from the Stack, the overall system requires many other equipment, termed Balance of System (BOS) or Balance of Plant (BOP). The building blocks of an electrolyser installation are shown in Figure 4.

2.3 Types of Electrolysers

At this point in time, only two types of Electrolysers are being utilised for the majority of  industrial scale projects. They are Proton Exchange Membrane (also called Polymer Electrolyte Membrane), abbreviated as PEM and Alkaline Water Electrolyser abbreviated as AWE. Two more promising technologies on threshold of active commercialisation are Solid Oxide Electrolysis (SOEC) and Anion Exchange membrane (AEM). A description of each of these is provided in the following paragraphs.

2.3.1. Alkaline Water Electrolysis

Another heading four

Hydrogen production by alkaline water electrolysis was first introduced by Troostwijk and Diemann in 1789 [3], so it is by now a well-established technology. Figure 5 is sketch of an Alkaline Water Electrolyser (AWE).

These electrolysers use an alkaline solution, comprising 20%-30% solution of Potassium Hydroxide in pure Water as the electrolyte. So essentially, the electrolyte solution is a sea of H+ and OH- ions, that participate in the charge transfer process. The Anode and Cathode are kept apart by a porous diaphragm, across which the transport of electrical charge happens via OH- ions migrating towards the Anode.

Alkaline Water Electrolyser

Electrons from the external DC circuit enter the cell at the Cathode, where two molecules of Water are reduced to one molecule of Hydrogen (H2), and two Hydroxyl ions (OH-) are produced .

Cathode: 2 H2O + 2 e− → H2 + 2 OH−

The produced Hydrogen is collected from the Cathode surface and piped out, while the Hydroxyl ions transfer through the porous diaphragm to the Anode, driven by the difference in voltage between the electrodes. At the Anode,  two Water molecules are oxidized, forming one diatomic oxygen (O2) molecule and four Hydrogen atoms.

Anode: 2 OH− → H2O + 1/2 O2 + 2 e−

Hence the Overall electrochemical equation, by  adding both half-equations is:

H2O → H2 + 1/ 2 O2

Alkaline Water Electrolysers can be  configured as unipolar or bipolar (filter press) designs. In the unipolar design, the electrodes are submerged in the alkaline electrolyte, inside a tank. The electrolyte is a 20%-30% solution of Potassium Hydroxide in pure Water. Each cell is connected in parallel. Figure 6 illustrates these two configurations.

AWE electrodes are made of Nickel. In the earliest designs, Asbestos was used as the diaphragm material, but modern designs use advanced composite materials like ZIRFON Perl diaphragm (Zirconium Dioxide and hydrophilic polymer, developed by Agfa Europe).

Unipolar and Bipolar Awe Configurations

2.3.2  Proton-Exchange Membrane Electrolysis

This type is also known as a Polymer Electrolyte Membrane Electrolysers. This is because it uses solid specialty plastic material as electrolyte instead of an alkaline (KOH) electrolyte.

The first PEM Electrolyser was conceptualized by Grubb in the early 1950s, and later developed by General Electric Co in 1966, who leveraged the invention of perfluorinated ion-exchange membranes Nafion TM by DuPont.

The  name Proton Exchange Membrane is attributed to the fact that Protons (H+) are the charge carriers. These Protons are produced by the electrolysis of Water at the Anode and migrate across the membrane electrolyte, to the Cathode:

   Anode:  2H2O → 4H+ + 4e- + O2

At the Cathode the protons combine with Electrons that are pushed in by the DC electric source, to form Hydrogen gas:

Cathode: 4 H+ + 4 e- → 2 H2

PEM Electrolyser

The main barrier for the mass production of PEM electrolysers is the high cost of the materials needed. Expensive materials like Platinum, Palladium, Iridium and Rhodium are needed for the catalyst, due to the corrosive nature of the Electrolyte. Further, Deionized Water with a high degree of purity is needed to avoid damage to the electrodes. The membrane and noble metals for the electrocatalyst, make the PEM electrolyser more expensive than other kinds. Further, PEM electrolysers will experience some degradation in performance. An increase in the voltage is expected because of equilibration of water content in the membrane and oxidation of catalyst and other metallic components. There are also potential safety issues with PEM electrolysers operating under intermittent power conditions. As Hydrogen and Oxygen production is proportional to the current density, at very low loads, the production of the gases may be lower than the permeation rate through the electrolyte, mixing with each other and thus generating dangerous combustible conditions inside the electrolyser. Another problem is related to the operating temperature of the electrolyser. It takes some time for the electrolyser to reach its nominal temperature, so intermittent operation could keep the electrolyser from reaching this temperature and working at its highest efficiency.

2.3.3. Solid Oxide Electrolysis

Donitz and Erdle were the first to develop Solid Oxide Electrolysis (SOEL), in the 1980s. The unique feature of this method is that it uses Water in the form of Steam and operates at high temperatures and pressures. This opens up many potential applications where energy in waste heat can be recovered and stored in the form of Hydrogen. The process is also more efficient than either AWE or PEM.

SOEL’s operating principle is very similar to AWE. However , the charge carriers in this case are  Oxygen ions. The corresponding half reaction equations are:

Cathode: H2O + 2 e− → H2 + O 2−

Anode: O2− → 1 /2 O2 + 2 e−

Using Steam instead of liquid Water enables comparatively higher energy efficiency, since most of  the energy needed for the electrolysis process is added as enthalpy of Steam. In addition, the high temperature accelerates the reaction kinetics, reducing the energy loss due to electrode polarization, thus increasing the overall system efficiency. The high temperature system employs Oxygen ion conducting ceramics as the electrolyte (ZrO2 stabilised by Y2O3, MgO or CaO). The fluid to be dissociated is 200oC Steam which after being further heated to 800-1000oC enters on the Cathode side. After the Steam is split to Hydrogen gas and O2- ions at the Cathode, the Oxygen ions are transported through the ceramic material to the Anode, where they discharge and form Oxygen gas. Despite this high efficiency with respect to electricity, the high temperature system still produces Hydrogen at about four times the cost of conventional Natural Gas based Steam Reformer Hydrogen.

2.3.4 Anion Exchange Membrane Water Electrolysers

Anion exchange membrane water electrolysis (AEMWE) is a potentially low-cost and sustainable technology for Hydrogen production that combines the advantages of a solid electrolyte as in PEM water electrolysis and the cost effective electrode materials used in AWE systems.

In the AEMWE, the charge carriers are Hydroxide ions (OH-) which migrate through a dense polymeric Anion Exchange membrane (AEM).The Anion Exchange membrane is a semipermeable membrane. It allows Anions to permeate, while Oxygen or Hydrogen are blocked. This exchange process can produce high purity Hydrogen and reduces the risk of  Hydrogen crossover. The electrochemical reactions occurring within an AEMWE are the same as those occurring inside an AWE.

The membrane technology is evolving. In recent years, different polymeric backbones like polysulfone, polystyrene, poly(phenylene oxide) have been studied for AEM preparation. The electrode catalysts are coated onto these membranes to for bipolar Membrane  Electrode Assemblies (MEA).

