This article is developed to give a general overview of a typical petroleum storage terminal or depot. It will cover some of the technical requirements to be fulfilled in designing and operating a storage terminal.
And will lay more emphasis on storage facilities for refined petroleum products such as Premium Motor Spirit (PMS), Automotive Gas oil (AGO), and Dual Purpose Kerosene (DPK). Terminals storing Liquefied Petroleum Gas and Liquefied Natural Gas (LNG) are not covered in this article.
The storage tanks described in this article are above ground atmospheric tanks. Low-pressure above-ground tanks are not covered in this article.
Most of the guideline and recommendations discussed in this article are referenced to the author’s general experience, the National Fire Protection Association (NFPA) codes, American Petroleum Institute (API) Standards, the American Society of Mechanical Engineers (ASME) Codes, Design and Engineering Practice (SPDC DEP’s), and the Department of Petroleum Resources (DPR) guidelines..

Figure 1: Satellite Imagery of Petroleum Products Storage Terminal
Fuel is an essential hydrocarbon “commodity” in the day to day affairs of humans. It is used for energy generation, cooking, heating, etc. The above-listed use of fuel is achieved through the combustion of these hydrocarbon compounds to release energy.
Fuel can be in the form of liquid or gaseous hydrocarbon. Typical liquid hydrocarbon fuel includes Premium motor spirit, dual-purpose kerosene, automotive gas oil, liquefied petroleum gas, etc. while gaseous hydrocarbon fuel includes methane, ethane butane, etc.
Generally, most of the liquid hydrocarbons such as Gasoline (PMS), ATK, AGO, DPK are obtained from the fractional distillation of crude oil.
Liquid hydrocarbons are the most widely used fuel to date except the current shift to hydrocarbon gas resulting from climate change-related issues.
The application of liquid hydrocarbon fuel cannot be overemphasised including
Fuel products are not directly drawn from the source and transported to end-users; they are temporarily stored in designated facilities. Crude oil is produced from wells, transported to refineries for processing into various forms of fuel, and sent to extensive storage facilities where they are temporarily held. Fuel is most times further transported to mini-storage facilities or dispensing facilities for onward delivery to end-users.
Storage facilities are sited in strategic locations guided by local and international regulations and company requirements.
The size of a fuel storage facility depends mostly on the market analysis, the holding capacity desired, and regulation requirements.
As defined in NFPA 30, section 3.3.51.1, above-ground storage tanks are those installed above grade, at grade, or below grade without backfill.
As per NFPA section 3.3.51.2*, Atmospheric Tank is a storage tank that has been designed to operate at pressures from atmospheric through a gauge pressure of 1.0 psi (6.9 kPa) (i.e., 760 mmHg through 812 mm Hg) measured at the top of the tank.
As defined in section 4.2.6 of NFPA 30, this is the pressure measured in pounds per square inch, absolute (psia), exerted by a liquid, as determined by ASTM D 323, Standard.
The True Vapour Pressure (TVP) is a measure of the volatility of petroleum distillate fuels. It is the equilibrium partial pressure that is exerted by a volatile organic liquid measured as a function of temperature. The true vapour pressure is estimated as per ASTM D 2879 (Standard Test Method for Vapour Pressure-Temperature Relationship and Initial Decomposition Temperature of Liquids by Isoteniscope)
Flammable liquids, as defined in section 3.3.33.2 and 4.2.3 of NFPA 30, can be classified as per NFPA 30 section 4.3.1. The table below is an extract from NFPA 30

Combustible liquids, as defined in section 3.3.33.1 and 4.2.2 of NFPA 30, can be classified as per NFPA 30 section 4.3.1. The table below is an extract from NFPA 30

This is the lowest temperature at which a hydrocarbon liquid (petroleum products) will give out sufficient vapour in the air near the surface of the liquid. The vapour can ignite on exposure to open flame. The flashpoint is used to indicate how flammable a liquid is. Below the flashpoint, the liquid does not generate enough vapour to support combustion.
As defined in section 3.3.20 of NFPA 30, the fire point is the lowest temperature at which a liquid will ignite and achieve sustained burning when exposed to a test flame per ASTM D92 (Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester).
Storage facilities are mostly restricted to designated areas. Most times, you find these storage facilities clustered in designated areas guided by local regulations. Generally, it is rare to see a new storage facility been constructed in a built-up area; they are sited at an appreciable distance away from residential areas.
Before any other factor is considered in sitting a storage facility, the safety of the environment and people is the topmost priority. Detailed Environmental Impact analysis of the storage terminal should be performed before the final decision of siting the facility.
Siting a storage facility is mostly dependent on the available market. The storage facility should be located close to the targeted market unless there are restrictions due to regulations.
It is the best decision to locate the storage terminal close to where the highest demand for the products is expected; this will also reduce the cost of transporting the products to the end-users.
In many instances you find clusters of storage terminals close to refineries, these storage terminals store the refined products. It is a wise decision to site these facilities very close to reduce the cost of building long pipelines and associated infrastructures. Note that these storage terminals close to refineries are the primary storage facility for refined products. The products are further transported to other terminals.
Security of storage terminal should be considered in the planning process. Storage terminals should not be sited in hostile communities or places susceptible to war.
Security considerations should not be limited to the storage terminal, but also of the reception facilities and pipelines.
In a situation whereby the security of the facility is not guaranteed, appropriate security must be put in place.
The means of receiving the products is a crucial consideration. Most times, refined products are imported by countries; therefore, in the absence of cross Country pipelines, extensive storage facilities may be built close to reception facilities such as Wharves and Import Berth Platforms.
In The Niger Delta Area of Nigeria, there are clusters of storage terminals close to rivers outward the Atlantic Ocean. By sitting the storage facilities close to water bodies, the cost of building long pipelines is minimised.
Also, the means of evacuating the products is a very crucial consideration that should be critically evaluated. In West Africa countries, Petroleum products are mostly transported by trucks from storage terminals to dispensing stations; therefore, the storage facility should be easily accessible. Locations with bad roads, roads not wide enough should be avoided to eliminate the possibility of an accident resulting from these conditions.
The components of a storage terminal vary depending on the design philosophy of the terminal. Terminals whose products are evacuated using pipelines may be slightly different from terminals that products are evacuated by trucks. Terminals that trucks are used for product evacuation are equipped with loading gantries; this is absent in terminal that products are evacuated using pipelines.
Also, the type of storage tanks in a terminal might be different depending on the products stored.
Tanks are the significant components of a storage Terminal; they hold the hydrocarbon products.
They are the most visible components of a storage Terminal and can be seen from a far distance.
In a facility, there are different tanks including product storage tanks, slop tanks, firewater tanks, portable water tanks and emergency diesel generator fuel storage tanks.
Below is a brief explanation of some of these tanks
These are the main components of a storage terminal; they hold the petroleum product volume until they are evacuated. The type of storage tank is a function of the product, the diameter of the tank, and local regulation.
Selection criteria will be further explained in subsequent sections; however, below are the major types of tanks found in storage terminals.
These tanks are made of a cylindrical steel shell with a permanently fixed roof attached to the top of the shell. The fixed roof may be of dome shape or conical shape. There are also flat roof tanks, but these are rarely used.
For large diameter tanks, fixed roof tanks are used to store liquid hydrocarbon fuel that does not readily vaporise at the storage condition (temperature and pressure).
Like the name the roof is conical in shape, used to store a liquid that does not vaporise easily. The roof is mostly made from carbon steel plate materials supported by rafters and vertical members depending on the size of the tank. All the structural support members are evenly distributed around the tank.
These tanks have a self-supporting roof made from high strength aluminium alloy. They are called Aluminium geodesic dome roof because the roof is made of Aluminium material.
They provide cover for the tank and/or internal floating roof and can be installed on both new tanks or rehabilitated tanks.
In small to medium size tanks, dome roofs are assembled outside the tanks and lifted on top of the tank. While in large diameter tanks the dome roof may be assembled inside the tank and lifted to the top of the tank.
The choice of assembling the roof outside the tank also depends on available space beside the tank.

Figure 2: Tanks with Aluminium Dome Roof

Figure 3: Assembling of Dome Roof inside the Tank
The roof of these tanks floats (rise and fall) with the liquid, instead of been permanently fixed to the top of the shell. A seal is installed between the roof and the shell to prevent foreign materials (water etc.) from entering and contaminating the product.
In floating roof tanks, there is usually limited vapour space between the roof and the product. Vapour only exists when the liquid level is very low, i.e. lower than the height of the support legs of the floating roof. This only occurs when the roof legs lands on the tank bottom, and more products are evacuated from the tank.
Some of the advantages of floating roofs tanks over the fixed roofs are
Major disadvantages of floating roof tanks are:
Two types of floating roofs are used as explained below:
These type of tanks has the roof seating on the product on an open-top tank. The roof will almost be at the top of the tank when the tank is filled while it is at the bottom of the tank at a designated height above the inlet and outlet nozzles when the tank is empty. These types of tanks are very prominent in storing volatile petroleum products; however, in recent times, they are mostly changed to internal floating roofs.
The roof of an external floating roof tank is mostly double deck to provide double protection for the liquid, aid buoyancy of the roof, minimise the chances of a single deck roof been stocked in small diameter tanks, and also to reduce the risk of fatigue cracking in large diameter tanks in areas with strong wind.

Figure 4: Inside View of an External Double Deck Floating Roof Tank

Figure 5: Outside View of External Floating roof Tank (No Roof Cover)
These types of tanks have the floating roof installed inside a fixed roof tank. The tanks are mostly covered with an aluminium geodesic dome roof.
The internal roof is most time a single deck made of very light aluminium material.
Slop tanks are smaller compared to “Products Storage Tanks”, they are used to store products that are suspected to be contaminated.
They are made from carbon steel plates shop fabricated, or field erected depending on their size.
The products transferred to the slop tanks are those from drain lines, interface products received from pipelines, etc.
Slop tanks may be horizontal or vertical. Also, there might be more than one slop tank in a storage facility. There may be dedicated slop tanks for different interface products received in a facility.
Usually, the products in the slop tanks are allowed to settle and separate into layers before it is further transferred to the respective storage tanks.
Fluid separated in Slop tanks are taken to the laboratory for analysis before they are further transferred back to the tanks.

Figure 6: Two Small Slop Tanks
The firewater tank is used to store firefighting water. The tank is installed at a location outside the process area. In some instances where water from the open sea is utilised, the firewater tank will be smaller in size compared to when firefighting is solely dependent on the tank.
The main firewater pumps are part of the safety system of the facility; they are used to pressurise and deliver the quantity of water required for firefighting.
Minimum two numbers of firewater pumps should be installed in a facility.
The pumps should be located under a shelter (Pump House). Usually, the sparing philosophy should be at least N+1 (N= number of pumps running, one on standby). The pumps should be located away from the process area in a non-hazardous location close to the firewater storage tank. If the pumps take suction from an open-source river, the elevation of the pump should be well determined to prevent the pumps from cavitating.
In most facilities there are both electrically driven firewater pumps and diesel-driven pumps, this is to guard against power outage if only electrical pumps are installed.

Figure 7: Diesel Driven Firewater Pump
Since it is not economical to continuously run the main firewater pump, jockey pumps are installed along with the main firewater pumps. Minimum two (2) jockey pumps should be installed in a facility. Their primary function is to keep the firewater ring main pressurised. Jockey pumps are specified to a maximum head they can deliver. In some cases, the jockey pumps run continuously while in other cases they run intermittently.
When the pumps run continuously, the jockey pump is equipped with a bypass line fitted with a pressure relief valve. When the pressure generated by the pump reaches the set point, the relief valve opens, and the water recirculates back to the storage tank.
When they are installed to run intermittently, the jockey pump is instrumented and comes up when the pressure in the line drops below a set point. The pressure drop, in this case, is not the large pressure drop experienced when a firewater monitor or hydrant is started during firefighting. In this case, the firewater ring main has pressure transmitters installed that communicate the jockey pump to start when there is a minor pressure drop to fill up and pressurise the line.

Figure 8: Electric Motor Driven Jockey Pump
These pumps are used to transfer fuel products from the receiving facility to the storage tank, from one storage tank to another, or to evacuate products from storage tanks to the customers. The number of pumps depends on the products stored in the facility; however, a minimum of two pumps (one (1) running, another on standby) should be installed for each product.
The pumps for receiving products may be different from those to evacuate products from the facility. This depends on the size of pumps required to receive and evacuate products.
The product transfer pumps should not be installed in the same shelter as the firewater pumps. Fire suppression and the fighting system should be installed in the pump house and around the pump house.
Piping are the “arteries” of a storage Terminal connecting different components of the facility.
They are utilised for every operation that entails product transfers. Activities such as product reception, inter-tank transfer of products, and product evacuation are made possible by piping.
Pipe manifold may be installed at an appropriate location for easy diversion of flow to designated tanks. The manifold is mostly used to split products from a single source to different tanks or commingle products from different tanks into a single pipe. They are also used to achieve inter-tank transfer as well as interline transfer.

Figure 9: Product Reception Manifold
Valves are devices used to regulate, direct, or control the flow of a fluid. In storage terminals, valves are installed at an appropriate location such as inlet nozzles to tanks, manifolds, and locations where isolation or product control is required.
The most common valve in a storage terminal is the gate valve.
Gate valves are mostly used in storage terminals because they offer low flow resistance and can handle fluid with solid particles and high viscosity. They are very rugged.

Figure 10: Gate Valves Installed in Storage Terminal
The separator is a critical component of a storage terminal because it helps to protect the environment from pollution. In a terminal, if liquid hydrocarbon spill on the ground and it rains, then these mixtures are transported to surrounding water bodies. To prevent pollution, all facility drains in areas with potential spills are channelled to the oily water separator. The free oil is skimmed and filtered out of the water. The water should be further treated before it is discharged out.
Electricity is crucial in the operation of a petroleum storage terminal. In developed countries, the electricity supply is guaranteed; however, in developing countries, the electricity supply is a significant problem. A backup electricity generator should be provided in areas with a guaranteed electricity supply. Facilities sited in locations with insufficient electricity supply should have a minimum of two electricity generator (one running, and the other on standby)
The generators should be located in a non-hazardous area away from the process area.
The building should be located in a non-hazardous area away from the process area. Offices of personnel working in the terminal are located in this building except for those performing operations related tasks. Canteen and other utility activities may also be performed in the building or performed in another separate building.
The control room is the driver of the facility. Most storage terminals are automated or semi-automated. In automated facilities, tank volumes are displayed, operating of valves and pumps are also performed from the control room.
The control room communicates with all field instruments such as temperature sensors, pressure indicator transmitters, flow meters, and initiates appropriate actions.
Loading facilities are used for receiving products into the storage terminal. They may not be directly located at the storage terminal.
Facilities not receiving products from pipelines connected to refineries have this facility located at jetties, train stations, or wharves were sea vessels offload their products. The loading facility is connected to the terminal via a pipeline.
Unloading facilities are used for evacuating products from the storage terminal.
In some cases, the products are evacuated using pipelines, while they may be evacuated using trucks in other instances.
A loading gantry is required to load products into the truck.
The loading gantry is an assembling of steel structures and products unloading facilities. There is an elevated platform installed; the operator stands on the platform and directs the loading arm to fill the trucks.
The loading gantry should be equipped with flow meters to measure the volume of products transferred into the trucks.

Figure 11: Vessel Offloading Petroleum Product

Figure 12: Loading Gantry
The selection of the type of storage tank is dependent on several factors including
A general rule of thumb used in selecting the type of storage tank is
There are company-specific requirements in selecting tank type. SPDC has developed some guidelines for selection of storage tank type as shown in DEP 34.51.01.31.
The table below is an extract from SPDC DEP 34.51.01.31. The guideline is based on tank diameter and liquid flashpoint.

There are several factors to consider in selecting optimum tank diameter and height; some of the critical considerations are stated below.
All tanks in a facility should be designed with appropriate safeguards to prevent overfill.
Tank overfill leads to inventory losses, tank damage, environmental pollution and possible fire incidence.
Safeguards to be provided include level indicators, level alarms, level shutdown etc.
Overfill protection of tank guideline is stated in API 2350
In a typical storage terminal, there are minimum four (4) types of piping including products piping firewater piping, portable water piping and Utility piping.
Refined products are non-corrosive. Therefore, carbon steel piping material is mostly used. Carbon steel pipes mostly used include ASTM A106 Gr. B or C. API 5L. Glass Fibre Reinforced Plastic (GRP) pipes can also be used.
Depending on the cleanliness of the water utilised for firefighting, various materials may be utilised for firefighting. Galvanised carbon steel pipes used to be the dominant material; however, the use of HDPE pipes and GRE pipes are becoming more prominent due to their higher resistant against corrosion.
Galvanised carbon steel pipes are ubiquitous for these applications; however, GRE/GRP pipes are becoming very pronounce because they offer more resistance to corrosion and chemical attack.
As per SPDC requirements stated in section 4.1.2 of DEP 39.01.10.12-Gen, there is a preference to the use of non-metallic piping for portable water piping. Also, there is a temperature limitation for galvanised carbon steel compared to GRP pipes. The maximum applicable temperature for galvanised pipes is 60oC while GRP pipes can be used for application up to 100oC
Carbon steel piping is used for dry instrument air piping; however, when the air is wet consideration should be given to GRP and stainless steel pipes. Also, internally lined carbon steel pipes can be used for a wet system.
GRE/GRP pipes are favoured for Drain/sewage piping.
As previously stated, siting storage is stringently regulated, within the approved locations for storage terminal, there are minimum spacing requirements that must be observed.
The spacing required is a function of the class of liquid and the size of the tank.
Tanks storing flammable liquid hydrocarbons (Class I, Class II, or Class IIIA) shall have minimum spacing as stipulated in Table 22.4.2.1 of NFPA 30. The table below is an extract from NFPA 30, showing the minimum required spacing.

For details of the minimum spacing requirement between storage tanks and line of properties refer to section 22.4 of NFPA 30. Table 22.4.1.1(a) and Table 22.4.1.1(b) gives the permissible spacing for Above-ground Storage Tanks Storing Stable Liquids with internal pressure not exceeding a gauge pressure of 2.5 psi (17 kPa)
All products storage tanks holding class I, Class II, or Class IIIA liquid shall be provided with means to prevent an accidental release of liquid stored in the tanks from endangering facilities and adjoining property or from reaching waterways. This is stated in section 22.11 of NFPA 30.
Spill control can be implemented by meeting the requirements stated in section 22.11.1, 22.11.2, 22.11.3, or 22.11.4 of NFPA 30. Two way of effecting spill control are stipulated in NFPA 30 these are
This entails drainage of the spill from the tank area to a remote location. The drainage route should be designed such that if the fluid is ignited the tanks and adjoining properties will not be seriously exposed. Some of NFPA requirements for remote diking are
This entails building a bund wall around the tank. This is the most common spill control in petroleum storage terminals.
Some of the requirements stated in NFPA 30 as regards open diking include

Figure 13: Open Dike around a Tank
Petroleum storage terminal shall have a functional firefighting system installed. The installed firefighting systems shall be as per NFPA standards or other applicable codes.
Some of the applicable NFPA standards are NFPA 10, 11, 14, 16, 20.
Firefighting system installed in terminals include
These are installed on the tanks around the perimeter of the tanks at the top, pump house, loading gantries and other identified critical locations. The sprinklers work with temperature sensors and a deluge valve system. If the system senses high temperature, the deluge valve system opens, and the sprinklers release water foam mixture.
The system utilises foam and water to put out fire rapidly. The system consists of a ring main that is installed around the entire facility with branches running to strategic locations.
Fire resulting from a liquid hydrocarbon can quickly escalate, however with the use of foam, the fire can be easily put off. The foam forms a barrier between the air and the fuel, thereby putting off the fire quickly.

