Most people have at least a vague idea of what a data centre is. Movies show long, dimly-lit rooms closely packed with racks of humming, blinking computers. Bigger than ‘HAL’ in 2001: A Space Odyssey, more like the Matrix or the villain’s setup in James Bond’s Skyfall, or best of all, Transcendence, perhaps. Surely one of the MAMAAs (Meta, Apple, Microsoft, Amazon, and Alphabet) has the mother of all data centres, somewhere. Indeed. Data centres are central to the digital era, and without them, life as we know it is not possible.
Your Google search, Takealot order, Uber ride or Wikipedia knowledge – and of course the telecommunications that make all that possible – work because those orders, requests and transactions are executed, processed and fulfilled in a data centre somewhere. At the last count, there were at least 8 340 data of these worldwide. The biggest market is, naturally, the birthplace of the Internet, the United States, with 2 762 data centres. Next up are Germany (485), the United Kingdom (458), China (447) and Canada (385) – Canada will be explained later in this article. London has the single greatest concentration of data centres (195), followed by Dallas (153) and the San Francisco Bay/Silicon Valley area (151). Then there is Africa …
Africa has more internet users than the United States, but has fewer data centres than Spain. That’s changing fast. On a youthful, fast-growing continent, demand for internet-based services is booming, and Africa’s internet economy is expected to reach $180 billion – just above 5 per cent of the continent’s gross domestic product (GDP) by 2025. Since 2016 demand for data centres has doubled, to more than 250 MW (power consumption is a commonly-used proxy for storage capacity) and at least another 1 200 MW will be needed by the end of the decade, according to the International Telecommunication Union (ITU).
South Africa is the dominant data centre market in Africa, with 55 of the continent’s 121 data centres, according to Cloudscene, an Australian company that monitors such things. These data centres are mostly clustered in and around Johannesburg (31) and Cape Town (11). Durban has five data centres, Gqeberha two, and there are six others in regional centres such as La Lucia and Secunda. But to put that into a global context, the South African market is roughly the same size as Madrid’s.
Elsewhere in Africa data centres are housed in Kenya (10), Egypt (8), Nigeria and Tanzania (5 each), Morocco and Uganda (4) each, Angola, Ghana, Mauritius and Zambia (3 each), Democratic Republic of the Congo (DRC), Ethiopia, Gabon, Mozambique and Rwanda (2 each). Algeria, Cameroon, Côte d’Ivoire, Djibouti, Libya, Namibia, Senegal, and Zimbabwe have a single data centre each.
The major data centre operators nationally are largely home-grown: Africa Data Centres, Business Connexion, Dimension Data, Internet Solutions, Technology Corporate Management, and Teraco Data Environments. Teraco, founded in 2008, is South Africa’s largest data centre provider, with seven centres – in Johannesburg, Cape Town, and Durban – with a combined power capacity of 75MW. By one measure of size – the number of service providers hosted – Teraco’s JB1 East & West centre is the second biggest worldwide, with 306 clients, after Telehouse London’s Docklands North centre with 388.
The latest South African addition is an 18 500m², R3bn facility near Johannesburg built for international software giant Oracle, commissioned in January 2022. Venerable South African IT company Dimension Data (founded in 1983) and its parent, Nippon Telegraph and Telephone (NTT) commissioned the first phase of its 12MW ‘Johannesburg 1’ data centre in April 2022.
African Data Centres, with nine data centres in South Africa, Kenya and Nigeria, is expanding its capacity in Johannesburg to 100MW of IT load. Teraco is completing its R4 billion JB4 centre in Isando, which will be the largest in Africa with 16 000m2 of hall space and 38MW of critical power load when commissioned by mid-year.
This is a fast-paced industry, and JB4 is not going to hold its crown for long – US-based Vantage Data Centers intends to bring the first phase of a R15-billion, 80MW, 12-hectare campus near Midrand online toward the end of the year. Vantage is a global provider of ‘hyperscale (very large) data centres, with 25 campuses on five continents, and its entry into South Africa shows a growing international appetite for the African market. It’s no longer the province of home-grown enterprises.
Exactly what is meant by ‘data centre’? In theory, any dedicated space within a building, or a building or group of buildings housing computer processing and storage systems and communicating via the internet is a data centre. In practice, and in the context of this article, they are dedicated buildings, or dedicated ‘campuses’.
Data centres grew out of the mainframe computer rooms of the 1940s and 50s. The first purpose-built data centre was a military installation, the United States Army’s Electronic Numerical Integrator and Computer (ENIAC), which hummed into operation in December 1945. This vacuum tube-based machine, designed to calculate artillery trajectories, required 170 m2 of floor space and 150 KW of power to process around 5 000 operations per second. It was revolutionary, as it could calculate in 30 seconds a trajectory that took a human ’computer’ 20 hours. One ENIAC thus replaced 2 400 people, but by the time it came into operation the guns of WWII had fallen silent, and it calculated Cold War rocket and missile trajectories instead.
Mainframe computing rapidly went commercial, with industry heavyweights such as IBM, ICL, NCR, NEC and Sperry dominating the age of ‘big iron’ with their enormous computer rooms. But data centres as we know them came of age in the 1980s with the rapid adoption of personal computers and Unix-based ‘client-server’ systems, providing clients who could not afford their own very expensive mainframes computing power far beyond what their desktop computers could offer.
During the ‘dot-com’ boom of the 1990s corporations such as Amazon and Google built enormous data centres, initially for their own purposes, but later providing computing services for other businesses. And they can be enormous: currently, the largest data centre in the world is China Telecom’s 999 999m2 Inner Mongolia Information Park Data Centre in Hohot, the capital of Inner Mongolia. Its square kilometre footprint would hold 5 882 ENIACs, and its 150MW power draw would require most of the output of South Africa’s largest solar farm, Solar Capital’s 473-hectare, 175MW De Aar project.
Data centres fall broadly into two categories: single-user and multi-user. Dedicated ‘enterprise’ data centres serve one organisation, particularly in the financial, telecommunications, industrial and defence sectors. But there are many more ‘colocation’ (or ‘colo’) centres that serve multiple clients, and cloud data centres where data and applications are hosted by providers such as Amazon Web Services (AWS), IBM or Microsoft. These colo centres are invariably carrier-neutral (or network-neutral), and not tied to any particular fibre network, thus providing interconnection and redundancy.
In the context of the South African – and wider African – market the main interest is in developing carrier-neutral colo centres, with several of them on a ‘hyper’ – very large – scale.
There is a widely-accepted standard for data centre design and infrastructure, ANSI/TIA-942 (developed as an American National Standard by the US-based Telecommunications Industry Association), specifying efficiency, electrical design, fire safety, mechanical systems, network architecture, physical security and redundancy, in four categories, or tiers.
Tier 1 is fairly straightforward, with limited protection against physical events and a single distribution path, though to comply a data centre must have an uptime of 99,671% (less than 28 hours, 48 minutes of downtime annually). Tier 4 provides the highest levels of fault tolerance, redundancy, backup power and the like. Tier 4-compliant data centres are required to have an uptime of 99,995% (no more than 26 minutes, 18 seconds of downtime annually) and are pretty much impervious to any events bar a meteor or missile strike. Naturally, that 0,324% difference between tiers 1 and 4 costs a mint of money, and certification is also costly. Currently, there are 13 certified colocation facilities in South Africa, according to Cloudscene.
The ANSI/TIA standards are not the only ones that may apply in the data centre sector. The Payment Card Industry Data Security Standard (PCI DSS) is an information security standard for organisations that handle credit and other payment cards and systems. International Standard on Assurance Engagements (ISAE) certifications show that an organisation has stringent internal auditing controls, which are important for data security. There are also several International Organisation for Standardisation (ISO) certifications around information security management and quality control. Historically, South Africans have tended to favour the EMEA (Europe, Middle East and Africa)-orientated ISO standards over North American ones.
So, there are data centres and there are data centres. Defining them and counting them is rather subjective. The secretive ones run by intelligence agencies, military organisations, cyber warfare operations and defence contractors are, naturally, elusive. They are being built so fast it’s hard to keep track. This report relies on figures from Cloudscene.com, a connectivity directory.
Apart from the terrific perceived potential, one of the factors that makes the African data centre market attractive is the ‘leapfrog’ effect. Much of Africa has sparse, creaky infrastructure, frequently mismanaged by inefficient government or parastatal entities. Erratic power supplies, skimpy fixed-line networks, and colonial-era infrastructure and banking systems have impeded growth across much of the continent for decades. Today’s technology bypasses many of those systems. Cellular and satellite communications and alternative energy sources – and, it must be said, an enormous appetite for embracing change – have allowed investors to leapfrog these hurdles.
South Africa is an example. Fifteen years ago local internet users were pretty much limited to what Telkom (generally referred to by a host of other, less-than-flattering names) offered on its fixed lines – DSL for urban fortunates and dial-up modems for the rest. (This writer remembers, with some pain, an anaemic and erratic Telkom ISDN service that cost more than his car repayments.) Today Telkom remains a substantial player (despite a near-death experience as it came to grips with telecommunications deregulation) but is simply one of many network operators.
The marvels that cellular data, internet access and off-grid power have brought to Africa are hard to understate. Sub-Saharan Africa already has more than half a billion unique mobile subscribers, with twelve countries, namely Seychelles, South Africa, Botswana, Mauritius, Côte d’Ivoire, Gambia, Gabon, Ghana, Mali, Namibia, Senegal, Cabo Verde and Kenya, having far more cellular subscriptions than citizens.
The growth has been continent-wide. Between 2019 and 2021, Internet use in Africa jumped by 23 per cent. That trails global growth: international bandwidth usage in 2021 totalled 932 terabits per second (Tbit/s), a 30% increase on the 719 Tbit/s in 2020. This surge matched a similar increase in 2019. Recent growth in internet usage in the rich world was partly driven by the coronavirus pandemic, and the accompanying surge in videoconferencing, remote working and online commerce. In Africa covid-19 was certainly a growth factor, but not as great a one as simply the increased availability and access to digital technologies.
Access remains uneven, however. Despite a 21 per cent increase in 4G coverage since 2020, around 18 per cent of the African population remains without any access to a mobile broadband network. Just over half of urban dwellers are online, compared with just 15 per cent of the rural population. Access can also be expensive: the ITU reckons that affordable broadband access should cost less than two per cent of the monthly gross national income (GNI) per capita, but Africa remains exorbitant, at around 18%.
Coverage is of course better in cities and towns, many of which also have fast-growing urban fibre networks – and plenty of young people. Africa, particularly the sub-Saharan apart, is a youthful continent, with 55% of the population aged between 15 and 64 – the economically-productive years. This ‘youth dividend’, which earlier propelled Chinese and South-East Asian growth, is one of the factors that excites economists and financiers.
This youth dividend and leapfrogging have driven an explosion in digital services. Africans have been particularly innovative in technologies such as mobile banking, drug delivery by drone, agricultural advice and services and, perhaps surprisingly, government e-services. Kenya’s M-Pesa branchless banking service has become a global byword for mobile, peer-to-peer finance, Uganda’s FundiBots provide robotics training in schools, Botswana’s Deaftronics provides solar hearing-aid battery chargers, and solar-powered robotic traffic cops regulate traffic in Kinshasa.
Across much of the continent, even in the bits that seem perennially unstable, the picture is broadly similar. The potential is so large that investors are upbeat, if not downright hungry. In 2020, investment in the continent’s data centre market was around $2 billion (around R30 billion). That’s expected to more than double in the next four years, reaching $5 billion by 2026, according to Africa Data Centres, one of the continent’s bigger data centre providers. South Africa is expected to account for the bulk of investment over that period, reaching an estimated $3.1 billion (R46 billion).
There are many reasons for South Africa’s outsized data centre footprint. More subsea optic fibre cables land here – 13 of them – than anywhere else in sub-Saharan Africa. Together these have an installed capacity of 178 Tbit/s, and another two cables with an additional 280 Tbit/s will light up in the next two years.
One of these subsea cables, 2 Africa, will be the world’s longest, at 45 000km, and will provide 27 landings in 19 African countries when it is completed toward the end of 2023. Using spatial division multiplexing (SDM) technology, which deploys up to 16 fibre pairs instead of the 8 pairs supported by older technologies, it will deliver more than the total capacity of all subsea cables serving Africa currently. Overall subsea capacity serving Africa is tiny as a proportion of the worldwide 2021 total of 932 Tbit/s, but its doubling within such a short space of time says a great deal about future growth.
The first data centres were sited at peering points where internet networks meet or undersea cables come ashore, and substantial clusters developed at places such as the US coastal state of Virginia, Dublin, London, Amsterdam, Hong Kong, Singapore and Tokyo. Access to undersea links still plays a key role, and African data centres are largely in coastal countries with landing points.
Rapid provision of terrestrial fibre networks has, however, changed this traditional siting requirement. Take South Africa – Johannesburg is more than 900km from the nearest undersea landing point at Mtunzini, KwaZulu-Natal – and the SA fibre backbone is substantial and growing, with more than 200 000 km of fibre in place. In addition to the backbone networks of telecommunications majors Telkom, Vodacom, and MTN, major fibre providers include Broadband Infraco (±15 000 km), Dark Fibre Africa (±10 000 km), Liquid Telecom (±10 000 km), Vumatel (±8 000 km); and Seacom (±4 000 km). Seacom is the venerable grand-daddy of the local fibre family, having commissioned the first commercial broadband undersea cable to South Africa in June 2009.
Ideally, data centres are sited not just on network nodes, but as close to their clients as possible, reducing network costs and latency issues. However, there are many other factors that influence location, including energy supply, physical security, geological and climate stability, workforce availability and appropriate infrastructure and services.
Data centres require plenty of reliable energy, and indeed energy consumption is used as a proxy for capacity. South Africa has, by sub-Saharan standards, relatively cheap and reliable electricity. At around R1,25 per bulk kilowatt/hour (kWh) it’s cheaper than Nigeria (R1,44), Kenya (R2,66) and even the global average of R1,92 kWh. True electricity costs are difficult to determine, as data centres operators negotiate rates with local authorities, national utilities or independent producers. South African metros, which derive a fair slice of their income from electricity sales, welcome these energy-intensive users.
In energy supply, South Africa has belatedly entered exciting territory. As of June 2021, independent power producers (IPPs) were permitted to generate up to 100mW without a licence. This long-overdue move, coupled with Eskom being obliged to spin off its transmission arm into a generation-neutral regional distribution net, has energised the local IPP market. The appetite for new projects was evident in the outcome of the fifth ‘bid window’ held by the national Department of Mineral Resources and Energy (DMRE), where 25 producers were selected for the department’s bluntly-named Renewable Energy Independent Power Producer Procurement Programme (REIPPPP) in October 2021. Together the successful bidders will add almost 2 600 MW of new capacity – around 1 600 MW from wind energy and 1 000 MW from solar photovoltaic (PV) plants.
There’s still a lot to be addressed in the SA energy sector, from supply bottlenecks and delays in the provision of suitable transmission and sub-station capacity to complex ‘wheeling’ (energy transmission) arrangements, but a future no longer monopolised by the state’s corruption-ravaged energy utility, Eskom, is bright. Literally. Most of sunny South Africa averages more than 2 500 hours of sunshine per year, with average solar-radiation levels of between 2 100 and 2 300 kWh/m2 a day. Cheap land in the Northern Cape and Karoo, both relentlessly sunny, is attractive, and solar panel technology is cheaper than ever before. Costs for electricity from utility-scale PV fell 85% between 2010 and 2020, according to the International Renewable Energy Agency (IRENA). South Africa will never enjoy the ultra-cheap hydropower that gives Canada, parts of China and Norway an edge, but with the way renewables are going, the gap is shrinking.
For similar reasons – cheap land and diminishing input costs – wind energy is being harnessed at a clip, particularly in the three Cape provinces. Currently, installed solar power capacity is around 6GW, and wind 2,7GW, according to IRENA’s most recent data. Together with the winning bidders in the latest REIPPPP round’s additional 2,6GW, utility-scale renewables will provide around 19% of South Africa’s generation capacity of approximately 58 000 GW/h. That’s a nominal capacity – renewable energy does not work when there’s no sun or wind, which is why fossil fuel- or nuclear-powered ‘baseline’ generation capacity is needed. But the South African private sector is very much alive to energy retention technologies such as concentrated solar power (CSP), which stores solar energy in a medium such as molten salt, and the very rapid advances in battery technologies (much of the development in the latter sector has a local element – it has been driven by the energetic Pretoria-born Elon Musk and his Tesla enterprise).
Eskom’s ‘load-shedding’ (how delightful that customers are seen as a ‘load’) has given South African businesses ample experience in providing their own power, and data centre operators are no exception. They typically have agreements with their primary energy supplier to ensure continued supply during rolling blackouts and have impressive back-up facilities, such as impressive diesel generators and many days’ worth of fuel.
In data centres, power usage is an all-absorbing topic, and the metric called power usage effectiveness (PUE) is practically an object of worship. Energy is needed not just for the racks and racks of servers, but for cooling, lighting, management systems and more. A PUE reflects the proportion of the power used for computing against overall energy demand (a PUE of 1.0 would be the perfect score). According to the Uptime Institute, the average worldwide PUE in 2020 was 1.58.
That data does not tell the whole story; older data centres are by definition less effective. Today hyperscale facilities can dial a PUE down to about 1.2. They do this in part by paying enormous attention to detail. Servers are stripped down to bare essentials – there are no video ports or blinking lights – lighting is by demand, and excellent insulation is essential.
Cooling remains the biggest power draw after the servers themselves, and in some data centres cooling can take more than a third of the energy supply. Being in a cool climate helps. That is one of the reasons why so many US data centres are on the cool Pacific coast, why chilly Canada is the fifth-largest market, and why the Chinese have so many servers in inner Mongolia, where an average temperature of 6°C permits ‘free air’ cooling for two-thirds of the year.
Data centre cooling is a complex technical field with many variables, and is beyond the scope of this article. Broadly, it means keeping to temperatures of between 21 and 24ºC in server rooms, as efficiently and cost-effectively as possible, usually through air-conditioning systems, liquid cooling or a combination of both. ‘Free air’ cooling through low ambient temperatures is, of course, the ideal, but has to be augmented in sunny South Africa. Humidity must also be controlled, to prevent condensation on electronic components, and the server environment kept dust-free.
One of the flaws of the PUE yardstick is that it does not take ambient climate into account. This is fairly obvious in the Uptime Institute’s 2010 regional rankings, where Africa (overall) and the Middle East have average PUEs of 1.79. By a PUE measure, a Canadian data centre cannot reasonably be compared to one in Johannesburg, which has an average daily temperature of 25.6°C and summer peaks of 38°C. Still, South African data centres do very well. The national average across cooler coastal and hotter Highveld locations is 1.5, according to a CAP DC white paper in 2020. In practice, locally newer data centres aim for and achieve PUEs of between 1.4 and 1.3, the envy of many providers in similar climates.
In the industrial era, assets were tangible and safeguarded in bank strongrooms behind mighty safe doors and thorough elaborate client verification systems. In a digital world, data centres are the new strongrooms. They too have elaborate physical access control systems, including biometrics and constant video monitoring, and patrolling security officials. Thus, data centres are physically some of the most secure facilities to be found. It’s a great deal easier to visit a bank branch than it is to pop into your data host unannounced, and unlike banks, data centres are seldom burgled. The last reported major burglary of a data centre was in 2007, when five thieves posing as police made off with US$4 million-with of servers from a Verizon data centre in London.
But there’s always the lunatic fringe. Last year a 28-year-old Texan was sentenced to ten years’ imprisonment for planning to blow up an Amazon Web Services operation in Virginia, USA. Seth Pendley told the FBI undercover agents he was attempting to buy explosives from that he wanted to ‘destroy 70 per cent of the internet’, perhaps subscribing to an inaccurate but oft-repeated belief that 70 per cent of global Internet traffic runs through Virginia. But then Mr Pendley has form: he also claimed to have been present at the January 2021 attack on the US Capitol.
The greatest threats don’t enter a data centre through the door. They come flickering in through the fibre. These threats are legion. Distributed denial of service (DDoS) attacks, web and application attacks, cache poisoning, phishing, ransomware … criminal ingenuity knows no bounds. Malicious behaviour is not necessarily driven by private financial gain. Governments and their cyberwarfare arms want to confound their adversaries by attacking digital services. These need not be obvious ones, such as military communications and control centres. Simply disabling water purification plants, traffic control systems or power transmission switches can do enormous damage. Witness the cyberwarfare around Russia’s invasion of Ukraine.
It’s not just state actors getting into that conflict. The hacktivist collective Anonymous took it upon itself to attack Russian facilities and services, claiming it hacked TV stations to show war footage that obviously the Russian state would not like its citizens to see. This adds a new dimension. In the event of a truce, who does one call at Anonymous?
Regardless of the origin of the attacks, or the motives of the attackers, data centre operators must see them off. Data breaches are, naturally, under-reported. Few people would like to admit that they left the window open or neglected to set the alarm, and service providers are reluctant to admit that their offerings are anything other than outstanding. But that’s another story: data security is a complex, fast-changing field and a massive industry, quite beyond the scope of this article.
In a building containing thousands of stacked and racked – and hot – servers, thousands of kilometres of electrical cabling and complex power provision and management systems, fire is a concern – but happily a rare event. The Uptime Institute recorded just 11 ruinous fires since 1994, though there have been more than 8 000 reported fire-related incidents over that period. The most recent, in March 2021, was the total destruction of a 2 MW facility housing 30 000 servers in Strasbourg, France, belonging to OVHcloud, one of the largest hosting companies globally. Apparently the affected servers hosted 3.6 million websites, including French, British, Polish and Ivory Coast government platforms. So much for the ‘digital sovereignty’ many nations claim to want.
Fires are rare because data centres have excellent fire management and suppression systems, far more sophisticated than those in other commercial environments. Data storage equipment is very sensitive to temperature changes, so even a small fire can have severe impacts. Fires seldom start in the areas housing servers, ‘white space’, in the jargon. They are far more likely to occur in electrical supply and backup power systems, or in administrative areas.
When a fire is detected, it may be suppressed with water mist or ‘clean agents’, such as inert non-combustible gases. Gas suppression is favoured, as once a fire is extinguished, gas can be easily removed by a climate control system. Indeed, in data centres such systems will usually be designed to deliver effective heat dissipation and gas evacuation in the event of fire. Gas systems also don’t carry the risk of water damage, and leave no residue.
South Africa has many advantages beyond connectivity, location and energy. Growth in the South African data centre industry is supported and underpinned by a host of other factors, including skilled, sophisticated and deep engineering, IT and financial sectors, operating in a fairly mature and stable regulatory environment.
Start with the money. Data centres are seen as very attractive prospects by the property investments sector, which is adapting to a post-covid world where shopping centres and office space in a work-from-home world are less desirable, and where data centres – and their relations, logistics and fulfilment warehouses – are very much in vogue.
There are many forms of ownership, from data centres that are wholly owned by their operators, to ones funded by private equity or real estate investment trusts (REITs). Whatever the flavour, South Africa’s sophisticated and deep banking and finance sectors easily provide the huge sums involved and comfortably manage foreign direct investment (FDI) flows.
South Africa has long prided itself on its many outstanding consulting, design, engineering, construction and IT firms, some of which, such as the owner of this site, operate across Africa and indeed the world. There is a deep pool of the skills and expertise required, and overall the construction industry is cautiously optimistic about improving prospects after the miseries of the past two covid-shaped years.
Although South Africans frustrated by their public sector might not always think so, by continental standards the republic does have a mature and stable regulatory and administrative framework. Building plans are passed, servitudes are granted and intellectual property is respected. South Africa is not being quite as nimble as some other African countries in developing enabling legislation and implementing it, and it sometimes isn’t even very good at simply doing what it said it would, as the delayed migration to digital TV and 5G spectrum auctions demonstrate. It remains, however, a stable enough environment overall to reassure investors.
There are, of course, challenges. The travails of the run-down Eskom, and its infamous, frequent rolling blackouts are a constraint not just on the data centre industry but on the economy as a whole. Simply the fact that a data packet transmitted from the southern tip of Africa to Europe and back can take 180 milliseconds may be a mild frustration to high-speed traders. There are also structural problems, including social instability – consider the riots and looting in mid-2021 – poor policing and prosecution practices and erratic or ineffective government policies that might give potential investors pause. But obviously, these are issues that pale before the promise the region holds.
As this report outlines, the future is very promising indeed, and this continent has long attracted the ambitious and the resourceful. The 1871 discovery of the 83.50-carat diamond on the slopes of Colesberg Kopje led to Kimberley and the Big Hole, and the ‘Rand Rush’ of 1886 led to the founding of Johannesburg. Prosperity flowed from that. Extractive industries remain a significant part of African prosperity, but now there is a new scramble for Africa. This time, it’s often Africans at the forefront.
The raw materials might not be things that you can drop on your foot, but intangible bits and bytes are the new commodities. Just as minerals could not be mined without headgear, power stations and railways, data can’t be ‘mined’ without data centres and all the finance, technology and skills behind them. There’s a new gold rush, and market-makers are convinced of that. You might like to check with your pension fund’s asset managers that they are of similar thinking. You will probably be well rewarded.
A data center is a facility consisting of computer networks, storage systems and computer infrastructure for businesses and other organizations that use to organize, process, store and distribute large amounts of data. An entity generally relies heavily on applications, services and data contained within a data center, making it a focal point and an important asset in day-to-day operations.
Business data centers are increasingly incorporating security and protection services for cloud computing services, as well as internal, on-site services. As businesses gradually turn to cloud computing, the boundaries between cloud providers’ data centers and business data centers become less clear.
The data center allows an organization to compile its resources and infrastructure for data processing, storage, and communication, including: storage, sharing, access, and processing data across local infrastructure to support data processing and data communications; and services such as cooling, electricity, network access and uninterrupted electronic devices (UPS).
Collecting all these resources in the database enables the organization to:
protect proprietary systems and data; integrate IT and data processing staff, contractors, and vendors; apply information security controls to identity systems and data; and identify the economy of scale by integrating sensitive systems into one area.
Data centers support almost all accounting, data storage, and business applications. To the extent that a modern business enterprise is run by computers, a data center is a business. Most businesses need to store data – whether it’s for their email, website, online transactions, etc. and Other factors include regional usage, infrastructure development, transportation, and anything else that can affect data centers. Currently, SDWAN technology has become popular and is becoming a trend of a new era. This technology will simplify life and be ready for use by all stakeholders. In traditional data center technology, MPLS is used to connect remote branch offices to a centralized data center, and all communication with the data center is via MPLS. For example, if someone has email or ERP, the communication is over the WAN using MPLS technology. But we are talking about the one used in 2003. Until then, by 2022, SDWAN will make life easier because everything happens using a cloud like AWS or Azure. Traditional WAN architectures have been limited to enterprises, branch offices, and data centers. As organizations adopt cloud applications in the form of SaaS and IaaS, applications will explode in WAN architectures to access globally distributed traffic. These changes have had a huge impact on IT. SaaS application performance issues can hamper employee productivity. Global network costs can increase due to inefficient use of dedicated and redundant channels. IT departments work every day to connect different users with different types of devices to different cloud environments. It helps remote branches and can get data anytime, anywhere. This is useful for SaaS applications that you use frequently, such as Office 365, and helps users get and use information when they want to access it. Data centers now use SDWAN technology. In general, solutions are expensive and not everyone can afford, so they cost a lot of money and budget. These high-tech companies are definitely moving to SDWAN to continue to develop the technology and take full advantage of its benefits.
Data centers can vary greatly in size. Some locations are just a few hundred square feet, while others are over an acre. Digital Realty’s Oakland data center has 55,000 square feet of raised floor space in a 122,000square-foot building, for example, while the Digital Realty Houston data center building is 50,000 square feet in total.
Data center objects are usually divided into three categories:
The modern data center focuses on the organization’s data systems for virtual secure infrastructure, including:
Database services usually include:
All of this requires a virtual environment with secure access controls and enough square images to maintain a collection of infrastructure and resources.
Datacenter management requires managing a few different topics related to the data center, including:
There are now different categories in the data centers that will be discussed in detail. As we know there are different types of attacks that can damage the network. Perhaps, network security is an important factor considered to protect segments. We will be discussing the different categories that will protect the network from this type of attack.
The Internet section will take care of the traffic of users who need an Internet connection for Limited Security and communication design. The diagram below shows the design