2.3.5 Technology Readiness Level

According to an IEA analysis [1], AWE and PEM electrolysers are considered to be at the same technology readiness level (TRL9) for the purpose of Hydrogen production projects. Of course, Alkaline Electrolysers have been around in the Chlor-Alkali industry for several decades. Considering the projects under development, currently AWE is dominating the commercial space.

SOEC electrolysis is at demonstration stage, with a 2.6 MW SOEC electrolyser expected to become operational at a Neste Refinery in the Netherlands at the end of 2022. Anion Exchange Membrane (AEM) electrolysers were considered by IEA  to be at TRL6 (full prototype at scale). Figure 8 maps out the current technology readiness levels of all the four technologies.

Electrolyser Technology Readiness Level

3 Technology Evaluation Criteria

Though currently only Alkaline and PEMC types of Electrolysers are being commercially deployed, there are numerous new technologies that are expected in the Green Hydrogen marketplace in the near future. When multiple technologies have to be compared, it is necessary to have common evaluation criteria that can be applied to all current and emerging technologies. This is quite complex, since Green Hydrogen projects target diverse markets. Some of the emerging applications are in industrial heating, domestic heating, road transportation, rail transportations, Green Ammonia, and many other niche applications in chemical and metallurgical industries.

Regardless of the technology, there are common aspects that need consideration in all cases. Based on field experience with Green Hydrogen projects, the key factors that need consideration for electrolyser technology selection are listed below:

Key Factors for Electrolyser Technology Selection:

Why are these technology evaluation criteria considered important? The significance of each criterion is discussed more detail in the following sections:

3.1 Availability and Stability of Renewable Power

Renewable energy for electrolysis may be sourced from Wind, Solar PV, Geothermal or Hydel sources or a combination of these. The type and quality of renewable electricity influences electrolysis technology selection, in cases where there is no other source of power supply. Hydel or geothermal energy are not widespread, and  inherently suited only for vary large scale electrolyser projects. The majority of projects reported to be under implementation or planned in the near future are in the small to medium range and utilise Wind turbines and Solar PV as green electricity sources.

Both solar and wind are characterised by variable intensity and intermittency and cannot supply continuous supply on their own to electrolysers. Due to fluctuations, the electrolyser efficiency is affected. Prolonged cycling also leads to permanent degradation of the electrolyser components. Different types of electrolysers vary in their ability to withstand these variations and in their speed of response to fluctuations. For example, PEM electrolysers are faster in their response to changes in power supply than AWE electrolysers, but more vulnerable to damage due to fluctuations. This is therefore an important criterion to be considered in technology evaluation.

Current projects in some countries have been able to mitigate this problem by permitting electrolysers to draw power from the existing power grids. To obtain Green certification, it is necessary to have a power purchase agreement with a green electricity supplier who will supply the equivalent amount of green electricity into the grid. This basically transfers the electrolyser project’s problem to the grid managers and is an administrative rather than  technical solution to the problem of renewable energy instability. Not all countries have grids that are robust enough to handle this kind of an arrangement.

Further, Electrolysers that draw their power supply entirely from Wind or Solar PV must be adequately oversized to meet their daily Hydrogen production targets within the energy availability window of a few hours. Hydrogen is stored and supplied to consumers throughput the day. Green Hydrogen Projects therefore require additional capital investment when compared to grid operated electrolysers of the same capacity.

3.2 Operating Pressure

Commercially available electrolysers generally operate from near atmospheric pressure to about 30 barg. From an electrochemical perspective, there is no barrier to developing pressure within the electrolyser since the reaction rate is not influenced by pressure. However, possibility of Hydrogen crossover from the Hydrogen sections to the Oxygen sections poses a safety hazard at higher pressures, necessitating design modifications. Additionally, high pressure operation requires heavier mechanical design, thicker diaphragms/membranes, and special design of  polymeric and elastomeric components such as gaskets that can degrade at higher Hydrogen pressures. Hydrogen embrittlement of Steel is another concern at higher pressures.

Low pressure electrolysers obviously cost less than high pressure electrolysers of the same size. However, they are not the most cost effective for emerging business segments such as Green Ammonia and Hydrogen fuelled vehicles. Figure 9 illustrates the pressure ranges required for various commercial application of Green Hydrogen.

Electrolyser Applications and Pressure Levels

For vehicle refuelling applications, it has been estimated that if electrolyser capital cost is about USD 900 per KW, then Hydrogen  compressor capital cost is around USD 3800 per KW. There will be additional operating cost for the Hydrogen compressor and associated cooling systems as well. It is clear that for all the high pressure applications, the  compression of Hydrogen will be a significant element of capital and operating costs. From this perspective, high pressure electrolysis, in which the pressure is allowed to rise within the electrolyser will reduce Hydrogen compression requirements. Designs for high pressure electrolysis are rapidly approaching commercial maturity for both Alkaline and PEMC electrolysers. Figure 10 summarizes the work done by Avalence LLC on Alkaline electrolysers working upto 6500 psig [7].

High Pressure Alkaline

High Pressure Alkaline2

PEM Electrolysers are also being developed to operate at High pressure. However, no major large-scale manufacturer has  commercially  launched  high pressure PEM electrolysers. Some of the issues being faced with high pressure PEM electrolysers are summarized below:

Mechanical Integrity/ Membrane creep

Durability

Efficiency

Apart from issues with the electrolyser cells at high pressures, there are challenges to be overcome in the balance of plant components. These include design of Hydrogen driers, gas-liquid separators, polymeric and elastomeric components, and overall safety.

3.3 Operating Temperature

Temperature influences the rate of electrochemical reactions as well as the electrical resistance, For an electrolyser, higher temperature leads to higher  efficiency. As can be seen from Figure 11. The disadvantage of higher temperature is that it adversely impacts the  longevity of an electrolyser. At higher operating temperatures, the service life is reduced. The objective therefore is to obtain a balance between high efficiency and service life. Both AWE and PEM electrolysers are operated in the 40oC to 90oC range. In contrast, SOECs work in the 650 oC to 1000 oC range. Temperature control is crucial. As cell electrical resistivity increases, higher cell voltage is needed which increases the heat production. The stack cooling systems must be evaluated for their capability to handle the maximum cooling loads during the electrolyser life.

Efficiency vs Current Density

3.4 Current Density

Current density is directly proportional to the rate of Hydrogen generation. This is because higher current density implies more electrons participating in the electrochemical reaction. The area of electrodes in contact with electrolyte and reactants determines the current density.

Interestingly, the current versus voltage characteristic is such that higher current density also means a higher voltage drop, reducing the electrolyser Voltage efficiency. Low current density will result in a lesser rate of production of Hydrogen, unless the electrode contact surface area is increased, which means higher costs. However, the electrolyser voltage efficiency will be higher. So, there is a trade-off to be considered for the same production rate, between, higher CAPEX/higher efficiency at lower current density versus higher OPEX/lower efficiency at higher current density. PEM electrolysers operate at current densities of 0.6 to 2 Amps/cm2 which is higher than corresponding AWE current densities of 0.2 to 0.4 Amps/cm2, within the same voltage range. SOECs have been observed to give higher current densities at lower voltage ranges, so as the technology matures, this will be a clear area of advantage for SOECs.