Figure 14: Foam Lines to Tanks
The monitors are connected to the ring main and the foam system. The monitors should be selected and installed such that they can provide appropriate coverage for all the tanks from all angles. The reach of the monitors should be checked against the maximum height and distance of the target tank. Also, the effect of wind on the water/foam jet should be considered in selecting monitors.

Figure 15: Testing Fire Monitors (Water and Foam Mixture)
The fire hydrants should be installed at strategic locations in the terminal; they are source points for connecting firefighting hose.

Figure 16: Fire Hydrant
In addition to all the main fire monitors and hydrant, a fire truck may as well be provided to provide backup for firefighting most especially locations that monitors and hydrants are not installed.

Figure 17: Fire Fighting Truck
Despite the installation of the firefighting system, fire extinguishers should be located in appropriate areas including loading gantries, pump house etc. they provide a quick way of putting off a fire that has not escalated. Dry Powder type extinguishers are the most applicable.
API 650: Welded Steel Tanks for Oil Storage
API 2350: Overfill Protection for Storage Tanks in Petroleum Facilities
ASME B31.3: Process Piping
DEP 39.01.10.12-Gen: Selection of Materials for Upstream Equipment (Amendments/Supplements to ISO 15156:2015)
Department of Petroleum Resources Depots Guidelines: Procedure Guide for the Construction and Operation of Petroleum Products Depots and Facilities
DEP 34.51.01.31-Gen.: Vertical Steel Storage Tanks – Selection Design and Construction (Amendments/Supplements to En14015
EN 140155: Specification for the Design and Manufacture of Site Built, Vertical, Cylindrical, Flat-Bottomed, Above Ground, Welded, Steel Tanks for the Storage of Liquids at Ambient Temperature and Above
NFPA 10: Standard for Portable Fire Extinguishers,
NFPA 11: Standard for Low, Medium-, and High- Expansion Foam
NFPA 14, Standard for the Installation of Standpipe and Hose Systems.
NFPA 16: Standard for the Installation of Foam-Water Sprinkler and Foam-Water Spray Systems,
NFPA 20, Standard for the Installation of Stationary Pumps for Fire Protection, 2010 edition.
NFPA 30: Flammable and Combustible Liquids Code
The fire protection system can be divide into three fire fighting philosophies: Fire suppression, Fire extinguishment, Fire control.
Fire control
Limiting the fire’s size by distributing the water to decrease the heat and prevent a fire from spreading very rapidly across a gap because of intense heat (Flashover), which the sprinkler systems do to cool the fire before it reaches the flashover point.
Fire Extinguishment
Discharging of the fire suppression system ensures no combustion after the fire event.
Fire Suppression
The sharp reduction of the rate of heat release of a fire and the prevention of regrowth.
THE IDEOLOGY OF FIRE SUPPRESSION SYSTEMS.
Fire suppression systems is a broad field that contains many different engineered categories with different ideologies. They are all gathered to build a system to extinguish fires through various types of applications and substances and is difficult to define unless determining the type of hazard and its environment.
To choose the ideal fire suppression system for your needs depends on various factors. While all can suppress a fire, each system has its pros and cons, including various cost levels. A fire suppression expert is needed to select the correct solution.
A fire suppression system has components that combine to detect fires at the fire outbreak through warning signals such as heat, smoke, and other detection devices. These are attached to an alarm system that will alert at fire detection and initiate sequential and consecutive steps to suppress the fire. The fire suppression system will automatically release an external substance’s application to extinguish the fire after the detection alert. The fire suppression system also has a manual application to reduce the time between the alert stage and the external substance release to extinguish the fire.
FIRE SUPPRESSION SYSTEMS CLASSIFICATIONS
The halocarbon gases are extracted from the atmosphere and blended to use in clean agent systems. These gases work to extinguish the flames by absorbing so much heat from the flames that the flames become chemically unstable. They discharge within ten seconds into the hazard space and reach a concentration rich enough to extinguish the fire after another ten seconds. The Halocarbons gases have some familiar names:
Chemical Clean Agents FM-200 (HFC-227ea), ECARO-25 (HFC-125), FK-5-1-12 (3M Novec 1230) Fire Protection Fluid, and others. All of these types offer fast-acting fire-suppressing. Clean agents protect areas, such as computers, servers, electronics, artwork, archives, etc. Compared with traditional water sprinkler systems, clean agent systems act faster and safer than water, limiting damage and downtime.
The quantity of halocarbon agent required to achieve the design concentration shall be calculated from the following equation NFPA 2001:
W = V/S (C / 100-C)


Inert gases include nitrogen, argon, and sometimes carbon dioxide, or a combination of two or more. Inert gases reduce oxygen concentration levels primarily to a point where combustion cannot be sustained and are safe for both people and the environment.
The reducing oxygen concentration in inert gas systems does not go below 12% oxygen inside the hazard area, giving people enough time during a discharge to exit safely. These systems have a more extended discharge time, around 60 to 120 seconds, and it has lower discharge pressure inside the hazard area to prevent causing a problem with room integrity.
Inert gases are highly cost compared to the halocarbon family of gases because inert gas systems have longer retention time and produce no fogging during discharge. Inert gas systems take up more floor space and more physical steel in the system. Because of more tanks and more valves than halocarbon systems.
X=2.303 x (S0/S) x log10 (100/100-c)

SAFETY AND DESIGN CONCERNS FOR CLEAN AGENT SYSTEMS
The engineering designers take room construction as the first element to achieve occupancy and equipment’s best protection levels. They measure and study the construction zone to ensure few leaks paths for the gas to escape quickly. Also, limiting leaks during the peak pressure wave of the gas discharging into the room and predicted hold time of clean agent discharge.
The peak pressure created in an enclosure depends on many factors: the agent concentration and discharge time, humidity, opening characteristics of the system discharge valve, and the aggregate vent area of the enclosure.
The most influential parameter is the aggregate vent area, which comprises all openings, whether unintentional or intentional.
Pressures are developed within an enclosure during the discharge of both inert and halocarbon clean agents.
The discharge of the inert agent results in only a positive pressure change

An Actual IG-541 60-Second Discharge Showing Peak Pressure.
On the other hand, the discharge of a halocarbon agent usually creates an initially negative pressure change, followed by a positive pressure change.

An Actual HFC-227ea Discharge Showing Peak Pressures.
These considerations mentioned earlier will help reduce the number of piping runs to nozzles, located at the ceiling of space, to arrange and distribute the gas systems into the hazard space. The system has an electrical component that must be considered, which is the releasing fire alarm system – it includes the control panel, detectors, notification devices, and the abort switch. To locate the agent cylinders inside the protected area that will achieve the lowest installation and piping cost for the systems. Suppose the hazard zone has area similarity with the same volume. In that case, that is the other to reduce the cost by using one bank of tanks with selector valves that directionally route that gas to whichever zone has the fire and requires the gas.
Engineers take the concentration for the systems as a serious safety concern. Because the clean agent systems are volumetrically designed and have a specific amount of agent for the volume, if the hazard area gets bigger and not putting the proper specific amount of gas, then it will not achieve that extinguishing concentration to suppressed the fire. And if the amount of concentration goes up to the specific amount of gas, then it will cause a problem for human safety.
The halocarbon agent and inert gases are considered to be the most environmentally friendly clean agent systems if it is appropriately designed.
KITCHEN FIRE SUPPRESSION SYSTEMS APPLICATIONS
All cities around the world has restaurants and clubs catering to their people. Numerous fast-food chain restaurants, food courts, hotels and stores. And where there is hot food preparation, there is the potential for fire. Modern cooking requires deep fat fryers, broilers and grills, and there is always the risk of severe fires. Until the mid-20th century kitchen fires were not uncommon and restaurants would burn to the ground before the flames could be contained and suppressed. This problem was not successfully addressed until 1962 – it was then that the manufactures and scientists in fire suppression introduced a system specifically for commercial kitchens that would automatically detect and suppress a fire in the cooking area. This initial effort was a major success and brought the restaurant safety to a new, acceptable level. But the fire suppression system engineers were not satisfied with this initial effort and wanted more improvement. Soon they introduced the wet chemical agent system with the formula K2CO3 that has become the industry standard for restaurant fire suppression around the world.
There are two system design options:
The primary is an appliance specific design where nozzles are aimed at specific hazard areas of the appliance, which is considered the most economical design because the agent is aimed only where it is needed.
The other option is overlapping appliance protection in this design scheme the nozzles are installed in a straight line and provide overlapping discharge patterns – using this layout appliances can be moved or replaced. As long as they stay within the fire-free zone, they will be protected.
In the event of a fire, the fusible link detection system responds rapidly to the growing heat, and when the temperature rating is exceeded, the fusible link separates. This triggers the release of a compressed gas cylinder (pre-filled with the extinguishing agent and charged with dry nitrogen to a pressure of 225 psi at a temperature of 70 F) within the release mechanism. Simultaneously, the compressed gas pressurizes and selects the agent tank and an air cylinder that trips the mechanical gas shutoff valve. The agent is then dispersed throughout the system, rapidly knocking down the flames – and because it has a neutral pH factor, it helps prevent fire reflash. The agent creates a foam blanket that inhibits the release of flammable vapors and cools. After system discharge, the valve assembly must be rebuilt to ensure proper future operation.
The hazard area, in certain instances, may be necessary to discharge the system manually by a remote manual pull station. This pull station is made out of a rigid red moulded composite material which makes it easier to recognize as the manual means for fire suppression system operation.
To provide maximum assurance for suppression systems that will operate effectively and safely must be performed according to the following codes:
NFPA 96 (Standard for the installation of equipment) and
NFPA 17A (Standard on Wet Chemical Extinguishing Systems)
AEROSOL FIRE-EXTINGUISHING SYSTEMS is a part of the fire suppression systems that can automatically operate and extinguished the fire within seconds, through removing the heat. This system used to protect hazards within specific limitations of applications and per their listing.
The aerosol is economical to fire extinguishing and easy to install, and generators after discharge are easy to resume within a short time as no pressure cylinders or piping is required.
Aerosol units consist of non-pressurized generators and contain a solid compound that, when activated, produces an ultrafine cloud of condensed aerosol that chemically extinguishes fire without any harmful effects.
These units are sealed in stainless steel canisters and wired to a control panel mounted to walls and mechanical heat-detecting actuators are also positioned inside electrical cabinets for localized fire protection, visual and audible alarms and smoke detector, these smoke detector is attached to a fire alarm control panel.
When a small fire starts inside the electrical cabinets, the smoke will release into the room and quickly be detected by the aspirating smoke detector which signals to the control panel and triggers the horn and stroke as the fire continues to grow. Several continents units in each of the cabinets are then actuated. Thermal switches are triggered, sending a signal to the control panel which initiates full room fire suppression. A second horn and strobe go off giving a 30-second warning of a total flooding event – all the wall-mounted units discharged into the room the aerosol clouds remain active to reduce the risk of flashover or re-ignition. After 10 minutes, the room is vented out, leaving little residue and no toxic or harmful.
DESIGN CONCERNS FOR AEROSOL SYSTEMS
In the design of a total flooding system, the integrity of the protected enclosure must be considered, and to prevent loss of agent through openings to adjacent hazards or work areas; openings must be permanently sealed or equipped with automatic closures.
Forced-air ventilating systems must be shut down or closed automatically where their continued operation would adversely affect the performance of the fire-extinguishing system or result in the propagation of the fire.
The volume of the ventilation system and associated ductwork must be considered part of the total hazard volume when determining the quantity of the agent.
The protected enclosure must have the structural strength and integrity necessary to contain the agent discharge.
If the developed pressures present a threat to the structural strength of the enclosure, venting shall be provided to prevent excessive pressures.
To determine the Quantity or The mass of an aerosol-forming compound required, calculated from the following formula:
m = da x fa x V

Aerosol fire-extinguishing systems can be used in Marine Systems to protect hazards that are partially or enclosed or equipment that is partially or enclosed on vessels with specific Design requirements.
Health Effects.
Are these systems safe? To determine the health effect of using this system in spaces that are occupied or unoccupied, it depends on the evaluation of the potential adverse health effect from the engineering sides by assessed for the density, size of the particulates. And the concentration of gases expected after actuation of the aerosol extinguishing system at the design application density.
For Marine Systems
In these specific applications, the particles of the powdered aerosol fire suppressants must be 10 µm for maximum effectiveness. This size of Particles can be inhaled and can give potential exposure to the respiratory system. For humans size 5 µm to 30 µm of these particles can be deposited in the nose and throat region (nasopharyngeal). Powdered aerosols are typically composed of multiple soluble and insoluble compounds. As such, acute inhalation exposure to very high concentrations of these compounds can induce a variety of adverse effects in humans. Therefore, a limited battery of toxicity tests is required to determine the appropriateness of the powdered aerosol system for use in occupied spaces.
Aerosol Potential Effect on Visibility
The visibility is an essential factor to escape a fire hazard when powdered aerosols fire extinguishers are used for occupied spaces. It is essential to have data on the aerodynamic properties of the powdered aerosol, and that is the mass median aerodynamic diameter (MMAD), These values are necessary to determine where the particles can deposit within the airways of a rodent model and in a potentially exposed to a human.
To ensure that powdered-aerosol products will meet the visibility requirements of the appropriate organizations, several methods and models based on the standard visual range formula and Mie theory.
Lv = 1200/c

Or Calculations resulting from the Mie scattering visibility model
That indicates visibility of 1 m or more can be achieved by increasing the MMAD particle size

Mie Scattering. (Source: Friedlander, Smoke, Dust, and Haze: Fundamentals of Aerosol Dynamics)
Aerosol systems must be performed per NFPA 2001 (Standard on CLEAN AGENT FIRE EXTINGUISHING SYSTEMS) and All wiring systems shall be installed per NFPA 72.
Carbon Dioxide (CO2) FIRE SUPPRESSION SYSTEMS Provide large presentations of concentration gas that reduces the oxygen level to a point where combustion cannot occur. CO2 Systems is unsafe for people. The CO2 system will extinguish fires in Class A, B, and C hazards, and are only recommended for localized applications or areas generally inaccessible by employees or customers.
CO2 is a colourless, non-electrical conductive and odourless gas that does not leave any residue after discharge. This means there is no damage to the equipment placed in the protected space.
The CO2 system consists of a cylinder (container of the gas quantity pressurized with 3000 psi) with valve assembly. The valve opens automatically when the actuation pressure reaches 100 to 110 psi.
Head Valve with solenoid valve can be used as the head of Master Cylinder Head Valve. The head valve can be actuated by two methods of operation, Electric (solenoid actuator) or Manual ( Mechanical actuator). The cylinder has connected the pipe network through flexible hose connections and the discharge nozzle attached directly to the pipe network.
These mechanical components of the CO2 system come with an alarm system and detection devices attached to a fire control panel. When the fire initiates, the smoke and heat detector devices will transfer a signal to the control panel that there is a fire. The solenoid then automatically opens and release the agent to suppress the fire – as well as the pressure switch, which activates the audible and visual devices.
The CO2 Systems can either be used in a Local Application System or a Total Flooding System.
Local Application System. A system consisting of a supply of extinguishing agent arranged to discharge directly on the burning material and surface fires in flammable liquids in non-enclosable areas or where the enclosure does not conform to the requirements for total flooding.
Total Flooding System. A system consisting of a supply of carbon dioxide arranged to discharge into and fill to the proper concentration, an enclosed space, or enclosure around the hazard.
Common areas where CO2 fire suppression systems installed include electrical hazards, record (bulk paper) storage, ducts, covered trenches, fur storage vaults, dust collectors, combustible materials area.
The design based on volume consideration with specific flooding factors for each space and the minimum design CO2 concentration can be different between hazards and must be compatible with NFPA 12

SAFETY AND DESIGN CONCERNS FOR CO2 FIRE SUPPRESSION SYSTEM
CO2 can cause asphyxiation in humans if the concentration reaches 7.5%, that’s why the systems are designed to have a pneumatic siren that warns people to exit hazard areas where the CO2 will be discharged from the suppression system. The pneumatic siren is one of the life safety devices.
CO2 Systems are dangerous. It is essential for people around the hazard protected by CO2 Total Flooding System to be trained on the dangers of this system and how to evacuate safely if the system is preparing to discharge and suppress the fire.
The CO2 concentration, in most cases, are designed to be 34%, but it can be more dangers, when it’s used to protect areas such dry electrical hazards 50%, Record (bulk paper) storage, ducts, covered trenches 65%, and Fur storage vaults, dust collectors 75% as a minimum design CO2 Concentration.
WATER MIST FIRE SUPPRESSION SYSTEMS
Water mist systems are a fixed fire protection system that automatically uses water to suppress or extinguish a fire by producing ultra-fine water droplets. It used 50 to 90% less water than a traditional fire sprinkler. Water mist systems may be connected to a building’s water supply for continuous fire-fighting capability, or in remote locations, may be connected to a tank or reservoir.
Water mist systems help provide effective cooling and fire control on Class A fires, or assistance with extinguishing and preventing re-ignition on Class B or Class F fires.
The system consists of automatic nozzles with a heat-sensitive quick response glass bulb attached to a piping system and connected to a water supply that’s used to actuate the water. In the event of a fire, the nozzles discharge a cone of spray containing small water droplets that fill the protected zone with water mist.

Droplet Size Measurement Locations.
The Water Mist Systems can be installed as
Wet Pipe Water Mist System. A water mist system using automatic nozzles attached to a piping system containing water and connected to a water supply so that water discharges immediately from nozzles operated by the heat from a fire.
Dry Pipe Water Mist System. A water mist system using automatic nozzles attached to a piping system containing air, nitrogen, or inert gas under pressure, the release of which (as from an opening of an automatic nozzle) allows the water pressure to open a dry pipe valve. The water then flows into the piping system and out through any open nozzles.
Pre-action Water Mist System. A water mist system using automatic nozzles attached to a piping system that contains air that might or might not be under pressure, with a supplemental detection system installed in the same areas as the mist nozzles. The actuation of the detection system opens a valve that allows water to flow into the piping system and discharges through all opened nozzles in the system.
Deluge Water Mist System. A water mist system utilizing non-automatic mist nozzles (open) attached to a piping network connected to the fluid supplies through a valve controlled by an independent detection system installed in the same area as the mist nozzles.
Local-Application Water Mist System. A water mist system is arranged to discharge directly on an object or hazard in an enclosed, unenclosed, or open outdoor condition.
Water Mist Droplet Size Characterization and Measurement
Most successful use of water mist fire protection systems is the increased surface area per unit water volume afforded with the generation and application of small droplets. The increased surface area dramatically increases the rate of heat transfer from the fire to the water mist droplet, cooling the combustion reaction and diluting the oxygen concentration with the generation of water vapour in the vicinity of the fire. It is important to characterize the droplet size distribution produced in listed nozzles for use in the future design and application of water mist systems. It will be valuable in assessing the ability of water mist droplets to control, suppress, and extinguish fires of all types and sizes.