Since Internet-enabled VM servers can be moved to a different DMZ location, the firewall will split the L2 & L3 domain to create a DMZ location on the server farm to access a specific server.

The LAN Firewall component will take care of the entry and security of eligible ABL local users, voluntarily other clients may be subjected to wall testing if required.

Repetition will be performed between the main sites and the DR using a recurring router, which is recommended to pass recurring traffic in the firewall test.

BGP (Border Gateway Protocol) will be used with WAN segments as a sub-protocol with MPLS providers to obtain NLRI (Network Layout Information) to establish a DMVPN Tunnel between sites.
Modern data centers make extensive use of monitoring and management software. The software, which includes DCIM tools, allows remote IT center managers to manage location and tools, measure performance, detect failures and perform multiple repair actions without actually entering the data center room.
The growth of virtualization has added another important dimension to data center infrastructure management. Virtualization now supports server deployment, networks, and storage, which allows all computer resources to be organized into pools regardless of their actual location. Administrators can then provide operational load, storage conditions and even network configuration in those common resource pools. If administrators no longer need the equipment, they can return it to the swimming pool for reuse. The entire network of actions, storage and virtualization of the server can be done with software, providing the term of the software defined in the software.
Data center designs also recognize the importance of energy efficiency. A simple data center may require only a few kilowatts of power, but business data centers may require more than 100 megawatts. Today, the green data center, designed with minimal impact on the environment through the use of low-emission building materials, catalytic converters and other energy technologies, is growing in popularity.
Data centers can also maximize efficiency with their visual architecture using a method known as the hot spot and cold architecture. Servers are lined up in alternating rows where the cooling inlet is facing one direction and hot air outlets in the other. The result is a rotation of hot and cold corridors, exhauses create a hot spot and inputs create a cold environment. The exhauss points to the air conditioner. Utilities are usually placed between server cabinets in the queue or hallway and distribute cold air back to the cold area. This suspension of the air conditioning device is known as line cooling.
Organizations often measure the energy efficiency of a data center using a metrics called power consumption (PUE), which represents the total amount of energy that enters a database divided by the energy used by IT equipment. However, the subsequent increase in virtualization has allowed for more productive use of IT equipment, resulting in higher efficiency, lower power consumption and reduced energy costs. Metrics like PUE are no longer the essence of energy efficiency goals, but organizations can still measure PUE and use comprehensive energy analysis and analysis to better understand and manage energy efficiency.
Tier IV data center provides less operating systems and higher security.
Categories can be categorized by available resources, data center capabilities, or overtime guarantees. Uptime Institute defines the data center categories as follows:
Category I. These are the most basic type of data center, and include the UPS. Tier I data centers do not provide idle systems but must guarantee at least 99.671% downtime.
Phase II. These data centers include system, power, and cooling and guarantee a minimum downtime of 99.741%.
Phase III. These data centers offer partial error tolerance, 72 hours of opt-out protection, full downtime, and a 99.982% uptime guarantee.
Category IV. These data centers guarantee 99.995% of downtime – or no more than 26.3 minutes of downtime per year – as well as full error tolerance, system downtime, and 96 hours of downtime.
While almost any suitable space can function as a data center with imagination, deliberate design and use of a data center requires careful consideration. Apart from the basic cost and tax issues, sites are selected based on conditional factors, such as geographical location, seismic stability and weather, access to roads and airports, access to power and communications, and the prevailing political climate.
Once the site is secure, the architecture of the data center can be designed with due regard to the mechanical and electrical infrastructure, as well as the design and layout of IT assets. All of these problems are driven by the acquisition and efficiency of the objectives of the required data center category.
Database projects should also implement sound security and protection procedures. For example, security often comes from door systems and access corridors, which must be aligned with the movement of large, unmanaged IT assets, as well as allowing employees to access and repair infrastructure.
Fire extinguishers are another important safety feature, and the widespread use of sensitive, electronic, and electronic devices prevents routine spraying. Instead, data centers often use environmentally friendly fire extinguishing systems, which effectively starve the oxygen fire while minimizing co-operative damage. Because the data center is also a core business asset, comprehensive security measures and access controls are required.
These may include:
When used properly, these safety measures can help detect and prevent the inefficiency of employees, contractors, and intermediaries.
There is no need for a single data center, and modern businesses can use two or more database installs in multiple locations to enhance the capabilities and better performance of applications, which reduces delays by placing workloads closer to users.
In contrast, a business with multiple data centers may choose to merge data centers, reducing the number of sites to reduce IT operating costs. Consolidation usually occurs during consolidation and acquisition where the majority of the business does not need the underlying business data centers.
The origins of early data centers can be traced back to the 1940s with the advent of early computer programs such as Electronic Numerical Integrator and Computer (ENIAC). The original equipment was intricate and functional and had many cables that connected all the necessary parts. They were also used by the military – meaning special computer rooms with racks, cable trays, cooling equipment, and access restrictions were required to both install all equipment and implement appropriate safety measures.
However, it was not until the 1990s, when IT operations began to experience difficulties and affordable communication technologies became available, that the term data center came into use. It was possible to store all the required company servers in the company’s internal room. These specialized computer rooms are called data centers within organizations, and the term gained momentum.
During the dot-com boom in the late 1990’s, the need for high speed internet and the ever-present internet presence of companies required larger resources to put in place the maximum amount of communication equipment needed. It was during this time that data centers became popular and began to resemble those described above.
In the history of computers, as computers become smaller and networks become larger, the data center has evolved and evolved to embrace the necessary technologies of the day.
Data centers vary in size, from the small server room to clusters, but they all share one thing in common: they are an important business asset where companies often invest and use the latest developments in data center connectivity, calculation. , and storage technology.
The modern data center has evolved from an institution that contains existing infrastructure to those that integrate local systems with cloud infrastructure where networks, applications, and workloads are actively deployed in many private and public clouds.
Business data centers are usually built and used by a single organization for their internal purposes. These are common among tech giants.
Colocation data centers serve as a type of rental facility where data center facilities and facilities are made available to potential tenants.
Managed service data centers offer features such as data storage, computing, and other services such as an external, customer-oriented service.
Cloud data centers are distributed and sometimes provided to customers with the help of a third-party service provider.
The fact that virtual cloud DC can be downloaded or downloaded with just a few clicks is a major reason for switching to cloud. In modern data centers, software-defined networking (SDN) controls the flow of traffic through software. Infrastructure offerings such as IaaS, hosted on private and public clouds, cover all systems where needed. When new applications are required, Platform as a Service (PaaS) and container technology are readily available.
Many companies are moving to the cloud, but it is not something that others are willing to take. In 2019, it was reported that businesses were paying more per year for cloud infrastructure services than real-time hardware. However, a survey conducted by the Uptime Institute found that 58% of organizations claim that the lack of visibility, transparency, and accountability of public cloud services keeps a heavy burden on corporate data centers.
Your data center is the most important resource within your organization. As you know, it provides access to all of your data storage, management, and distribution systems, applications, and communications. When employees and customers do not have access to servers, storage systems, and network devices located in the data center, your entire organization may shut down. Millions of dollars could be lost in a matter of minutes in businesses such as banks, airlines, shipping companies, and online brokerages. Faced with these results, IT managers today need to upgrade their data centers, such as their Cisco Data Center or others, especially network infrastructure. Considering that 70% of network failures can be caused by surface layer problems, especially cable errors, it is very important to take a closer look at infrastructure construction.
A data center is the home of computer power, storage, and applications needed to support a business environment. The data center infrastructure is located in the center of the IT building, where all the content is taken or passed. Properly planning the data center infrastructure design is important, and efficiency, durability, and scalability should be carefully considered.
Another important aspect of a data center design is flexibility in faster deployment and support for new services. Designing a flexible architecture with the ability to support new applications in a short period can generate a significant competitive advantage. Such a design requires strict initial planning and thoughtful consideration in the downtown areas, uplink access bandwidth, actual server capacity, and over-registration, to name a few.
The design of the data center network is based on a proven layout, which has been tested and developed over the past few years in some of the largest data centers in the world. The horizontal approach is the basis of a data center design that seeks to improve scale, performance, flexibility, durability, and care.
The layers of data center design are the contexts that are contextual, integral, and accessible. These layers are summarized as follows:
Key Layer – Provides a flexible backplane for a high-speed packet for all flow in and out of the data center. The main layer provides connectivity to multiple integration modules and provides a flexible layer of 3 layers with no single point of failure. The main layer uses an internal route protocol, such as OSPF or ISIS, and the load balances traffic between the campus spine and the integration layers.
Integration layer modules – Provide key functions, such as integration of the service module, Layout 2 domain definitions, extended tree processing, and automatic gate duplication. Multi-category server traffic flows through the integration layer and can use services, such as firewall and server load balancing, to configure and protect applications.
Access layer – Where servers attach to a network. Server components include 1RU servers, blade servers with integral switch, blade servers with transit cable, integrated servers, and mainframe with OSA adapters. The network access network infrastructure consists of modular switches, 1 or 2RU rooted configuration, and key blade server switches. The switch provides both Layer 2 and Layer 3 headers, completing the streaming domain for various servers or management requirements.
Principle 1: Space Saving
Environmentally friendly homes are expensive. Datacenter racks and equipment can take up a large number of homes for sale, and the future need for more network connectivity, bandwidth, and storage may require more space. With less space as low as high concerns among IT executives today, maximizing space resources is a very important aspect of data center design. Business conditions are constantly evolving, and as a result, the needs of the data center are constantly changing. Providing more empty floor space when designing your data center allows for flexibility to redistribute space for a specific task, and add new racks and equipment as needed.
Principle 2: Honesty
Uninterrupted service and continuous access are essential to the day-to-day running and production of your business. Since downtime translates directly into revenue loss, data centers should be built on carelessness, insecurity, and availability. Datacenter reliability is also defined by infrastructure performance. As information is sent back and forth within your facility and abroad, large data sources are transferred to and from the machine environments at very high data rates. The infrastructure must continuously support data flow without errors that cause redundancy and delays. As networks grow and demand bandwidth requirements grow, the data center infrastructure must be able to maintain continuous reliability and performance.
Principle 3: Management
Management is the key to improving your data center. Infrastructure must be built as a reliable and flexible resource to meet disaster recovery, development, and disaster recovery. Strategic management, integrated cable management that keeps cable and connections maintained and organized in a way, easy to find and access, and easy to redesign.
Cable rail routes should be clearly defined and easy to follow while allowing for easy installation, separation, access, reduced congestion, and growth area. This is especially important for data centers with a large volume of cables. Cables operated in this way improve network reliability by reducing the risk of cable damage, curved radius breakage, and the time required for identification, tracking, and rearrangement of cables.
The use of a central patch in the connection mode provides a sensible and easy-to-manage infrastructure where all network features have a permanent supply cable that has been disconnected, and can no longer be handled. The benefits of using a centralized lease on your data center include:
Reduce operating costs by significantly reducing the time it takes to repair, upgrade, and maintain.
Improved reliability by making changes in the amendment area can facilitate the connection of sensitive assets.
Reduced downtime risk by being able to split network components to resolve a problem and resume circuits in a disaster recovery environment.
A global epidemic has brought a new set of challenges to the world. It has forced companies to work remotely and to teach far-flung schools – and in many cases, to accelerate their creative process. As a result, the need for faster access to information has become a major challenge for data centers. According to Statista.com, the total amount of data created, copied, copied, and used worldwide is estimated to reach 79 zettabytes by 2021 generally, most of you are driven by IoT growth, it is not an easy task. The epidemic has highlighted the important role of data centers not only in ensuring that IT companies operate but also in the daily lives of ordinary users.
The data center services market was estimated at $ 48.9 billion by 2020. It is estimated that by 2026 this figure will rise to $ 105.6 billion.
We see significant growth in technologies that require data centers – for example, the growing demand for cloud services, whose providers prefer external data centers. This is a trend as internal data centers require enormous investment, both in their design and subsequent maintenance.
One of the consequences of the global epidemic was the way work changed online. Although, in line with this, the number of employees allowed on site is significantly reduced in many countries. One of the ways in which future data centers will deal with such problems is to do automated work fully or partially, by optimizing AI and Robotic Process Automation (RPA) solutions.
Edge computing will play a major role in the development of future data centers. As more and more people find smart solutions, not only in companies but also in their own homes, the demand for edge computing will continue to grow, as will the demand for computer peripherals. This will change data centers as computer power transfers will have a direct impact on the type of data center we will see in the future. According to Statista.com, the value of a smart home market globally will rise to $ 53.45 billion by 2022.
It is also worth considering the relationship between edge computing and the 5g network as an alternative to older data centers, which will allow for faster development of AI or IoT-related applications.
Edge computing allows data to be processed closer to the source, reducing latency. This may lead to the development of mobile data centers, which can be easily accessible, for example, near major sporting events, concerts, etc. This solution can also eliminate network problems.
As businesses become more aware of climate change and are urged to take immediate action, data centers also need to incorporate sustainability into their strategies.
According to the Journal of Science, data centers accounted for 1% of total global energy use. However, the activity of data centers between 2010 and 2020 increased by 6 times, while the rate of power consumption did not increase in proportion to these numbers. This reflects advances in data center technology in the form of new CPU technologies and energy-saving storage solutions such as Non-Volatile Memory Express (NVMe).
However, future data centers are set to be more environmentally friendly. Demand for data storage will certainly not decrease, but data centers will grow and improve their use of data compression, duplication, and other ways to improve efficiency. An additional feature is that the cooling of modern data centers is done by liquids or so-called impenetrable systems. Air cooling, which has been used to date to maintain good server performance, consumes a large number of resources. Liquid cooling, on the other hand, allows for a rapid decrease in temperature and energy consumption and is often set as a closed natural cycle. Slightly cooler systems with the latest technology in terms of components that use less energy and tolerate higher temperatures will become more prominent in the future.
Future data centers are also being designed and optimized for optimal performance. A good example of this is Google, Facebook, and Amazon, who have purchased land in Sweden for the construction of data centers, as in a cool environment few resources are needed to cool the servers. Microsoft is taking a very unusual, but very promising route with Project Natick, exploring options for submitting underwater datacenters. Located at the bottom of the ocean, covered with depleted oxygen, moisture, and nodules, data centers can appear to thrive. At least the Naticks underwater data center with 864 servers and 27.6 decibate disk (approximately 27.6 million gigabytes) showed a failure rate of 1/8 of the global control group, according to Microsoft. And with natural sea water acting as a coolant, it will be a natural victory.
Data centers are important to the web. They handle online storage tools. Includes server racks, multiple cables, and a list of other resources. Tools store information you find on websites and other online platforms. They have to stay and work well at all times, otherwise these stadiums will not be accessible. Data centers are designed to keep servers running and operating at the appropriate levels. The data center must meet certain requirements in order to be considered efficient and reliable. So, what really goes into data building and construction?
Here is a summary of five key elements that every data center needs to address.
Data centers use more power than developed countries. Globally, data centers use more than 200 terawatts per year. They need power to keep servers and other important things in place – power outages lead to costly downtime and resource damage.
Data centers derive most of their power from the power grid. Many switch to green energy practices such as harvesting solar energy to supplement the supply from the grid – and reduce the impact on the environment. It is also important that every data center should have a power supply system (UPS) to avoid power outages.
Note: The energy demand for power stations continues to grow as servers and other resources become more complex. Thus, data centers should increase their capacity to provide electricity with a special focus on green energy.
Servers and other equipment in data centers generate a lot of heat. The heat builds up in the facility and has to be expelled to protect the equipment–the heat damages servers and other equipment and can even start fires.
Every data center should have efficient cooling solutions. There is a variety of cooling solutions, and every solution comes with varying requirements.
Cyber-security has been a trending topic in the past. However, even the most advanced of online security measures have no effect other than the security of the web-based data centers.
Violation of the data center will put sensitive data at risk. Thus, every data center should be protected from physical threats. Recommended safety measures include:
Only authorized employees should have access to the data center, and the number of authorized employees should be reduced to a minimum.
The web is getting bigger by the day, so the demand for data centers is growing exponentially. Existing data centers will soon need to host more Internet forums, which means taking up more servers and other resources. Therefore, the design and construction of a data center should account for flexibility and flexibility – all data centers should be ready to accept improvements whenever needed.
The data center is also looking for a suitable outdoor location, so the location should be close to perfect. There are several factors to consider when choosing a suitable location. Check out the following features in your list when checking for locations that may be suitable:
Other factors include regional usage, infrastructure development, transportation, and anything else that can affect data centers.
Currently, SDWAN technology is becoming popular and becoming a trend of a new era. This technology makes life easier and is ready for use by all stakeholders. In traditional data center technology, MPLS is used to connect remote branch offices to a centralized data center, and all communications are via MPLS to the data center. For example, if someone has email or ERP, the communication is done over a global network using MPLS technology. But we are talking about the one used in 2003. For now, in 2022, SDWAN makes life easier as everything will happen using a cloud like AWS or Azure. Traditional WAN architectures have been limited to enterprises, branch offices, and data centers. As soon as organizations adopt cloud-based applications in the form of SaaS and IaaS, WAN architectures will see an explosion of globally distributed traffic access applications.
These changes have a huge impact on IT. SaaS application performance issues can reduce employee productivity. Global network costs can increase due to inefficient use of dedicated and redundant channels. IT departments struggle every day to connect different types of users with different types of devices to different cloud environments. This helps remote branches and can receive data anytime, anywhere. This will be helpful for SaaS applications like Office 365 that they use frequently, and will help users get and use information whenever they want to access it. Data centers are now using SDWAN technology. In general, solutions are expensive and not everyone can afford, so it costs a lot of money and budget. These high-tech companies are definitely moving to SDWAN to keep evolving the technology and taking full advantage of it
In 1965, Gordon Moore observed that the number of transistors in a dense integrated circuit (IC) doubles every two years, which was later termed as Moore’s law, a self-fulfilling prophecy with uncanny accuracy. Today, experts believe that Moore’s law is reaching its physical limits while some say it’s already dead.
For the last 50 years, Moore’s law has fueled the development of powerful computer chips, resulting in more data storage and greater processing capacity, eventually leading to rapid digital expansion. Today, an estimated 7.2 million [1] modern data centers store 1327 exabytes [2] of data, with the US leading with 2751 [3] data centers.
Data centers have already pushed Moore’s law to extreme limits, with newer chip development gradually slowing down in the last few years. Traditionally, chip manufacturers would introduce lower-cost faster-performing chips every couple of years. Not anymore. Now, major data center market stakeholders invest more in innovative techniques to lower the overall cost of running data centers while improving data storage capacity to meet users’ demands.
In 2021, Gartner projected [4] end-user spending of $200 billion on global data center infrastructure, an increase of 6% from 2020. The increasing demand for data centers can be attributed to many growth drivers, mainly due to the explosive growth of data in every industry. In fact, IDC predicts [5] global data creation, consumption, and storage to reach 180 zettabytes by 2025, compared to 70 zettabytes in 2021. Some main growth drivers for the data center market include:
In this article, we’ll cover all aspects of data centers in detail. We’ll touch upon the history of data centers. We’ll delineate major data center components and discuss various benefits of data centers, key market players, data center rating systems, and future trends. In the end, we’ll briefly discuss the growing need for building more data center infrastructure in the Africa region.
Data centers have evolved over the course of the last 60 years. Dating back to the 1940s, ENIAC (Electronic Numerical Integrator and Computer) is considered the first vacuum tube-powered data center in the world. Designed by US Army during World War II, ENIAC’s primary objective was to assist in military and intelligence operations.
In the 1960s, computer technology started becoming more sophisticated. IBM launched the first commercial-purpose transistorized data center, TRADIC (TRAnsistorized DIgital Computer), which eventually helped NASA during their Apollo moon-landing missions.
In 1971, Intel launched the first-ever programmable microprocessor named Intel 4004 with 2300 transistors, which served as a building block for many electronic devices. In 1973, Xerox Alto was launched as the first personal computer with a user interface, ethernet networking, and large internal memory. In 1977, ARCnet was introduced, which facilitated LAN with data rates of 2.5 Mbps. In 1978, SunGard developed a commercial disaster recovery system which later paved the way for modern Disaster Recovery as a Service (DRaaS) methodology.
In the 1980s, Sun Microsystems along with other organizations a
Let’s formally define data centers and discuss various deployment architectures.
A data center is a centralized facility with powerful enterprise-grade computers and servers that store, manage, and disseminate data and critical software applications globally. Data centers contain racks of servers holding storage and processing resources connected via routers, cables, firewalls, and switches, along with a robust networking system that allows data center resources to communicate internally and make them accessible worldwide.
Data centers use advanced storage, compute, and networking hardware to provide uninterrupted services. Modern data centers use resource virtualization to enable scalable cloud computing. Business applications deployed on cloud-enabled data centers are fast, resilient, and secure.