3.5 Voltage

The thermodynamically ideal reversible cell voltage that must be applied, as a minimum, to split water into its components of H2 and O2 is 1.23 V. It is computed from the Nernst equation, which relates voltage to temperature, and partial pressures of all reactants and products.

However, in reality, certain irreversible losses will occur due to various reasons including activation energy losses and ohmic losses. A voltage known as Thermoneutral Voltage equal to 1.48 V, is considered to be the voltage at which a real electrolysis cell would function at 100% efficiency. Voltage efficiency is the ratio of the thermoneutral voltage to the actual voltage required by the cell. The electrolyser produces heat at potentials above 1.48 V and absorbs heat in at potentials below this value, at constant cell temperature. The distance between the two electrodes affects the voltage drop. If the electrode are brought closer as in bipolar filter press arrangements, the charge carriers have to traverse less distance between the Anode and the Cathode. However, bringing the oppositely charge electrodes closer also increases the risk of short circuit and mixing of gases. Since AWEs use porous diaphragms to separate electrodes , the spacing if electrodes in usually more than in PEM electrolysers, making AWE cells larger. Both AWE and PEM cells generally operate in the 1.8 V to 2.2 V range.

3.6 Specific energy consumption

The  electricity consumed (kwh ) by an electrolyser stack to produce one kg of Hydrogen is called specific energy consumption. It is expressed  kwh/kg H2. This is the most widely used parameter in comparing electrolyser technologies. The specific energy consumption for AWEs is about 55 kwh/kg H2 and for PEM electrolyser it is about 60 kwh/kg H2. Note that since the density of Hydrogen is 0.0899 Kg/Sm3 (at Standard temperature and pressure), the energy consumption per unit volume of Hydrogen is 4.94 kwh/Sm3 H2 for AWE and 5.39 kwh /Sm3 H2 for PEM electrolysers.

3.7 Efficiency

The efficiency of the electrolysis systems is crucial for cost effective production of electrolytic Hydrogen. This is because operating costs of electrolysers are dominated by power costs. Completive costs can be achieved only by increasing overall efficiencies.

Electrolyser energy efficiency can be defined as the energy in the Hydrogen produced, divided by the energy used to produce it. The input and output energies are usually expressed in terms of heating value (HHV) which facilitates comparison with fossil fuel based Hydrogen production.

The overall efficiency of the electrolyser installation is the combined effect of:

The boundaries for energy efficiency calculation will depend upon which type of efficiency is being calculated. Hence based on the scope, losses may be included from AC/DC conversion and transformer losses, energy used for BOP items such as water treatment, cooling systems, buildings and auxiliary packages, compression and Hydrogen purification.

Example: The HHV of hydrogen is 142 MJ/kg, which is equal to 39.4 kWh/kg. So, an electrolyser that consumes 50 kWh of electricity to produce one kilogram of Hydrogen has an efficiency of 39.4 kWh/kg divided by 50 kWh/kg, which is 79%.

As discussed earlier, a electrolyser can be operated very efficiently, if the current density is kept low. From an energy efficient  design perspective, the biggest overall efficiency gains can usually be achieved by optimizing the design of the Balance of Plant components.

3.8 Start-up time

Due to the intermittent nature of renewable energy supplies to a green Hydrogen electrolysis plant, the electrolyser technology must permit rapid start upon from cold conditions. Even in the case of Grid supply, there are different consumers connect to the grid, so fast response Hydrogen electrolysers are seen as a load balancing element in the grid. PEM electrolysers  are typically faster to start-up than Alkaline electrolysers. However constant cycling leads to faster performance degradation of PEM electrolysers than in the case of AWEs.

3.9 Electrodes

Due to the corrosivity of Polymer electrolytes used in PEM electrolysers, the electrodes are made from very costly materials such as like Platinum, Palladium, Iridium and Rhodium. In contrast AWEs can use low cost materials like Nickel for electrodes. Capital investment is usually the deciding factor for any project and electrodes in hundreds of cells in a typical installation, will need to be replaced after some time due to degradation. Hence, life cycle costs of electrodes are an important criterion for technology evaluation.

3.10 Membrane or Diaphragm

In the case of membrane based electrolysers such as PEM and AEM, the quality assurance of membranes is a major concern. This must be addressed with the manufacturers during the technology evaluation process. The membrane is part of a composite assembly known as the Membrane Electrode Assembly (MEA). There is a significant possibility of it getting  damaged during the manufacturing process.

Smaller manufacturers tend to use manual processes where quality control is challenging. In a large scale electrolyser installation, the will be hundreds of cells and even a few damaged membranes can cause Hydrogen purity to drop as well as create safety problems due to Hydrogen crossover. Even with the best quality control and ensuring optimum operating conditions, degradation of membranes is inevitable.

In the case of AWE electrolysers, the Diaphragm can develop mechanical damage or corrode and pores can get blocked.

3.11 Dimensions and weight of stack

There are many potential applications such as Hydrogen production in vehicle Hydrogen  fuel stations and for decentralized or portable Hydrogen supplies, where Electrolyser footprint is an important consideration. In such cases, PEM is preferred over AWE electrolysers, which are inherently larger and heavier. In large industrial settings however, currently, AWEs are dominating the market, since they are proven at scale and equipment weight, or footprint is not a major issue.

3.12 Replacement Interval

Literature on the subject, as well as vendor feedback indicates that key components of electrolysers have to be replaced, since performance and material degradation is inevitable even under ideal operating conditions. Generally, under ideal operating conditions, the replacement interval for AWEs is 75000 hours and for PEM electrolysers is 60000 hours. When there is significant cycling in power supply as in the case of renewable power and if water quality is poor, the lifetime will be reduced. Replacement costs must be included in the project cost estimate at the feasibility stage. Performing replacement for hundreds of cells in a large scale installation is a tedious operation. Considering the rapid progress in electrolyser technology, it may be worth looking at scrapping the plant and opting for newer technologies in lieu of component replacement.

3.13 Catalyst Poisoning

The catalyst on the electrodes is crucial to effective electrolysis since it reduces the activation energy and makes the reaction possible. Water quality and KOH quality are the two factors that need to be monitored since these are the routes through which contaminants can enter. Corrosion products within the cell can also cause poisoning. In some cases, there may be side reactions caused by impurities which can poison the catalyst. Hence careful attention must be given to design and operation of the Balance of Plant units, especially Water treatment plant and to ensure that corrosion resistant materials are used in the equipment and piping.

3.14 Technology Maturity Level

As discussed in an earlier section (see Figure 8), currently AWEs are dominating the market due to the fact that industry has over a hundred years of experience in this technology in the Chlor-Alkali sector. Specifically for Hydrogen production, however, IEA considers both PERM and AWE technologies to be at the same technology readiness level of TRL9 [1]. SOEC is not far behind and may eventually be the favoured technology for some industrial applications in future.