Flow Rate per Unit Area Weighted Droplet Size Distribution.
For Low-Pressure System The Hydraulic calculations for water mist systems with working pressures not exceeding 12 bar (175 psi) and having no additives shall be permitted to be performed using the Hazen–Williams calculation method.

High-Pressure System. A water mist system where the distribution system piping is exposed to pressures of 34.5 bar (500 psi) or greater.
Intermediate Pressure System. A water mist system where the distribution system piping is exposed to pressures greater than 12.1 bar (175 psi) but less than 34.5 bar (500 psi).
Low-Pressure System. A water mist system where the distribution piping is exposed to pressures of 12.1 bar (175 psi) or
The Pressure Loss in Intermediate and High-Pressure Systems


Hydraulically designed to deliver the water flow requirements per the manufacturer’s listing and the provisions of NFPA750.
NFPA750 Standard on Water Mist Fire Protection Systems
FOAM EXTINGUISHING SYSTEMS Are commonly use for protecting high-risk areas, particularly in the fire categories A and B, and mostly used for flammable liquids and combustible liquids in tanks or processing areas to prevent or extinguish fires by excluding air and cooling the fuel. The foam system is, either low expansion foam or medium-high expansion foam systems.
The foam fire suppression is a foam concentrate AFFF, water, and air. When these three ingredients are mixed, these can create a foam solution and forming air-filled bubbles formed from aqueous solutions with lower density than the lightest flammable liquids.
Foam concentrates protein foam concentrate diluted with water to form 3% to 6% solutions, only used for crude oil fires.
Fluoroprotein foam concentrate is similar to protein foam concentrates diluted with water to form 3% to 6% solutions and deposit vaporization preventing film on the surface of liquid fuel. It is used for crude oil or refined oil products where a higher degree of protection is preferred.
Aqueous film-forming foams AFFF concentrates used to produce foam to solution volume ratios from 20:1 to 1000:1 and are used for local protection and engine room.
FOAM SYSTEM CLASSIFICATIONS:
Low expansion foam. Small foam bubbles discharged through sprinkler systems, fire hoses, monitors, spray nozzles, and foam makers. Used for flammable liquid storage, fuel storage tanks.
Medium Expansion Systems are primarily used for vapour suppression in refineries and chemical manufacturing areas.
High Expansion Systems Large foam bubbles, preferred for total flooding of a hazard area or large area volume protection is needed. The most common applications used for aircraft hangars, total flooding warehouses, and Liquefied Natural Gas dock.
Foam systems components
System Tanks can be pre-piped vertical or horizontal and Foam pump skids.
Proportioning Devices releases the proper amount of concentrate into the water supply based on the solution required.
Discharge Devices
Foam discharge devices. Can be water sprinkler nozzles compatible with foams, monitors, foam makers, handline nozzles, and High expansion foam generator.
The piping network connecting the foam discharge devices to the System Tanks.
Alarm systems with detection devices (thermal detectors or quick-response flame detectors), sounding alarms, and electric control panel.
The foam fire suppression systems, in the event of a fire the detection devices will signal the control panel, the valves will open. The foam systems will be actuated to flow the water into the piping system, and the proportioning devices inject the foam concentrate into the water. These will generate foam solution discharging through the discharge devices to suppress the fire by separating the liquid fuel from the air.
Calculation
The minimum rate of discharge or total generator capacity shall be calculated from the following formula:
R = (V/T+Rs) x CN x CL

R= S x Q

Expanded foam velocity also can be calculated by using the following formulas:
Velocity (ft/sec) = Expanded foam (gpm)/KA


Foam Velocity vs Pipe Size
Foam systems must be performed per
NFPA 11 (Standard for Low-, Medium-, and High-Expansion Foam) and
NFPA 1050 (Foam Chemicals for Fires in Class A Fuels).
THE WATER AS FIRE EXTINGUISHING AGEN, THAT KNOWN AS SPRINKLERED SYSTEMS
This type of system can perform well to extinguish the fire. The system discharges the water with specific density in area occupancies that have light, ordinary and extra hazards. It can be used in a wide range of facility depending on the hazard classifications.

The system consists of a head discharge sprinkler with rated temperature indicated by colour coding for its glass bulb and detriment by sprinkler k-factor based on ceiling height.
Water pumps to deliver the water from tanks into the sprinkler’s head through the piping network.
The Piping network, either pressurized water or nitrogen and controlled by gate valves.
Type of Sprinkler Systems
Wet sprinkler systems – the sprinkler attached to a piping network contains pressurized water. When a fire ignites, the heat will rise to break the glass bulb of sprinklers due to thermal expansion for the mercury inside the bulb and the water immediately discharge to extinguish the fire before it spreads.
Dry sprinkler systems – the sprinkler attached to a piping network contain pressurized air or nitrogen. When a fire ignites, the sprinkler will open and the air release to decrease the pressurized water at the dry valve, and it will open to flow the water into the fire hazard.
Pre-action Sprinkler systems – the sprinkler attached to a piping network contains air, either pressurized or not pressurized. The system is attached to the detection system when a fire ignites, and the detection system will be activated and signal the control panel to open the valve. The water will flow to extinguish and stop the fire from spreading.
Deluge Sprinkler system sprinklers with an open head attached to a piping network and the valves are opened by the operation detection system. When the system activated, the water will discharge from all sprinklers attached to the system.
Water sprinkler systems must be performed per:
NFPA 13 (Standard for the Installation of Sprinkler Systems).
NFPA 13D (Standard for the Installation of Sprinkler Systems in One- and Two-Family Dwellings and Manufactured Homes).
NFPA 13R (Standard for the Installation of Sprinkler Systems in Low-Rise Residential Occupancies).
NFPA 20 (Standard for the Installation of Stationary Pumps for Fire Protection).
In conclusion, to successfully extinguish or suppress fires, you have to apply as follows:
Passive fire protection:
An architecture engineering methodology that divides the building and facility into separate sections and prevents the spread of fire through the use of fire-resistance-rated walls and floors. Using fire doors to help these separated sections of the structure and to prevent the spread of fire and smoke throughout the ducts of the building. Or to use multiple floors is path markers. These markers assist in the evacuation process by lighting the way through the dark in case of fire spreading.
Active fire protection:
A methodology which intends to suffocate the oxygen, restricting the fire and cooling down the fire.
Suffocating the oxygen by using gas or foam systems.
Restrict the fire to cut fuel supply or remove combustible materials.
Cooling down the fire is to using water systems.
The increasing popularity of the Internet of Things (IoT) devices in the field and the continuous advancements of data-gathering techniques have significantly increased the amount of relevant information. The data size usually reaches Petabyte ( = 1024 Terabyte) or Exabyte ( = 1024 Petabyte). Big Data is a buzzword defined as increasing volume, variety and velocity of data (Figure 1) and a concept used to describe an immense volume of both structured and unstructured data that is so large it is difficult to process using classic software techniques and databases.

Figure 1. Source: https://algorithmia.com/blog/wp-content/uploads/2020/03/image2.jpg
The entire Big Data processing structure is set up in a manner that allows large volumes of information to be processed and recovered more quickly and easily than a conventional database, which stores various information fragments in different locations, merging the information into a single report as needed. Big Data analytics is far more efficient than that, and, for others within this area of knowledge, it is in fact access to large volumes of divergent kinds of data, which are then fed to machine learning algorithms to discover unidentified relationships [1].
With the rapid development of technology and industry, Big Data is a popular strategy now, and it has become a link for different disciplines. Making the most out of data is a key part of successful financial performance for an energy firm. However, Big Data has traditionally been regarded by the oil and gas industry as a term used by “softer” industries to track people’s behaviours, buying or political tendencies, interests, etc. As a consequence, the promotion of Big Data technologies in oil and gas lags behind other sectors. We can suspect the main reason behind this phenomenon is that the connected services and networks associated with its deployment raise many questions surrounding areas of cybersecurity and data privacy.

Figure 2. Google search results for “Big Data” in each industry. Source: https://www.researchgate.net/figure/Google-search-results-for-big-data-in-each-industry_fig2_339808583
Big Data Analytics is becoming one of the critical chapters in the digitalisation of the oil and gas industry. It is about managing and processing an extreme volume of data to improve operational efficiency, to enhance decision making and to mitigate risks in the workplace [2]. Essentially, this process generates more revenue for the industry. But it takes some advanced hardware and software to analyse Big Data properly; these tools allow an industry to evaluate millions of bytes of data for fast conclusions. For instance, Artificial Intelligence (AI) analyses inputs to learn and upgrade its sorting processes over time, using data — generally coming from Big Data Analytics — to provide an accurate diagnosis or a decision-making framework.
AI is the development and application of computer systems qualified for logic, reasoning, and decision-making capabilities. Using visual perception, experience recognition, and language translation, this self-learning technology analyses data and output information in a more efficient way than human-driven methods.
The development of artificial intelligence solutions for the oil and gas industry aims at augmenting and enhancing human knowledge and expertise in exploration and production. Exploration and production have always been technology-intensive and forward-looking into new ways to improve operations and reduce exploration risks, so naturally, it was where the highest demand for AI solutions had been seen. Although the technology was initially approached with curiosity and some degree of scepticism, today most companies have incorporated AI initiatives.

Figure 3. AI architecture in oil and gas. Source: https://bigdata-madesimple.com/wp-content/uploads/2019/02/image1.png
AI tools build fast using either open-source tools like Python or TensorFlow, on the one hand, and APIs, on the other. Of course, AI solutions require significant computing power, and thus, deep learning, neuromorphic chips, and high-performance architecture clouds are progressively being adopted in oil and gas.
Artificial intelligence is a very strategic domain, and there is a consensus that technology is a crucial lever and enabler in unlocking substantial business value. It is truly becoming a business imperative in the industry. Throughout this article, we will see sets of solutions spanning across the energy value chain from exploration to health and safety.
The new generation of wireless networks, the improvements of ubiquitous computing devices, and advanced storage capabilities have been opening more possibilities for real-time applications, such as remote oilfield monitoring. Also, predictions indicate that oil demand will keep rising in the next two decades, which may result in a significant gap in the petroleum supply [3]; this prospect stresses the role of innovation in enhancing the efficiency of the production chain to meet the increasing demand.
Unlike other industries, dealing with large quantities of data is not a new issue for the oil and gas sector. Companies have generated and used a lot of data over the years to study the surface of the earth, logging-while-drilling, monitoring and maintaining pipeline systems, forecasting the price trends of various energy sources, and even understanding the volatility of financial markets. Throughout the whole process, oil and gas companies have compiled a lot of data. But when it comes to new digital technologies, in particular, the sophisticated use of data, the industry is beginning to realise that there are many untapped opportunities. They have yet to take advantage of, and these opportunities could lead to huge potential savings.

Figure 4. Big Data applications in the oil and gas industry. Source: https://ieeexplore.ieee.org/ielx7/6287639/8948470/9028154/graphical_abstract/access-gagraphic-2979678.jpg
Big Data, coupled with AI, is already delivering results and material improvements are being witnessed in several areas. On average, prediction accuracies for either equipment failures or process outcomes improved from 60 or 70 per cent to more than 80 per cent, 20 to 30 per cent of workforce productivity improvements that drove between 5 and 15 per cent efficiency gains and corresponding cost reductions [4]. Likewise, 70 to 90 per cent acceleration achievements are reported in decision-making, especially in knowledge-intensive domains like Geoscience and Engineering.
When businesses start digitising the process of resources discovery and energy distribution, more and more data will be produced and gathered. Energy companies will more and more use big Data to derive more benefit from the upstream and downstream supply chain and increase total productivity and revenue.
As the industry’s focus shifts from production to long-term profitability, more companies are looking to gain deeper subsurface insights from their data and to do so, they must have straightforward access to that data.
One prominent feature of the oiling drilling process is using large and complex data in real-time. Big Data can allow an oil & gas exploration companies to visualise their drilling environment on a computer screen through promptly analysing large amounts of data. This research would then be used to lead instruments such as drills in the best way possible while enhancing the production process by up to 8% [5]. This efficiency upgrade is not something that should be ignored.
As companies drill for oil, they can perform complex calculations on the massive amounts of data, including information, such as the seismic properties of the drilling area or the temperature levels. Knowing all of this information increases the effectiveness of the drilling process in terms of time and money spent.
Seismic interpretation is critical for the success of exploration. It is a knowledge-intensive use case and very dependent on tacit knowledge of geologists. Results of interpretation vary by individual, their knowledge, the context in which the analysis is performed. That makes it an almost perfect case for applying more unbiased systems, which could not only help deliver consistent performance in seismic data interpretation but also provide a log of decisions to know more about the reasons behind specific interpretation outcomes. Having a system that continuously improves its ability to interpret the data under the guidance of experts in a company has been the primary motivation behind building that sort of solution.

Figure 5. Pre-stack seismic data for interpretation and analysis. Source: https://sharpreflections.com/wp-content/uploads/2015/11/force.jpg
Artificial Neural Networks (ANNs) are the machine learning technology used most in the oil and gas industry [6]. They can process vast quantities of data to extract patterns and information that cannot be detected by the human brain. A new wave of decision-supporting solutions, including self-growing and multi-input/multi-output neural networks for rock type prediction and classification, culminated in recent developments in machine learning products. They can train neural network algorithms on input as divergent as pre-stack data and lithology logs, and provide users with qualified “most probable” seismic classification volumes.
For example, Galp, a Portuguese oil and gas company, and IBM have been developing a solution that interprets pre-stack seismic data and describes geological structures and characteristics of those [4]. Notably, the system performs this with the awareness of the geologic context — structural geometry, depositional environment photography — and even more importantly, it takes into account notes from previous investigations. In such a way, it continues building on prior knowledge, which is probably its most important characteristic.
Solutions relying on Big Data are being developed to accelerate prospect identification and to reduce uncertainty when analysing a new reservoir. To do so, a series of machine learning algorithms are applied to identify and recommend missing reservoir properties based on reservoir analogues and sophisticated user interfaces begin to allow advanced visual analysis. In addition to extracting numerical data from analogues, these systems are also extracting relevant geological information from internal and external reports and geological papers.
In the case of Repsol, this tool is analysing over 60,000 reservoir analogues and almost half a million of geological documents [4] and what is more, it allows over 80 per cent faster discovery of relevant Geoscience information. Such an amelioration comes incredibly handy at times where a decision needs to be made quickly about new lease, acquisitions, or expansion. There are strong indications that those capabilities provide a noticeable competitive advantage for oil and gas companies.
A relatively new addition in the Big Data and AI industry toolkit is a heat map for production prospects. It has been developed specifically for unconventional shale operators, and it is used to identify economic production location — the heat map — for acreage owned by an operator. In other terms, there is a solution used to determine the optimal producing well location, potentially driving greater production output from the acreage.
Technically, this type of tool extracts key production parameters from well logs, both conventional vertical wells as well as currently producing horizontal wells, and automatically conducts spatial interpolation. Those key production characteristics are used in subsequent machine learning models that predict production outcomes based on well log data and geology. Well completion specifications can be integrated, not to optimise completion parameters but for recognising the impact of different fundamental completion characteristics on the production volume from the field. These tools are also capable of analysing the yielding capacity at each production layer, so providing a three-dimensional view of the property’s production potential.
Originally, shale sweet spot finding tools were designed to support operators with the acreage they owned. But increasingly they are being applied for acquisitions, where the target acreage — adjacent or elsewhere — is being assessed using its production estimation potential. Sweet spots finders can be deployed very quickly. They are pre-configured by some cloud vendors, and as long as they could either receive the operator’s data, well-log data, or the system itself can access the sources where the data is stored, the solution can be tested immediately. So your users have a chance to see the results. And in terms of deployment, because it is a cloud-based solution, it is much faster than the critical on pram situation. Also, the cost is per usage rather than an initial upfront, which makes it quick and easy to adopt in an operating environment.

Figure 6. Finding sweet spots in shale reservoirs. Source: https://youtu.be/5usnf9twqDY
Analysing fairly sizeable well-delivery documents from a large number of wells informing an operator how to prepare drilling operations is a complex and resource-intensive activity. Big Data and AI can be applied to deal with this amount of data — for example, Woodside reports over 80 per cent efficiency improvements in its operations [4].
Traditionally, each dot representing a well within a graphical user interface had a pile of information associated with it — a technical assistant would get together those documents, print them out, and there would be time for an old-fashioned reading session for the next few weeks. Now, drilling engineers and scientists can just draw a circle on a map, and the work is done: every drilling event for every well in that location is summarised by depth, with unstructured data turned into structured data for further analysis.
Woodside, the largest Australian natural gas producer, established a data science and cognitive intelligence team in 2015. Since then, deep learning artificial intelligence platforms have been responding to queries from its staff, rapidly sifting, sorting, and surfacing decades of data and company knowledge. The company proudly claims to have processed the equivalent of over 600,000 A4 pages through the application of advanced analytics and cognitive computing in their operations. Now, in the words of Woodside’s Head of Cognitive Science, they went from 80 per cent of the time looking for the information and only 20 per cent of the time figuring out what to do about it, to completely flip that equation [7], [8].
Another classic application of machine learning tools to site development activities is drilling; it is to monitor the reliability of operations or processes. Predictive drilling advisors are based on monitoring near-real-time drilling sensors and being able to predict the incidence in a much longer time horizon than the current systems allow, extending it from approximately half an hour to almost two hours. The core of this business solution is about their ability to save millions of non-productive time that results from stack pipe or other incidents.
Weatherford has recently developed a digitalisation solution for well construction optimisation. After acquiring high-resolution data from multiple sources — geological and geophysical data, rig site, offset well databases, and even third party applications — it transfers the data over a secure network to one centralised cloud-based repository. Then, a web-based interface lets drilling experts interact with complex data sets and displays advanced 2D and 3D renderings across numerous wells. Features such as smart alerts, intelligent algorithms, and real-time engineering models support simulating downhole conditions and anticipating hazards.
Using real-time data and technical models, a mix of lift control, fluid optimisation and IoT infrastructure can achieve continuous production improvement. Since modern sensors can instantly detect anomalies and progressions throughout the artificial-lift system, a reciprocating rod-lift pumping unit can now be equipped with an onboard sensory system that is regularly updated by embedded well-engineering models [9].