Cloud data centers offer two kinds of cloud environments for serving software and hardware resources, i.e., single-tenet cloud architecture and multi-tenet cloud architecture.
In single-tenet cloud environments, business data and applications are deployed on a separate server instance, only visible to the client who purchased the underlying cloud infrastructure. In multi-tenet cloud environments, various customers have shared access to software and hardware resources. However, data centers ensure data privacy for each client individually.
A real-world analogy of single tenancy is where a tenant rents the whole apartment without sharing it with other tenets. While in multi-tenancy, multiple tenants rent different rooms within a single apartment where each tenant has a key to access their room.
Organizations can choose any model as per their requirements. Large-scale businesses often prefer single-tenancy to ensure enterprise-grade security, strong governance control, high performance, and high disaster recoverability. A trade-off for single-tenet architecture is paying high costs for owning and maintaining the complete cloud infrastructure.
On the other hand, startups and small businesses prefer multi-tenancy as it offers lower maintenance costs while mildly compromising governance control and security.
Another essential aspect of cloud data center architectures is managing application and data load. Data centers offer two deployment architectures for load balancing, i.e., clustered and non-clustered data centers.
Non-clustered data centers are similar to on-premise servers with additional security and cloud-enabled features. Organizations that prefer to keep their existing application infrastructures intact often choose non-clustered environments. On-premise to cloud migration follows a simpler deployment topology, but the application server presents a single point of failure. Non-clustered data center deployment does not ensure high availability or robust disaster recovery.
Clustered data center deployment offers load balancing capabilities to support high availability and disaster recovery for mission-critical applications. Clustering uses additional infrastructure to deploy multiple nodes of servers. Critical applications run on these nodes, managed by a load balancer that directs incoming traffic and distributes processing tasks efficiently to ensure application reliability and uptime. Backup nodes are activated immediately to minimize downtime in case of any failure.
Organizations can prefer any deployment architecture as per their requirements. In terms of cost, clustered deployment strategy is more expensive than its non-clustered counterpart since it requires additional cloud infrastructure to support scalability, which takes more time and governance effort.
Data centers are remarkable feats of modern architecture and engineering. In the last 20 years, data center service providers have brought considerable innovation in various data center design components. As a result, data centers are faster and more robust than ever before. Let’s discuss some major data center components below.
Racks are the building blocks of a data center, organized into rows. Generally, 19-inch standardized racks are used in enterprise data centers, but they can be customized according to the available floor space and design. Racks are placed strategically to allow maximum ventilation.
Racks contain electronic devices such as hard drives, servers, and networking equipment. Racks are placed on raised flooring which is covered with removable tiles. Different cables are passed underneath these raised floors that ensure overall data center connectivity. Data centers must have wide floor space to accommodate more racks and cabinets in the future.
Continuous power supply is the holy grail of data centers. Electricity powers hard drives, servers, networking infrastructure, and other electronic components. Each electronic device generates heat which increases the temperature inside the data centers. Proper ventilation and continuous air conditioning also consume a lot of power.
In case of primary power failure, data centers must employ redundant power supplies, including backup generators and UPS (Uninterruptible Power Supply), to maximize data center uptime. Enterprise data centers also use in-house green energy sources to meet their electricity demands.
Cables connect servers and networking equipment to create an effective data center communication infrastructure that serves mission-critical business applications. However, data center cable management requires specialized skills. Without prior consideration of floor design, proper cable management would be impossible. Complete cabling infrastructure must be documented to ease future maintenance and troubleshooting.
Storage is one of the three most fundamental functions of a data center, along with compute power and networking. Data centers contain tons of modern storage devices (hard drives) to store critical business data. Drives are duplicated over multiple racks to ensure fault tolerance.
Cloud-enabled data centers offer Storage as a Service (STaaS) which businesses can request on-demand to store various digital assets. Data center manufacturers install specialized hard drives that ensure faster data loading time.
Compute refers to the computer processing power required to execute software applications in the data center. Data centers use fast processing chips (often specialized and proprietary) with scalable workloads to ensure maximum application runtime. Data centers must be powerful enough to process enterprise application traffic which can be thousands of requests per second.
Data center networking is a constellation of routers, switches, cables, and load balancers. A robust networking infrastructure ensures resource communication inside the data center. It enables data center virtualization, which allows the use of data center resources globally. Networking also allows automatic resource provisioning and de-provisioning, load balancing, and resource duplication across various availability regions to avoid drastic failures.
Data centers use megawatts of electricity to run electronic equipment, which heats up quickly. Without proper cooling equipment, devices can malfunction, resulting in performance degradation and increasing management costs. To naturally maintain temperature, data center manufacturers build data centers in colder regions. (discussed in the next section)
Data centers employ various cooling mechanisms to reduce the overall heat produced from devices, resulting in lowering electricity costs. To reduce heat, some data center manufacturers use water and evaporative cooling with better airflow management. Underwater cooling systems are also installed under the raised flooring on which racks and cabinets are placed.
Temperature management has been a long-standing pain point for building highly operational data centers. After years of hazardous experiences, data center facilities now install various fire protection and safety protocols. Automatic temperature monitoring and management, smoke detectors, fire alarms, and fire sprinklers are some of these safety protocols.
Besides these critical components, the operational success of a data center relies on choosing an appropriate physical location for construction.
Building state-of-the-art data center facilities start with choosing a suitable physical location. It plays a crucial role in maximizing the return on investment for establishing a robust data center facility with a lifecycle spanning 10 to 15 years. Many geographical, economic, political, and social factors can influence the data center site selection criteria, including:
Data centers are multi-billion dollar facilities housing vast amounts of invaluable data. In addition to many software security layers and firewalls, data centers must have a multi-tiered physical security system to save people, property, and expensive electronic assets from theft, burglary, terrorism, and natural disaster.
Physical security features are incorporated into the engineering and design of data center facilities. While data center service providers can have different taxonomy for physical security, a general multi-tiered physical security system for any modern data center is as follows:
The first security layer requires securing the data center perimeter with gates, barriers, fences, CCTV cameras, and guards to avoid any unauthorized entry. Guards can be stationed on watchtowers, main entrances and exits, and using on-ground vehicle patrols to identify irregular activities.
The second layer of data center physical security contains identification cards and biometric scans. Only registered personnel should be allowed to enter the data center facility after ID verification. Cards and biometric scans can categorize individuals as per their clearance level. For example, a customer care representative should be prohibited from entering the data center floor or restricted rooms.
Data centers must have a separate entrance for loading and unloading supplies like external equipment and accessories. No unregistered personnel must be allowed to enter the vicinity without prior approval.
The third tier of physical security is a centralized security hub that monitors all activities inside or outside the data center. A central hub is like the brain on the data center facility. It runs 24/7 throughout the year to proactively assess threats and ensure safeguards. High-definition cameras can identify potential threats and the central hub can notify security personnel on the ground to avert any unfavorable conditions.
Only individuals cleared by the first three tiers should enter the data center floor. The data center floor or region contains racks of servers aligned in rows. The server racks can be further restricted using electronic locks or biometric access to avoid data breaches. As we move up the physical security layers, the number of authorized individuals would significantly decrease.
The fifth layer is the most sensitive physical security level, where hard drives and data-sensitive equipment are maintained. Usually, a top-secret room is built where existing hard drives are brought for repair, recovery, or erasure. Data centers ensure that no data can be taken outside this specified region, let alone the facility. Only the most trusted individuals are allowed inside.
As companies expand their IT applications, data centers become more vital to technological maintenance and sustainable growth. Let’s discuss some benefits of data centers below.
Data centers offer a continuous power supply that can keep your IT application running 24/7, 365 days. In case of any device failure, data centers offer redundancy in IT equipment along with backup generators.
However, depending on the data center Tier rating (discussed below), the facility can face maintenance downtime for a few minutes to a couple of hours annually. Before any scheduled downtime, the data center customers are made aware of the possible downtime, which allows them to mitigate any loss beforehand.
Data storage is the most significant operation offered by data centers. It includes collection, storage, retrieval, governance, distribution, and backup services. Organizations can choose data services according to their business requirements.
Performance includes compute power and data processing. Data centers contain specialized memory management and processing chips tailor-made to fulfill the modern data and networking requirements. The compute power can scale up or down as per the organization’s requirements.
Organizations can reduce their overall IT management efforts by outsourcing the governance of data and software applications to the data centers. Data centers have high-skilled employees responsible for keeping the system running throughout the year.
Data is the most critical asset for any organization. Data center facilities offer redundancy in storage where data can be backed up safely and retrieved in case of any failures. With virtualization, organizations can set up redundant instances to back up their entire IT environments that can be used as a replacement in case of a fault within a few seconds, reducing any revenue loss.
Data centers have multi-tiered physical and virtual security. High-end data center facilities are like data fortresses. No one can enter the building without authorization and clearance. Also, data and IT applications are often encrypted, significantly reducing the chances of data theft.
Data centers reduce the overall operational costs of their customers. They offer specialized power sources, cooling mechanisms, efficient storage, and optimized memory, all of which lower the cost of running IT applications in the data center. One such example is the AWS Graviton2 CPU [8] that offers up to 40% more application performance while reducing the price by 20%.
Selecting a data center that aligns with business requirements is critical for success. Uptime Tier Classification System [9] certifies the performance of data centers on their topology and operational sustainability by classifying them into one of four Tiers, i.e., Tier 1, Tier 2, Tier 3, and Tier 4.
Topology focuses on the data center infrastructure along with other capabilities like maintenance, power, cooling, and fault tolerance. At the same time, operational sustainability depends on the data center management that allows it to continue meeting business requirements in the long run. The Tier classification system is progressive, starting with Tier 1 at a basic capacity level and going up to Tier 4, indicating advanced data center capabilities.
Tier 1 represents the most affordable class of data centers, preferred by small companies and start-ups, without any complex or large-scale business demands.
Tier-1 data center promises an uptime of 99.671% annually, which indicates a downtime of fewer than 28.8 hours per year. It has an uninterruptible power supply with a dedicated cooling system that can keep the data center running 24 hours a day. However, the data center could face power outages or maintenance downtime due to the lack of redundant power sources.
Tier 2 data centers are more resilient to power outages due to the availability of backup power and cooling supplies like generators, energy storage, chillers, heat rejection equipment, fuel cells, and more.
In Tier 2, customers can have an uptime of 99.741%, which indicates a downtime of up to 22 hours annually. Such data centers are suitable for Small and Medium-sized Businesses (SMBs) as they provide a good cost-to-performance ratio.
Tier 3 offers more redundancy for various data center components with an uptime of 99.982%, bringing annual downtime to less than 1.6 hours. Tier 3 requires no maintenance shut down as the power supplies are redundant.
Each data center component can be maintained or repaired without facing any disruptions in IT operations. Tier 3 offers cost affordability with high performance for larger businesses.
With an uptime of 99.995%, Tier 4 offers the most fault-tolerant and advanced data center facilities that can process high volumes of data and accommodate large applications for enterprises, conglomerates, and government entities. All data center IT devices offer redundancy and alternate power distribution paths that bring the annual downtime to 26.3 minutes.
The Tier classification system does not indicate that a Tier 4 data center is better than Tier 1. It represents the difference in their abilities to meet business requirements, enabling organizations to make better decisions while selecting a data center.
Migrating from on-premise to an external data center requires extensive planning and decision-making due to the complexity of the task. With varying business requirements and goals, each migration is different from the other. However, a general guideline for enterprise data center migration is given below:
Hire or appoint specialized individuals to oversee the data center migration process. Though every organization has different staffing hierarchies, some following key roles are vital for the successful transition of a business from on-premise storage to an enterprise data center.
Depending on the scale of the project, organizations can have many other specialized roles to oversee each migration component, like network engineers, security experts, database administrators, and site reliability experts.
Conduct a complete audit of the existing server infrastructure and deployment environment. All functionalities are thoroughly tested to verify performance benchmarks and identify any deficiencies.
Compare the server capabilities of on-premise deployment and enterprise data center and observe how the application’s performance can be affected after migration. Identify all dependencies, third-party applications, and APIs linked to the existing environment.
After conducting a comprehensive audit, work on any system deficiencies to fine-tune the on-premise application and make it compatible with the data center deployment environment for a smooth transition.
Documentation is significant to track and record any software and hardware specifications. When the complete on-premise server environment is recorded along with any dependencies, potential modifications, and existing and potential errors, business stakeholders can better understand what to expect after migration.
Enterprise data centers offer various deployment architectures and environment configurations, including clustered, non-clustered, single-tenant multi-tenant, shared, public and private cloud, etc. Each architecture offers various pros and cons regarding performance, availability, and disaster recovery. Prepare a complete purchase plan that aligns with the business’s operational and financial requirements before migration.
Finally, it is time to deploy the business application to the data center environment. First, set up the hardware (virtual) components like nodes, clusters, and load balancers. Then, install the application along with data and other dependencies and ensure that each business function is working as expected. Testing, monitoring, and maintenance are conducted rigorously before launching the application for end-users.
Data centers require multi-billion dollar investments, which is why only big tech companies like Microsoft, Amazon, Google, and a few others offer data center services. In fact, Microsoft, Google, and Amazon account for over half [10] of today’s 600 hyperscale data centers. However, many other small to large-scale data center manufacturers and service providers offer data center services of different tiers with varying business use cases.
Many data centers offer overlapping functionalities and architectures. Based on general configurations, the following types of data centers are available in the market.
The data center market is evolving rapidly with chip improvements, better cooling systems, optimized storage and networking infrastructure along with added security layers to meet the demands of the ever-changing technological ecosystem. Due to the emergence of technologies like automation, blockchain, IoT, 5G connectivity, and edge computing, data centers in the next five years would ensure more performance reliability and robustness. Let’s discuss some future technological trends in the data center market.
Cloud computing offers scalability, which is a critical business requirement for digital transformation. As worldwide digitalization accelerates, more businesses are turning towards cloud computing, increasing the demand for hyperscale data centers.
Hyperscale data centers (HDC) consist of thousands of server cabinets connected with high-speed networking infrastructure that supports big data and cloud computing operations. International Data Corporation (IDC) defines a hyperscale data center as a facility with more than 5,000 servers spread across more than 10,000 square feet.
Hyperscale data centers are significantly larger than enterprise data centers, with more storage, processing, and networking power. They are mostly built and managed by technology giants who have enough revenue to support data center operations on a large scale.
Automation and robotics is another driving factor in the changing data center market trends. Manufacturers are looking to reduce the operational cost of data centers by decreasing human intervention, resulting in innovative solutions that can automate manual tasks. By 2025, Gartner predicts that half of the worldwide cloud data centers will deploy AI-enabled robots [11].
Automation is also leading digital transformation globally. Many businesses are implementing data-intensive automated processes to increase the productivity of their product or application features. All the data generated by these applications eventually land in the data center.
High-speed internet connectivity has increased the development of IoT and edge computing. Billions of mobile and smart devices generate massive amounts of data and network requests every day. Data center manufacturers are improving their facilities to accommodate this inflow of traffic. Many new edge data center facilities are being built strategically in regions where smart devices are used more to offer high connectivity and response.
Data centers use 1-2% of global electricity each year to run huge volumes of IT devices that require a dedicated cooling mechanism. Manufacturers spend millions of dollars on optimized power supplies and cooling systems, which increase the overall operational costs of data centers.
To bring down energy costs, data center manufacturers are using renewable energy to build green data centers. They are also experimenting with innovative cooling mechanisms, including liquid cooling and underwater data centers. The future of data centers is green, renewable, and carbon-free.
Though the concept of data center colocation has been around for a while, but due to growing business demand, many companies are opting to set up their own data centers instead of limited on-premise server deployment, increasing the demand for colocation data centers.
Data center as a Service (DaaS) is another emerging trend similar to colocation. In colocation data centers, companies can choose to buy individual IT infrastructures like storage or memory. However, in DaaS, companies can purchase fully managed data center solutions, also referred to as the democratization of data centers.
The continent of Africa is technologically landlocked. However, efforts have been made to bring technology to the vast population of Africa recently. Many organizations are interested in constructing their data centers in the African region. In fact, in 2021, the data center market of the Middle East and Africa recorded investments [12] of $6.55 billion and forecasts investments of $12.19 billion by 2027.
Africa’s mobile userbase is increasing rapidly and requires more data centers to optimize intra-African network traffic and reduce latency. Reports [13] suggest that Africa requires 1000MW & 700 data center facilities, preferably outside of countries like South Africa, Egypt, Nigeria, Morocco, and Kenya, as they already hold two-thirds of the continent’s data center capacity.
Recently, Amazon Web Services (AWS) has launched [14] a cloud region in Cape Town, making it the company’s first African region. Customers can now store data and run applications locally within South Africa at low latency.
Some other companies have also started investing in data center infrastructure within Africa. Africa Data Centres plans to build 10 data centers and has announced [15] an investment of $500 million. Similarly, Huawei [16] and Oracle [17] plan to start data center operations across Africa.
EPCM Holdings is a global leader in infrastructure engineering, design, procurement, construction, and commissioning in various sectors. Contact us today to discuss how we can help in setting up enterprise-scale data center facilities.
[1] https://www.statista.com/statistics/500458/worldwide-datacenter-and-it-sites/
[2] https://www.statista.com/statistics/638613/worldwide-data-center-storage-used-capacity/
[3] https://www.statista.com/statistics/1228433/data-centers-worldwide-by-country/
[4] https://www.gartner.com/en/newsroom/press-releases/2020-10-07-gartner-says-worldwide-data-center-infrastructure-spending-to-grow-6-percent-in-2021
[5] https://www.statista.com/statistics/871513/worldwide-data-created/
[6] https://www.nasdaq.com/articles/the-small-business-economy-is-set-to-soar-in-2022
[7] https://www.mordorintelligence.com/industry-reports/over-the-top-market
[8] https://docs.aws.amazon.com/whitepapers/latest/aws-graviton2-for-isv/aws-graviton2-for-isv.pdf
[9] https://uptimeinstitute.com/tiers
[11] https://www.gartner.com/en/newsroom/press-releases/2021-11-01-gartner-predicts-half-of-cloud-data-centers-will-deploy-robots-with-ai-capabilties-by-2025
[12] https://www.researchandmarkets.com/reports/5530306/middle-east-and-africa-data-center-market
[14] https://www.datacenterdynamics.com/en/news/aws-launches-south-african-region/
[16] https://www.africanews.com/2021/12/15/huawei-invests-in-data-centres-in-africa/
A chemical reactor is a closed container where a chemical reaction is carried out. Process designers have to make sure that the reaction progresses as efficiently as possible towards the intended product, resulting in the best yield while needing the least money to buy and operate. Energy intake, energy disposal, cost of raw materials, labor, and other charges are all part of regular operational expenses.
The reactant and products are usually fluids (gases or liquids). Continuous reactors are usually operated at a constant state, whereas batch reactors are operated in a transient state. A reactor is transient when it is turned on for the first time or after a shutdown, and critical process variables vary over time.
Three idealized models are used to determine the basic process variables of diverse chemical reactors:
Many reactors in the process industry can be characterized as combining these fundamental types. Main process variables associated with the reactors include:
A packed bed is frequently used in tubular reactors. The channel or tube comprises particles, generally solid catalysts in this scenario. The reactants are pushed through the catalyst bed in liquid or gas form. A fluidized bed can also be used as a chemical reactor.
Chemical processes in a reactor can be exothermic (gives out heat) or endothermic (absorbs heat). Tubular reactors can be built as heat exchangers if the reaction is highly exothermic.
A batch reactor is a non-continuous form of reactor consisting of a closed vessel wherein reactions occur. Initially, all of the reactants are added to the reactor simultaneously. Batch reactors usually have an agitator that mixes the reactants thoroughly to execute the reaction and synthesize the product effectively.