4 References

  1. Electrolysers – Analysis – IEA (tracking report, September 2022)
  2. History of water electrolysis – Big Chemical Encyclopedia (chempedia.info)
  3. A review on water electrolysis, by Emmanuel Zoulias et al., report under the contract number ENK-CT-2001-00536 (RES2H2).
  4. NEL Hydrogen brochure.
  5. Recent Developments on Hydrogen Production Technologies: State-of-the-Art Review with a Focus on Green-Electrolysis, by Leonardo Vidas and Rui Castro, Appl. Sci. 2021, 11, 11363. https://doi.org/10.3390/app112311363.
  6. The case for high-pressure PEM water electrolysis by Ragnhild Hancke , Thomas Holm , Øystein Ulleberg in Energy Conversion and Management 261 (2022) 115642.
  7. High-Capacity, High Pressure Electrolysis System with Renewable Power Sources Paul Dunn and Dave Mauterer, Avalence LLC DOE Merit Review, 11 May 2011.
  8. Hydrogen Generation From Electrolysis(Proton Energy Systems), Final Report for DOE Award DE-FC36-04GO13030,February 28, 2009.
  9. Anion exchange membrane water electrolysis using Aemion™ membranes and nickel electrodes – Journal of Materials Chemistry A (RSC Publishing).
  10. High Pressure PEM Electrolysis Status, Key Issues, and Challenges, by Monjid Hamdan, Giner, Inc. Electrolytic Hydrogen Production Workshop NREL, Golden, Colorado, February 27-28th, 2014.

1 Introduction

The combustion of fossil fuels is acknowledged as the single largest anthropogenic source of Carbon Dioxide emissions. The capture of Carbon Dioxide from Flue gases is an important part of the transition roadmap to a low Carbon, sustainable energy future.

Carbon Dioxide emissions

During the year 2021, an estimated 36.3 Gigatons (Gt) of Carbon Dioxide were emitted from fossil fuel combustion in the global energy and industrial process sectors. There is a direct correlation between GDP growth rates and Carbon Dioxide emissions from the energy and industrial sectors. This is apparent from Figure 1 which displays historical Carbon Dioxide emission trends from these sectors and shows a dip in emissions during the 2020 pandemic induced slowdown, followed by a sharp increase as GDP recovered to pre-COVID levels [1].

Globally, Carbon Dioxide constitutes more than three-fourths of all green-house gas emissions [2]. Further, a quarter of all global Carbon Dioxide emissions are from the power generation and industrial sectors [3]. These post-combustion emissions are termed Flue gas emissions, as they emanate from exhaust stacks or chimneys of equipment such as Steam Boilers, Fired-heaters, Furnaces, Gas Turbines, Gas Engines and Liquid Fuel Engines.

In fossil-fuel based power plants, Coal, Furnace Oil, Diesel, and Natural Gas provide the primary thermal energy to drive electricity generation equipment. Coal is the most widely used fuel at present, but there is global consensus on phasing it out and the transition to cleaner fuels is underway.

In the industrial sector, fossil-fuels are used to provide process heat in Chemical, Metallurgical, and Mineral transformation processes. Among manufacturing industries, the following large-scale, energy intensive processes are major emitters of Carbon Dioxide from Flue gases:

Hence these are considered priority sectors and receive global attention for technology development and deployments relating to Carbon capture, utilization, and Sequestration.

2 Mitigation Strategies for Combustion Generated Carbon Dioxide

Currently there are three technological approaches to mitigate Carbon Dioxide emissions from Flue gases [4].

In this approach Carbon Dioxide is captured from Flue gases leaving the stack. This is an end-of-pipe approach and generally does not involve changes to the existing process. However, apart from Carbon Dioxide and Water, the Flue gases contains Nitrogen and Oxygen from combustion Air, besides Oxides of Sulphur and Nitrogen and other components depending on the fuel.

This method converts fossil fuels to Syngas, with Carbon Dioxide being removed before fuel combustion. The fuel that is eventually combusted is either Hydrogen or a Hydrogen-rich mixture with Carbon Monoxide.

This involves reduction of Flue gas volume by eliminating the entry of Nitrogen via combustion Air. An Air separation plant generates pure Oxygen for fuel combustion.

Figure 2 illustrates the three approaches.

three approaches

Of the three approaches, Post-combustion capture of Carbon Dioxide is the easiest to implement on existing facilities. This is because it minimizes disruption to existing processes. Post-combustion capture projects can be executed as brownfield retrofits and scheduled to coincide with plant maintenance shutdowns.

The second approach of Pre-combustion capture avoids Flue Gas Carbon Dioxide emissions during combustion. The idea is to achieve a fuel switch from fossil fuel to Hydrogen, by removing Carbon from the fuel, via Gasification or Steam Reforming. For Carbonaceous fuels that are solid, liquid, or gaseous, partial oxidation to Syngas is possible, followed by Carbon Dioxide capture. Similarly, Steam Reforming can be used to convert liquid and gaseous Hydrocarbon fuels to Hydrogen. Obviously, significant investments are required for the Air separation or Hydrogen production plants and associated utility systems. Additional operating costs for Air separation and Hydrogen production also affect the economics. A credible business case for such investments does not exist at the present time. In future, however, increased regulatory and stakeholder pressures, Carbon reduction incentives or punitive Carbon taxes might create viable opportunities for this approach.

The third approach, namely, Oxy-combustion, also involves capture of Carbon Dioxide from Flue gases, albeit with volume reduction achieved by the prior removal of Nitrogen from combustion Air. Some modifications on the combustion systems and fired equipment may be needed in existing plants, in addition to Air separation and utilities. This approach definitely improves the overall economics of capture, though the Carbon Dioxide stream has a relatively higher concentration of impurities needing eventual removal.

The capability for brownfield retrofitting with minimal disruption has driven industry preference towards Post-combustion (i.e. Flue gas) Carbon capture options. Policy makers also see this as a potential early-win option in achieving Carbon emission reduction targets. Hence such projects generally get the benefits of policy support. Given this directional thrust, the differentiators among various post combustion capture technologies are CAPEX, OPEX, efficiency, reliability, safety, and environmental aspects. Each industrial sector and project has unique features that need consideration while selecting Flue gas Carbon Dioxide capture technologies.

3 Technologies for Flue Gas Carbon Dioxide Capture

Commercial and emerging technologies for Flue gas Carbon Dioxide removal are based on the following mass transfer modes [4]:

The main features of these technologies are described in the following sections.

3.1 Absorption in solvents

Solvent absorption is the most commonly used technology for Flue gas Carbon Dioxide capture. The concept of solvent absorption is based on the fact that some solvents have an affinity for Carbon Dioxide, either due to solubility or reactivity. These solvents have the ability to absorb Carbon Dioxide at higher pressures or at lower temperatures and release it when the pressure is reduced, or the solution is heated. Apart from satisfying absorption efficiency and energy demand criteria, solvents must withstand degradation during repeated absorption/desorption cycles and be non-hazardous.