Figure 7. Components for boosting production autonomously in multiple artificial lift scenarios. Source: https://www.weatherford.com/getattachment/50c1a851-dd89-4e48-83d6-9406d3220a3b/Autonomous-Well-Management-System-Increases-Uptime
The unit will use an information base collected from millions of downhole cards and oilfield simulations and independently determine what improvements can be made to optimise production in response to any fluctuations in production. For instance, if a formation begins releasing additional fluids into a wellbore, this influx will immediately cause the calculations needed to determine the formation of an under-pumped well. A fully automated system can calculate setpoint readjustments and maximise the surge.
In situ recovery is one of only two methods involved when it comes to extracting oil sands and bitumen. The thermal branch processes that are widely used and economically viable are: steam-assisted gravity drainage — or SAGD —, and cyclic steam stimulation, whilst nonthermal recovery methods include vapour extraction and cold heavy oil production. In Canada, for example, the viability of SAGD comes from the fact that most of the deposits are too deep for mining is also too shallow for high-pressure steam injection processes. Despite the commercial success of thermal in situ processes, they present multiple challenges, including substantial water consumption, high-energy intensity, considerable supply cost, and high GHG emissions [10].
Hence, oil sands greenfield operations that use SAGD production method with notoriously difficult geology and limitations to predict the output based on steam input are specifically interested in an optimisation feature. It is crucial for those looking for ways to reduce operating costs and optimise steam to oil ratio, which that feature is ultimately intended to achieve. At some point, digitalised oilfields in this context are already seeing +99 per cent prediction accuracy with the use of artificial intelligence using a hybrid model that is not a typical data-driven machine learning but rather a physics-inspired hybrid. It takes into account thermodynamics, geology, and rendered results of an unprecedented level of precision.
Health and safety is on top of mind of any oil and gas executive and its number one priority to keep operations safe. Data solutions are providing health and safety professionals with the unique ability to go through decades of incident reports and find root causes for similar incidents and mitigation strategies that have been effective in the past. Overall, they can help today’s work on designing policies that prevent incidents and design safer operational practices.
Data analytics and deep learning can therefore enhance the implementation of process safety best practice and improvements to reduce the significant loss of containment risks. During safety investigations, what used to take several days of cross-referencing and searching can now be done in a matter of hours. In other words, a ‘super-computer’ can provide oil and gas personnel with valuable process safety insights at first hand, allowing them to learn from past experiences more efficiently and effectively.
Initially, IBM’s Watson system was primarily focused on cognitive capabilities, which is indeed the ability to comprehend, as we call it, unstructured data in documents or natural speech. But now Watson provides a comprehensive environment that combines machine learning tools and is extensively used to interact with programs and languages like TensorFlow, Python, or any other open-source tooling that most data scientists in the industry tend to use and are familiar with.
IBM’s Watson systems have ingested more than 30 years of Woodside’s health and safety data with a reported 80 per cent reduction in time taken to analyse safety incident information [7]. The HSEQ team receives nearly 10,000 safety alert cards a month at one of their gas plants, manually going through them would take hours, possibly days. What Big Data solutions allow HSEQ to do is analyse the cards to obtain feedback on the permit process, and then provide those insights to site controllers to drive action and improvement almost immediately.
A recent study by the United States Environmental Protection Agency — US EPA — Integrated Risk Information System indicated and increased carcinogenic potential for community exposures to airborne ethylene oxide around facilities using the gas. The ethylene oxidation reaction is exothermic and, if this heat is not released in time, the reaction may be violent. A large amount of heat accumulated may result in threats to human health, loss of assets, or toxic discharges to the environment.

Figure 8. A decision tree algorithm application: Ethylene Oxide Safety and Environmental Protection. Source: [11]
Other solutions already on the market are the “guardian angel devices” that are leveraging sensors embedded in vests or helmets that monitor vitals of field workers and alert them into either unsafe location or unsafe conditions, as well as physical distress that the worker can be in. By doing so, they provide an appropriate and effective way of keeping the oil and gas operations safe. Operators are also keen on putting their cleansed safety data as a seed to encourage community sharing.
Solutions described so far represent work already completed, or that has been done over the last years within the oil and gas industry. But researchers are currently focusing on digital rock, nanoscale flow analysis, and modelling using a combination of machine learning capabilities. At IBM, for example, experts are extracting the geological rock characteristics to create an affordable thin layer that allows conducting pore networks analysis, and several experiments monitoring nano-level flows — something that is poorly described in other primary physics models [4]. Eventually, this would lead to an effective simulation that helps determine the production capacity of a particular geological formation where those nanoflows occur. There is hope on this capability bringing much greater certainty of productions in hard-to-estimate sites.
There is also a so-called “self-adaptive water filtration” application of AI. For instance, within Water Planet’s IntelliFlux software, machine learning is used to analyse continuous data from flow and pressure sensors to determine optimal performance of filtration systems deployed in high-variability water environments for oil & gas [12]. An AI-based software can therefore be used to control membrane filtration, ultrafiltration, nanofiltration, reverse osmosis membranes, and any other filtration media where periodical backwashing, cleaning or regeneration are required. After running a series of demonstrations using waters provided by a group of California oil producers to evaluate treating produced water for potential use in agricultural irrigation, it is now focused on scaling up its business model. Artificial Intelligence-guided adaptive cleaning for membrane and filtration processes are yet expected to make treatment plants more efficient, reliable and economical.
Extracting insight from across this environment is an on-demand job for Data Analytics systems. Engineers are creating personal virtual assistants using simple, natural language voice or text commands. In seconds, these tools can search millions of files for relevant information that might otherwise take days, weeks or even months to find.
Willow, for instance, is an Alexa-like virtual avatar that lets staff interact with all of Woodside’s enterprise systems using natural language voice commands. It will search for all the company’s systems and data reserves, drawing relevant answers from more than 60 years of history. People continue to play a vital role in our cognitive and artificial intelligence work, as Willow learns with each interaction and piece of feedback from staff.
Oil and gas distribution pipelines require monitoring for maintenance and safety to prevent equipment failure and accidents. Monitoring oil and gas pipeline networks requires periodic assessment of the functioning and physical state of the pipes to minimise the risk of leakage, spill and theft, as well as documenting actual incidents and the effects produced on the environment. Drones, also known as Unmanned Aerial Vehicles (UAVs), are emerging as an opportunity to supplement current monitoring systems.
Drone production is growing extremely fast. In ten years, industrial inspection in oil and gas, energy, infrastructure and transportation will be the dominating purpose of drones worldwide [13]. In the context of Big Data, the development of drones and associated operating systems provides a good example of the fusion of technologies: technological progress could lead to improved simulation models, new materials, and information and communication technologies including AI, miniaturised electronics, and wireless 5G communication. All of these will have straightforward implications for both current and future drone capabilities.
Drone tech and Big Data are fueling an array of enterprise initiatives. In general, drones are comparatively low-cost and easy to deploy in mapping and data-collection missions. They can be programmed, which also facilitates their use. The type of sensor carried by UAVs determines the sort of data acquired and the obtainable information. Through research and operational cases, they are demonstrating the capacity to support the inspection and monitoring of oil and gas pipelines. Prototype systems to monitor pipelines are reviewed in the literature, and some monitoring scenarios are proposed and illustrated [14], [15], [16].

Figure 9. Schematic illustration of monitoring scenarios. Source: https://link.springer.com/article/10.1007/s12517-017-2989-x/figures/2
Big Data on its own is not a silver bullet for oil and gas companies. Today, we are seeing a lot of analytics and vendors running around selling predictive maintenance to big industrial companies, but what these companies seem to miss is real domain competence embedded into their teams. That means having someone that is used to working with these machines and is working at the company fulltime – this is important for several reasons.
Firstly, to tell when a machine is operating as it should, and when it is not, is hard work that requires a share of an engineer’s time.
Secondly, the user has to know how the various sensors relate to each other to be good at predictive maintenance. The user has to be able to tell which sensor tells something about a mechanical issue and which sensor can say something about a performance issue, for instance. If the user does not know that, then the typical noise levels of these sensors will lead the data scientist to overfit their model. The last one is almost always a problem, and that is why the use of physics-based models is recommended to augment machine learning capabilities and deliver real value at scale.
Industry 4.0 reflects the next revolution of industrial innovation and now presents new opportunities for raising oilfield production performance to new standards of efficiency, control, and recovery.
As we have seen through this article, such digital innovations in data analytics are highly adaptable, the critical drivers for its adoption are the following:
One of the most impactful among them is the fact that the knowledge of the company’s best practices and expertise of the most senior and experienced people is captured and retained through Big Data systems in the corporation. This is the expertise that never retires and never leaves. The more is being used, the better it gets; the more experts it interacts with, the more data it is being fed, providing higher quality recommendations that drive operations to the new levels of operational performance. With that, it is probably one of the closest contributors to sustain competitive advantage technology can provide.
Experts and trend research suggests that those who will be at the forefront of the oil and gas industries are those able to generate energy for the lowest possible price. By digitising their upstream and downstream networks, companies are cutting costs and improving productivity in their supply chains. The advent of the “digital oil field” has helped produce cost-effective energy while addressing safety and environmental concerns. The essential elements that comprise an Oilfield 4.0 are advanced data analytics, the internet of things (IoT), cloud computing, artificial intelligence, deep learning, and edge connectivity. Oil & gas companies have seen a range of assets from adopting Big Data and analytics. Some key benefits of Big Data analytics include being able to visualise a drilling map, driving the drill most effectively and efficiently, or assessing the safety and environmental risk of oil and gas workers and the surrounding community.
[1] https://www.geoinsights.com/what-is-big-data/
[2] Nguyen, T., Gosine, R. G., & Warrian, P. A Systematic Review of Big Data Analytics for Oil and Gas Industry 4.0. IEEE Access, 8, 2020, 61183-61201.
[3] BP Energy, “BP Energy Outlook 2019,” BP Publishers, 2019. [Online]. Available: https://www.bp.com/content/dam/bp/business-sites/en/global/corporate/pdfs/energy-economics/energy-outlook/bp-energy-outlook-2019.pdf
[4] https://www.ibm.com/industries/oil-gas/big-data-analytics
[5] https://www.hornetcorp.com/post/the-importance-of-big-data-analytics-for-the-oil-and-gas-industry
[6] https://pdgm.com/resource-library/articles-and-papers/2019/machine-learning-establishes-a-strong-foothold-in/
[7] https://www.woodside.com.au/innovation/data-science
[8] https://www.itnews.com.au/feature/the-mechanics-of-woodsides-watson-environment-440875
[9] https://www.weatherford.com/getattachment/50c1a851-dd89-4e48-83d6-9406d3220a3b/Autonomous-Well-Management-System-Increases-Uptime
[10] Nduagu, E., Alpha Sow, Umeozor, E., & Millington, D. (2017). Economic potentials and efficiencies of oil sands operations: processes and technologies. Canadian Energy Research Institute.
[11] Jin, H., Lin, X., Cheng, X., Shi, X., Xiao, N., & Huang, Y. (Eds.). (2019). Big Data: 7th CCF Conference, BigData 2019, Wuhan, China, September 26–28, 2019, Proceedings (Vol. 1120). Springer Nature.
[13] Stankovic, M., Hasanbeigi, A., Neftenov, M. N., Ventures, T. I., Basani, M., Núñez, A., & Ortiz, R. Use of 4IR Technologies in Water and Sanitation in Latin America and the Caribbean. 2020. Available: https://publications.iadb.org/publications/english/document/Use-of-4IR-Technologies-in-Water-and-Sanitation-in-Latin-America-and-the-Caribbean.pdf
[14] Gao, J., Yan, Y., & Wang, C. Research on the application of UAV remote sensing in geologic hazards investigation for oil and gas pipelines. In ICPTT 2011: Sustainable Solutions For Water, Sewer, Gas, And Oil Pipelines (pp. 381-390).
[15] Mezghani, M. M., Fallatah, M. I., & AbuBshait, A. A. From drone-based remote sensing to digital outcrop modeling: Integrated workflow for quantitative outcrop interpretation. J. Remote Sens. GIS, 2018, 7, 1000237.
[16] Gómez, C., & Green, D. R. Small unmanned airborne systems to support oil and gas pipeline monitoring and mapping. Arabian Journal of Geosciences, 2017, 10(9), 202.
The outbreak of the coronavirus disease (COVID-19) was declared a Public Health Emergency of International Concern (PHEIC) and has since spread to many countries. While a lot more research is required about the virus and what causes it, medical science and research have confirmed that it is transmitted through direct contact with respiratory droplets of an infected person or by touching surfaces that are contaminated with the virus and then touching their face. While COVID-19 continues to spread, it is imperative that communities take action to prevent further transmission, reduce the impacts of the outbreak and relook their day-to-day activities. The COVID-19 crisis has accelerated changes that were already underway and triggered a radical rethink not just of where we work, but how, where and when.

In an environment where COVID-19 does not differentiate between borders, ethnicities, disability, status, age or gender, the workplace setting should continue to be welcoming, respectful, inclusive, and supportive environments to all. But how does this ‘’new face’’ of office environments look? We find ourselves at a crossroads – where the history of the future of the workspace is full of false hopes, failed reforms, and promises of change that seem never to materialise. The tools to remake the workplace were already available before Covid, and few used them. While at the same time the inertia of the old system is underestimated and workers are yearning for a return to normality after a straining crisis. For the majority of the population who do not fall into the key workers’ category, working from home has taken some getting used to, with many dining tables, couches and even garden sheds converted into an office working environment and office desk.
This article examines the most significant commercial office space questions of the post-pandemic moment. It will look at what the COVID-19 SARS CoV-2 is, how it spreads and how to prevent its spreading by highlighting conceptual and proven ways of combatting transmission through Architectural and Engineering design principles in conventional and new office spaces.
In response to COVID-19, countries across the world have implemented an array of public health and social measures, such as the limitation on movement, partial or full closure of schools and businesses, quarantine in specific geographic areas and a ban on international travel. As the local epidemiology of the disease changes, countries have adjusted these health and social measures accordingly (i.e. loosen or reinstate). As transmission intensity also declined, some countries began to gradually re-open workplaces to maintain economic activity. This requires establishing protective and preventative measures – all of which to be implemented in the existing, or in some cases new, architectural and engineered designed spaces (www.who.int, n.d.)
On 16 April 2020, WHO published an interim guidance document that aimed to provide advice on adjusting Public Health and Social Measures and offered general guidance for non-healthcare workplaces and workers, while managing the risk of new cases. According to WHO (www.who.int, n.d.), the risk of work-related exposure to COVID-19 depends on the probability of coming into close (less than 1 metre) or frequent contact with people who may be infected with COVID-19. The WHO further states that the risk of work-related exposure also includes contact with contaminated surfaces and objects. With workplace-environments classified as Medium exposure risk areas, its related jobs or work tasks require close, frequent contact with the general public, or other co-workers, visitors, clients or customers, or contractors, but that does not require contact with people known to be or suspected of being infected with COVID-19.


Image 1: 2019 Novel Coronavirus (2019-nCoV) Virus structure. Cold (World Health Organization, 2020).
COVID-19 is a disease caused by a new strain of coronavirus. ‘CO’ stands for corona, ‘VI’ for virus, and ‘D’ for disease and was formerly referred to as ‘2019 novel coronavirus’ or ‘2019-nCoV.’ The COVID-19 virus is a new virus linked to the same family of viruses as Severe Acute Respiratory Syndrome (SARS) and some types of the common cold (World Health Organization, 2020). Symptoms of infected individuals with the COVID-19 virus will experience mild to moderate respiratory illness and recover without needing special treatment. At the same time, older people and those with underlying medical problems are more likely to develop severe illness.
Based on the current research available, the virus is transmitted through direct contact with respiratory droplets of an infected person – this can be via coughing, sneezing or touching surfaces contaminated with the virus and then touching their face (e.g., eyes, nose, mouth). Although the COVID-19 virus may survive on surfaces for several hours, it can be killed by simple disinfectants.
The economy-crippling SARS-CoV-2 outbreak has caused many individuals, scientists, health care practitioners, architectural and even engineering designers to revisit their understanding of droplet and airborne transmission. These two primary transmission mechanisms form a continuum, and the following is generally accepted:
Considering the small amount of non-conclusive scientific research and evidence available regarding the long-range airborne transmission in the sense of droplet nucleation, as with TB and measles (Preparedness, prevention and control of COVID-19 in prisons and other places of detention, n.d.) the WHO reported on evidence of airborne transmission. And it can be seen in the context of opportunistic long-range droplet spread (Key Messages and Actions for COVID-19 Prevention and Control in Schools, 2020), as reported during The van Doremalen SARS-CoV-2 survival study.
The van Doremalen SARS-CoV-2 survival study (COVID-19 and food safety: guidance for food businesses Interim guidance 7 April 2020 Background, n.d.) incorrectly reported to have shown that SARS-CoV-2 can remain viable in the air for extended periods. Which supported the numerous evidence reporting that long-range airborne viability has yet been found outside of lab settings. Correlations between culture viability, particle size and the real world infectious quantum were not described in this study (COVID-19 and food safety: guidance for food businesses Interim guidance 7 April 2020 Background, n.d.) as it was not the study’s intention to claim COVID-19 was airborne while similar lab studies have also demonstrated a 3-hour airborne survival for viral strains such as Ebola, that was concluded not to be airborne (PAHO and UNOPS, COVID-19 Measures for prevention in construction, 2020)

The spread of diseases and viruses seldom obey only one means of transmission (obligatory transmission) but often have inclinations (preferential transmission) while occasionally exploiting circumstances which provide rare opportunities for transmission (opportunistic routes). SARS-COV-2 is understood to be preferentially droplet and contact spread (a form of droplet spread where droplets can settle on objects or materials which are likely to carry infection, such as clothes, utensils, and furniture). With possible uncommon and opportunistic airborne spread (Operational considerations for COVID-19 management in the accommodation sector Interim guidance 30 April 2020 Background, n.d.).
Droplet transmission precautions include standard safeguards such as PPE, hand washing and physical distancing, while airborne precautions include negative pressure isolation, respiratory protection and special exhaust or filtration regimes.
The faecal-oral route of transmission is acknowledged for COVID-19 and indirectly affects ventilation system design (Preparedness, prevention, and control of coronavirus disease (COVID-19,) for refugees and migrants in non-camp settings Interim guidance 17 April 2020 Background, n.d.). Special consideration should be given to common scenarios where the aerosolisation of contaminated wastewater is a possibility and include areas such as bathrooms where adequate ventilation practises and negative pressure relative to adjacent spaces should be considered.