Exothermic reactions are typically treated using cooling coils in batch reactors. The batch reactor is a non-stable, transitory reactor. It means that the quantity of conversion in the reactor varies with time. The batch reactor nature remains quite uniform because of the agitation. It implies that the degree of conversion is unaffected by the placement of the reactor. The extent of reaction in any part of the reactor remains equal at all times.
The versatility of a batch reactor is its most significant advantage. A single batch reactor can deliver different products. Batch reactors are very effective when a reaction produces a large number of products.
A batch reactor has the drawback of requiring a lot of effort to charge reactants, release products, and clean the reactor for the next batch.
A continuous stirred tank reactor (CSTR) is also known as a mixed flow reactor. In this reactor, the reaction takes place in a closed tank. An agitator is also included in the tank to make sure that the reactants are well mixed.

The reactants enter the reactor at a constant flow rate, react within the vessel for a time indicated by the space-time of the reactor, and then produce products. All products flow out of the reactor at the same time. The time it takes to execute one reactor volume is equivalent to one space-time.
The agitator maintains a constant concentration throughout the reactor. It also implies that the amount of conversion is unaffected by position in the reactor. The volume of the reactor determines the conversion extent.
The main advantage of employing a CSTR in the industry is generating a massive product volume. It is a continuous steady-state reactor that can run for an extended length of time.
CSTRs are unsuitable for reactions with extremely slow kinetics that often need a very large volume reactor. The operation costs of the reactor may render it unfeasible. In this situation, a batch reactor is employed.
A plug flow reactor (PFR) is also known as a continuous tubular reactor (CTR). The plug flow reactor model describes chemical reactions in cylindrical, continuous flows.

The benefit of PFR over CSTR is that the PFR has a lower volume than a CSTR for the same space-time and conversion level. It indicates that the reactor requires less space and that the amount of conversion is higher in PFR than in CSTR for the same reactor volume. The PFR is frequently used to determine the kinetics of the gas-phase catalytic process.
Performing an exothermic reaction in a PFR is difficult to control because of the wide range of temperature profiles. Operational and maintenance expenditures for a PFR are more expensive than the CSTR, which is less expensive.
A semi-flow reactor is a batch reactor modification. It is a closed vessel with an agitator to mix the reactants. One reactant is completely charged in the reactor initially, while the other is charged after regular time intervals. So, one chemical reactant is filled into the reactor, and the other chemical is added slowly (e.g., to prevent side reactions), or a product formed by a phase transition is continuously separated, such as gas formation during the reaction, precipitation of solids, or formation of hydrophobic product.

Using a semi-batch reactor while executing many reactions provides better control over the yield and product selectivity. This reactor comes in helpful when executing an exothermic reaction since the continuous flow of the other reagent may be regulated to control the exothermic reaction better.
Clean reactors, clean blades, and more labor are all needed to charge and discharge a reactor properly.
Catalytic reactors are frequently deployed as plug flow reactors; however, their calculations demand a more complicated technique. The amount of catalyst that the reagents come into contact with and the concentration of the reactants determine the catalytic reaction rate. A catalytic reaction pathway frequently happens with chemically bound intermediates in numerous phases. The kinetics may be affected by the chemical bonding to the catalyst, which is itself a chemical process. Catalytic processes commonly display so-called faked kinetics, in which the perceived kinetics vary from the true chemical kinetics due to physical transport factors.
Catalysts are deactivated by coking, poisoning, and sintering, especially in high-temperature petrochemical processes. There are vast process operations in industries where catalyst reactors are required to carry out sophisticated and complex reactions.
Some chemical reaction needs a specific catalyst to execute the reaction with suitable kinetics. Without a suitable catalyst, some reactions cannot proceed with economic kinetics. In general, the catalyst’s function is to provide an alternate, low-energy route for a process. Cracking of petroleum, hydrogenation of unsaturated hydrocarbons, ammonia synthesis, sulfuric acid synthesis, etc., are all examples of reactions that require some sort of catalyst.
Catalyst reactors require special maintenance, and it is difficult to control. A very controlled environment and experience are needed to carry out the specific reaction at an economical rate. There is also a chance of degradation of the expensive catalyst if the conditions are not optimized.
Countries have been negotiating how to combat climate change under the United Nations Framework Convention on Climate Change (UNFCCC) for decades. Multiple agreements have resulted from these negotiations, notably, the 2015 Paris Agreement, in which countries pledged to keep global warming below 1.5 degrees Celsius or “well below” 2 degrees above pre-industrial levels. Earth is on track for a 2.4°C global temperature increment above pre-industrial levels by 2100 if countries persist with the 2030 emissions reduction targets (in jargon, nationally determined contributions, NDCs) they submitted in Glasgow. This is bad news, as science has shown, mankind must limit global temperature increases below 1.5°C to avert the most severe impacts of climate change.
Taking into account the long run net-zero pledges that have been made by many countries a short while ago by India, would limit the rise to 1.8°C in 2100 after some limited overshoot. However, this rate should be taken sceptically, as most of these pledges are currently not backed up by real action or planning.
Given this context, the first climate priority for next years should be to reduce the global emissions gap by ensuring that NDCs are enhanced to a level compatible with the 1.5°C track. The Glasgow Climate Pact agreed by the 197 countries at COP26 provides a solid foundation for this.
In accordance with the Paris Agreement, countries are required to recap their nationally determined contributions (NDCs), i.e. their post-2020 climate actions, that should also uphold “the principle of equity and common but differentiated responsibilities and respective capabilities, in light of different national circumstances”. According to a recent UNFCCC estimate, existing NDCs filed by 2020 would result in global emissions being only 0.5 per cent lower in 2030 than in 2010, compared to the 45 per cent reduction required to keep global warming below 1.5°C [1].
As a result, immediate and long-term strategies to achieve the Paris Agreement’s goals are urgently required. Despite a brief decline in carbon emissions in 2020 due to the COVID-19 outbreak, global greenhouse gas (GHG) emissions increased for the third year in a row in 2019, despite the fact that they will need to fall drastically – to zero by mid-century – to satisfy the Paris Agreement’s targets.
Currently, fossil fuels account for the majority of these emissions (more than 75%). Hence, achieving net-zero emissions necessitates significant reductions in fossil fuel use and supply. According to a determination in the Production Gap Report [2] based on mitigation scenarios compiled by the Intergovernmental Panel on Climate Change, annual average decline rates of around 3%, 4%, and 11% in global gas, oil, and coal production, respectively, would be consistent with limiting warming to below 1.5°C between now and 2030. If carbon dioxide removal solutions are not developed at scale, these rates will need to be considerably quicker.

Figure 1. CO2 emissions from developed global fossil fuel reserves, compared to carbon budgets within range of Paris Goals. Source: http://priceofoil.org/content/uploads/2020/09/OCI-Big-Oil-Reality-Check-vF.pdf
Despite this clear implication for a necessary wind-down of fossil fuels to satisfy climate targets, nations have yet to begin serious discussions on who will generate those declining amounts of fossil fuels. The UNFCCC has not explicitly addressed fossil fuels for a variety of reasons. Nonetheless, discussions on prospective “supply side” agreements on fossil fuels and climate change are beginning to emerge, either as part of the UNFCCC or separately. Several countries, notably Denmark, France, and New Zealand, have started to take steps to phase down their oil and gas production. President Joe Biden of the United States has halted new oil and gas leasing on federal lands and seas, while Vice President Kamala Harris has proposed a “first-ever worldwide discussion of the cooperatively managed decrease of fossil fuel output” [3].
The prospect of a supply-side agreement raises a number of key questions, including how countries would self-organise, what precepts they might use to share the task of cutting down coal, oil, and gas production, and whether they would decidedly seek to do so in a way that is consistent with the Paris Agreement’s ambitions.
The goal of this article is to contribute to this emerging discussion on why countries might work together to rethink oil and gas extraction. This is driven by the importance of regulating fossil fuel supply in effective global climate policy, as well as the equitable implications of a rapid transition away from the commodities – coal, oil, and gas – on which some communities (and countries) rely for their survival. Indeed, when evaluating the supply of fossil fuels as a matter of equality, we are building on a rapidly growing debate on equity considerations in the transition away from fossil fuel extraction.
The COP26 UN Climate Change Conference, hosted by the UK in partnership with Italy, took place from October 31st to November 12th. It was deemed to serve as the platform for the international community to reach an agreement and accelerate climate action in relation to the 2015 Paris Agreement. Citizens, companies, governments, and investors, all play a key role in achieving this.
Rapid decarbonisation and the divorce of economic growth from resource extraction are undoubtedly the only ways to ensure humankind’s sustainable and fair future. Still, have we delayed action for too long? Even if the world’s nations could still surprise and submit ambitious NDCs based on green stimulus packages derived from COP26, the current prognosis is not favourable. Negative-emissions technologies (NETs) could still be needed to properly chase down the high-reaching carbon targets necessary for warding off dangerous climate change side effects whether we like it or not.
The 26th Conference of the Parties to the United Nations Framework Convention on Climate Change (UNFCCC), held for the first time in Glasgow, Scotland, spanned the fortnight October 31st through November 13th. By some legitimate expectations, the Conference can only be deemed a failure. And yet, in fuller consideration, the failure was not wholly abject.
First, from the viewpoint of the climate system, most emitting nations failed to develop or expand their commitment to timely decarbonisation of the economy and atmosphere. Second, the Conference failed because, as before, wealthy nations offered no resources to help hard-hit least-developed countries to deal directly with climate-associated losses and damages.
Still, COP26 secured some genuine progress, particularly as it expressly targeted fossil fuels for the first time and clarified several important road rules from now on. COP26 featured conflicted pronouncements regarding coal that ended in “efforts towards the phasedown of unabated coal power.” The final Glasgow Climate Pact called to spur technologies and policies aimed at “transition towards low-emission energy systems,” including a “phase-out of inefficient fossil fuel subsidies.”
The industry is facing increasing demands to elucidate the implications of energy transitions for their business models and operations and break down the contributions they can make to cutting greenhouse gas emissions and achieving the goals of the Paris Agreement.
Oil and gas faces the strategic challenge of harmonising short-term returns with its long-term licence to operate. Societies are requesting both energy services and carbon reductions at the same time. Oil and gas firms have excelled at supplying the fuels that are the foundation of today’s energy system; the question now is whether they can also assist in the delivery of climate solutions. This might be conceivable provided the oil and gas industry takes the required measures.