Figure 3 illustrates the concept of solvent absorption. Cooled Flue gases, after contaminant removal, are contacted by lean solvent in a counter-current absorption column where typically 95% of the Carbon Dioxide is removed. Clean Flue gases exit from the top of the absorption column and rich solvent leaves at the bottom, en-route to the regeneration column. The regeneration process involves stripping-out absorbed Carbon Dioxide and the regenerated solvent is then cooled and recirculated to the absorber.

concept of solvent absorption

Conventionally, solvents are called physical or chemical solvents depending on whether absorption is purely based on solubility, or it involves chemical reactions. Physical absorption depends upon high partial pressure of Carbon Dioxide in the gas phase to drive the process. Flue gases on the other hand are discharged at atmospheric pressure and the partial pressure of Carbon Dioxide is relatively low. Hence the solvents used in Flue gas Carbon Dioxide removal are usually chemical solvents. There are some specialty hybrid solvents as well, which involve both physical and chemical capture mechanisms.

A wide variety of chemical solvents have been successfully used for post-combustion Carbon Dioxide capture. Most of them are formulations containing Amines. It is convenient therefore, to place commercially important solvent processes in the following categories:

3.2 Amine Solvents

Absorption by Amine solvents has been the mainstay of Carbon Dioxide separation in the Gas Processing and Chemical Process industries for several decades. These proven technologies have therefore been a “go-to” option to reduce the investment  risks associated with large scale deployment in post-combustion Carbon Dioxide capture applications.

Amines, also referred to as Alkanolamines, are a group of alkaline chemicals related to Ammonia. The replacement of one or more Hydrogen atoms in Ammonia (NH3) by an organic group results in an organic Amine.

AlkanolaminesPrimary Amines are the group of compounds where one Hydrogen atom in the Ammonia structure is substituted by one organic group, secondary Amines have two Hydrogen atoms substituted by two organic groups and tertiary Amines have all three Hydrogen molecules replaced by organic groups [5]. Figure 4 shows the molecular structures of Amines commonly used to remove acid gases like Carbon Dioxide and Hydrogen Sulphide in conventional gas sweetening processes.

Amine solvent processes for industrial post-combustion Carbon Dioxide capture applications are mostly based on Mono-Ethanol Amine (MEA). This is due to its high reactivity with Carbon Dioxide and relatively low solvent cost. It is reasonably resistant to degradation across multiple operating cycles. Technical knowhow and operating data for aqueous MEA systems are available in the public domain. The data indicates that despite its widespread use, aqueous MEA solution is not the optimum solvent for Flue gas applications. Disadvantages include high energy requirements, formation of stable Carbamates and heat stable salts, high oxidative degradation, high vaporization losses and high corrosivity at concentrations above 20%. Several improved Amine formulations that use MEA and other Amines have been developed to mitigate these issues and tackle the wide range of Flue gas Carbon Dioxide capture applications in industry.

3.2.1 Typical Amine Absorption Process

The principle underlying all Amine Absorption Technologies are similar. Conventional aqueous MEA is customarily used as a benchmark to compare various Amine solvents. MEA solution concentrations used in Flue gas Carbon Dioxide capture range from 15 % to 30% by weight of MEA in Water. MEA undergoes a reversible and exothermic reaction with Carbon Dioxide in aqueous solution.The reaction scheme is complex, since Carbon Dioxide dissolves in Water to form Carbonic Acid,  which partially ionizes to release Protons that are picked up by MEA. This step is called Protonation of Amine and it facilitates dissolved Carbon Dioxide transformation to Bicarbonate ion. This allows additional Carbon Dioxide to be absorbed. MEA also reacts directly with dissolved Carbon Dioxide to form Carbamate (RNHCOO–). During regeneration the reactions are reversed. The overall simplified scheme is as follows [8]:

Carbon Dioxide absorption: 2 R-NH2 + CO2 → R-NH3+ + R-NH-COO–

MEA Regeneration: R-NH-COO– + R-NH3+ + (Heat) → CO2 + 2 R-NH2

As can be seen, two moles of Mono-Ethanol Amine are required to remove one mole of Carbon Dioxide. This is one of the disadvantages of the conventional MEA process since it necessitates high Amine circulation rates and correspondingly high energy consumption.

Figure 5 is a typical process scheme used for the Conventional MEA Absorption process.

Hot Flue gas, after removal of impurities, and waste heat recovery, undergoes quenching in a direct-contact cooler (DCC), using a spray of deionized Water or cooled Steam condensate. Thereafter, cooled Flue gas enters the Amine absorption tower for removal of Carbon Dioxide. In the absorption tower, lean Amine solution from the regenerator flows down, establishing counter-current contact and mixing with the ascending Flue gas. The tower may be a packed or trayed column. Stainless steel materials are used due to the corrosivity of MEA and Carbonic Acid.

At any point, the difference between the partial pressure of Carbon Dioxide in the Vapor Phase and its corresponding equilibrium partial pressure establishes the driving force for mass transfer. At the top and bottom of the absorption column, Amine solvent will be at about 80% of its equilibrium concentration with Carbon Dioxide at the corresponding temperature, so that the driving force is maintained.

The path ABCD in Figure 5, shows the typical operating cycle of MEA solvent absorption and regeneration,  plotted on Carbon Dioxide-MEA equilibrium curves. At point “A”, lean MEA solvent is fed to the top of the absorber and then picks up Carbon Dioxide from Flue gas, with temperature rising due to the exothermic reaction. Rich MEA leaves the absorber at “B”, typically at 60 oC, pre-heated in the cross flow heat exchanger (XFHE) and fed to the top of the stripper at “C”. The liquid flowing down the stripper packing or trays is heated further, by hot reboiler vapour passing upwards and releases Carbon Dioxide. Typically, there will still be 0.15 – 0.35 moles of Carbon Dioxide per mole of Amine in the lean MEA leaving the stripper at the bottom, point ”D” which is at around 120 oC.

To avoid continuous build-up of heat stable salts (HSS), a slip-stream of lean Amine is routed to the reclaimer. Here, Caustic Soda is used to  neutralise heat stable salts and Water, Carbon Dioxide and Amine are evaporated, to leave all solid impurities in the reclaimer [6].

3.2.2 Commercially Important Amine Solvent Processes

The Amine based processes used in Commercial operation or near-commercial demonstration projects are as follows [6]:

These are summarized in the following sections along with example projects.

3.2.2.1 Kerr -McGee/ABB Lummus Crest Process [10]

This is the earliest commercial application of aqueous MEA to post-combustion Carbon Dioxide capture. The process uses 20% by weight aqueous MEA solution and the process scheme is as described in section 3.2.1.

As mentioned earlier MEA has rapid kinetics but requires high regeneration energy compared to the newer Amine solvents. Consequently, the effective output from a power plant could reduce by more than one-third of its capacity when integrated to a Flue gas Carbon Dioxide plant using aqueous MEA solution [9].

Example Project

The Searles Valley Minerals Plant in Trona, California, is the first commercial large-scale Flue gas Carbon Dioxide capture plant in the United States. It was set up in 1978, using the Kerr-McGee/ABB Lummus Crest Process and is still in operation. It comprises two parallel trains each capturing 363 metric tons/day of Carbon Dioxide from the flue gases emitted by a Coal-fired boiler. The Carbon Dioxide is utilized is used to carbonate Brine for Soda Ash manufacture. This aspect also makes the project an early example of CCU (Carbon Capture and Utilization). It may be noted that a typical 500 MW Coal-fired power plant, generates about 12,500 tonnes Carbon Dioxide/day.