SARS and COVID-19 outbreaks on commercial aircraft have proven to be unusually rare – mainly due to the high ventilation rates implemented on these aircraft, according to Cirrincione (Cirrincione et al., 2020). Studies tracing contacts and COVID-19 virus spread on flights seem to show multiple cases of very low to zero transmission rates according to WHO (WHO,2020. Considerations for the disinfection of environmental surfaces in the context of COVID-19). The context of this aircraft outbreak findings highlights the essential role ventilation has in creating safe, habitable environments, while also revealing and once again confirming the low-risk levels associated with the airborne transmission of COVID-19.
Studies conducted by the WHO (Considerations for quarantine of individuals in the context of containment for coronavirus disease (COVID-19), n.d.) have found real-world SARS-CoV-2 in air, ducting and on extraction fans. However, they have so far failed to prove that the virus that was found was still viable (www.who.int, n.d.). It has been suggested that high temperature and humidity would reduce the spread of the virus (www.ilo.org, 2020) with temperature ranges (>50°C) beyond what anyone could endure in an ICU while the humidity ranges of between 40-60% are achievable. The high humidity slows the nucleation of the viral droplet and increases its settling speed, reducing its range. It is therefore essential to note that transmission risk in a home will not be the same as in workplaces.
The 2020 outbreak of COVID-19 in a restaurant in Guangzhou raised some important, long overdue questions around the airborne spread of this and other diseases as stated by Belingheri, Paladino, and Riva in their report (Belingheri, Paladino and Riva, 2020). The study conducted on the Guangzhou Restaurant Outbreak (2020) shows that the transmission range of COVID-19 may exceed the generally prescribed separation distance of 1m under certain conditions.
In the Guangzhou restaurant illustrated below, one sick patron infected nine others. In the centre of this history-defying moment, it was found that the air conditioning units cooled different zones, and one unit blew directly over the three tables – the origin of the COVID-19 outbreak. The woman believed to be the index-patient was seated with her family at the middle table. Air flowing from the air conditioning unit may have blown her respiratory droplets over to the table farthest from the AC unit. The air then bounced off the wall and brought those droplets back in the direction of the table on the other side, next to the AC unit.

Image 2: Guangzhou Restaurant COVID-19 outbreak (2020). (Science News, 2020) Y. LI et al./MEDRXIV 2020
This is still considered a critical event in the study of SARS-CoV-2 transmission and supports the widespread caution to be taken with regards to the airborne transmission where similar events are not widespread by now.
The outbreak in a call-centre on the 11th story of a South Korean office block offers some extraordinary insights, specifically considering the significantly reduced number of reported cases in the adjacent room on the same floor. This case cluster provides an example of how COVID-19 can emerge in a bustling open-office setting — and how to intervene and stop transmission. According to the report (Science News, 2020), it appears as if the outbreak followed physical compartmentalisation and not HVAC zoning (although an HVAC plan of the building was not discussed). It is reported that COVID-19 is exceptionally contagious in crowded office settings and that the exposure time correlated with the transmission risk while lobbies and lifts contributed little to the spread of the virus. Employees sat side by side, talking on the phone for long shifts which lead researchers to suspect that prolonged proximity, rather than touching the same surface drove the spread.

Image 3: South Korean call centre-19 outbreak (2020). (Science News, 2020)
Most of the 97 COVID-19 cases in this outbreak were concentrated on the 11th floor with 94 call centre employees testing positive for COVID-19 (workstations of people who got infected shown in blue).
It can be concluded from the two outbreak-scenarios that opportunities for the re-evaluation of the following should be taken advantage of:
It is essential to differentiate between ventilation and air-conditioning when discussing indoor contamination. The term ventilation is used to describe any system that induces decontaminated, fresh or outdoor-air to circulate into a space using a supply or extraction system. Diluting ventilation is the most universally used system while other modes of contaminant removal involve displacement and local exhaust ventilation systems, each with its approach to infection control.
In contrast to ventilation, air-conditioning refers to only the mechanical cooling or heating system. In some instances, this is installed directly in a space (Split-AC), to offer thermal comfort and even humidity control. In-room air-conditioning systems that circulate air directly within a space with no or little dilution or extraction offer no reduction in airborne contaminant levels and even assist in the distribution of contaminants in the space serviced by this air-conditioning unit.

Openable windows, sometimes at the expense of indoor comfort, can be considered as a means of ventilation apertures and even offer highly effective ventilation. Encouraging occupants of any office space to open windows will reduce that risk of transmission, even though long-range droplet transmission of SARS-CoV-2 is relatively low in comparison to short-range transmission. Allowing office space occupants to use air-conditioning to either heat or cool a space while the adequately provided windows are open, can improve levels of open window compliance which is preferential over limiting AC use to reduce long-range transmission. Considering additional strategies to both improve open window compliance and reduce AC usage would be to ease strict corporate dress codes as this can contribute to improving thermal comfort levels during hot and humid seasons.
The WHO’s advice regarding SARS-CoV-2 transmission during clinical interventions is as follows:
“In the context of COVID-19, airborne transmission may be possible in specific circumstances and settings in which procedures or support treatments that generate aerosols are performed. I.e., endotracheal intubation, bronchoscopy, open suctioning, administration of nebulised treatment, manual ventilation before intubation, turning the patient to the prone position, disconnecting the patient from the ventilator, non-invasive positive-pressure ventilation, tracheostomy, and cardiopulmonary resuscitation.” – WHO 2020, (In the face of a pandemic: Ensuring Safety and Health at Work can save lives Safety and health at work, n.d.)
While the WHO’s position acknowledges the increased risk of transmission in crowded and under-ventilated spaces, their proposed appropriate response is not to increase prescribed general ventilation rates, but rather to avoid overcrowding and ensure that existing and new ventilation systems are maintained correctly.
The CDC’s advice regarding SARS-CoV-2 transmission is almost identical to its control measures for SARS-CoV-1:
“The primary transmission of COVID-19 is from person-to-person through respiratory droplets. These droplets are released when someone with COVID-19 sneezes or coughs. COVID-19 can also be spread when you are in close contact with someone who is sick (e.g., shaking hands or talking). A physical distance of at least 1 meter (3ft) between persons is suggested by the World Health Organization (WHO) to avoid infection, although some WHO member states have recommended maintaining greater distances whenever possible. Respiratory droplets can land on objects or surfaces around the person when they cough or talk, and people can then become infected with COVID-19 from touching these objects or surfaces and then touching their eyes, nose or mouth. Recent data suggests that there can be transmission of COVID-19 through droplets of those with mild symptoms or those who do not feel ill” (CDC, 2020).
While the US-CDC and WHO maintains that the airborne transmission of the COVID-19 disease is not of primary concern, ASHRAE (being an association dedicated to ventilation engineering) focuses on the airborne component.
“Transmission of SARS-CoV-2 through the air is sufficiently likely that airborne exposure to the virus should be controlled. Changes to building operations, including the operation of heating, ventilating, and air-conditioning systems, can reduce airborne exposures“(CDC, 2020).
REHVA’s temporary guidance document is unfortunately limited to commercial and public buildings REHVA (REHVA,2020), but similar to ASHRAE, REHVA focusses on engineering controls for airborne transmission. REHVA acknowledges the importance of droplet-spread precautions and the lack of quality evidence for airborne transmission.


Image 3-4: (REHVA’s temporary guidance (REHVA,2020)).
The IUSS Building Engineering Services Guidelines (Building Engineering Services, 2020) which is mandated for new buildings by provincial departments of health by reference in Government Notice R116, describes risk-based ventilation criteria which is in its basic understanding applicable to COVID-19, but excessive. This guideline was developed with control measures for the ongoing TB epidemic in mind. It would be more than appropriate for most workspaces and therefore, suspected confirmed COVID-19 patients should only be treated in negative pressurised rooms that comply with the guidelines.
The 2011 edition of the SANS 10400 Part O is often criticised for overprescribing ventilation rates when compared with international best practice. The mechanical ventilation criteria of this standard prioritise indoor air quality over the energy efficiency of a building and take a strict approach to ventilation in many spaces. The 10 ACH standard and more is typical for areas with any risk of airborne contamination but provides insufficient performance guidance for naturally ventilated spaces.
While the SANS 10400-O:2011 demands unprecedently high ventilation rates and offers little supporting evidence with the criteria, it should be considered better than many international standards for use in general settings where airborne contamination is a risk. Unfortunately, the SANS 10400-O:2011 does not permit the simultaneous use of natural ventilation and air-conditioning which can lead to many architectural and engineering designers to erroneously conclude that windows in air-conditioned spaces should not be opened/openable.
Universal measures for the prevention in the transmission of COVID-19 apply to all workplaces in a medium-risk environment and all people at the workplace, such as employers, managers, workers, contractors, customers and visitors. Regular and thorough handwashing with soap and water or with an alcohol-based hand-rub should be encouraged at all hand hygiene stations. Respiratory etiquette and policies must be promoted and adhered to by all employees and visitors at the workplace while wearing medical face masks.

Measures to keep a physical distance of at least 1 metre between people and avoiding direct physical contact with other employees must be introduced and enforced in the workplace. The reduced density of people in the building/office area (no more than 1 person per every 10 square metres), spacing at least 1 metre apart for work stations and shared spaces, such as entrances/exits, lifts, pantries/canteens, stairs, where queuing of employees or visitors/clients might occur will also contribute to a healthy, COVID-19 conscious workplace.
The need for physical meetings must be minimised, and the avoidance of crowding by staggering working hours to reduce congregation of employees at common spaces such as entrances or exits is highly advisable. As an alternative, shift or split-team arrangements, or teleworking can be implemented/enhanced.
Cleaning of all surfaces, using soap or a neutral detergent, water, and mechanical action (brushing, scrubbing) should be done at hourly intervals, followed by disinfection to inactivate (i.e. kill) pathogens and other microorganisms on surfaces after surface cleaning. High-frequency-touch surfaces should be identified for priority disinfection (commonly used areas, door and window handles, light switches, kitchen and food preparation areas, bathroom surfaces, toilets and taps, touchscreen personal devices, personal computer keyboards, and work surfaces).
Indoor spraying or fogging is not recommended, along with the spraying of people with disinfectants (such as in a tunnel, cabinet, or chamber). Face-to-face and skin-to-skin contacts must be minimised and avoided completely where possible, arranging workers’ workspaces to work side-by-side or facing away from each other. Assigning staff to the same shift teams can also contribute to limiting social interaction. Plexiglass barriers at all points of regular interaction can be installed and cleaned regularly. Most importantly, an increased ventilation rate, through natural aeration or artificial ventilation, preferably without re-circulation of the air, is advisable.
With many companies now looking to re-evaluate what ‘’return to work’’ might look like once the COVID-19 wave of infection has decreased and a sense of normality returns, integrating working from home into a working week will become a long-term way of working. As an immediate result of this, one vital consideration springs to mind: what type of space will businesses require for their office staff?
The ‘hub and spoke’ approach to office spaces is a model that could become more popular and involves having a main office (the ‘hub’) and lots of smaller branch offices (the ‘spokes’), which are often closer to employees’ homes. The post COVID-19 transition period accommodates this model quite seamlessly and ultimately makes a lot of sense. It would reduce the need for employees to use public transport and offer an effective working environment. The predicted need for flexible suburban offices in the short-term is still to be seen, as in the long-term too, as a portion of workers might have the capacity and aspiration to make these working arrangements more permanent. This ultimately creates a more flexible and local working culture.
Currently, many existing and newly designed office buildings and workplace-settings follow the model of the cube or open-plan arrangement and are designed to enhance and promote collaboration and efficiency – sometimes leading to the opposite results due to poor implementation. Interior designers, architects and scientists alike recommend reflecting the company’s values through office design while leaving room for growth and installing features that facilitate both collaborative and individual work that will contribute to a successful cube or open-plan office arrangement.

The proliferation of open-plan offices has allowed for much research on which elements serve to increase productivity, happiness and most importantly in a post-COVID time, physical health and disease control. So, what have we learned about office environments in the past that we can use to improve upon the model in a post-COVID-19 era?
The ventilation culture and overall engineered guidance justifiably bear the risk of being biased toward over-prescribing solutions over which they have the greatest understanding and control. By revamping existing ventilation systems in resource-constrained workplace settings to meet undeniably, overly-cautious guidance and control measures, should not be conducted without the informed design method and rationale of a mechanical engineer.

Image 5: NASA sustainable development base in Moffett Field, California
For workplace, medium-risk spaces it might be sensible to implement temporary measures to limit transmission and include engineering interventions such as:
So now that we as architects are also looking ahead, we face the question of how to increase indoor ventilation without accelerating energy consumption. One solution currently found on the European market is a different type of window design that has a mechanical heat-exchange system concealed inside the window sill. Allowing outside air to be warmed or cooled as it enters the building is what truly makes this revolutionary in a time of post-COVID office spaces with the name of the game being flexibility – a point in time where creativity and engineering can meet. Alternatively, the complex system of displacement ventilation can be considered in newly engineered, architectural office spaces. This system entails placing vents at the top of a room that pulls out a cloud of exhaled air and filters air to be delivered in vents along the floor – limiting the amount of viral material circulating in the shared air.

So what do these new, innovative, engineered-design concepts mean for the existing open-plan office arrangement? Simple. The open plan is here to stay — with more nature.
Sealing employees into individual hard-walled rooms is undoubtedly not the answer to disease control in office spaces, but rather preserving the benefits of open-plan offices by installing airflow systems that filter and reduce the amount of exhaled air from other people that employees inhale. The traditional air-handling system where fans push filtered air into a room via large overhead ducts can easily be forgotten along with what 2020 and COVID brought with it. But like in 2020, the problem with this scenario is very real and cannot be avoided.
The warm air we exhale typically rises and accumulates at the top of a room forcing the newly filtered air to fight its way through the cloud of virus particles exhaled by everyone sitting nearby before it can reach an employee’s desk.
Shifting the focus of this scenario, we look to the skies and nature for help. Providing opportunities for employees to come in contact with the natural world is called “biophilic design” and can boost productivity and physical health. Installing “living walls” instead of bland partitions, incorporating circadian-friendly lighting that brightens and dims across the workday, using high-performance natural construction materials, such as cross-laminated timber, rather than concrete, will offer employees a happy, safe and healthy office environment and create a more inviting office that is also environmentally sustainable. This living wall in the Danielle N. Ripich Commons at the University of New England in Biddeford, Maine, is one such approach.

Image 8: Living wall, Danielle N. Ripich Commons, University of New England, Biddeford, Maine. (Gregory Rec/Portland Press Herald via Getty Images)
The shift to home-based work in 2020 has given employers a look at which tasks can be completed from home and which are better accomplished in person. Organisational psychologist Cristina Banks says that workers will be drawn to in-person/office work only when the office addresses psychological needs that the pandemic undercut. Banks is the director of the Interdisciplinary Center for Healthy Workplaces, a global research centre at the University of California, Berkeley. Safety, belonging, and self-sufficiency are three of the primary drivers of an individual’s sense of well-being, that have been “obliterated” by the pandemic.
Translating this into architectural design and spatial planning, the 6 Feet Office concept was developed. It’s a way of transforming existing offices that were not adhering to the COVID-19 workplace spatial standards, into places where the six-feet distance rule can be observed. The Six Feet Office space includes imperceptibly marked-out zones to keep office users separated at a safe distance and encourages workers to navigate the workspace in a clockwise direction.

Image 9: 6 Feet Office concept. (World Economic Forum, n.d.)
Even the office furniture of the post-COVID office space will see a radical reshape and decline in area consumption, with the office desk already shrunk from 1.8m to 1.4m and less.
New social safety concerns in the workplace will require a hybrid of the open office with some version of its former self. A happy medium with reasonable accommodations for privacy and sterility without stuffy, high-walled -cubicles, will take shape. Open offices with new privacy panels in place and workstations at a reasonable distance apart will satisfy social constructs. People’s expectations will be higher around opportunities to wash and sanitise their hands. We, as architects, must plan for the infrastructure that allows people in public spaces, corporate spaces, and restaurants to have that opportunity.
Pre-in-office meeting chatter at the coffee station is no longer the biggest concern in the workplace, but rather if there will be any people at the next in-office meeting. Asynchronous collaboration has become the preferred means of communication by tech-enabled employees, which enables them to work together in concept but not be together in their physical presence. It is that reason why large conference rooms in the post-COVID-19 workplace will be replaced by additional smaller meeting rooms of varying sizes and more open meeting spaces that can adapt in its occupancy. The popular client conference room adjacent to the reception area may be on its way out and replaced by smaller flexible meeting spaces equipped with powerful software.

As the COVID-19 pandemic shift our focus on cleanliness and hygiene, employees have become more conscious of their interaction with spaces such as office kitchens. To ease the conscience of employees worried about virus spread in the office space, employers need COVID-19 protocols for workplace bathrooms and kitchens.
Shared public bathrooms have always been a potential danger zone for health, and with the COVID-19 pandemic situation, the risk of germ spread has further increased. The significant challenges we face when designing and equipping a public bathroom is to find innovative ways to reduce splashing, reduce touching of bathroom surfaces, and avoid residual stagnant water. Aquablade is a flushing technology that is cleaner, quieter and smarter and uses discrete slots to channel a sharp flow of water across the toilet bowl to provide splash-free flushing. Infrared and capacitive flush actuation then ensures a touch-free flushing experience to prevent infections and disease-spread in bathrooms effectively.
The introduction of technologies like touchless faucets, sensor flushes, wall mounted ceramic products, automatic soap dispensers and many more is done to improve cleanliness by reducing touchpoints on highly trafficked places.

Urinal systems are equipped with an anti-Covid protection screen in glass and a BMS (Bathroom Management Systems) to notify cleaning staff on his/her mobile of a possible clogging in a particular urinal or toilet, even before the clogging appears. Advanced self-flushing technologies can be combined with this BMS to flush the urinal or toilet automatically in case it is unused for a long time.
By reimagining thresholds, other touchpoints can be eliminated using smart architectural design and space planning. Doorless entries to bathrooms are created — similar to the labyrinth of privacy walls commonly seen at the entrances to public bathrooms in airports and stadiums.