Figure 2. Gryphon FPSO (Floating Production Storage and Offloading) facility surrounded by windmills in the North Sea. Source: “Gryphon FPSO” by Nik Morris (van Leiden) under >a href=”https://creativecommons.org/licenses/by-nc-sa/2.0/?ref=openverse&atype=rich”>CC BY-NC-SA 2.0 license.
As a result, it opens the path for the oil and gas business to join the “grand alliance” that the IEA thinks necessary to combat climate change, which some corporations are already doing. This initiative would be immensely enhanced if more companies joined in unreservedly. The expenditures of creating low-carbon technology are an investment in a company’s long-term potential to succeed.
No oil and gas company will remain untouched by clean energy transitions, so every element of the industry needs to reexamine how to respond. The O&G landscape is diverse, and there is no single strategic game plan that will make sense for all. The spotlight often focuses on “the Majors”: seven large integrated companies that extensively influence industry practices and business direction. But O&G is much larger: the Majors account for 15% of production, 12% of oil and gas reserves, and 10% of estimated emissions from industry operations. National oil companies (NOCs) – fully or majority controlled by federal governments – account well on top of half of global production and an even bigger share of reserves. There are some high-performing NOCs, but many are poorly resilient to changes in global energy dynamics [4].
To date, investment by oil and gas corporations outside their core business areas has been less than 1% of total capital expenditure, and there are few signs of a major change in company investment spending for the moment. For those companies looking to branch out their energy operations, redeploying financial assets towards low-carbon businesses demands attractive return opportunities in the new markets as well as new capabilities within the companies. Leading individual businesses currently spend roughly 5% of their revenue on initiatives outside of core oil and gas supply, with solar PV and wind power receiving the most funding. Some oil and gas firms have also expanded into new industries by purchasing non-core businesses, such as energy distribution, electric car charging, and batteries while increasing their R&D efforts. To speed energy transitions, a significantly larger shift in total capital allocation would be necessary.
But the core question, against a scene of rising GHG emissions, is rather simple: should today’s O&G companies be considered only as part of the crisis, or could they also be crucial in solving it?
This section does not aim to provide categorical answers, not least because of the wide diversity of oil and gas companies and their strategies around the world. It does intend to map out the risks facing different members of the industry, as well as the range of options and responses.
The situation becomes interesting on the following graph from the International Energy Agency showing the contribution in Scope 1 and Scope 3 emission by the various segments of the oil and gas industry. Scope 1 is, of course, the emission generated by one’s own production as CO2 by the direct use of the hydrocarbon. Although the awareness tends to be on the majors, it is easier to see that most of the emissions have come from the NOCs themselves.

Figure 3. Property of oil and gas reserves, production and upstream investment by company type, 2018. Source: https://www.iea.org/reports/the-oil-and-gas-industry-in-energy-transitions
Looking at the majors, especially the European, we can see that “Net Zero” and the “Energy Transition” are on the very first page of most companies’ websites and public reports; these are becoming more serious and stronger commitments and objectives. Repsol and BP recently declarer net zero ambitions by 2050, as well as Shell who is selecting an uptake to upgrade their already existing objective to net zero in2050. So the majors are not only justifying its renewable generation but, of course, also keeping their production of oil and gas, making sure that that goes to a net-zero path at least on Scope 1 emission. That would be an interesting path to follow because that means a big change for the industry.
When it comes to the independents, the situation is a bit different; they are mainly financed by private equity, which means that return on investment is the key message on the web pages and finding something about climate changes on their disclosures is a bit harder. That being said, we want to remember that you do not go to these companies as a consumer, so communication is mainly targeted to their investors. Finally, when we look at the national companies, the point is predominantly about energy security for the country, exporting the maximum of national resources, and making sure that societies can be fueled.
Denmark, Costa Rica, Ireland, and France are among the countries pledging to end oil and gas production within their borders, but big producers decline to join [5]. Portugal, California, and New Zealand withdrew from the pledge but agreed to take “major tangible efforts” to curb fossil fuel production. Italy, the EU’s second-largest oil producer, made a less ambitious vow, saying that future oil and gas development will be in line with the 2015 Paris Agreement.
The novel Beyond Oil and Gas Alliance (BOGA) [6] was hailed as crucial by campaigners who have been urging for a global treaty on stopping fossil fuel extraction, designed upon nuclear weapons proliferation treaties. Analogous international coalitions have already been enacted against coal, but not yet on oil and gas. However, the alliance, launched at the COP26 summit in Glasgow last November, lacks any meaningful O&G producers promising to end extraction. The core affiliates to BOGA are Costa Rica, Denmark, Ireland, Sweden, France, Greenland, Wales and the Canadian province of Quebec. But Wales does not have the ability to issue oil and gas licences; that power lies with the UK government. New Zealand, Portugal, and California are “associate” members of BOGA, while Italy is deemed an “ally” of the coalition.
Activists and the climate science community hope BOGA settles in and reinvents what it means to be a ‘climate leader’. Countries, subnational jurisdictions, and companies committing to net zero emissions by 2050, while refusing to mollify the expansion of fossil fuel yields, should not claim this title — which could be reserved for those equitably tackling both the demand and supply of fossil fuels [7]. To be successful, BOGA may need to listen closely to some of the climate action leaders’ advice:
The creation of the Beyond Oil and Gas Alliance is an important development and a welcome first step towards a global managed decline of fossil fuel production. UNFCCC urges more countries and subnational actors to join this initiative to create momentum to end oil and gas expansion and to align existing production with the 1.5ºC limit.
The Joint Glasgow Declaration came as a welcome surprise to all. It proved that growing tensions between the two nations need not impede progress on climate action and served as a reminder of the two US-China joint statements that provided an impetus to the Paris Agreement. The U.S.-China Joint Declaration on Enhancing Climate Action in the 2020s was announced on November 10th 2021.
The bilateral statement includes, among other things, an agreement between the two countries to “develop additional measures to enhance methane emission control, at both the national and sub-national levels.” The United States has announced the US Methane Emissions Reduction Action Plan, and China pledged they would proceed similarly. Although no explicit timescale for that plan was given, the Chinese Department of Climate Change said that in 2021-2025 the country would bring out an action plan on controlling the gas and develop a framework for hampering methane emissions from the oil and gas, coal and waste sectors.
Countries also recall “their respective commitments regarding the elimination of support for unabated international thermal coal power generation” and welcome the Glasgow Leaders’ Declaration on Forests and Land Use [8]. The first commitment aims to significantly reduce the cost of renewable energy throughout this decade and encourage its use worldwide. That aligns with China’s engagement to support green and low-carbon energy in developing nations and halt construction of coal power plants overseas. The latter aims to halt and reverse forest loss and land degradation by 2030 while promoting an inclusive rural shift. China is a leading importer of deforestation-risk commodities such as palm oil, soy, and timber products, so its signature is relevant and indicates a willingness to participate in the global governance of these issues.
The two countries intend to cooperate on policies that promote energy efficiency policies and standards to reduce electricity waste; support the effective integration of high shares of low-cost intermittent renewable energy; transmission schemes that encourage efficient balancing of electricity supply and demand across broad geographies; distributed generation programmes that encourage the integration of solar, storage, and other clean power solutions closer to electricity users. The United States has set a goal to reach 100% carbon pollution-free electricity by 2035whereas China will phase down coal consumption during the 15th Five Year Plan and make best efforts to accelerate this work [9].

Figure 4. China’s chief climate negotiator Xie Zhenhua said his country and the US had held more than 30 virtual meetings. Source: https://chinadialogue.net/en/climate/coal-1-5c-and-short-term-actions-china-at-cop26/
Recognising the critical role of methane emissions in rising temperatures, both governments believe that an enhanced effort to regulate and limit such emissions will be necessary for the 2020s. In September, the EU and US issued the Global Methane Pledge, promising to cut anthropogenic methane emissions by 30% on a 2020 baseline. At least another 108 countries signed up to that pledge during the Glasgow conference. Climate Action Tracker [10] estimates that it will avoid the equivalent of one-fifth of all nationally determined contributions (NDCs) so far claimed under the Paris Agreement; that is, 800 million tonnes of carbon emissions. However, China has not signed up for that pledge.
Nevertheless, the United States and China intend to convene a meeting in the first half of 2022 to focus on the specifics of reinforcing measurement and mitigation of methane, including through standards to scale down methane from the O&G and waste sectors, as well as incentives and programs to reduce methane from the agricultural sector.
It is also worth mentioning a declaration following the inaugural meeting of the International Aviation Climate Ambition Coalition at COP 26, through which Ministers and representatives from 23 countries agree that the International Civil Aviation Organization (ICAO) is the appropriate forum in which to address emissions from international aviation, and identify ways to collaborate through this council. In addition, they utter ways to ensure the effectiveness of the Carbon Offsetting and Reduction Scheme for International Aviation (CORSIA).
The meeting recognised aviation’s material contribution to global warming through its GHG emissions, along with its additional, but less well-defined, contribution linked with non-CO2 emissions. Parties conceded that despite the impact of COVID-19, the global aviation industry, the volume of cargo, and the number of air passengers is expected to increase immensely over the next three decades.
Participants also acknowledged the impact of COVID-19 on the international aviation sector and the need to expand initiatives that enable the flight industry to continue to build back better and grow in a sustainable manner. They emphasised that international action on tackling aviation emissions is essential given the transnational nature of the sector and that cooperation by states and aeronautics stakeholders is critical for reducing the sector’s share in climate change, including its risks and impacts.
Consequently, the International Civil Aviation Organization was deemed the appropriate forum to address emissions from international flights through a variety of measures to implement short-, medium- and long-term goals. These measures include the development of a universal sustainability framework to support the deployment of sustainable aviation fuel (SAF) and the CORSIA.
Parties committed to:
The declaration was signed by the ministers and representatives of the United States of America, Burkina Faso, Costa Rica, Denmark, France, Finland, Ireland, Italy, Japan, Kenya, Republic of Korea, Malta, Morocco, Netherlands, New Zealand, Norway, Spain, Sweden, Maldives, Turkey, Slovenia, Canada, and the United Kingdom [11].
There is much the industry could do right now to reduce the environmental footprint of its own operations. One of the industry’s biggest problems is uncertainty, but this is no reason for majors to “wait and see” as they examine their strategic choices. Attenuating emissions from core oil and gas practices should be a first-order priority for all, whatever the transition pathway.
There are numerous, cost-effective opportunities to bring down the emissions intensity of delivered fuels by tackling methane emissions, minimising flaring of associated gas and venting of CO2, and incorporating low-carbon electricity into new upstream and liquefied natural gas (LNG) projects. The process of bringing oil and gas out off the ground and to customers currently accounts for 15% of worldwide energy-related GHG emissions. The single most important and cost-effective option for the sector to bring these emissions is to reduce methane leakage into the atmosphere.

Figure 5. Changes in the average global carbon intensity of oil and natural gas operations in the Sustainable Development Scenario. Source: https://www.iea.org/reports/the-oil-and-gas-industry-in-energy-transitions
A shift from “oil and gas” to broader “energy” takes companies out of their comfort zone but spawns a new way to manage transition risks. Some large O&G companies are poised to convert to wide-ranging “energy” suppliers that work with various fuels, electricity and other power services to consumers. This entails moving into sectors, such as electricity, where there is already a large number of specialised actors and where the financials and scale of most low-carbon investment opportunities differ significantly from traditional oil and gas projects (except for offshore wind). Given that electricity has surpassed oil as the primary component in consumer energy spending in accelerated energy transitions, it offers long-term development prospects. It also paves the way to more significant and broader reductions in company emissions whilst relieving social pressures.
Without O&G, the transformation of the energy sector will be burdensome and more expensive. Oil and gas companies must explain how energy changes will affect their operations and business models, as well as the contributions they can make to speed up the pace of change. This process has begun, and company pledges to cut emissions (or emission intensities) are becoming more widespread.
However, the industry can go beyond to respond to the peril of climate change. Climate impacts will become more visible and relentless over the coming years, regardless of which pathway the world follows. This will increase the pressure on all elements of society to find solutions, those that cannot be uncovered within today’s oil and gas paradigm [12].
Furthermore, O&G will be critical for some central capital-intensive clean energy technologies to reach maturity. The capabilities and resources of the industry can play a decisive role in helping to tackle emissions from some of the hardest-to-abate economy stratum. This includes advancing carbon capture storage and utilisation (CCUS), offshore wind, low-carbon hydrogen, and biofuels.
Scaling up these technologies and reducing their costs will rely on large-scale engineering and project management skills, qualities that are an excellent match to those of prominent O&G players. For CCUS, the industry accounts for more than one-third of overall spending on new projects, and three-quarters of the CO2 picked up today in large-scale facilities is from O&G operations. If it can partner with governments and other stakeholders to create sustainable business models for large-scale investment, this has the potential to be a huge help for deployment.
Besides, electricity cannot be the only vector for the energy sector’s revolution. A commitment by oil companies to provide clean fuels to the world’s consumers is pivotal to the prospects for bringing down emissions. The 20% share of electricity in final energy consumption is growing, but in the face of increased demand for energy services, it is unable to carry out energy transitions on its own. Reducing emissions from core oil and gas procedures is a key step in helping countries get environmental payoffs from using less emissions-intensive fuels. Companies must, however, increase their investment levels in low-carbon hydrogen, biomethane and advanced biofuels, as these can deliver the energy system benefits of hydrocarbons without net carbon emissions. Within ten years, these low-carbon fuels would need to account for around 15% of overall investment in fuel supply.
While COP26 did not directly impinge on oil and gas output or use, there is no longer any doubt about the direction of travel, and momentum toward a carbon-free world gathered considerable pace.
Progress on plans to cut GHG was achieved on a number of fronts in the run-up to and during the Conference in Glasgow in early November. While there was no global agreement to control the use or production of oil and gas, the event increased the pressure on producers to address their own GHG emissions and plan for a future where they wind down fossil fuel production and manage carbon footprints wisely.
Countries and companies agreed to reduce methane emissions, phase down coal, and many more nations added their names to those already enrolled in net-zero targets. There was also progress on sustainable finance, electric vehicles, aviation and marine transport, and transition aid to developing countries. However, it is unlikely the commitments will avoid a rise in global temperatures of more than 1.5°C, and delegates have agreed to meet annually in an attempt to make more ambitious commitments to achieve that goal.
While there were no direct curbs on oil and gas production or use, it has added to growing activist shareholder momentum and precedes likely tougher regulation and higher taxes in many countries. Pressure includes moves to push big oil to sell off highly polluting assets (causing a switch in ownership toward NOCs and private equity) and even break up into legacy fossil fuel energy businesses and new energies and gas units [13].
Also at the Conference, the Beyond Oil and Gas Alliance set up earlier this year by Denmark and Costa Rica was joined by more countries, including France, Ireland, Sweden, and Wales, with California and New Zealand as associate members. The group aims to add pressure to phase out oil and gas. But most producers, including COP26 hosts, the United Kingdom, say oil and gas will still be needed for some time, and they must ensure consumers are not left short, and industries have time to transition.
[1] Gabbatiss, J. (2021, February 26th). UN: New national climate pledges will only cut emissions ‘by 2%’ over the next decade. Carbon Brief. https://www.carbonbrief.org/un-new-national-climate-pledges-will-only-cut-emissions-by-2-over-next-decade
[2] SEI, IISD, ODI, Climate Analytics, CICERO, & UNEP. (2019). The Production Gap Report 2019. https://productiongap.org/2019report/
[3] https://news.climate.columbia.edu/2020/08/20/kamala-harris-coalition-just-transition/
[4] https://www.iea.org/reports/the-oil-and-gas-industry-in-energy-transitions
[6] https://beyondoilandgasalliance.com/
[8] https://sdg.iisd.org/news/us-china-declaration-elimination-of-oil-and-gas-highlighted-at-cop-26/
[9] https://www.state.gov/u-s-china-joint-glasgow-declaration-on-enhancing-climate-action-in-the-2020s/
[11] https://ukcop26.org/cop-26-declaration-international-aviation-climate-ambition-coalition/
The article gives details of pig traps used for pigging operation of oil and gas pipelines.
The major focus of the article is the technical requirement for the successful design and construction of pig traps. The article’s key focus areas include the length of pig traps, length of minor and major barrel, the type of reducer, nozzle orientation and locations, supports requirements, etc.

Figure 1: Pig Trap
A pipeline is the most efficient means of transporting hydrocarbon products through a long distance. Pipelines used to convey hydrocarbon requires cleaning and integrity checks after a designated period.
Cleaning is necessitated by debris resulting from contaminated products which may accumulate on the pipeline, corrosion etc. Pipeline cleaning is performed by sending a cleaning tool (cleaning pig) through the pipeline. The action of the flowing fluid propels the pig tool from the start of the pipeline to the end.
Integrity checks are required to validate the state of the materials used for the pipeline construction. These include estimation of pipeline corrosion rate etc.
Checks are also required to validate the bend radius of the pipelines.
Multi-product pipelines utilise batching pigs used as barriers to separate the different products.
Based on the facts above, pipeline pigging is a very important activity during the operational life of the pipeline.
Pipeline pigging entails using a device called Pig to perform tasks such as cleaning, inspection, maintenance, batching, and dimension check on a new or existing pipeline. During pigging operation of an existing pipeline, pipeline operations are not stopped meaning the pigging tool is introduced into the flow stream and travels along the pipeline utilising the flow and pressure of the pipeline. Note that the flow rate may be reduced to the maximum required for the safe transportation of the Pig during pigging.
A key mechanical equipment required for pipeline pigging is the pig trap (Pig Launcher and Pig Receiver).
The Pig traps are static equipment through which the pigging tool is introduced into a pipeline and received from the pipeline. It comprises barrels, end closure for introducing a pig into a pipeline or removing a pig from a pipeline, and nozzle connections. Note that two pig traps are required (Pig Launcher and Pig Receiver) for a successful pigging operation. The pig traps may be permanently installed or temporarily installed.
Temporary or mobile pig traps are only installed when pigging operation is performed.
For Proper explanation, see below schematics of a pig launcher and a receiver.