3.2.2.2 Fluor Daniel Econamine FG plus process [11]

The “ Econamine FG plus” process has been developed by Fluor Corporation based upon the well-known Dow Amine process for Acid Gas removal. Fluor purchased the license from Dow Chemical in 1989 and subsequently  improved the technology for Flue gas Carbon Dioxide capture. Energy requirement for Solvent regeneration is a major operating cost and the Econamine technology reduces Steam consumption by over 30%, compared to the conventional MEA process. The solvent formulation enables Carbon Dioxide removal from low-pressure, Oxygen-containing streams without rapid oxidative degradation.

Fluor have been successful in licensing this technology to dozens of power and industrial projects  worldwide, ranging from Coal and Gas Turbine power plants to Steam-Methane Reformers. Each type of application has unique technical aspects that need consideration.

For example, Gas Turbine flue gases are characterised by low Carbon Dioxide concentration while Oxygen concentration is relatively high. Further, back-pressure and pressure fluctuations affect turbine performance. The solvent must resist oxidative degradation and have good Carbon Dioxide pickup at low partial pressures. Figure 6 illustrates the typical scheme of an “Econamine FG plus” unit at a Gas Turbine based power plant.

Econamine

Econamine2

A Coal-fired power plant, on the other hand, poses a different set of problems related to Flue gas Carbon Dioxide capture. Flue gases even after pollution control treatment, can contain Sulphur Dioxide, Ammonia (from De-NOx units), condensed Sulfuric acid, or Hydrochloric acid droplets, particulates, and other trace components. Acidic impurities react with Amine to form heat stable salts that build up in the system and affect performance. The “Econamine FG plus” process for Coal-based plants therefore includes pre-treatment to remove these impurities. This is illustrated in Figure 7, which is a typical  process scheme for a Coal-based power plant. Here a selective catalytic reduction system involving Ammonia injection is used to remove Oxides of Nitrogen. Other steps shown include adsorbent injection for Sulphur-Trioxide gas and even Activated Carbon injection for adsorbing Mercury. Subsequently particulates are captured by ESP or fabric filters and a wet or dry Lime based Flue gas Desulphurization unit ensures complete removal of Sulphur Oxide impurities.

Example Project

An early and successful commercial scale application of the Econamine FG plus technology  was  the unit established  for Florida Power and Lights Gas Turbine Power plant  at Bellingham, Massachusetts, USA, in 1991. The plant was designed to capture 365 short tons per day of Carbon Dioxide from the power plant Flue gases. It was operated and maintained by Fluor from 1991 to 2005.

Example Project

3.2.2.3 MHI Hindered Amine (KM-CDR™) Process

This process called the KM-CDR™ (Kansai Mitsubishi Carbon Dioxide Recovery) was developed by Mitsubishi Heavy Industries (MHI) and Kansai Electric Power Co., Inc. It uses a sterically hindered Amine solvent named KS-1™. Sterically hindered Amines have relatively bulky organic groups connected to the Amine group. They can be designed to inhibit Carbamate formation and hence ensure higher free Amine availability for Carbon Dioxide dissolution and hydrolysis, by Protonation. MHI have commercially deployed their KS-1™solvent, and further developments such as KS-2 and KS-3 have been reported. The KS-1™ solvent circulation rate  is  about 60% of that of the MEA process, which reduces pumping costs, as well as equipment sizes. Further, the heat of absorption is 20% lower than that of MEA, hence the regeneration energy requirement reduces by a corresponding amount [7].

It may be noted however, that the unit cost of the solvent is higher by a factor of about five when compared to MEA. The KS-1™solvent also requires low levels of SOx and NOx (typically 1ppm) and therefore requires upstream polishing of Flue gases to achieve these absorber input requirements [10].

Example Project

MHI’s reference list includes thirteen Carbon Dioxide capture plants to produce Fertilizer, Methanol and Enhanced Oil Recovery [12]. Their most significant project using KM-CDR™ has been the Petra Nova post-combustion Carbon capture project,  This project is located at the W.A. Parish generating station in Fort Bend County, Texas, USA. It is designed to remove more than 90% of the Carbon Dioxide from a slipstream of Flue gas of a 240 MW Coal-fired power plant boiler The facility was commissioned in December 2016, with the captured Carbon Dioxide being utilized for Enhanced Oil Recovery at the West Ranch Oilfield [13].

Petra Nova has a Carbon Dioxide capture capacity of  1.4 million metric tons of per year. Figure 9 is a simplified Process Flow scheme of the Carbon Dioxide capture unit.

MHI Process.jpeg

3.2.2.4 Carbon Clean Solution Ltd. (CCSL) Process [12]

The solvent used in the CCSL process is a mixture of hindered Amine (2-Amino-2-Methyl-1, 3-Propandiol) with the Potassium salts of Amino Carboxylic or Sulfonic  acids and about 75 weight % of Water. This mixture is termed Amine Promoted Buffer Salt (ABPS). The Process is called CDRMax™, The CDRMax™ process improves upon the following aspects of the conventional MEA process:

Example Project

CCSL’s first commercial project with a Carbon Dioxide capture capacity of 60,000 metric tons per year was commissioned in India in 2016, at Tuticorin Alkali Chemicals and Fertilizers. The recovered Carbon Dioxide from a Coal-fired boiler is used to make Soda Ash.

3.2.2.5 Shell Cansolv Process [10]

Cansolv used to be a subsidiary of Union Carbide and was purchased by Shell Global Solutions International B.V. The Cansolv process uses an aqueous Diamine Solvent that can be tailormade to selectively remove Carbon Dioxide, Sulphur Dioxide and Oxides of Nitrogen. This makes it suitable to treat Coal-based power plant Flue gases. For example, Cansolv DC103 captures Carbon Dioxide whereas Cansolv DS removes Sulphur Dioxide. Thus, by using the two solvents sequentially, both Sulphur Dioxide and Carbon Dioxide can be removed (note: Oxides of Nitrogen are more easily removed by Selective Catalytic Reduction). The Cansolv DS Sulphur Dioxide capture system produces Sulphuric Acid as a byproduct. Heat integration in the design ensures that heat of absorption in the Sulphuric Acid unit can be harnessed to provide thermal energy elsewhere in the process.

Example project

The Cansolv process incorporating Sulphur Dioxide and Carbon Dioxide capture was implemented at SaskPower’s Boundary Dam Coal-fired power plant located in Estevan, Saskatchewan, Canada. The project was commissioned in 2014. The Carbon Dioxide capture unit was retrofitted to a 150 MW Coal-fired power unit in the complex. The process used Cansolv DS to achieve 100% Sulphur Dioxide capture before routing the Flue gases to a Cansolv DC103 Carbon Dioxide capture system. After retrofitting, the 150 MW unit could produce 115 MW net power for sale. The Steam turbine and generator were replaced in the retrofit. The Carbon capture capacity of  the Cansolv plant is one million tonnes per annum of Carbon Dioxide, which is sent for sequestration. This is in fact the first Carbon Capture and Sequestration project to have been implemented on a Coal-fired Power plant [10,14].