Reducing the opportunities for surface-to-person transmission of disease going forward, office designers are trying to eliminate shared touch points wherever possible. ‘’Touchless switches” where doors are opened by waving at a sensor rather than by pushing a button, specifically to mitigate viral transmission is one of the many innovative technologies developed to curb the spread of the COVID-19 disease in the office environment.
No-touch hardware may become a focal point of basic design to prevent the spreading of germs. Door handles, drawer pulls, and cabinet handles are some of the biggest criminals when assessing the amount of shared contact and contamination. New alternative solutions to this problem will allow for ‘hands-free’ operation that will be influenced by the healthcare sector into office spaces. Antimicrobial finishes will aid surfaces to kill germs on contact when instances, where alternative solutions are unavailable and shared touching, is simply unavoidable.
From QR codes to biometric access systems, automatic blinds, air-con systems, and AV displays – all usually relying on remote controls and are handled by the masses. Touchscreen hygiene is a longstanding issue, and one we must address in the age of COVID-19. The solution? Sound recognition technologies and building control apps. From using voice-enabled commands to instruct your office blinds to lower or increase the temperature of your office to controlling your office environment with the swipe of a smartphone – a handful of apps already exist to allow office space users to control workspace HVAC systems, elevators and lighting, photocopiers and vending machines through a smartphone. Your smartphone could even aid in practising social distancing. Made by the United Nations, the 1point5 app notifies users when someone enters their 1.5-metre radius with some being retro-fitted with social distancing management and monitoring technologies.
Workplace access is another area where touchless technologies can provide office members and visitors with a digitally managed experience by allowing individuals to navigate through checkpoints using a QR code or another mobile-based access keys.
Augmented reality (AR) is also an alternative route to the touchless office through removing keyboards and other workstation-based germ magnets from the office entirely and installing futuristic desk set-ups where virtual, custom screens float in the air while virtual avatars of other employees enhance social interactions in the virtual realm.
Ultimately, a dynamic virtual work environment anchored by genuine social presence and powered by next-generation devices would give people infinite workspaces with configurable virtual screens, whiteboards, and other visionary tools. Employees can choose to work alone or collaborate in a meeting room filled with virtual, remote co-workers.
Looking at the headquarters of the Bee’ah waste management company in Sharjah, UAE, a true sense of the term ‘’touchless office’’ is seen. According to recent reports in The Guardian (Archilovers, n.d.), ‘’the building has been designed around “contactless pathways” where employees don’t need to touch a surface as they walk around the space. Facial recognition technology automatically opens doors for occupants.

Image 10: Bee’ah Headquarters, Sharjah, UAE, 2020. (Archilovers, n.d.)
Lifts, blinds, lighting, and ventilation call all be operated with a smartphone, and you can even order a coffee using one.’’ For example, the building will have standard energy efficiency measures controlling the lighting and cooling and be linked to a staff management system, automatically detecting an occupant’s preferred settings. “The full building is aware. So anywhere you are in the building, you can talk to it, assuming there is a microphone or speaker nearby,” says Tayara (Archilovers, n.d.). “It is like having an assistant with you all the time.” There are undoubtedly privacy concerns around such technologies. Tayara says that the ability to record meeting minutes is opt-in, and employees were briefed about the facial recognition systems and informed each individual why their movements would be tracked in the building.

Image 11: Bee’ah Headquarters, Sharjah, UAE, 2020. (Archilovers, n.d.)
While the Bee-ah HQ is a mesmerising and captivating prospect, the touchless office seems far away, and the prospect of the paperless office for most workspaces even more. Humans are still creatures of habit and, particularly after the isolation of lockdown, we’re going to need some human interaction from our workspaces now, more than ever.
But a 100% touchless office may also not be feasible for all employers. Although there are already some examples of fully contactless offices around the world, not all employers will want to consider this route. This is mainly due to the costs of implementation, maintenance and running of the system, and for many people, the charm of office workspaces is the opportunity for human interaction.
Most architects have to consider the reasons people want to build, and that means addressing their values. The ‘why’ of design should be the greatest motivation and end reward in doing what designers do, which is solving a problem. Architecture and engineering, being a deeply inspired practical art of composition and problem-solving, should not question itself in this post-Covid world. However, it may be solving different problems due to the impact of the Coronavirus pandemic that will undeniably continue to be felt for several months to come as we all get to terms with the new measures the pandemic has brought with it. Physical distancing, only going out when it’s essential, continually washing and sanitising hands and surfaces and walking back to your car or into your home to fetch your PPE face mask. The current pandemic will be a catalyst for people and companies to reassess current practices, the way they work, where they work and when they work – all of these considerations will be a big part of our post-COVID-19 working environment.
Amidst the pandemic-imposed disruptions, architect Leonard Wyeth sees continuity as he describes the role of the architects as “Our role of interpreting how we occupy space, interact, gather, entertain, amuse and comfort each other has not changed. The ability of an environment to help us feel secure, to lift our spirits, to reach outward, look inward, to engage nature, to be inspired by awe, all are still fundamental to our role. Performance is a baseline. Values and motivation are fundamental to the art of architecture. Success requires that they remain inseparable.”
But the one thing that was changed by the pandemic, profoundly, is everyday life. The value we add to that of objects and celebrity worship, the architectural world’s fascination with novelty and invented aesthetics, all suddenly appear trivial when millions are worried about survival. In this time of intense change, the pre-Covid mindset allowed for the execution of buildings as a faceless transaction, a commodity exchange. Now, we stand more than half a year later, rethinking that approach. In a world forced into rapid transformation in all its spheres, where everyone is forced to rethink all they have come to know, architecture is not immune from introspection and seeing beyond itself. Let’s rethink if we need to, relook what we missed, reboot our thinking and pivot where we should.
Biological wastewater treatment utilizes the natural micro-organisms present in the waste streams to break down complex organic matter to cellular matter of bacteria, and thus effectively treating the water to remove the carbonaceous matter. Bacteria are the predominant group present in wastewater of which the E.Coli group is the most prevalent in sewage. Bacteria can adapt to the environment they are exposed to and based on the type of carbonaceous source, they will adapt their enzymatic system to suit the available food source which is referred to as the acclimatization phase. Treatment facilities rely on the bacteria being in the exponential growth phase, where the maximum amount of carbonaceous matter is absorbed for growth to ensure the treated water is of the best possible quality.
Bacterial cells generate energy through the means of respiration (oxidative catabolism) or fermentation (fermentative catabolism), by taking electrons from the oxidized substance, which can be organic or reduced inorganic compounds. This is achieved through complicated biochemical reactions with the help of enzymes to transfer the electrons to another inorganic compound which is referred to as the electron acceptor. The most relevant electron acceptors are listed in decreasing order of energy release: oxygen (O2), Nitrate (NH3–), Sulphate (SO42-) and Carbon Dioxide (CO2). Depending on the type of micro-organisms present, they will utilize the electron acceptor present in the media with the highest energy release to allow for maximum growth of the micro-organisms. This results in the predominant metabolic pathway utilizing the oxygen present in solution, which is referred to as aerobic conditions. Once all the oxygen is consumed, micro-organisms present that are capable of utilizing nitrates start reducing it to nitrogen gas as part of the denitrification cycle. This is typically the transition zone referred to as anoxic conditions, where all oxygen has been consumed, but there is still the presence of nitrates. Once all the nitrates are consumed, full anaerobic conditions occur where the only electron acceptors present are sulphates and carbon dioxide. Sulphates are reduced to sulfides which are typically present as H2S, associated with the foul odour related to sewage treatment, and carbon dioxide, which can be reduced to methane.
Because the aerobic reactions release more energy, these organisms can reproduce faster than their peers and also makes the treatment process more effective at organic matter removal. The higher reproduction rate results in increased sludge formation, which is more efficient in organic matter removal from solution. Anaerobic reactions might not release the maximum amount of energy. Still, the final product compounds may have other advantages such as the possible precipitation of metal content as sulfide minerals, or the production of methane gas which can be recovered as an energy source. Depending on the source of wastewater that requires treatment, and the chemical composition of the water used as a transport medium, there may be unique opportunities available which would determine the best treatment process.

Figure 1: Various electron donor pathways for biological organic decomposition
This article will describe the various processes related to wastewater treatment and how treatment facilities are optimized to achieve optimal carbonaceous matter removal. Understanding these parameters is crucial to operating wastewater treatment facilities, and how to manipulate them to achieve compliant discharge when there are changes in the feed water quality. By adjusting the operating parameters, the organic matter removal from sewage can be optimized to be achieved either through oxidation of organic matter (aerobic conditions) or the fermentation of organic matter (anaerobic conditions). For the organic matter to be utilized by the bacteria, it needs to be present as readily biodegradable, which is usually the case in domestic wastewater treatment. The larger compounds with more complicated chemical structures need to be broken down before they can be effectively utilized. This is achieved by exoenzymes present within the bacterial cell walls and referred to as hydrolysis. This process does not consume energy, but the complex compounds are transformed into smaller molecules which can be more readily consumed by the bacteria.
To ensure growth and propagation of the microbial population, an appropriate substrate is required as a feed source. A substrate is referred to as a mixture of essential nutrients such as nitrogen, phosphorous, carbohydrates, fats, vitamins and minerals. This mixture is typically referred to as the feed carbonaceous substances and measured as biological oxygen demand (BOD). This is done by a standardized test which measures the cumulative oxygen concentration consumed after five days of incubation which is referred to as BOD5. During 5 days it is assumed that all the carbonaceous matter will be oxidized by the micro-organisms present under aerobic conditions, leaving just the nitrogenous compounds for final oxidation if the time is continued. In some cases, the oxidation of nitrogenous compounds can take place before five days are over, and in then adjustments would need to be made, which is why BOD test results can vary greatly.
The carbonaceous source must consist of a specific ratio of components critical to the growth of the inherent bacteria. In some cases where a specific element is deficient, it will be required to be dosed supplementary, but the guideline ratio for nutrients is:
BOD : N : P = 100 : 5: 1
Because wastewater treatment facilities rely on microbial cells being in the exponential growth phase, either one of the critical nutrient concentrations can be a rate-limiting factor and affect the efficiency of the facility.
As previously stated, E.Coli is the predominant microbial organism present in sewage water and is referred to as a mesophile, which has peak growth in the range of 20°C to 40°C. Staying within this range, the microbial activity of a mesophilic bacteria can be described by the following equation (E.A.R. Ouano, 1981):
Equation 1
This equation indicates that the effect of temperature is exponential, and hence managing the system temperature as high as possible without damaging the bacteria will have the most effective treatment.
Micro-organisms are typically classified on their capability to utilize free oxygen molecules present in solution, which are referred to as aerobic bacteria. Anaerobic bacteria can only utilize oxygen present in organic and inorganic compounds such as carbohydrates, nitrates and sulphates. Some anaerobic species can shift their metabolism to utilize molecular dissolved oxygen to oxidize carbonaceous matter, and these are referred to as facultative bacteria.
Aerobic reaction breaks down complex carbonaceous compounds to carbon dioxide, nitrates, sulphates and extracellular matters, of which none of these elements produces an odour and explains why this has historically been the preferred treatment method. The rate-limiting factor is the availability of oxygen dissolved in water, which is very low. Treatment relies on mechanical addition of air through energy-intensive mixers or aerators, which contributes to high operational costs for these treatment facilities.
Anaerobic reaction relies on the reduction of compounds in solution to supply the oxygen for the bacterial metabolism, and as a result compounds such as sulphates and nitrates can be reduced to hydrogen sulphide and elemental nitrogen respectively. This is an attractive treatment solution where there are strict discharge limits regarding sulphates and nitrates. However, the generation of hydrogen sulphide can be a health and safety risk, as well as generating an odour in the surrounding area. The reaction rate for anaerobic breakdown is significantly slower than aerobic. So, this process is typically reserved for the sludge from aerobic treatment only, due to the lower volume to reduce reactor design requirements for the desired residence time. One of the by-products formed through anaerobic digestion is methane gas, which has a high energy content and can be harnessed for heat generation through combustion, or converted to electrical energy through a combustion generator.
Different microbial groups have their tolerances for pH range, with bacterial growth optimized between 6.5 and 9.0. Carbon dioxide is a by-product of biological degradation, and therefore the presence of carbonates and bicarbonates are important as buffering reagents to prevent fluctuations in pH. It is especially important to monitor the pH during anaerobic digestion to ensure the pH remains stable and does not reach toxic levels, which can typically be addressed by adding limestone or hydrated lime to the solution as a buffering agent. Water with high total hardness occurring naturally will have a buffering effect on pH without the addition of chemicals required.
Due to aerobic micro-organisms receiving the most energy from the conversion of organic matter, this treatment process has faster reaction kinetics. It avoids the potential generation of odorous hydrogen sulfide formation. The reaction is explained by the simplified equation below:
Equation 2
The oxidation state of the compounds present in the reaction indicates the maximum quantity of energy available through the reaction. The more reduced state of the compound, the more energy it contains. Micro-organisms will attempt to utilize the compounds in such a manner to release the most amount of energy for the reproduction of the organism. The micro-organisms will attempt to oxidize the final product to the highest oxidation state, which is CO2 for the carbon components, and also why the aerobic micro-organisms have the highest growth rates.
Average raw wastewater pH is in the alkaline to neutral range, which means that the bulk of the ammonia is present as the ammonium ion (NH4+) and will be further oxidized to nitrates as per the following reaction:
Equation 3
Equation 3 is a simplification of the bacterial metabolism of two different species, Nitrosomonas and Nitrobacter, which complete the intermediate reaction from nitrite to nitrates (M. Von Sperling, 2007). It is important that the anoxic reaction also take place, which utilizes the hydrogen ions for the reduction of the nitrate to nitrogen gas. Natural waters with high alkalinity provide a buffer to prevent the pH from dropping too low, which could start adversely affecting the micro-organisms.
Once the oxygen has been depleted in solution, and there is a high concentration of nitrates present, an interim phase occurs, which is referred to as the anoxic zone. As indicated earlier, this phase is important to prevent the acidification of the solution by consuming hydrogen ions. Heterotrophic bacteria utilize nitrate as the electron donor instead of oxygen for their metabolic processes as seen below:
Equation 4
Nitrogen is formed as gas and could cause settling issues if it occurred within the clarifiers in the treatment process. So it is important to ensure there is sufficient time for the heterotrophic micro-organisms to ensure that nitrate concentration in the effluent meets the discharge standards.
Anaerobic digestion is achieved by a balance between different species of bacteria which can be simplified as two groups, the acid formers and the methane formers (Design, pg 173). The conversion of organic matter to methane occurs in two stages, the acidogenic phase and the methanogenic phase. During the acidogenic phase, the organic matter is converted to organic acids such as acetate which does not effectively remove the organic matter from solution, but only changes the phase it is present. The methanogenic organisms utilize the organic acids to convert them to methane, carbon dioxide and water which converts the organic material to the gaseous phase and effectively achieves organic removal as per the equation below:
Equation 5
The acid formers produce organic acids which drop the pH and inhibits the growth of the methane-producing bacteria once the pH drops below 6.0. Further reduction of the pH, in the absence of a buffering element such as carbonates, will result in inhibition of the acid-generating bacteria below a pH of 4.0 and thereby render the treatment facility ineffective. If the feed stream has a high BOD5 requirement with low nutrients, the acid-forming bacteria predominantly utilize the nutrients and result in lowering of the pH. It is therefore recommended that the design caters for at least 50% of the nutrient requirements of an aerobic reactor to allow for sufficient nutrients available for the methane-producing bacteria to grow efficiently.
Biological sewage treatment processes can be divided into two main classifications regarding the structural formation of the biomass, which is either dispersed or attached biomass growth. For dispersed growth, there is no supporting structure present in the facility for biomass to attach to, and it grows in the dispersed form, suspended in the liquid. Attached biomass growth processes actively provide a growth medium for the biomass to attach to and form a biofilm. Depending on the design of the system, the media can be permanently submerged or receive intermittent liquid discharges, and retains explicitly the media and accumulated biomass. The primary biological treatment principles are the same for either classification; however, the kinetics can differ significantly between the two processes.
One of the main advantages to dispersed growth processes such as the activated sludge process is the agglomeration of cells to form a secondary structure referred to as floc. As the biomass growth continues in the floc structure, it becomes larger and gains mass. The advantage of this is that natural sedimentation occurs due to higher mass, causing the floc to settle out of solution, as well as entrainment of suspended organic matter that has not been sufficiently decomposed. It is important to take into account that the size of the floc which forms is predominantly determined by the rate of agitation and aeration taking place within the process and is an important operational parameter to monitor.
The formation of floc is dependent on operational efficiency. It can vary from 50 to 500 micron, which can result in significant concentration profiles for BOD and dissolved oxygen within the floc structure. On the boundaries of the floc, the bacteria can readily hydrolyze and metabolize the organic matter encountered in the medium. Moving towards the centre of the floc, there may be a nutrient deficiency which can result in a portion of the organisms reverting to anoxic metabolic processes, despite the presence of dissolved oxygen in solution.
The successful operation of an activated sludge treatment facility relies on a good floc formation throughout the process. This is achieved when there is sufficient aeration and mixing to create a homogeneous solution, with an adequate supply of oxygen throughout. However mixing and aeration should not be excessive to the point where it can cause shear forces stronger than the adhesive strength of the floc particles, which will cause breakage and reduce the treatment efficiency.
Another important consideration for dispersed biomass reactors is that the hydraulic retention time of the solution must be greater than the doubling time of the micro-organisms to give them sufficient time for cell growth. If the flow rate exceeds this design requirement, there is the risk of washing out the bacteria to the downstream processes and reducing the treatment efficiency.
By providing an attachment media for micro-organisms inside the reaction vessel, it is possible to create much higher biomass concentrations in the process. Historically media such as gravel was the most widely applied, but development in attachment media to optimize available surface area has seen the application of rotating biodisc reactors as well as fixed bed reactors. The biomass grows through cell-to-cell interaction to form a densely populated structure along the surface of the attachment media. Nutrients are adsorbed from the solution at the outer layer of the biofilm and transported by diffusion through the layers of the micro-organisms to be metabolized. This creates a nutrient and oxygen concentration profile within the biofilm where the outer layer can have aerobic conditions, but once the oxygen is depleted there is a transition to anoxic conditions. Finally, fully anaerobic conditions are achieved at the innermost layers.
A distinct advantage of the attached growth principle is that the biomass is fixed within the reactor, and nutrients are absorbed from the liquid phase meaning that there is no addition of suspended solids to the influent water. This reduces the need for final clarification of the treated water, whereas dispersed media requires more efficient filtration that is typically achieved through rake clarifiers.
For the attached growth treatment processes, a homogeneous flow and nutrient distribution is a critical control parameter. If there is an overload of nutrients the biofilm can grow too thick and block flow in the trickling bed filter, or block the area between rotating biodisc treatment facilities. This will reduce the organic removal efficiency as well as cause an eventual collapse of the biofilm for the micro-organisms that are isolated from a feed source.
Insufficient nutrient feed to the biofilm will result in the inner anaerobic layer growing, which could create an imbalance between the by-products created causing poor growth conditions for the aerobic layers which can lead to collapse between the layers of the biofilm.
Maturation ponds are widely utilized as a final effluent water quality polishing stage, whereby pathogens are removed to make the discharge water quality meet specific disinfection requirements. There is limited BOD removal achieved in maturation ponds, mostly related to sedimentation. Still, in a primarily aerated environment with maximum sunlight penetration, the primary focus is to remove faecal bacteria from a solution. The primary mechanisms affecting faecal bacterial removal are:
Research done by Feachal et al. (1983) showed that increased time and temperature in ponds result in increased faecal bacteria die-off. Maturation ponds are designed to be shallow, which allow for adequate sunlight penetration which promotes algal growth. The algae increase in this environment and consume CO2 from solution at a faster rate than it can be produced by bacterial respiration. Carbonate and bicarbonate ions are dissociated to form hydroxyl ions and carbon dioxide, algae consume the CO2, resulting in a disproportionate rise in pH, which can exceed 10. Sunlight at specific wavelengths can damage faecal bacteria cells which further accelerate the die-off of cells and improving final effluent quality.
These factors are important to take into account when evaluating existing operational wastewater treatment facilities with maturation ponds as a final treatment step. Poor performance of the upstream processes can result in sedimentation within the maturation dams, reducing their residence time making treatment less efficient. Due to the high nutrients in these ponds, there is the risk of eutrophication taking place or reed beds establishing. While they have some polishing function, the sunlight penetration into the pond is severely compromised, and there is increased competition for the algal population. With proper maintenance, maturation ponds can be an effective effluent polishing step, and a much cheaper solution compared to active chemical dosing facilities.
Because wastewater treatment facilities rely on the natural micro-organisms to achieve organic removal, these facilities run well with minimal operator inputs under normal design conditions. However, there are key parameters that need to be monitored to ensure optimal treatment conditions are being maintained for effective organic removal.