Figure 2: Pig Launcher Schematics

Figure 3: Pig Receiver Schematics

The Pigging tool is fed into the pipeline through the pig launcher. It may be horizontal or vertical. Horizontal pig launchers are associated with onshore installations, while vertical installations are mostly found on offshore platforms.
The pigging tool is retrieved from the pipeline through the receiver. The debris is removed through the pig receiver when pipeline cleaning is performed. Most receivers, both onshore and offshore, are horizontally located.
The Major Barrel is the enlarged pipe section of a pig trap used to load or retrieve pigs.
The reducer is a fitting between the major and minor barrels. It connects the larger diameter major barrel to the smaller diameter minor barrel.
The minor barrel is the section between the reducer and the pig trap valve. It has the same diameter as the pipeline
The end closure is a fitting, including a removable part or assembly, which provides quick and easy access to the major barrel when open and seals the bore when closed.
These are flanged connections to the Pig trap. They are the mating connection points for piping and instruments installed on the pig trap
The key considerations when design are pig trap are highlighted below
Pig traps should be designed to the pipeline design code. If the pipeline is designed as per ASME B1.8, the pig trap should be designed based on the same code.
Although older pig traps (launchers and receivers) were designed based on ASME Section VIII Div. 1 pressure vessel code, however, these designs are not economical because given the same pipeline design parameters, a pig trap designed to ASME Section VIII Div. 1 will tend to be more expensive than that design to ASME B31.4 or B31.8 because of the resulting difference in material grades and thicknesses.
As stated in ASME B31.4 section 404.7.3 Closure heads such as flat, ellipsoidal (other than in para. 404.7.2), spherical, or conical heads are allowed for use under this Code. Such items shall be designed in accordance with Section VIII, Division 1, of the ASME Boiler and Pressure Vessel Code.
The traps shall also be fabricated as per the design code. All welds shall be subjected to NDT/NDE.
The pig traps should be fabricated of materials compatible with the pipeline, usually carbon steel.
Usually, the same materials used for the pipeline is recommended for the pig traps. For a large diameter pipeline, the grade of the materials of the major barrel may be increased to achieve a reduced wall thickness.
The size of the barrel is vital to a successful pigging operation.
For Pipelines with a nominal diameter smaller than DN 500 (NPS 20), it is required that the major barrel’s nominal diameter should be 50 mm (2 in) larger than the pipeline’s nominal diameter.
The actual internal diameter for thick pipelines should also be considered in determining the oversize. Assuming a NPS 12 pipeline, the outside diameter is 12 – 3/4in this implies the actual barrel size should be NPS 16 rather than NPS 14. NPS 14 does not meet the required 2in oversize.
For pipelines with a nominal diameter of DN 500 (NPS 20) and larger, it is required that the barrel’s nominal diameter should be 100 mm (4 in) larger than the pipeline’s nominal diameter.
The table below shows typical sizes of barrel sizes.

Table 1: Typical Major Barrel Size
The internal diameter of the main pipeline should be the same as that of the minor barrel.
If there is a variation in wall thickness greater than 2.4mm (0.10in), the transition in the internal diameter should be tapered to a maximum angle of 14 degrees to the pipe axis to permit smooth passage of pigs.
The pig trap (major barrel) should be designed for the maximum tool length utilised for the pipeline pigging (usually an intelligent pig). A margin of about 10% should be added to the maximum pigging tool length.
Usually, ultrasonic inspection tool lengths are considered conservative. If there are specific pig tool products to be used on the pipeline, the tool vendor should be contacted for the actual tool dimension to be used for pig trap design.
The table below shows the conservative dimensions of pig traps (Launcher and Receiver) and should be read in conjunction with the two figures below.

Figure 4: Pig Launcher Annotation

Figure 5: Pig Receiver Annotations

Table 2: Typical Barrel Length for Intelligent Pigs
The reducers should be eccentric for horizontal pig traps with flat on bottom. For vertical traps, the reducer should be concentric. For details of reducers, refer to ASME B16.9.
There are various nozzles connections to the pig traps; they are the interface for piping or instrument connection. Each nozzle should be appropriately located for effective pigging operation.
See below description of the nozzles.
On horizontal pig traps, all drain nozzles shall be located at the bottom of the trap.
All vents, blowdown, purge thermal relief, pig signaller and pressure gauges nozzles shall be located on top of the trap.
The kicker line, bypass line, and balance line should be located at the pipe’s side or top.
Nozzles should be evenly distributed around vertical traps and not clustered in the same location.
Nozzle locations are critical to a successful pigging operation. Installing a nozzle in the wrong location may hamper the pigging operation, while choosing the wrong nozzle size harms the pigging operation.
The pig trap valve nozzle is welded to the minor barrel. Usually, its size is equal to the pipeline size, and its internal diameter should flush with the internal diameter of the valve and the pig trap. The nozzle is connected to the pig trap valve used to isolate the pig trap from the operational pipeline system. The pig trap valve nozzle is only not applicable when the pig trap is permanently welded to the pipeline valve or pipeline.
The kicker line connects the bypass line to the major barrel, thus enabling the fluid diversion through the barrel to launch or receive a pig.
The kicker line nozzle on a pig launcher should be close to the end closure as possible, while the nozzle connected to the kicker line on the pig receiver should be as close as possible to the reducer. The kicker line nozzle should be approximately the major barrel’s mid-length for bi-directional pig traps.
Typical sizes of a kicker are shown in the table below.

Table 3: Kicker Line Size
Two drain nozzles should be provided for horizontal pig traps, one on the major barrel close to the end closure while the other on the minor barrel close to the pig trap valve.
For vertical pig traps; one drain nozzle shall be provided close to the pig trap valve
Recommended nominal diameter of the drain nozzle shall be at least 50 mm (2 in) for pipelines having a nominal diameter of less than 350 mm (14 in) and at least 100 mm (4 in) for larger size pipelines.
Usually, two equalisation nozzles are provided on the pig trap, one on the major barrel and the other on the minor barrel. In some instances, only one is provided on the minor barrel while the other end of the equalisation line is connected to the bypass line.
The equalisation line is connected to these nozzles. It is used to achieve equal pressure upstream and downstream of the pigging tool.
A minimum of two vent nozzles on a gas pipelines pig trap. One should be on the major barrel and the other on the minor barrel. Since only the barrel space will be vented, 2in size nozzle is suitable for this application.
Two pressure indicator nozzles should be welded on the pig trap, one on the major barrel close to the end closure and the other on the minor barrel close to the pig trap valve. 2in size nozzles are recommended for this application.
A Purge connection nozzle should be welded to the trap, preferably on the minor barrel. 2” size nozzle is suitable for this application.
When intrusive type pig signallers are used, a nozzle should be provided. Nozzles for this application are usually 2” in size. Though only one pig trap nozzle is welded on the trap, there should be provided on the pipeline just after the pig trap valve to install another pig signaller.
For pig launchers, the nozzle should be located close to the pig trap valve on the minor barrel, while on receivers, the nozzle should be located close to the reducer on the minor barrel.
Though the bypass line is not part of the pig trap, it is indirectly connected to the pig trap; therefore, it is worthy of giving details of this connection.
A bypass line connects the pipeline with the downstream or upstream facilities such as a tank farm, gas processing facilities etc.
The bypass from the main pipeline is achieved using a barred tee installed welded to the pipeline.
Typical sizes of bypass lines are given in the table below.

Table 4: Typical Bypass Line Size
All nozzle connections shall have a minimum rating corresponding to the pipeline design pressure and temperature. The nozzle rating shall also correspond to the mating nozzle for proper alignment.
For details of nozzle ratings, refer to ASME B16.5
Usually, saddle type support is used on pig traps. One support is on the major barrel, and the other is on the minor barrel. The supports should be designed to carry the weight of the trap filled with water.
Suppose there is not enough flexibility on the pipeline. In that case, the supports under the barrel should be of the sliding/clamp type to compensate for the expansion of the unrestrained part of the pipeline however. Fixed type supports may be used if there is enough justifiable flexibility
Lifting lugs should be designed to lift at least the minimum empty weight of the pig trap. The lugs should be appropriately located on top of the barrel. One of the lugs should be on the major barrel and the other on the minor barrel.
ASME B16.5: Pipe Flanges and Flanged Fittings NPS 1/2 through NPS 24
ASME B16.47: Large Diameter Steel Flanges NPS 26 through NPS 60 Metric/Inch Standard
ASME B 16.9: Factory-Made Wrought Buttwelding Fittings
ASME B31.4: Pipeline Transportation Systems for Liquid Hydrocarbons and Other Liquids
ASME B31.8: Gas Transmission and Distribution Piping Systems
DEP 31.40.10.13-Gen: Design of Pipeline Pig Trap Systems
The declared SDGs (Sustainable Development Goals) by United Nations coupled with net-zero emissions targets are continuously exerting pressures to drive the world towards cleaner fuels. Natural gas (LNG with regasification facilities where pipelines cannot transport natural gas) is among the cleaner hydrocarbon fuels and is witnessing increased demand in the world’s transition to clean energy use – being a reliable, available and lower-emissions energy source. On the one side, natural gas / regasified LNG is becoming an immediate option to lower emissions in hard-to-electrify sectors by replacing most polluting fuels (cow dung, coal and wood) in Asia. While on the other side, natural gas / regasified LNG plays an important role in supporting energy transition in the developed world through the provision of hybrid energy supply systems coupled with renewables, providing grid stability during cyclic renewable energy supplies.

Source: Shell LNG Outlook – February 2022
South Asia (mostly India) and China have been among the most affected countries in terms of carbon pollution due to biomass burning and coal for power generation. In India, it has been reported that anthropogenic emissions contribute approximately 80% to surface CO over the megacities of Delhi and Kolkata. Similarly, biomass burning contributes ~23% CO over Northeast India & Myanmar.[1] Large CO concentrations have been identified as a major indicator for determining environmental pollutants, particulate matter and resultant smog creation during winters.

Average Yearly CO levels determined in referred study related to South Asia (2015)
There may be a difference of opinion regarding future outlooks regarding the share of natural gas / LNG in the long-term energy mix. Still, there is no doubt that natural gas and LNG will continue needed. In South Asia, particularly in the Asian subcontinent, natural gas / LNG has a definite role to play in terms of replacing the declining domestic gas production to support economic growth – almost 2 billion out of 4.6 billion Asian population lives in South Asia (Afghanistan, Pakistan India, Nepal, Bhutan, Bangladesh and Sri Lanka constitute 43% of Asian population). The population of China is 1.4 billion. Thus, China a South Asia together constitute 74% of the Asian population. Thus, South Asian (mostly the Indian subcontinent) gas requirements are one of the biggest contributors for driving LNG demand growth, followed by China and the Asia Pacific (Taiwan, South Korea and Japan). In 2020, total LNG imports that landed in Asian countries were 250 MTPA (Million Tons Per Annum) out of 380 MTPA LNG imported by various countries of the world – Asian LNG imports accounted for 66% of total LNG trades worldwide. (Refer to figure below).

Source: Wood Mackenzie 2021 data
South Asia and China are different among Asia’s Top LNG Importing countries. While the Top LNG Importers Japan, Korea, and Taiwan, depend on LNG supplies, South Asia and China have options between pipeline gas imports and LNG. Thus, various modes or options available to Asian countries to fulfil their gas needs practically affect their ability to manoeuvre in the LNG market. South Asia and China have an edge due to their geographical location to get natural gas from large Russian and Central Asian gas reserves through pipelines. Traditionally, Europe used such options to their advantage for decades. However, with the changing geopolitics based on increased supplies of US Shale gas / LNG, Europe has been gradually shifting from Russian piped gas imports to US LNG imports.
Russian pipeline gas supplies have been continually declining towards Europe as the US LNG supplies to Europe increased tremendously during winter 2021 – 2022. Onwards, this will further reduce speedily due to the recent war in Ukraine. The graph on the left below indicates that in January 2022, Russian gas supplies to Europe were less than 60% (300 MMCMD) compared to what Europe received from Russia in January 2019. Similarly, the graph below indicates more than a doubling of US LNG supplies to Europe in January 2022 compared to December 2021.
Russia, in the meanwhile, is looking to sell more pipeline gas to the Asian subcontinent (South Asia). In a recent visit of Pakistan’s Prime Minister to Russia (February 2022), a new pipeline is announced as Kazakhstan – Afghanistan – Pakistan gas pipeline. This pipeline will carry Russian natural gas to South Asia via Kazakhstan. Kazakhstan’s gas network is connected to the Russian gas supply network (and gas sources) in Ukraine’s West and North. Thus, in the coming days, South Asia will have more control over LNG price options and the reliability of gas supplies. In recent winters, South Asian LNG imports declined due to high LNG prices as the relatively developing nations could not compete with the Asia Pacific and European buyers in an LNG price war.
Energy markets got destabilised due to the volatility in energy prices in 2021 – the main reason being a disruption in supplies from traditional pipeline connected sources. Despite high LNG production and export from the US, the European countries were helpless in paying rising LNG prices due to lower-than-expected output from renewable sources. European renewable energy supplies (RES) declined despite increased installed capacity, as indicated in the graphs below. South Asian countries also got affected due to high prices for the Asian sub-continent –proximity with JKF (Japan Korea Marker) and TTF (Title Transfer Facility – a virtual trading hub in the Netherlands for natural gas Spot Trades to Europe). The graph below indicates the stable price of Henry Hub (HH is US-based).

Pakistan, India and Bangladesh (combined) imported around 40 million tons of LNG in 2021 – making it the 4th largest LNG import region. These combined imports of LNG, despite rising LNG prices, by South Asia are expected to cross LNG imports of South Korea (3rd largest LNG importer currently) very soon. The graph below indicates that two South Asia (Pakistan and Bangladesh) were among the list of countries entering into Term Contracts with big LNG suppliers.

Most of Afghanistan does not currently have an established gas supply network, except gas distribution system in a couple of cities like Herat – mostly bottled LPG / LPG tankers are the main gaseous fuel source. Afghan Gas Enterprise (AGE) is a state-owned company that extracts and supplies natural gas. The AGE currently provides 95% of natural gas to industrial projects like Kod-e-Barq enterprise, Bayat and Ghazanfar IPP. The total gas consumption of Afghanistan is around 6 BCF annually. Natural gas currently accounts for less than 1% share in Afghanistan’s energy mix, with no possibilities of LNG imports due to it being a land-locked country.
Pakistan has had a well-established gas transmission and distribution system operating since the 1950s – 15,000 km high-pressure transmission lines and 150,000 km low-pressure distribution network operated by Sui Northern Gas Pipelines Limited, Sui Southern Gas Pipelines Limited and a few small companies operating single pipeline systems under Third Party Access arrangement. Two LNG regasification terminals (Engro Elengy Terminal and Pakistan GasPort Limited) have been commissioned in 2015 and 2017, supplying 1.2 BCFD gas to make up for declining domestic natural gas supplies – the combined nameplate capacity of two terminals is 9 MTPA. Currently, total natural gas consumption in Pakistan is around 5 BCFD (1,700 BCF gas annually), with more than 20% procured through imported LNG. Term contracts for importing LNG are made by Pakistan State Oil and Pakistan LNG Limited with Qatar Energy and Qatar Gas. Spot LNG is also procured as per requirements. Currently, natural gas (indigenous plus imported regasified LNG) accounts for more than 40% of Pakistan’s energy mix.
India has numerous gas companies supplying 6 BCFD gas to consumers. GAIL (India) Limited, Indraprastha Gas Limited, Gujarat State Petronet, Petronet LNG Limited, Gujarat Gas Limited, Mahanagar Gas Limited, Adani Total Gas Limited and Central UP Gas Limited are among the big names in the LNG / natural gas business. India’s natural gas pipeline network, currently operational and under construction, totals around 34,000 km (including high to low-pressure pipelines). Currently, India’s total natural gas consumption stands at 2,000 BCF annually, with more than 40% procured through imported LNG. Currently, natural gas accounts for only 7% of India’s energy mix, which is far below the global average of 24%.
There are currently five LNG import terminals operational in India with a total nameplate capacity of around 40 MTPA.
Sri Lanka is one of the two countries in South Asia whose share of renewable energy in the grid is over 50%; however, base-load electricity generating facilities are required to avoid capacity shortages when rainfall reduces to below-average values. Currently, Sri Lankan gas consumption is negligible, and the petroleum and gas supply industry has not been brought under regulatory reform. However, there are plans to set up an LNG regasification terminal, operate by Ceylon Petroleum Corporation, and construct a pipeline to supply regasified LNG to the power plant. Sri Lanka is expected to set up a natural gas company[1] as a subsidiary of the state-run Ceylon Petroleum Corporation under a public-private partnership to store, construct pipelines, transport and distribution, develop facilities and monitor local natural gas exploration and production.
Bangladesh has 2,000 km[2] of high-pressure transmission pipelines operated by Gas Transmission Company Limited (GTCL) is, a subsidiary of state-owned Petrobangla. Six gas distribution companies support GTCL in supplying 3 BCFD gas to consumers.
Total natural gas consumption in Bangladesh currently stands at 1,300 BCF annually, out of which around 130 BCF (or 10% of consumption) is met through LNG imports. Currently, natural gas (indigenous plus imported regasified LNG) accounts for around 60% of Bangladesh’s energy mix. Starting from 2018, Bangladesh utilises two 3.75 MTA floating storage regasification units (FSRUs) for importing LNG.
Myanmar has numerous gas companies supplying 1.5 BCFD gas to local consumers through 4,000 km of the domestic pipeline network. In addition, there are export pipelines to China and Thailand. Myanmar Oil and Gas Enterprise (MOGE) is the company responsible for the operation of these pipelines. Total natural gas consumption in Myanmar currently stands at 550 BCF annually with 100% indigenous production – Myanmar’s total natural gas production stands at 700 BCF annually with 150 BCF exports. Natural gas currently accounts for 39% of Myanmar’s energy mix. Hydropower and natural gas dominate Myanmar’s power sector fuel mix. The share of hydropower in the power generation mix is currently around 59.0%.
Myanmar has been exporting oil and gas[3] through two separate, parallel pipelines running from offshore blocks A-1 and A-3 in Myanmar to China – Shwe gas field located offshore of the Bay of Bengal is owned by a joint venture between Daewoo International, ONGC Videsh, MOGE, GAIL and Korea Gas Corp. The gas and oil pipelines have been operational since 2013 (gas pipeline transport capacity is 13 BCM (455 BCF) per year). The gas pipeline is 2,520km long, including the 793km Myanmar section and 1,727km China section – starting at Ramree Island in Kyaukryu (on the west coast of Myanmar) and ending at Kunming (the capital city of Yunnan province in China). The crude pipeline carries the crude oil that CNPC imports from Africa and the Middle East into China via Myanmar. Myanmar natural gas exports to Thailand currently stand at 0.6 BCFD. Myanmar export natural gas to Thailand from Total/Chevron’s Yadana field and PTTEP’s Zawtika fields.
Afghanistan, Pakistan, India, Bangladesh, and Sri Lanka are the South Asian countries that need more imported gas / LNG to meet their energy requirements and keep pace with Net Zero Emission goals. Pakistan and Bangladesh signed new term contracts in 2021, but India remained on the sidelines – it seems satisfied with its existing supply contracts. Higher LNG prices have reduced the capacity of South Asian nations to pay in the spot market. Indian LNG terminals indicate a decline in operations due to high LNG prices and a lack of downstream transportation capacity. Before the recent price hike, India planned to add 17 more LNG terminals. However, the current situation indicates that new LNG terminals in India will likely only add pressure on the existing terminals – running at low capacity due to lack of downstream takeaway capacity. But India needs to improve its energy mix to avoid further environmental degradation – currently 6% natural gas share in the Indian energy mix. Indian regulator PNGRB recently authorised 232 geographical areas (GAs) through 10 city gas distribution (CGD) bidding rounds that have covered more than 400 districts spread across 27 states and union territories. This covers around 71% of India’s population and 53% of the country. In addition, PNGRB plans to offer another 44 GAs in the upcoming bid round.
Indian government plans to increase the share of natural gas in its energy mix to 15% by 2030. India’s gas demand is expected to rise. To achieve this goal, the government of India is carefully weighing its options to import LNG at a lesser price – looking towards US Shale LNG supplies. Efforts are also underway to increase India’s domestic natural gas production. India’s natural gas production is expected to increase based on the collaboration of local investors like Reliance Industries Ltd and its foreign partner BP. This joint venture has been developing three deep-water gas developments in its KG D6 block off the Andhra Pradesh coast, which together are expected to produce around 1 billion cubic feet a day of natural gas by 2023. Also, state-owned Oil and Natural Gas Corporation Ltd has started gas production from its KG-DWN-98/2 field Situation
The situation is different for Pakistan and Afghanistan are actively looking for pipeline gas imports from Russian and Central Asian Republics – to avoid some of the volatility in LNG price and supply commitments.