3.2.2.6 TCM’s CESAR1 Solvent

The CESAR1 solvent is at an advanced testing stage, operating at near-commercial scale. It has been developed at the Technology Centre Mongstad (TCM DA), located next to Equinor refinery in Norway. TCM is a joint venture between Gassnova, Equinor, Shell and Total Energies.

Due to its proximity to the refinery, the solvent has been tested on Flue gases from the refinery’s Combined Cycle Gas Turbine power plant (CCGT) and Residue Fluid Cracker Unit (RFCCU), as well as other refinery units such as Steam Methane Reformer (SMR). The CESAR1 solvent is a blend of 27 wt.% 2-Amino-2- methylpropanol (AMP) and 13 wt.% piperazine (PZ) and is considered to be a better solvent than MEA in terms of thermal energy and stability [17].

TCM CESAR1 plant

Figure 10 is simplified process flow diagram of the TCM CESAR1 plant. Flue gas from the blower is cooled to the required temperature (normally 20-50°C) in the Direct Contact Cooler (DCC). The lean Amine solvent can be fed either at 12m, 18m or 24m to the packed bed absorber (highlighted in yellow in Figure 10). Rich Amine from the absorber is pumped through the rich/lean cross plate heat exchanger to the top of CHP stripper. A slip-stream of the cold rich Amine is bypassed upstream the heat exchanger to the stripper overhead.

Example project

TCM has conducted several test campaigns using CCGT and RFCCU flue gases. The main objective of these campaigns has been to benchmark the performance of the CESAR1 solvent in terms of energy demand, emissions and solvent consumption. The CCGT tests have captured 80 metric tons/day of Carbon Dioxide while the RFCCU gases capture rate has been 200 metric tons/day. There are many operational challenges that need to be overcome before commercialization. It has been verified that the energy demand is lower by around 10% compared to 30 wt.% MEA.

3.3 Non-Amine Solvents

In contrast to the variety of Amine-based Flue gas Carbon Dioxide capture technologies, there is only one  non-Amine option of commercial significance at this time. This is Alstom’s Chilled Ammonia Process. Other non-Amine Solvents do exist in the Gas Treatment industry but have not found favour for Flue gas Carbon Dioxide capture applications. Newer options such as ionic liquids are at development stage.

3.3.1 Alstom Chilled Ammonia Process

Alstom’s patented  Chilled Ammonia Process (ACAP) addresses  the problems faced by Amine Solvents such as oxidative degradation, formation of heat stable salts, reactions with Oxides of Sulphur and Nitrogen and evaporative losses. The ACAP process uses the chemical equilibrium characteristics of a mixed Carbon Dioxide, Water, Ammonia, Ammonium Carbonate, and Ammonium Bicarbonate solution at various temperatures, to absorb and release Carbon Dioxide. It also allows the solvent regeneration to be performed at higher temperature than allowed for MEA. This means that the regenerator can operate at a higher pressure  and Carbon Dioxide can be released at higher pressure to downstream processes for utilization or sequestration. The  ACAP Process requires a larger absorber than in the case of MEA, because it has a relatively low reaction rate and Carbon Dioxide loading, and loses some efficiency to the Chiller, which is required to maintain reaction temperature. There are also scaling issues that have been reported. Figure 11 illustrates the process scheme of the ACAP Process.

Alstom Chilled Ammonia Process

The ACAP scheme involves two-stage cooling and chilling of Flue gases to about 35 0F (1.7 0C), by direct contact with refrigerated Water. Condensed Water drops out of the chilled Flue gas. The cooling circuit consumes about 1% to 2% of the power plant’s power output, but significantly reduces the compression power requirements thereafter. Subsequently, Carbon Dioxide is removed in the absorber by contacting with lean solvent. The rich solvent containing absorbed Carbon Dioxide is then pumped for regeneration at elevated pressure and temperature [10,15].

Example project [16]

In 2009, Alstom Power commissioned  a chilled-Ammonia CCS technology validation project at American Electric Powers Mountaineer Plant in New Haven, WV, USA. AEP’s Mountaineer plant is a 1,300-megawatt electrical (MWe) coal-fired unit that was retrofitted in 2009 with Alstom’s patented chilled ammonia CO2 capture technology on a 20 MWe portion, or slipstream, of the plant’s exhaust Flue gas. The Flue gas is taken downstream of the plant’s existing Selective Catalytic Reduction (SCR), particulate control, and wet Flue gas desulfurization (WFGD) systems. The slipstream of Flue gas is chilled and contacted with a solution of Ammonium Carbonate, which absorbs the Carbon Dioxide to create Ammonium Bicarbonate. The Ammonium Bicarbonate solution is then regenerated by heating under pressure to produce a high-purity stream of Carbon Dioxide. The Carbon Dioxide is sent for sequestration.

3.4 Limitations of Solvent Absorption Technologies

Solvent Absorption processes for  post-combustion capture of Carbon Dioxide have to handle large volumes of hot, contaminated, low-pressure Flue gases. This inevitably leads to the following disadvantages:

3.5 Adsorption onto Solid Surfaces

Adsorption processes using solid regenerable sorbents capable of capturing Carbon Dioxide from Flue gas streams can potentially overcome many of the disadvantages of Solvent processes. These include reduced energy for regeneration, greater Carbon Dioxide removal capacity, selectivity, and ease of handling. Potential disadvantages for adsorbents include particle attrition, handling of large inventories of adsorbents and thermal management of  adsorber vessels [10].

3.5.1 Types of Adsorption Processes

Adsorption processed are grouped into physical adsorption, due to  weak Van der Waals forces or chemisorption ,where stronger covalent bonds are established between Carbon Dioxide molecules and binding sites on the adsorbent surface. Both physical and chemical adsorbents are used for Flue gas Carbon Dioxide capture. Suitable adsorbents must have selectivity for Carbon Dioxide, sufficient adsorption capacity, enable adequate kinetics of adsorption mechanical strength to withstand pressure and temperature cycling. Adsorption systems may use packed-bed or fluidized-bed configurations [10].

Figure 12 illustrates the principles of adsorption processes for Flue gas Carbon Dioxide capture.

Adsorption process

Adsorption processes have not yet been deployed at commercial scale. Various adsorbent materials that are being researched include  Zeolite 13X, Metal Organic Framework (MOF), Activated Carbon, supported Alkali Metal Carbonates, Metal Oxides and Alkali Metal salts.

3.6 Cryogenic Separation [5]

Cryogenic separation of Carbon Dioxide from Flue gases is at early research and development stage. This technology is more likely to be applied for pre-combustion capture of Carbon Dioxide from Fuel gas. This is because a lot of experience has been gained with low temperature separation of Carbon Dioxide from Natural Gas and Syngas in the Hydrocarbon Industry.

The underlying principle is to separate Carbon Dioxide as liquid at  high pressures or as solid by freezing. The cooling can be accomplished by Joule Thomson expansion of the process gas or by external refrigeration, and the liquid temperature is typically below -60 0C.When cooled Below -78 0C Carbon Dioxide will freeze.