Figure 2: Wastewater treatment process diagram
To achieve maximum nutrient removal in an activated sludge process, sludge is recycled from the final clarifier and mixed with the feed to increase the micro-organism concentration within the reactor. This portion of sludge that is recycled is referred to as the Return Activated Sludge (RAS). In contrast, the remainder of the sludge is discharged either to digestion or to sludge drying beds which is referred to as the Waste Activated Sludge (WAS). Through the continuous recycle of sludge, the micro-organism concentration can be increased to 20 to 30 times of the natural concentrations, which achieves much more efficient nutrient removal.
The average target range for MLSS in an activated sludge process should be within the range of 2 000 to 4 000mg/L. The higher the MLSS value, the more effective the nutrient removal and shorter residence time is required, which allows for savings in the construction phase. There are practical limits which dictate an upper limit for MLSS values, such as maintaining the high dissolved oxygen required by the high concentration of micro-organisms and that the final stage clarifier has fixed settling capacity. Once biomass concentration exceeds the upper limit (depending on design), the final effluent quality will be compromised, and disinfection targets may not be achieved.
Measuring dissolved oxygen can be described as one of the most critical parameters that need to be monitored and accurately controlled to ensure optimal performance. Injecting oxygen into the reactors is one of the most energy-intensive portions of any wastewater treatment works, and hence also a major contributor to treatment cost. It is therefore essential to supply sufficient oxygen to achieve nutrient removal, but not provide excessive oxygen as this will waste energy and can lead to other operational challenges.
It is recommended that dissolved oxygen concentration should be kept at 2mg/L in the aeration chamber, which ensures sufficient oxygen supply for the aerobic micro-organisms without using excessive energy. Suppose the oxygen is provided at high concentrations >4mg/L. In that case, it can cause conditions to favour the growth of filamentous bacteria which are much more difficult to settle and can cause operational challenges in the final clarifier process.
If there is insufficient dissolved oxygen, the nutrient removal process will be adversely affected, and a longer residence time will be required within the reactor. There will be a transition to anoxic conditions, which is required for some processes for effective nitrate removal. If complete anaerobic conditions are achieved, it can result in the generation of H2S and odour related complaints.
Wastewater treatment facilities are designed to allow for specific hydraulic retention time, dependent on the feed water BOD requirements. For low BOD requirement, the requirement can be 4 hours, up to 24 to 48 hours for high BOD industrial wastewater sources. Residential and industrial water flow rates leading to wastewater facilities have periodic fluctuations but should not typically exceed design rates under normal conditions.
In most developed countries, there are separate sewer systems for sewage and stormwater, so in the event of a storm, the wastewater treatment facility will not be impacted by such events. When the stormwater and wastewater collection in the same sewer systems, there is the risk of hydraulic overload during storm events. This can cause the flushing of micro-organisms from the treatment facility, which will result in no organic removal and the contamination of downstream facilities. This can be overcome with buffer dams for the raw water or potential effluent buffer systems such as maturation ponds which will cause additional polishing and improvement of the effluent water quality.
The time micro-organisms spend within the reactor is an important control factor for these facilities, and is determined by the ratio of recycling of sludge to the wasting of sludge, and should be within the range of 2 to 8 days depending on the feed water BOD requirement.
Equation 6

The SRT is an indication of the amount of time that the mass of micro-organisms is circulated in the reactor, divided by the mass of micro-organisms in the waste stream, and the clarifier effluent. Typically the concentration in the clarifier effluent is disregarded as it is assumed close to zero if the clarifier is operating optimally. The mass of micro-organisms being sent to waste will either be for composting, drying for disposal to landfill or further processing through digestion and the possible recovery of biogas. If the digestion process is optimized, there is the possibility of energy recovery from the biogas generated, and the digestate which is rich in nutrients can be used for agricultural purposes.
Food to mass ratio refers to the BOD of the raw feed water to the mass of micro-organisms in the reactor. The incoming BOD is equated to food for the micro-organisms, and if this is too high, some of it will pass through the reactor and contaminate the downstream processes. There is also the risk of viscous bulking, where the micro-organisms have too many nutrients as a feed source, and their physiological properties change to the extent where these micro-organisms do not settle well. When this ratio is too low, the population of micro-organisms change as these conditions favour the filamentous bacteria that are better at collecting the dispersed nutrients, which again result in poor settling in the final clarification process.
Traditional wastewater treatment facilities have been designed to remove organic waste, but due to rapid industrialization, there are increasing cases where additional pollutants are present in solution. Some of these components are elemental metals, perfluoroalkyl substances (PFASs) and pharmaceutical and personal care products (PPCPs) which are still being investigated to understand their potential environmental impacts and possible health risks (Y. Zou, 2019).
PFASs have been produced since the early 1950s, due to their strong electronegativity and the small atomic size of fluorine which gives enhances properties to molecules such as increased acidity, higher surface activity at low concentrations, stability and water-repellency (Z.Wang et al., 2017). Due to their high stability, these synthetic compounds are accumulating in the environment, and their associated health risks are not sufficiently understood and require more research. The risks regarding pharmaceutical and personal care products (PPCPs) are related to their secondary impacts, as they cannot be metabolized by the humans or animals and also risk the building up in the natural environment.
A study done by Y. Zou et al. (2019) investigated the impact of these contaminants on algae and fish to determine their health and activity. Their findings indicate that metals have the highest risk to the health of fish and algae, whereas they found that the impacts on fish and algae differ significantly between PFASs and PPCPs. PPCPs were identified as having the next most significant impacts on algae and fish, whereas PFASs posed relatively low risks to these organisms.
Traditional wastewater treatment facilities rely on biological processes to affect organic removal, whereas these pollutants are inorganic and natural and not affected by these processes. It should be noted that under anaerobic conditions and the presence of sulphates and metals, the sulphate can be reduced to sulfide and result in the precipitation of metal sulfide compounds, which is one way that existing treatment facilities can be modified to achieve metal removal. Further work is required to better understand the impact of PFASs and PPCPs, as well as the processes required for their removal.
There are specific regulations regarding the reuse of wastewater which depend on the reuse application, and due to the various treatment technologies implemented for wastewater treatment, they may limit the final effluent quality that can be achieved. Typical residential wastewater can be treated efficiently to remove all organic contaminants, and with effective disinfection, the final effluent may resemble potable water quality. For health and safety concerns, wherever wastewater effluent is reused for potable standards, the double barrier system is implemented. This is where reverse osmosis membranes and advanced chemical oxidation is used to ensure bacterial, inorganic compounds and elements are removed to ensure the health of the final consumers. These technologies are expensive due to advanced equipment, high energy and chemical reagent requirements.
One avenue for treated wastewater effluent reuse is in industrial process water streams where the industrial user has its wastewater treatment facilities. For industrial water where there are not very strict quality requirements, but the water is primarily used as a mode of transport and cannot affect the final product quality. Ineffective disinfection is the primary risk with reuse of effluent due to the risk of infecting the process water circuit where it is being used. Once micro-organism growth has established in industrial processes such as cooling towers or heat exchangers, it can be tough to remove. Due to the rapid growth of the micro-organisms, they can potentially form large colonies or biofilm, resulting in blocking of pipes and affecting equipment functionality. Ensuring that there is sufficient disinfection is critical for such applications, and there is online monitoring equipment capable of measuring free chlorine or oxygen reduction potential as an indicator.
The main consumer for treated effluent globally is for agricultural purposes, with different quality requirements depending on the type of crop that is grown or whether the water is used for irrigation of public areas. A review done by F. Shoushtarian & M. Negahban-Azar (2020) provides an extensive summary of the various guidelines and water quality limits that are used in different countries across the world. The different parameters and their limits are compared per country with the main differences highlighted to indicate how the standards change per area. BOD5 is used as a general performance indicator for wastewater treatment facilities, and some of the results are summarized in the table below as per the review:

Table 1: Comparison of effluent reuse BOD5 concentration limits
BOD5 is, however, only one of the parameters that need to be monitored to determine whether the effluent is fit for use, but multiple other parameters need to meet the limits. Residual free chlorine is an important parameter to monitor as it is an indication of effective disinfection; however, if the values exceed 0.5mg/L there, it can affect some types of crop growth. Guidelines and limits will have to be updated on a global scale as more research is done into the new emerging pollutants and there are new results available on the potential health and safety impacts of these pollutants to humans, animals and different ecosystems. Wastewater treatment facilities will have to be optimized and expanded in the future as the contaminants in our water sources increase, and treatment requirements become more onerous. Continuous development in wastewater treatment technologies is of critical importance in our fast-paced globalizing economy.
E.A.R. Ouano, 1983, Principles of wastewater treatment, Biological Processes, Volume 1.
Distillation columns are vital components for the Chemical Process Industry (CPI). As a result, they must be designed correctly and in the most cost-effective way possible. The interior of the distillation columns is arguably the most important part of the column as they are difficult to access after start-up. An internal breakdown in the column can impact the entire process. The internal components of the columns can either be plates or packing, which each have their characteristics that make one option more appropriate than the other for the desired separation application (Pilling & Holden, 2009).
Various factors need to be considered when deciding on the internals of the distillation column such as the flowrates of the vapour and liquid phases, the reason for separation, the desired product characteristics and the physical properties of the vapour and liquid phases. Most of this data can be acquired from process simulation software such as Aspen Plus. This information, together with physical property models, can tell the user the reflux ratio, the optimum number of stages, the column’s economics and the purity of the product.
The following considerations need to be taken into account when deciding on the column internals: conditions and compositions of the streams entering and exiting the column, the chemical reactivity between the components being separated and the materials of construction, the temperature ranges, the tendency to foul, the corrosivity and the risk of contamination. These all affect the design choices for materials used in the column internals and are design constraints for the column internals (Pilling & Summers, 2012).
The final decision between a plate or packed column for a particular separation can only be made with complete certainty by costing each design. However, this will not always be beneficial, useful or necessary. The decision can be made by using previous experience as well as considering the pros and cons as outlined below (Sinnott, 2005, 589):
When considering the choice between plates and packing, two types of packing options exist: random packing and structured packing. Packed columns tend to be used for distillation, gas absorption and liquid-liquid flow. The flow can be counter-current; however, in some gas-absorption columns, co-current flow is used. The types of packing that exist include Raschig rings, Pall rings, Berl saddle ceramic rings, Intalox saddle ceramic rings, metal hypac and super Intalox ceramic rings. Three different types of plates exist: sieve plate (perforated plate), bubble-cup plates and valve plates (floating cap plates). When considering the type of plate to be used, factors considered include the cost, capacity, operating range, efficiency and pressure drop (Pilling & Holden, 2009).
Distillations plates, also called trays, allow for an amount of liquid holdup. This is to allow the vapour flow to encounter the liquid and allows for vapour-liquid mass transfer which is necessary for separation to occur.
The most popular type of plate contactor in distillation (and absorption) columns are cross-flow plates as depicted in the image below where the liquid flows in downcomers in the intervals between plates.

Figure 1: Example of a cross-section of a distillation column that depicts cross-flow (Hebert & Sandford, 2016)
Other types of trays exist which do not have downcomers and are termed non-crossflow plates. Instead, the liquid flows through large holes in the plates, and these types of plates are typically called shower plates. Furthermore, other kinds of non-crossflow plates exist that are designed for special cases, for example, in instances where a low-pressure drop is necessary.
There are three main types of cross-flow plates used in vapour-liquid mass transfer.

Figure 2: Tray configuration with a sieve plate (Pilling & Holden, 2009).
The deck in a typical cross-flow plate contains an inlet region where the liquid is supplied as depicted above. The downcomer is the outlet. Plates need to have holes for vapour to flow through. The perforations make up approximately 5 % to 15 % of the tray area. The spacing between the trays is outlined below. The downcomer area consists of approximately 5 % to 30 % of the cross-sectional area of the column. This is dependant on the liquid load.
The weir regulates the amount of liquid build-up on the plate surface and any excess liquid froths over into the downcomer. The weir height usually is 50 mm (Pilling & Holden, 2009).
The operating conditions of plates are restricted to minimise weeping at low throughputs and flooding (also termed entrainment) at high throughputs. Weeping happens when the pressure drop on the vapour-side of the plate deck is too small to bear the liquid on top of the plate. As a result of this, the liquid trickles through the perforations. A dry-plate pressure drop less than 12 mm H2O increases the likelihood that weeping will occur. Generally, 20 % of weeping results in a decrease of 10 % efficiency.
On the other hand, flooding happens when very large vapour velocities transport liquid droplets to the tray above. This is termed jet flooding. Entrainment is more damaging to the ability of the tray to produce the desired separations as it causes back-mixing of the liquids. Generally, 10% of entrainment results in a decrease of 10 % efficiency.
The flooding of the inlets or backup may result in the flooding of the downcomers. The liquid head determines the height of the froth in the downcomer at the plate inlet or downcomer outlet, pressure drop across the plate as well as friction losses. A froth level rise in the downcomer is due to an increasing pressure drop across the plate and an increase in the flow rate of the liquid. When the amount of froth surpasses the downcomer height, the tray above will flood. This can all be prevented or minimised by widening the spacing between trays, reducing the pressure drop across the trays, enlarging the downcomer clearance or lowering the outlet weir height. Typically, extending the length of the downcomer is not effectual as the losses due to friction in the downcomer are insignificant (Pilling & Holden, 2009).
This is the most basic version of a cross-flow plate. The vapour flows through the holes in the plate whilst the liquid is retained on the tray by the vapour flow. However, there is no adhesive material in the holes to prevent liquid from trickling out and therefore “weeping” can occur through the perforations. As a result, this can decrease the plate efficiency. The hole size can vary, but bigger perforations are more common. The advantages and disadvantages of sieve plates are listed below (Separation Technology, 2012).

Figure 3: Illustration of sieve tray perforation, top view and side view (Sinnott, 2005: 559).
Advantages
Disadvantages
Bubble cap plates are pictured below and are the most traditional type of cross-flow tray type. Many versions exist, and they can be customised for specific design requirements. The most prominent feature of the bubble-cap plate are the risers which are small pipes where the vapour flows through that are covered by a cap. This feature ensures that a certain amount of liquid remains on the plate regardless of the vapour flow rates (Separation Technology, 2012). This aids in reducing weeping.
Advantages
Disadvantages

Figure 4: Depiction of a Bubble cap tray constructed of stainless steel (Separation Technology, 2012).
These have become the most popular tray choice in mass transfer applications in the CPI Industries.
The valve tray consists of a sieve plate with large diameter perforations that are covered by movable flaps which rise as the vapour flowrate increases. The valve plate design has an improved efficiency when compared to sieve plates. This is because the valves are closed at lower flow rates, and weeping is minimised.

Advantages
Two types of valve plates exist: Fixed valves and moving valves. Fixed valves remain open whereas moving valves are opened when vapour flows through the perforations and raises the valve cover.
The moving valve became a standard addition to the process industry after its invention. The main advantage it offered was that it allowed for movement that could accommodate fluctuating vapour flowrates. The maximum valve movement is restricted either by the legs (below left) or by the cage height in the design (below right)
The full advantage of the moving valve which provides a range of motion is that maximum movement of the valve at full height can be attained by allowing high vapour flow rates. Moving valves have a nominal turndown (ratio of maximum vapour flowrate to minimum vapour flowrate of 4:1). Moving valves produce an incredible turndown ratio. This is because at high vapour flowrates the valve operates at maximum height whereas at low vapour flowrates the valve partially closes due to low-pressure drop across each plate. This results in the weeping of the liquid and poor column efficiency. However, due to the moving valves, they partially close and minimise weeping.
Turndown ratios of 10:1 are feasible when the moving valves are designed well by installing valves in rows of alternating thickness. This allows for control over which valves open and closes first when vapour flowrates fluctuate (Hebert & Sandford, 2016).
The disadvantage of moving valves is that fouling can cause the extruding portion to stick to the tray deck. Also, unexpected operating conditions such as a sudden high vapour flowrate can cause the extruding portion to “pop” off, thereby resulting in parts of the deck having a sieve plate design. That defeats the purpose of the valve tray and causes all the disadvantages of sieve plates.

Figure 6: Moving valves. Open position with a simple extruding cover (left) and caged assembly design (right) lower (Hebert & Sandford, 2016)
The most basic fixed valves are formed from metal sheets that have been punched. They have the advantage of no moving components. As a result, they do not stick, pop, erode or corrode. Furthermore, the larger open perforation prevents fouling. The valves can be customised to have varying heights by varying the cut and geometry of the perforation.

Figure 7: Fixed valve consisting of an extruded perforation with a smaller diameter (left) and larger diameter (right) holes (Hebert & Sandford, 2016).
Moreover, the hydraulic capacity is inversely proportional to the size of the valve perforation. The smaller the opening, the larger the capacity. Additionally, the smaller the net rise, (as depicted in the figure below) the less entrainment is anticipated. Another advantage of fixed valves is they are resistant to process upsets due to mechanical reliability (Hebert & Sandford, 2016).

Figure 8: Net rise is the difference between the level position to the full height of the extruded cover (Hebert & Sandford, 2016).
Thicker metals do not allow for as much stretching and extension and, as a result, net rise movements are restricted. These limitations can be tackled by a fixed valve plate that integrates large perforations in the deck with separate cover pieces that overlap the opening as illustrated below.

Figure 9: Enhanced Fixed valves with cover piece that overlaps the perforation for thicker metal sheets that form the deck (Hebert & Sandford, 2016).
The tapered cut minimises any stagnant liquid on the deck, and this design also minimises any weeping. Due to the large hole and fixed components, fouling is also suppressed. Despite the shape not being able to be formed by extrusion and having to be mechanically fit together, the design is still more mechanically robust than moving valves (Hebert & Sandford, 2016).
The main points to consider when deciding on the right plate type between valve plates, sieve plates, and bubble-cap plates are pressure drop, efficiency, operating range, capacity and price. However, when trying to minimise the cost (and excluding bubble cap trays), the diagram below illustrates the level to which various plates should be considered when fouling plays a factor in the column design.