Drag-reducing agents (DRA), or drag-reducing polymers (DRPs), are additives in pipelines that reduce turbulence in a pipe. The primary purpose of using traditional friction reducers in stimulation treatments is to overcome the tubular drag while pumping at high flow rates. Hydraulic fracturing is the main technology used to produce hydrocarbon from extremely low permeability rock. Hydraulic fracturing has been successfully implemented since its inception in 1947. To achieve commercial production from ultra-low permeability formation, development in fracturing fluids is the key factor for stimulation operations. Although a variety of fracturing fluids have been used to increase the productivity of unconventional reservoirs, fluids like low viscous (slickwater) and high viscous (crosslinkers/linear gel) 2 SPE-195191-MS still have some problems in terms of lower capability to carry proppant, creating formation damage, high-cost operation, and environmental concerns. In recent years, the oil industry has adopted high viscosity friction reducers (HVFRs) in fracturing fluids due to several operational and economic reasons.
Forrest and Grierson were the first to report a reduction in energy loss in the turbulent pipe flow of wood pulp fibre suspensions in water. This first report of drag reduction was unnoticed. Later, Mysels found that the skin friction for gasoline in pipe flow was significantly reduced by adding an aluminium disoap (an anionic surfactant). This was the first drag reduction result that was recognised. While doing polymer degradation research, Toms observed that adding a long-chain polymer (polymethyl methacrylate) in monochlorobenzene dramatically reduced the turbulent skin friction drag by up to 80%. At the First International Rheological Congress, Toms reported these results, identifying polymers as effective drag reducers. He observed that at a constant pressure gradient, the flow rate could be increased by adding the polymer. Therefore, it is usually referred to as the “Toms Effect.” Later, Savins first used the term “Drag Reduction.” The first commercial application for high polymer drags reduction was used in the 48-inch diameter 800-mile-long Alaska pipeline carrying crude oil from the North slope in Alaska to Valdez in the south of Alaska. Due to the very slow recovery (days) after high shear through a pump, aluminium soaps were not practical as a drag reducer. Later, drag reduction in aqueous systems using surfactant additives were found to be effective and
A friction reducer is one of the main components of slickwater fracture fluids and other stimulation fluids. The primary function of friction reducers is changing turbulent flow to laminar flow, reducing frictional loss during pumping fracturing fluids up to 80%. High viscosity friction reducers (HVFRs) have recently gained popularity as drilling and hydraulic fracturing fluids because the HVFRs exhibit numerous advantages. such as the following: • Providing pipe friction reduction during fracturing treatments • High regain conductivities compared to linear and crosslinked gels • Lower operational cost ◦ Use less water compared to conventional slickwater treatments, ◦ Consume fewer chemicals by 33-48% ◦ Require less equipment on location, ◦ Require less number of tanks trucks in the field • Placing better proppant volumes as previous fluids hybrid and crosslinked • Creating more fracture complexity using a less viscous fluid system • Achieve better hydrocarbon production results compare to or greater than other fluids. • Improves the flexibility to design treatments that balance technical, economic, and operational goals • Reduces freshwater, proppant, and equipment requirements compared with conventional fluid systems • Minimizes environmental footprint with a selection of engineered additives • Simplifies operations by reducing screen out risks
Polymers are effective drag reducers owing to their ability to suppress the formation of turbulent eddies at low concentrations. Toms indicated that DR could be achieved using polymer additives and concluded that different polymers could serve as effective drag reducers. The polymer was first commercially used in 1979 as a drag reducer in a 48-inch diameter and 800-mile-long Trans Alaska crude oil pipeline from North to South Alaska. Since then, polymer additives have been acknowledged for their DR ability. DR of up to 80% can be attained by adding only a few parts per million of polymer. It was concluded that polymers must exceed a minimum chain size for effective DR to occur. Drag reducing polymers are normally long-chain, high-molecular-weight (ranging from 1 to 10 million) polymers such as polyethene oxide (PEO) and polyacrylamide (PAA). They also exhibit non-Newtonian and viscoelastic behaviours. Polymer additives are the most studied among all drag-reducing methods because, at a low quantity, a significantly large DR can be attained. Parameters influencing the performances of drag-reducing polymers include flow rate, injection point, channel size, geometry, surface roughness, molecular weight, chain flexibility, structure, concentration, solvent, salt content, pH, and temperature. Generally, DR increases with increasing polymer concentration, molecular weight, Reynolds number, and flow rate.
The drag reduction caused by the addition of suspended solid matter has been the subject of study since the beginning of the last century. The study was initiated because turbid streams of water were found to flow faster than clear ones. One of the first comprehensive experimental works was undertaken in the 1940s. Despite this early start, more than ten years before investigators began a systematic study of solid suspension drag reduction. Suspensions may be of two different types, namely: (a) Granular or nearly spherical particles (b) Fibers. To date, the effects of solids suspended in flowing liquids have not been investigated as thoroughly as those of polymer additives, but, from the industrial point of view, suspensions of solids have the edge over that of polymers for the following two reasons: 1. The solid matter can be added and removed from the flowing liquid with great ease. 2. They suffer no mechanical degradation in most cases except in a few, as noted by some workers
The drag-reducing ability of biological additives came to light as serendipity. When models of prospective new ships were tested in towing tanks to determine their drag and propulsion characteristics, Hoyt was the first to notice the drastic variation in the turbulent flow properties of water in those tanks. He explained that the long-chain polysaccharides produced by living organisms during growth were the cause of this drag reduction. The drag reduction measurements initiated the study of the polysaccharides of several fresh glasses of water and marine algae. The effect of pH and temperature was studied on the bacterial production of drag-reducing polysaccharides. It was concluded that the bacteria could be cold-loving or heat-loving, but they are often more effective in alkaline media. They also show long-term stability and are thus superior to poly (ethylene oxide), which was used initially in towing tanks. Seawater slime and other freshwater biological growths have also been effective drag reducers.
“Surfactant” is a very convenient contraction of the term “surface-active agent.” It connotes an organic molecule or an unformulated compound having surface-active properties. Three surfactants, namely, anionic, cationic, and nonionic, have been investigated for drag reduction.
slip at wall theory: In 1948, Oldroyd was the first to suggest that polymer molecules, during flow, affected the region near the wall most strongly. His slip-at-the-wall theory has remained a mere engineering correlation method rather than a fundamental answer to drag reduction mechanism. It will remain until an improved method for measuring velocity profiles near the wall is found.
Sheer thinning wall theory: Toms proposed the idea of a shear-thinning wall layer with an extremely low viscosity, which resulted in lower friction coefficients for the drag-reducing solutions than for pure solvents
viscoelastic theory: It suggested that drag reduction could be due to two effects of viscoelasticity. 1)The instantaneous shear stress at the wall being smaller for viscoelastic fluid than for the corresponding Newtonian fluid 2) The renewal of the elements of liquid along the wall taking place more slowly in the case of viscoelastic fluid than in the case of a Newtonian fluid
Drag reducing additives are important in oil drilling applications and the maintenance of pumping equipment in pipelines
Here are some companies dealing with drag reducers
Recent research focuses on the use of polymer additives as drag-reducing agents, the general formulations of the additives, major issues involving the use of drag-reducing polymers, and its potential applications. However, despite the extensive works of drag reduction polymer, there are still no models that accurately explain the mechanism of drag reduction. More studies needed to be done to understand the phenomenon better. Therefore, future research areas and potential approaches are proposed for future work.
Drag reducers, also referred to as drag reducing agents (DRA) or flow improvers, are materials that minimise frictional pressure drop in a pipeline or conduit during fluid flow. Pressure loss is reduced by lowering the degree of turbulent motion in the flow. DRA provides more flow with the same energy or lower pressure drop for the same fluid velocity in pipelines. The resistance experienced by flowing fluid in contact with the pipe wall causes frictional pressure decrease or drag.
The frictional pressures experienced in laminar flow cannot be modified unless the fluid’s physical characteristics are altered. Most drag-reducing agents function without changing the fluid’s material characteristics, making them only useful in a turbulent flow [1]. The fluid molecules move randomly in a turbulent flow regime, wasting most of their energy as eddy currents and other indiscriminate mobility. The drag reduction agent works by interacting with the turbulence of the moving stream through the polymer structure.
Since they lower pumping power and enhance pipeline capacity, drag reduction in pipelines is a subject of significant practical engineering importance. DRAs are utilised in various engineering systems, including regional cooling and heating, oil transportation and distribution pipelines, etc. In 1979, it was first used commercially in the 1.2 m diameter Trans-Alaskan Pipeline, which saw a 50% reduction in drag and increased the pipeline’s capacity from 1.45 to 2.1 million barrels per day [2]. Consequently, the necessity for two pumping units, which were expected to meet the previously specified capacity increase, was eliminated. Since then, the DRAs have been employed in numerous petroleum product pipeline projects[3].
As a result, employing DRAs offers the following functions:
Pipeline drag reduction technology consists primarily of viscous drag reduction, rib drag reduction, bionic drag reduction, and wall vibrating drag reduction. The drag-reducing technology falls under the viscous drag reduction [4]. Compared to other techniques, the drag reducer through agents technique does not require the pipeline to be improved, and it is less expensive; as a result, it is frequently employed in oil pipeline transmission. Agents having a high molecular weight or a surfactant that can decrease turbulence in pipes might reduce drag. With the inclusion of DRA, the drag force is reduced, allowing oil to be transported at lower pressures [5], resulting in low pumping energy required and reduced cost. Additionally, the entire pipeline would be safer since it would be operated at a lower pressure as the DRA was included.
According to studies on drag-reduction mechanisms, the interplay among macrostructures and elastic macromolecules in turbulent flow causes this phenomenon [6]. In turbulent pipe flow, the region near the wall is constituted of a viscous sublayer, and a buffer layer plays an essential role in minimising drag.
The most important issue with drag reducer efficiency is polymer chain breakdown caused by shear stresses in a turbulent flow. Shear-induced degradation is particularly prone to ultrahigh-molecular-weight polymers [7]. Branched polymeric compounds and natural materials with semirigid structures are more susceptible than linear-chain agents [8].
Shear degradation is believed to be associated with the process of chain elongation. When the shear rate reaches a critical level, the chain degrades, and drag reduction quickly diminishes. The decrease of friction drag and heat transmission in turbulent flows of drag-reducing substances is incompletely understood [9]. These events are thought to be significantly linked to elastic fluid characteristics. However, not all viscoelastic fluids are drag-reducing, implying that viscoelasticity and drag reduction are most likely unrelated phenomena.
Since flow creates an analytic anisotropic fluid-structure and related characteristics, it is claimed that flow familiarisation is the primary source of reduction phenomena rather than fluid elasticity, which is a secondary cause. Laminar heat transfer amplification, on the other hand, could be a result of increased fluid elasticity.
The propagation of eddies can be damped by the viscoelastic characteristics of fluids, which is one of the processes of drag reduction. In Maxwell fluids with viscoelastic features, the transmission process of an isolated eddy was explored, and formulas explaining such occurrences were derived [10]. The study found that eddy transmission was dramatically reduced when the fluids’ viscoelastic characteristics increased.
Interpolymer complexes mediated by hydrogen bonding have proven effective drag reducers. When compared to their non-associating polymeric antecedents, the drag reduction levels in such polymer systems improve by a proportion of two to six. Their shear stability has also been demonstrated to be enhanced [11].
The soluble hydrocarbon polymers with a small polar group fraction can analyse the interplay effect and drag reduction. According to research observations, interpolymer affiliations appear to reduce the dilute solution drag reduction capabilities of single connecting polymers containing similar polar groups.
Since the advantageous interpolymer associations construct larger structures of higher apparent molecular mass, interpolymer complexes formed by one polymer with cationic groups and another polymer with anionic groups can overcome this limitation and improve dilute solution drag reduction activity. The latter associations may improve the polymers’ resilience to degradation in turbulent flows.
Industrial activities such as long-distance liquid transportation and oil well operations might advantage from minimising the drag in a turbulent flow. Still, the challenge of polymer degradation makes it difficult to achieve this.
The polymer decomposed more in a poor solvent at low Reynolds numbers, but the reverse effect was seen at high Reynolds numbers. The dimensionless concentration c(η) was shown to rise with molecular weight and polymer concentration as expressed by the critical Reynolds number.
Poly (saccharide) guar gum is employed in aquatic environments to reduce turbulent drag. It dramatically decreases friction drag in a turbulent flow [12].
A horizontal pipe was used to investigate the drag-reducing characteristics (PAM) in a two-phase water/airflow [13]. The polymer’s characteristics were examined in single-phase water flow, and the result was found to complement the pressure drop reduction. Positive effects in two-phase flow were discovered to depend on the flowing liquid Reynolds number. As a result, the drag decrease was negative or minimal in the fluids that changed the density while moving in the vertical direction. The drag reduction seems to originate in the liquid slug rather than the layer beneath the bubble in a two-phase flow. The drag-reducing agents appear to have little effect on the flow regime. Drag reducers have been effective corrosion inhibitors in the multiphase flow because of their ability to make smoother the flow profile close to the wall [14].
Drag reducing agents are also effective in the gas flow as well. Ammonia gas (NH3) is often utilised in natural gas for storage or pipeline transit at pressures more than 5.5 MPa (800 psi). The temperature and pressure need to be adjusted so that ammonia should not convert into the liquid phase. The energy required to compress or pump the combination of natural gas with ammonia is less than that energy required to compress or pump a comparable volume of natural gas alone. The pumping process through long pipelines is further assisted by the refrigerant or cooling effect of ammonia, which lowers the temperature of the gas being conveyed when more than 4% by volume of ammonia is involved [15].
A specified amount of chosen organo-polymeric microfibrils can be added to a liquid to decrease friction loss while maintaining optimal stability [16]. To be processed into microfibrils, polymeric materials must be insoluble yet extremely dispersible in a particular solvent.
A solid organic polymer in the form of microfibrils has an average diameter between 100-1000 Å, length in the range 1-500 μm, and length to diameter ratio (aspect ratio) of 10- 1,000,000.
Certain cationic surfactant solutions containing counter ions are widely recognised for reducing drag in a turbulent flow. The existence of rod-like micelles generated by single surfactant molecules over a specific concentration characterises drag-reducing surfactant solutions [1]. The temperature and electrolyte content significantly impact the essential micelle concentration. Shear viscosity assessments of drag-reducing surfactant solutions demonstrate that at shear rates above a critical value, the viscosity increases abruptly, resulting in the formation of a shear-induced state. The micelles coalesce into larger structures and are completely aligned in the flow direction.
A non-agglomerating suspension of UHMWP in water with tiny quantities of surfactant can be introduced into the flowing stream hydrocarbons for improving flow characteristics and reducing the energy required to carry out the pumping process [17]. Polymerisation produces precisely split UHMWP, which is subsequently cryoground below the glass transition temperature. This way, it acts as a drag reducer by absorbing the vibrations generated by turbulence and shifting the flow towards the laminar.
Various -olefin copolymers are employed as drag reducers. Concentrates can be formulated by polymer precipitation from a hydrocarbon solution with an isopropyl alcohol [18]. In flowing hydrocarbon streams, the resultant slurry concentration dissolves quickly. A non-agglomerating, non-aqueous solution may be made by covering poly-olefins with a fatty acid wax as a fragmentation agent and scattering it in a lengthier chain of alcohol [19].
An emulsion-based polymerisation technique is used to produce latex drag reducers, which are distributed in a continuous phase and may be changed to increase the polymer’s hydrocarbon solubility. 2-Ethylhexyl methacrylate is the preferred monomer. Traditional emulsion polymerisation methods are used for the polymerisation [1]. The emulsion polymerisation produces the initial latex composition consisting of colloidal particle dispersion. Water and surfactant make up the continuous phase. Additional surfactants and organic solvents can be added to the latex to modify or formulate it, and viscosity characteristics can be changed to get the required properties. Conventional or umbilical delivery techniques can be utilised to introduce a drag reducer into the pipeline.
Microencapsulating a monomer or a polymer technique can also create highly concentrated drag-reducing agents. Microencapsulation can be performed before, during, or after polymerising a monomer into an efficient drag-reducing polymer. A catalyst must be present if the encapsulation is performed before or during polymerisation, although little or no solvent is needed. As a result, the microcapsule undergoes bulk polymerisation. Microencapsulated drag minimisation can be introduced into a fluid stream before, during, or after removing the inert capsule or shell. There is no need for injection equipment or another specialised probe to enter the drag-reducing slurry into the liquid stream and no need for polymer grinding to form a suitable grad reducing agent [20].
Aluminium carboxylate based drag-reducing agents is non-polymeric in nature. These additives are not affected by shear, and they do not produce undesired changes in the fluid composition and emulsion of the fluid which is going to be treated, nor do they induce unwanted foaming.
Aluminium carboxylate and fatty acids are the constituents of this compound. Aluminium carboxylates are made from fatty acid aluminium salts such as octoates, oleates, naphthenates, or stearates [21]. Long-chain carboxylic acids are used to make fatty acids. Aluminium salts with a mix of short and long-chain carboxylic acids may offer the best balance of viscosity alteration and drag reduction.
Solid-particle suspensions are used to reduce resistance by adding solid particles to a flowing stream utilising two different forms of suspensions [22], granulation and fibre. The size and composition of granular and fibre suspensions are different. Granular resembles a sphere-shaped particle, whereas fibre is a component of many materials. Based on the stated effect, the benefit of various drag reduction approaches is that suspensions utilised in moving fluids may be easily separated due to their larger size. Furthermore, research on the degradation of solid-suspension particles shows that the suspension has little effect on the moving fluid components [23]. This ease of use is unquestionably crucial in its application to the marine sector on a large scale. Sand, charcoal, asbestos, nylon and other suspensions are examples of solid suspensions.
Small amounts of particular surfactants, polymers, and combinations added to water can significantly reduce frictional drag [24]. The formation of a microstructure made up of long micellar associates is a crucial prerequisite for the drag reduction phenomena to exist in the solution. Cationic, anionic, nonionic, and amphoteric surfactants can all cause drag reduction; however, the bulk of research published to date has focused on the cationic surfactants [25]. Cationic surfactants have the advantage of being stable and performing well throughout a wide temperature range. The downside is that quaternary ammonium compounds are harmful to marine species and slowly biodegrade [26]. Cationic surfactants can be substituted with more ecologically friendly nonionic surfactants at relatively low temperatures.
The transporting companies of liquid hydrocarbon chemicals through pipelines can save money by eliminating the requirement for underused intermediate or accelerator pump stations by utilising a drag-reducing flow improver [27]. Product lines operated at a low flow rate in a predesigned pipeline due to consumption requirements or employing temporary boosters can also save transmission costs. The overall advantages are most likely to be seen in 6–8-in lines running at 67% to 92% of their specified throughput capacity. Engineers have proven significant power saving of up to 22% (through lower demand charges and reduced energy consumption) for systems that employ booster stations 85% of the transmission duration. Depending on the width of the line and power rates, overall energy cost reductions can exceed 45% when stations are only operational 70% of the time [1].
Another advantage of adopting drag reduction agents is that they may be introduced instantly or temporarily, allowing companies much flexibility in overall operations. The research discovered that the necessary DRA-injection rates for multiphase flows were four times greater than for stabilised crude oil [3]. This was linked to the multiphase system’s increased shear degradation caused by the higher degree of flow turbulence. DRAs are evaluated based on their efficacy, which is defined as:

Several factors influence DRA effectiveness, including pipe diameter, temperature, the viscosity of the fluid, and the inclusion of hydrocarbon and/or water. In conclusion, DRAs are very effective in fluid transmission operations, and the appropriate selection of them during particular applications is crucial.
[1] J. Fink, Petroleum engineer’s guide to oil field chemicals and fluids. Gulf Professional Publishing, 2021.
[2] E. D. Burger, W. R. Munk, and H. A. Wahl, “Flow increase in the Trans Alaska Pipeline through use of a polymeric drag-reducing additive,” Journal of petroleum Technology, vol. 34, no. 02, pp. 377-386, 1982.
[3] B. Berge and O. Solsvik, “Increased pipeline throughput using drag reducer additives (DRA): Field experiences,” in European Petroleum Conference, 1996: OnePetro.
[4] X. Dai, C. Liu, J. Zhao, L. Li, S. Yin, and H. Liu, “Optimization of application conditions of drag reduction agent in product oil pipelines,” ACS omega, vol. 5, no. 26, pp. 15931-15935, 2020.
[5] J.-I. Sohn, C. Kim, H. Choi, and M. Jhon, “Drag-reduction effectiveness of xanthan gum in a rotating disk apparatus,” Carbohydrate Polymers, vol. 45, no. 1, pp. 61-68, 2001.
[6] O.-K. Kim and L.-S. Choi, “Shear-Resistant Drag Reduction Polymers. Part 1. Molecular Investigations of Polymer Drag Reduction and the Development of Laboratory Screening Methods,” NAVAL RESEARCH LAB WASHINGTON DC, 1990.
[7] B. Gampert, “The influence of polymer additives on velocity and temperature fields: Symposium [on” the Influence of Polymer Additives on Velocity and Temperature Fields”], Univ.-GH-Essen, Germany, June 26-28, 1984,” ed: Springer, 1985.
[8] H.-F. D. Chang and J. Meng, “Prediction of drag reduction from rheological properties of dilute polymer solutions,” Physicochem Hydrodyn, vol. 9, p. 33, 1987.
[9] M. Kostic, “On turbulent drag and heat transfer reduction phenomena and laminar heat transfer enhancement in non-circular duct flow of certain non-Newtonian fluids,” International journal of heat and mass transfer, vol. 37, pp. 133-147, 1994.
[10] L. Zhaomin, “Effect Of Fluid Viscoelasticity On Isolated Eddy Transmission,” Journal of the University of Petroleum, China, 1991.
[11] T. Moussa and C. Tiu, “Factors affecting polymer degradation in turbulent pipe flow,” Chemical Engineering Science, vol. 49, no. 10, pp. 1681-1692, 1994.
[12] C. Hong, K. Zhang, H. Choi, and S. Yoon, “Mechanical degradation of polysaccharide guar gum under turbulent flow,” Journal of industrial and engineering chemistry, vol. 16, no. 2, pp. 178-180, 2010.
[13] G. Saether, K. Kubberud, S. Nuland, and M. Lingelem, “Drag reduction in two phase flow,” in Proceedings of the Fourth International Conference on Multiphase Flow, France, 1989, pp. 171-184.
[14] W. P. Jepson, M. Gopal, and C. Kang, “The effect of drag reducing agents on corrosion in multiphase flow,” in CORROSION 98, 1998: OnePetro.
[15] I. Morris and G. Perry, “High pressure storage and transport of natural gas containing added C2 or C3, or ammonia, hydrogen fluoride or carbon monoxide,” ed: Google Patents, 2001.
[16] T. Shinomura, “Method of reducing friction losses in flowing liquids,” ed: Google Patents, 1988.
[17] A. Dindi, R. L. Johnston, Y. N. Lee, and D. F. Massouda, “Slurry drag reducer,” ed: Google Patents, 1996.
[18] K. Fairchild, R. Tipton, J. F. Motier, and N. S. Kommareddi, “Low viscosity, high concentration drag reducing agent and method therefor,” ed: Google Patents, 1998.
[19] R. L. Johnston and Y. N. Lee, “Non-aqueous drag reducing suspensions,” WO Patent, vol. 16, p. 23, 1998.
[20] N. S. Kommareddi and L. J. Rzeznik, “Microencapsulated drag reducing agents,” ed: Google Patents, 2000.
[21] V. Jovancicevic, S. Campbell, S. Ramachandran, P. Hammonds, and S. J. Weghorn, “Aluminum carboxylate drag reducers for hydrocarbon emulsions,” ed: Google Patents, 2007.
[22] V. A. Vanoni, “Transportation of suspended sediment by water,” Transactions of the American Society of Civil Engineers, vol. 111, no. 1, pp. 67-102, 1946.
[23] R. Vanasse, B. Coupal, and M. Boulos, “Hydraulic transport of peat moss suspensions,” Can. J. Chem. Eng.;(Canada), vol. 57, no. 2, 1979.
[24] J. L. Zakin, B. Lu, and H.-W. Bewersdorff, “Surfactant drag reduction,” Reviews in Chemical Engineering, vol. 14, no. 4-5, pp. 253-320, 1998.
[25] J. Różański, “Flow of drag-reducing surfactant solutions in rough pipes,” Journal of Non-Newtonian Fluid Mechanics, vol. 166, no. 5-6, pp. 279-288, 2011.
[26] M. Hellsten, “Drag-reducing surfactants,” Journal of surfactants and detergents, vol. 5, no. 1, pp. 65-70, 2002.
[27] C. L. GOUDY, “How flow improvers can reduce liquid line operating costs,” Pipe line industry, vol. 74, no. 6, pp. 49-51, 1991.
During shutdowns at oil plants, processing and storage equipment are regularly examined. If storage tanks, processing units, production lines, and heat exchangers need to be drained, cleaning processes might take several weeks. Hazardous chemicals and hydrogen sulfide gas, as well as concentrations of combustible iron sulfide and other contaminating material, can be extremely hazardous, which is why they must be removed before the examination. Conventional mechanical washing techniques have been employed to clean flammable hydrocarbons and hydrogen sulfide gases for several years, including medium and high-pressure water jetting, steam operations, and hot or cold water cleaning techniques. Unfortunately, enormous amounts of water are needed, and the wastewater produced might have a high Total Organic Carbon. Stronger chemical cleaning and degassing chemicals have been developed in response to regulatory, safety, and environmental requirements to save downtime by minimising the need for mechanical cleaning.
The technology used and the cleaning technique used will be determined by the machinery to be cleaned. Chemical cleaning of a crude oil tank or sludge oil system employing external mobile heat exchangers, for example, will take longer than chemical cleaning of a distillation column or heat exchanger, which may be done using high-pressure cleaning equipment. Chemical cleaning removes organic and inorganic fouling particles from processing lines, distillation equipment, and metal surfaces using a mix of solvents, fluid velocity, and, in most cases, heat. The heat will be supplied by steaming, hot water injection, or heating the metal surfaces. At the same time, the fluid velocity will be provided by spraying, stirring, circulation, steam, or air addition, and the solvency will be determined by the chemical composition of the cleaning agents and their concentrations. [1]
Inorganic and organic acids, chelating and complexing agents, alkaline cleansers, surfactants, organic solvents, and speciality additives are the most common chemicals used to clean equipment. Common acid cleaning chemicals such as inhibited sulphuric acid and hydrochloric acid, phosphoric acid, citric acid, or other weaker acids remove oxides and scales. The metal surface can be cleaned slowly or quickly by changing the chemical concentration, temperature, and agitation. Concentrated solutions and greater temperatures speed up the cleaning process, but they also produce hazardous and corrosive fumes, as well as an increased risk of corrosion. [2]
Caustic cleaning chemicals are less efficient and cost less than acid cleaning agents, but they are better at removing organic soils, such as oils and grease, than acids. Because of their detrimental environmental effects, chelating and complexing additives comprising EDTA, NTA, sodium diethanolglycine, or ethylenediamine play a lesser role in refinery cleaning operations. Surfactants can be anionic, nonionic, or amphoteric, and they’re sometimes used with organic solvents to boost their cleaning efficacy.
Cleaning chemicals are often used to remove scale and foul (such as viscous fouling and pyrophoric iron sulfides) from metal surfaces. In addition to these criteria, cleaning and degassing chemicals for refinery and petrochemical processes are developed to reduce benzene and other toxic hydrocarbons in the vapour phase, as well as hydrogen sulfide. These chemicals are usually injected into a liquid phase, which necessitates the hydrocarbon phase being drained first. Cleaning and degassing chemicals are typically planned for injection into the wash water phase at temperatures ranging from 60 to 100 degrees Celsius, with circulation periods ranging from 2 to 16 hours. For removing hydrogen sulfide and reactive hydrocarbons, certain cleaning chemicals generate a brief emulsion. Inside the API separator or a separate holding tank, the emulsion will eventually break down on its own. After the cleaning step is done, an emulsion breaker can speed up the separating process. Because the requisite storage tanks are employed for other uses during scheduled downtimes, and some oil companies reject to apply chemical cleaning procedures that form emulsions, the periodic storage of cleaning chemicals for emulsion breaking is limited in many circumstances. However, some chemical cleaning procedures have been tasked with providing cleaning and degassing chemicals that produce a transient emulsion and have no emulsification propensity. [ 3]

Figure 1 Degassing Process
Refiners are highly interested in eliminating or minimising iron sulfide formations because of the volatile nature of iron sulfide and the possibility of accidental fire. Although certain chemicals may eradicate tiny, isolated iron sulfide deposits, they have limits. They are frequently less successful when dispersed across the distillation apparatus’s packing material.
Because the cleaning chemicals are designed to remove flammable compounds and hydrogen sulfide, they may approach their limitations if increasing levels of ferrous sulfide deposits are predicted. As a result, a solution for removing iron sulfide deposits quickly and effectively has been created. Because this composition does not create hydrogen sulfide or solid reaction products, it is appropriate for iron sulfide dissolving applications. It can also be used with certain unique hydrogen sulfide and benzene removal chemicals to offer a successful, all-around chemical treatment procedure. [4]

Figure 2 Iron Sulfide Deposits
Sludge constantly collects oil products and heavy crude storage tanks at the bottom. Traditional cleaning procedures might take many days or even weeks when these store tanks are drained and cleaned. As a result, new chemical cleaning procedures have been devised to minimise the time it takes to remove sludge from the tank.
In the oil refining sector, there are a variety of conventional cleaning processes, and every cleaning method may be classified according to the cleaning procedure. Some cleaning techniques may necessitate using a chemical in conjunction with medium to high-pressure water jetting. In contrast, others will necessitate using a chemical in conjunction with transportable heat exchangers, hot water, gasoline, petroleum chelating agents, or other mechanical techniques. It is critical to clarify needs and check restrictions ahead of time in all circumstances.
A thorough tank inspection and lab testing can be used to assess the efficacy of the chosen cleaning chemical. Because huge storage tanks are rarely homogeneous, samples should be gathered from as many locations as feasible. A cleaned tank is one in which the floor is free of hydrocarbon and debris, as well as the tank has no gas. The selected chemical cleaning approach may not be suitable in some exceptional instances when catalytic sludge has been kept in the tank. If there are large volumes of combustible iron deposits in the tank, the cleaning chemicals have limitations. In such circumstances, specialist chemicals for eliminating combustible iron sulfide will get over this problem.
While clean-up techniques may need chemical dosing pumps, portable heat exchange equipment, high-pressure water jetting, hot water, gasoline, or diesel chelating agents, the use of the chemicals for a tower cleaning and degassing operation is relatively straightforward. The heat exchangers and compressors in the refinery can be employed to supply heat and fluid velocity during the shutdown phase. The process conditions determine how the chemical is applied to the system. It isn’t always practical to install a mechanism that allows the chemical to be injected into the system.
It is not always practical to build a method that allows the chemical to be pumped back into the system. As a result, additional chemicals and wash water are necessary. In this scenario, the chemical must be added to the washing water at the top of a distillation process or reflux column (cascading method). Additional instability on the plates or packing can be achieved by adding steam. The chemical will be washed down the drain with the washing water.
The most effective approach is the circulation technique, which allows the chemical to be circulated back into the system, lowering chemical expenses. First, the items must be drained. Hydrocarbon or water is used to wash and fill the system, based on the composition of the cleaning chemical. Firstly, the cleaning chemical may be injected at the prescribed temperature range as soon as possible; the unit must be supplied to one-third of its capacity. It’s critical to keep an eye on the cleaning procedure. During the cleaning process, the stream of the cleaning chemical, the temperature conditions, the chemical activity, and the change in colour of the sample were all monitored. The cleaning solution should be emptied, and the system cleansed again after cycling for a few hours (cleaning time varies depending on the chemical and process conditions). In some circumstances, the chemical must be dispensed constantly in the vapour phase (steaming technique) for aqueous applications, requiring condensing in the distillation tower. Small pumps can keep the chemical flowing at a steady rate.
While the circulation approach is already the most cost-effective, it has another significant benefit. The chemical may be injected at various points throughout the system, reducing the time it takes for the chemicals and the wash liquid to combine. Small, strong pumps could administer the chemical in places where an electric pump would be difficult to install.
The entire duration for one wash cycle will vary depending on whether simply chemical washing of the distillation apparatus is necessary or whether flammable hydrocarbon or hydrogen sulfide must also be removed. Discharging the distillation byproducts, rinsing with an appropriate wash liquid, refilling with the wash solvent, injecting the chemicals, recirculating for a few hours, and discharging within three to four hours are all part of a cleaning cycle. It is usually preferable to apply a 1 per cent dilution thrice than a 2per content dilution once in cleaning efficiency. Due to time constraints during turnarounds, however, this is not always possible. There should be no combustible iron deposit, combustible hydrocarbons, or hydrogen sulfide once the maintenance holes and pipework have been opened. [5]

Figure 3 Cleaning Process
A refinery typically has a large number of fuel gas combustion equipment. They’re linked to a major fuel gas distribution network that gathers gas streams from various refinery areas and routes them to refining heaters or furnaces. The fuel gas’s composition and quality vary depending on the crude oil, but the primary constituents are methane, ethane, and ethylene, along with surplus hydrogen. Carryover of hydrocarbon condensate to the fuel gas burners is typical, and the hydrocarbon condensation can flow into the firebox, posing a dangerous condition. Ammonia spillover with fuel gas is also prevalent. The possible creation of ammonium salt deposits, in addition to the condensing water or heavy compounds in the fuel distribution network, is regarded as a key element for the fuel gas system’s continuous and efficient functioning. [6]
Block burner nozzles take four to five person-hours of mechanical cleaning, and a typical burner cleaning cycle lasts three to four months. Mechanical cleaning might cost a hundred million euros per year if you have 30–50 heaters with many burner nozzles. Even though ammonia salts are water-soluble, steam-cleaning treatments are typically ineffective. Advanced chemical cleaning is an alternative to mechanical and steam cleaning, in which the advanced chemicals are injected into the fuel gas system to eliminate ammonium salt deposits. The fouling material may be removed in a matter of minutes, restoring the burner flames’ appearance and extending the burner tips’ life.
A proper assessment and lab tests before and after tank cleaning helps assess the effectiveness of the cleaning process. It’s critical to learn about the bottom sludge’s composition, which might include oil, water, volatile substances, ash, and sediments. The amount of water and sediment in crude oils is important since it might cause the distillation equipment to corrode. To assess the net amounts of natural oil in sales, an assessment of bottom sediments is necessary. Recovered oil may be sent to the refining operation using the cleaning technique, improving refinery profit.
When adequate samples are collected, the optimum results are produced. Because the oil tanks are not homogeneous, samples should be gathered from as many locations as feasible. When it comes to taking samples from oil tanks, many refineries employ a variety of sample takers. The water intake can be utilised for sampling if there are no sample points are. Any sludge-like substance can be collected when the valve is opened. Although this selection method may not be accurate, it is preferable to take no sample at all.
Distillation equipment will need to be chemically cleaned for around 10 hours. SamToSamco monitors the cleaning’s progress; samples can be obtained before and through the treatment or refinery cleaning operations; common characteristics include the concentration of active ingredients, the heat of the washing solvent, colours, acidity, iron content, chloride ions, ammonia, and sulfides. The samples appear to get increasingly unclean during cleaning, and the increase in analysed iron, chlorides, sulfides, and ammonia suggests that the contaminated material is being mobilised. When a mobilised rise in concentrations of these variables slows down, it means the cleaning is coming to a conclusion or that additional or new cleaning chemicals are needed.
The heat-transfer factor and pressure drop in heat exchangers, a sample of contaminated materials, ultrasonic measurement equipment, and previous shutdown reports on observed contamina are useful resources for determining the quantities of cleaning chemicals required. Cleaning is more difficult in tanks and vessels with inadequate agitation and distillation units with packing. It’s a good sign that the right cleaning chemical and techniques were chosen if these locations end up looking very clean.

Figure 4 Distilattion Column after chemical cleaning
Heating systems, oil tanks, heat exchange systems, coolers, hydraulic systems, reactors, compressors, piping systems, refinery towers, and cooling systems are examples of refinery equipment often cleaned chemically. Much of the labour involved in a refinery turnaround is maintenance, and the shutdown is meticulously scheduled months in advance. Regulatory, safety and ecological standards increase the demands on oil refineries and other petroleum facilities’ turnaround processes. The selection of the cleaning process and the chemicals depend upon the following critical factors:
The cleaning chemical must be properly chosen. Concentrated solutions of blocked acid cleansers at higher temperatures can produce harmful and corrosive vapours and stress corrosion cracks in high nickel alloys. Only a few scale varieties can be removed using alkaline cleansers, and greater temperatures are necessary.
Degassing and decontamination chemicals, including patented solutions to eliminate combustible iron sulfide deposits, have been created and may be solvent or water-based. Refineries prefer Water-based and solvent-based cleansers that do not generate emulsions. These products will clean metal surfaces more quickly and safely while lowering benzene and other volatile hydrocarbons, hydrogen sulfide, and ammonia levels. This will assist cut down on shutdown time, air pollution, wastage, labour expenses, and environmental costs.
[1] R. A. Shank, S. Gharaibeh, T. R. McCartney, and M. Panunzio, “Decontamination of a Vacuum Distillation Unit: Mechanical Versus Chemical Cleaning; A Case Study,” in CORROSION 2017, 2017: OnePetro.
[2] R. Haydu, W. E. Brantley III, and J. J. R. K. M. E. i. C. L. R. H. Casenhiser, “INDUSTRIAL CHEMICAL CLEANING METHODS,” 2008.
[3] A. Groysman, “Corrosion problems and solutions at oil refinery and petrochemical units,” in Corrosion problems and solutions in oil refining and petrochemical industry: Springer, 2017, pp. 37-99.
[4] A. J. K. a. o. m. Groysman, “Corrosion problems and solutions in oil, gas, refining and petrochemical industry,” vol. 61, no. 3, pp. 100-117, 2017.
[5] B. J. P. t. q. Otzisk, “Chemical cleaning and degassing refinery equipment,” vol. 13, no. 1, p. 77, 2008.
[6] M. K. Karmakar, P. Chandra, and P. K. J. J. o. E. C. E. Chatterjee, “A review on the fuel gas cleaning technologies in gasification process,” vol. 3, no. 2, pp. 689-702, 2015.