At least two cryogenic technologies have been publicly demonstrated  at near-commercial scale for Natural gas applications, as follows:

3.6 Membrane Separation[19]

Membranes are currently used commercially for Carbon Dioxide removal from Natural Gas at high pressures. However, there is only one technology that is currently available at pre-commercial stage, for Flue gas Carbon Dioxide capture. This is the process developed by Membrane Technology and Research, Inc., (MTR) USA. Their membrane-based post-combustion Carbon Dioxide capture technology uses a new class of membranes, called Polaris™, that has ten times the Carbon Dioxide permeance of conventional gas separation membranes. A tenfold increase in permeation rates leads to correspondingly smaller membrane units, decreasing the CAPEX.

Example project

MTR has operated a small pilot system using the Polaris™ membrane system in slipstream tests at the National Carbon Capture Centre (NCCC). The system  captured 20 metric tons per day of carbon Dioxide .Now it is proposed to install a large pilot to  achieve about 70% Carbon Dioxide capture from a 10 megawatt electricity (MWe) equivalent slipstream of Flue gas. This works out to 140 metric tonnes per day of Carbon Dioxide. The proposed process scheme and skid layout are shown in Figure 13.

MTR Process

MTR Process Description for Large Pilot

Flue gas to the unit will be at 85°C, having about 12.7% Carbon Dioxide and 18% Water. A blower boosts the Flue gas pressure to about 1.2 barA. Thereafter, the Flue gas is quenched in a Direct Contact Cooler (DCC), which reduces the Water content of the gas to 1.5% and increases the Carbon Dioxide content to about 15%. The gas subsequently enters the first-stage membrane modules, where it splits into a Carbon Dioxide enriched permeate (about 50% Carbon Dioxide) and a vent gas (about 4% Carbon dioxide), which is routed to the vent stack. A vacuum pump maintains about 0.1 barA pressure on the permeate-side of the membrane and ensures sufficient permeate flow rate. The vacuum pump discharges at about 1.1 barA, with the first stage permeate going to a second-stage membrane, which further enriches the gas to about 85% Carbon Dioxide. The second-stage membrane unit also uses a vacuum pump on the permeate side. The permeate gas from the second membrane stage is further boosted to 25 barA by a compressor. Some dehydration occurs due to compression and cooling to about 5 0C. A Molecular Sieve drier  then produces dry Carbon Dioxide gas. The dry gas is further subjected to cryogenic distillation to get high purity liquid Carbon Dioxide.

4 Conclusion

The following aspects of Flue gas Carbon Dioxide capture technologies are apparent from this review:

5 References

  1. Global Energy Review: CO2 emissions in 2021; Flagship Report, March 2022, IEA; https://www.iea.org/reports/global-energy-review-co2-emissions-in-2021-2
  2. Global Greenhouse Gas Emissions Data: United States EPA; https://www.epa.gov/ghgemissions/global-greenhouse-gas-emissions-data
  3. “CO₂ and Greenhouse Gas Emissions”; by Hannah Ritchie, Max Roser and Pablo Rosado (2020) – Published online at OurWorldInData.org. https://ourworldindata.org/co2-and-other-greenhouse-gas-emissions
  4. Report of the Mission Innovation Carbon Capture, Utilization and Storage Experts’ Workshop Hilton Hotel North, Houston Texas September 25–29, 2017. https://www.energy.gov/fe/downloads/accelerating-breakthrough-innovation-carbon-capture-utilization-and-storage
  5. Assessing the Cost Reduction Potential and Competitiveness of Novel (Next Generation) UK Carbon Capture Technology Literature Review, Document Number: 13333-8820-RP-003 Date: 21st February 2018 Revision: 2A
  6. BAT Review for New-Build and Retrofit Post-Combustion Carbon Dioxide Capture Using Amine-Based Technologies for Power and CHP Plants Fuelled by Gas and Biomass as an Emerging Technology under the IED for the UK, UKCCSRC Report, Ver.1.0, July 2021. By Gibbins, J., Lucquiaud, M. (2021).
  7. Flue gas treatment for CO2 capture; by Deborah Adams IEA Clean Coal Centre, June 2010.
  8. IECM Technical Documentation: Amine-based Post-Combustion CO2 Capture; https://www.uwyo.edu/iecm/
  9. Current status and future development of solvent-based carbon capture; by Eni Oko, Meihong Wang & Atuman S. Joel; Int J Coal Sci Technol (2017) 4(1):5–14. https://link.springer.com/article/10.1007/s40789-017-0159-0
  10. Post Combustion Capture (PCC) January 2012, Global Carbon Capture and Storage Institute, Canberra, Australia. https://www.globalccsinstitute.com/archive/hub/publications/29721/co2-capture-technologies-pcc.pdf
  11. 11.Commercially Available CO2 capture technologies, POWER, Aug 1, 2009. https://www.powermag.com/commercially-available-co2-capture-technology/
  12. A critical analysis of CO2 capture technologies; by Jha, A., Ravuru, V., Yadav, M., Mandal, S., Das, A. K.; Hydrocarbon Processing, June 2021. https://www.hydrocarbonprocessing.com/magazine/2021/june-2021/sustainability/a-critical-analysis-of-cosub2sub-capture-technologies
  13. World’s Largest Post-Combustion Carbon Capture Project Completed, POWER, Jan 10, 2017. https://www.powermag.com/worlds-largest-post-combustion-carbon-capture-project-completed/
  14. What are the top carbon capture and storage projects around the world?; NS Energy,19 July,2019; https://www.nsenergybusiness.com/features/top-carbon-capture-storage-projects/
  15. Alstom’s chilled ammonia CO2-capture process advances toward commercialization; POWER, Feb 15, 2008. https://www.powermag.com/alstoms-chilled-ammonia-co2-capture-process-advances-toward-commercialization/
  16. Alstom Announces Successful Results of Mountaineer Carbon Capture and Sequestration (CCS) Project; Alstom Press Release, 5 May 2011. https://www.alstom.com/press-releases-news/2011/5/alstom-announces-sucessful-results-of-mountaineer-carbon-capture-and-sequestration-ccs-project
  17. CO2 Capture from SMR type flue gas using CESAR1 solvent at Technology Centre Mongstad; by Sundus Akhter , Ahmad Wakaa , Anette Knarvik, Erik Gjernes, Ida M. Bernhardsen, Muhammad I. Shah, 16th International Conference on Greenhouse Gas Control Technologies, GHGT-16 23rd -27th October 2022, Lyon, France
  18. First Process Results and Operational Experience with CESAR1 Solvent at TCM with High Capture Rates (ALIGN-CCUS Project); by Christophe Benqueta, Anette Knarvik, Erik Gjernes, Odd Arne Hvidsten, Eirik Romslo Kleppe, Sundus Akhter; 15th International Conference on Greenhouse Gas Control Technologies, GHGT-15, 15th– 18th March 2021 Abu Dhabi, UAE.
  19. Large Pilot Testing of the MTR Membrane Post-Combustion CO2 Capture Process; U.S. Department of Energy, National Energy Technology Laboratory, Project No. FE0031587, 2018.

Welcome to this website