Figure 10: Levels of fouling resistance and relevant plate type that is recommended (Hebert & Sandford, 2016).
Pressure Drop
Pressure drop is a significant factor to consider, especially in vacuum columns. The pressure drop will depend on the specifics of the plate design. However, sieve plates produce the smallest pressure drop, with valve plates causing a slightly bigger pressure drop and bubble-cap plates producing the largest pressure drop (Sinnott, 2005: 560).
Efficiency
The efficiency used to calculate the plate efficiency is called the Murphree efficiency and is the same for all three types when considering the design flow range (Zuiderweg et al., 1960). Therefore, this point is insignificant when used as a determining factor between the different plate designs.
Operating Range
This is the most important point when considering the three types. The operating range refers to the span of liquid and vapour flow rates over which the tray can operate well and stably.
Some variability should be included in this operating range during times when the flow rate will drastically differ out of normal operating range. For example, start-up and shutdown. The turndown ratio refers to the ratio of maximum flow rate to the minimum flow rate.
Bubble cap plates have a positive liquid seal and work well at exceedingly small vapour flowrates. Sieve plates depend on the vapour flow to maintain the liquid on the tray and work poorly at a low vapour flow rate. However, with enhanced designing, sieve plates can operate well.
Valve plates provide an improved operating range than sieve plates and are cheaper than bubble caps.
Capacity
When evaluating the capacity factor, which is defined as the diameter of a column necessary for a given flow rate, the capacity is rated as sieve > valve > bubble cap.
Bubble caps are the most expensive of the three. It should be noted that cost is also based on the material of construction used.
The amount of area that is available for the perforation is dependent on the area that will already be taken up by the structural support and the calming zones. Calming zones are regions of the tray at the inlet and outlet sides of each plate. Standard dimensions exist for the width of each zone. For diameters less than 1.5 m, a zone of 75 mm is recommended, and for diameters greater than 1.5 m, a 100 mmm zone is necessary. The support ring for the plates is usually between 50 mm to 75 mm; it should be noted that the support ring should not block the downcomer area (Sinnott, 2005: 572).
The height of the entire distillation column is dependent on the plate spacing. The typical spacing of trays usually ranges from 0.15 m to 1 m. This value is contingent on the operating conditions as well as the distillation column diameter. The smaller the diameter, the closer the spacing. Closer spacing is also used when the headroom of the distillation column needs to be compact. In distillation towers with a diameter over 1 m, plate spacings between 0.3 to 0.6 m are used with a spacing of 0.5 m used as an initial approximation in the design iteration process. Larger spacings are necessary when feed and side streams are located between plates (Sinnott, 2005: 573).
The main stipulations that need to be met for packing are that it should meet the following conditions:
Numerous types of packing exist in various shapes and sizes to meet various demands. However, they can be split into two main categories:

Figure 11: Different types of packing options available (a) Raschig rings (b) Pall rings (c) Berl saddle ceramic (d) Intalox saddle ceramic (e) Metal Hypac (f) Ceramic, super Intalox (Sinnott, 2005, 590)
Packing with a consistent layout, for example, grids have an advantage in that they provide a much larger surface area for substances to flow through. This allows higher flow rates of gases where a minimal pressure drop is important such as in cooling towers (Sinnott, 2005, 590).
Structured packing usually consists of alternating layers of mesh, gauze or fine corrugated sheets as illustrated in the image below. These are typically made of a wide range of materials including ceramics, graphite, plastic or metal alloys. The material is arranged with a regular geometry to obtain a large surface area with a large void fraction. Structured packing usually results in smaller pressure drops and overall improved efficiency with shorter bed heights when compared to random packing. However, they are typically more costly to construct, and the time of construction is also lengthier (Pilling & Holden, 2009).

Figure 12: Structured packing (Pilling & Holden, 2009).
The main advantage of structured packing when compared to random packing is that the separation efficiency, typically expressed in the height of packing equivalent to a theoretical equilibrium plate (HETP) is usually less than 0.5 m and the low-pressure drop of 100 Pa/m.
Structured packing is more favoured than random packing for the following cases:
Structured packing is typically more expensive than random packing. However, this comes at the advantage of an improved efficiency when compared to random packing.
Due to the slim size of structured packing and the large amount of surface area, there is negligible corrosion allowance. As a result, the material of construction is a crucial decision choice. Wire gauze packing made from woven metal cloth is the best choice for separations that require a high efficiency with low liquid loadings. However, sheet metal packing that has both a high surface area as well as a superior quality liquid distributor is also a good alternative.
The surface area available in structured packing can span from 40 m2/m3 to 900 m2/m3. Grid packing typically lies within 40 m2/m3 to 90 m2/m3 and has a robust design with a large open area and has a high capacity. Grid packing is typically used when fouling and hydraulic load stresses are high. Structured packing greater than 500 m2/m3 is typically used in air separation and the manufacture of refined chemicals (Pilling & Holden, 2009).
Structured packing is typically perforated and textured, which assists the liquid distributors and can be designed to accommodate two liquid phases. This requires careful design as the liquid phases can segregate on the surface of the packing resulting in reduced efficiency.
When many stages are required, structured packing is a good alternative due to its high efficiency (HETP). However, it is important to weigh the design choice between structured packing and plates because plates are preferable when the liquid flow rate is high, and the pressure drop is high. Furthermore, structured packing needs collectors and distributors, which can require a taller column than the equivalent column design that uses plates in the column internals.
When separating components where thermal degradation is a concern, structured packing provides two advantages. Firstly, the liquid holdup is low in columns with structured packing. This results in short residence times of the components in the column leading to a lower risk of degradation. Secondly, structured packing has a smaller pressure drop, and this means that the bottom of the column can be operated at lower pressures and temperatures, which also lowers the risk of thermal degradation. The execution and efficiency of structured packing is a result of the packing geometry and liquid distribution (Pilling & Holden, 2009).
Raschig Rings were the first kind of packing used in mass transfer processes, and they consist of a hollow cylindrical tube with a height to diameter ratio of 1:1. They display an exceptional strength to weight ratio and are much more resistant to fouling than other types of packing (The Pall Ring Company, 2020).
Pall rings are a progression from the Raschig rings and have the same cylindrical shape and ratio. However, they have two rows of punched out holes with webs from the centre which drastically enhances the execution of the packing with regards to the pressure drop, throughput and efficiency (The Pall Ring Company, 2020).
They are most appropriate when a low-pressure drop is required in high capacity scenarios and can be customised in a wide variety of sizes for optimum performance for separation. They create a large amount of randomness, and the high surface area to volume ratio enhances mass transfer. Pall rings provide a consistent ratio of free and blocked pathways regardless of the orientation.
The internal structure with the web-like design results in a mechanically robust type of packing that is appropriate for use in packed beds that are deep.
Metal pall rings can be made of stainless steel alloys or other metals and provide the advantage that they are capable of handling higher temperature separations and are highly resistant to fouling and are also mechanically robust. They are typically used in separations with H2S, NH3 and SO2 as well as absorption and stripping, steam stripping, quench towers and direct contact cooling.
The ceramic Berl saddles are an improvement from both the Pall rings and Raschig rings with regards to an enhanced flow distribution. The shape of the saddles has both the external and internal surfaces exposed, and the distribution of vapour-liquid is the same on both sides. When comparing Berl saddles to the previous two types of packing, they produce a lower pressure on the surrounding column walls (Ultimo Engineers, sa).
Berl saddles typically consist of chemical grade porcelain which is chemically resistant to many substances apart from Hydrogen Fluoride and strong alkalis. It is most appropriate for sulphuric acid applications.
The Hypac and Intalox rings are improvements from the Pall ring and Berl saddles. Furthermore, Intalox saddles, Hypac and super Intalox are all trademarked designs by the company Norton Chemical Process Products Ltd (Sinnott, 2005).
Packing can be customised in various materials including carbon, plastic, ceramic and metals. However, rings with thinner walls make the packing more efficient. Thin packing is easiest to manufacture when the material of choice is metal or plastic rings. Furthermore, the composition of the packing is determined by the operating temperature and the properties of the fluid: fouling, corrosivity etc.
Ceramic packing is preferred for corrosive fluids but is inappropriate for fluids with high alkalinity. Furthermore, plastic packing can react with some organic fluids and can be restricted by temperature rise and is therefore not typically used in distillation columns. Due to the robust nature of metal packing, it is preferred in situations where the distillation may be unstable instead of ceramic packing, which is much more easily broken.
When considering the cost-effectiveness of the materials, Raschig rings are less expensive (price per unit volume) when compared to Pall rings or saddles. However, they are less efficient. When evaluating the cost-effectiveness of Raschig rings, the column works out to be more expensive when taking into consideration the whole column. When designing new columns, Pall rings and Berl or Intalox saddles are typically used (Sinnott, 2005,590 – 592).
The rule of thumb is that the biggest size of random packing appropriate for the dimensions of the column should be used. However, an upper limit of 50 mm should be put in place. It should be noted that small-sized packing is considerably more expensive. Packing sizes greater than 50 mm do not show any cost-benefit when considering the reduced mass transfer efficiency. This is because of larger packing results in substandard liquid distribution (Sinnott, 2005, 592).
Recommended size ranges are:
Optimal operation and separation are achieved by attaining adequate liquid distribution along the length and breadth of the column. Poor distribution is the cause of issues in packed columns. To obtain the highest possible efficiency, the column needs to have an evenly wetted surface area. The surface area of the packing needs to be covered entirely in an ideal situation. However, this is not practically possible when allowing for enough fouling resistance and an even liquid flow along the packing surface.
Suppose the actual liquid flowrate is less than the lower limit of the design value. In that case, the liquid levels in the distributor will be too small, and the flow to drip points along the length of the column will be non-uniform, resulting in poor separation efficiency. Similarly, if the actual liquid flowrate is larger than the upper limit of the design value, the liquid levels in the distributor will be too high, and overflows will occur. The separation efficiency will also be negatively impacted (Pilling & Holden, 2009).
Distillation column design is a complex and intricate process that requires a good comprehension of various concerns. Each design choice has an impact on the operational range, pressure drop, cost, capacity and efficiency of the overall processes. Observing the suggestions outlined here will allow for more knowledgeable decisions.
Sinnott, R.K. (2005), Coulson & Richardson’s Chemical engineering Design, Volume 6, 4th Edition, Elsevier, Massachusetts, USA.
Pilling, M. and Holden, B.S. (2009), “Choosing Trays and Packings for Distillation,” Back to Basics CEP, Sulzer Chemtech USA and The Dow Chemical Co.
The Pall Ring Company (2020) “Products for Mass Transfer Operations, Pall rings – Plastic”, The Pall Ring Company, https://www.pallrings.co.uk/products/pall-rings-plastic/, [2020, September 20]
The Pall Ring Company (2020) “Products for Mass Transfer Operations, Raschig Rings”, The Pall Ring Company, https://www.pallrings.co.uk/products/raschigrings/
, [2020, September 20].
Ultimo Engineers, (sa), “Ceramic Berl Saddles,” Ultimo Engineers, https://www.pallringsindia.com/ceramic-berl-saddles.html [2020, September 20]
Separation Technology (2012), “Distillation Column Tray Selection & Sizing,” Separation Process Industry, http://seperationtechnology.com/distillation-column-tray-selection-1/ [2020, September 20].
Pilling, M. and Summers, D.R. (2012), “Be Smart about Column Design,” Sulzer Chemtech USA, Reactions and Separations, American Institute of Chemical Engineers AiCHE
Hebert, S. and Sandford, N., (2016), “Consider Moving to Fixed Valves,” Koch-Glitsch, LP, Reactions and Separations, American Institute of Chemical Engineers AiCHE
Crude oil is extracted using different technologies according to the geology and location of the oil field. The design of the extraction plant depends on many factors, but the most important ones are the porosity of the rocks and the sediments’ viscosity. The efficiency of oil extraction reaches significant values due to the application of modern methods with chemical, physical, and thermal principles. The following methods are widely implemented in the industry, and their combined usage is mandatory to acquire the highest extraction efficiency of the plant.
The primary recovery method represents the first step of crude oil extraction. The oil stored underneath the surface is under high pressure, while atmospheric pressure is around 1 bar. Consequently, the difference between atmospheric and oil pressure represents the driving force for the oil lifting process. The space within the hollow well shaft is at the atmospheric pressure. The oil enters the shaft from the surrounding area and starts to flow upwards. While the oil travels upwards, the pressure gradient drops after some time. When the pressure of oil becomes equal to the atmospheric pressure, the driving force of the oil flow vanishes, and the extraction process stops. At that point, the pump usage is beneficial to generate the pressure difference. The pump pushes the gas underneath the oil. At that point, the gas pushes the oil up to the surface. The efficiency of the primary recovery is in the range from 5 to 10%.
The secondary recovery extraction method requires energy input to extract an additional amount of oil. Namely, the various types of fluids are injected in the reservoirs to produce higher pressures. Two primary types of secondary recovery methods are water injection and natural gas injection. The water injection method uses water created and separated from the oil in the primary recovery phase. That water is injected back underneath the oil to push oil to the surface. When recovered water ceases to be useful, it is disposed of. In that way, the water usage is optimized.
The gas injection method implies the usage of miscible or immiscible gases. The miscible gasses are injected to dissolve carbon dioxide and light hydrocarbon gasses in the oil, to lower its viscosity and resistance to flow. The usage of the miscible gases is highly desirable during the extraction of heavy crude oils. The reduction of oils viscosity and flow resistance significantly reduces the operational costs of the drilling process. On the other side, immiscible gases do not contribute to the dissolution of any fraction of crude oil. Their primary purpose is to increase the pressure in the ”gas cap”, and drive more crude oil to the wellbore.
The refineries are regularly placed far away from the oil field. There are various transportation options from the oil field to the refinery. The crude oil may be transported via rail cars, trucks, and tanker vessels and through pipelines. The suitable transportation type depends on the distance between the oil field and the refinery and the particular amount of crude oil that needs to be transported. The crude oil doesn’t represent a flammable substance, but it can catch fire, which may present a serious environmental issue. The crude oil is extremely toxic, which is another reason its handling is regulated by specialized transportation and storage policies.
Whichever type of transport is used, the crude oil has to be stored in an external roof tank, near the refinery. This type of tank possesses extraordinary dimensions, and it can accumulate vast quantities of crude oil. Unlike the fixed roof tank, this type of tank has a unique type of roof construction. It has a cylindrical shape with a fixed shell. The roof is made out of steel, and the roof position is adjustable. The roof consistently follows the level of the liquid in the tank by moving up and down. Therefore, the roof is in constant contact with crude oil, and it prevents the evaporation process. The prevention of breathing loss contributes to an increase in the overall system’s efficiency and the inability of the diffusion of crude oil gasses into the atmosphere. That is exceptionally significant regarding the high toxicity of crude oil gas and its impact on the environment. Furthermore, the rim evaporation is disabled due to the application of the sealed systems between the tank shell and the roof.
The crude oil must be pretreated before the distillation process. The oil contains many impurities from which the salts represent the most dangerous ones. The present salts may be hazardous in further processes by the following mechanisms. Firstly, the calcium and magnesium carbonates are formed as the scale at places where the liquid-vapor phase transformation of water occurs. Secondly, highly corrosive hydrochloric acid is produced by magnesium and calcium chlorides at high temperatures. Thirdly, sodium, arsenic, cadmium, lead, and other metals may poison the catalyst in various equipment. Lastly, removing some solids like arsenic is crucial for the absence of toxic substances in the flue gas. In that way, the ecological standards of the flue gas composure are satisfied. Hence, the desalting process has to be utilized before the separation process.
The present salts are primarily in the form of magnesium, calcium, and sodium chlorides, and sodium chloride, represent the most abundant one. The salts are not dissolved in the oil itself, but preferably in the emulsified water droplets. Also, the salts are found in the form of the crystalized and the non-dissolved solids.
Two types of desalting processes are presented below. The sole difference between them represents the number of used electrostatic reactors. It is the standard industrial praxis to use, whether one or two electrostatic reactors. The exact number of electrostatic reactors depends on salt concentration and the electrostatic reactor’s design. Some companies designed modified single-stage reactors that are more efficient than traditional two stages electrolytic reactors.
The first step of this process is not demonstrated at the diagram, which is the heating of the crude oil to a temperature of 100-150 °C. The freshwater presents another inlet stream in this process, and its volume flow represents the 4-10% of the crude oil volume flow. The third stream is composed of the demulsifying agent.

Figure 1. Simplified desalting process flow diagram
The demulsifying agent is a compound used to break oil/water emulsion into separate phases. The primary obstacle for the differentiation of phases in the emulsion is the oil film’s existence around the water droplets. The purpose of the demulsifying agent upon addition is to reach the oil/water interface and deteriorate the rigid film. After the formation of torn parts of the rigid film, the water droplets demonstrate a higher tendency to coalesce and ultimately constitute the separate phases. Many parameters must be taken into account during the design of this process, like temperature, type of crude oil, and droplet size. For complete phase separation, it is equally crucial to reach the proper mixing of the three streams. For mixture purposes, the mixing valve is frequently used. This valve is a regular globe valve, which provokes a pressure drop in the range from 0.7 to 3.5 bars. The pressure drop causes the appearance of large shear stress between separate layers of the fluid. In this particular situation, the most important manifestation of the enhanced shear stress is between the water droplet and the oil. The increase of shear stress produces the turbulence flow of the distinct parts of the mixture. This phenomenon forces interaction between water droplets.
Besides the usage of the globe valve, the spray nozzle is frequently used for water injection purposes. The spray nozzle transports the additional water in the form of droplets into the crude oils. The formation of droplets increases the contact area between phases, which enhances the process of mixing. On the other side, the flow of the water and the nozzle diameter must be appropriately designed to prevent the appearance of the small-sized droplets. In that case, the emulsion would be stabilized, and the efficient separation of phases would be disabled. Hence, it is crucial to properly design the whole mixing process and carry out an optimal decision regarding these two opposite effects.
After the mixing process, the mixture flows into the electrostatic separator. This separator is a horizontal cylindrical tank with a large volume. The large size of the tank provides the ability for a residence time sufficient to separate the inlet mixture into two distinct phases. The water droplets with insufficient diameter do not possess enough mass to be divided by the influence of the gravity force. Therefore, two electrodes are posted in this tank, and they are inducing the electric field between them. The water molecules are highly dipolar in contrary to other organic compounds present in crude oil. Hence, the electric field induces the attraction between the water molecules in the nearby droplets, promoting coalescence. Both alternative and direct current may be used to produce an electric field with a potential range from 12, 000 to 35, 000 volts. Under the influence of an electric field, the water droplets’ attraction force is formulated as follows:
Where ε is voltage gradient, d is droplet diameter, s is the distance between drops centers, and Ks is a constant for the particular emulsion system. After coalescence of water droplets into larger ones, their settling under the influence of gravity may be described by the Stock law:

Where:

More than 95% of salts and water is removed from the crude oil during the desalting process. The optimally designed processes remove up to 99% of salts.

Figure 2. Process flow diagram of the crude oil refining process
Distillation of crude oil is commonly executed in the following sequence. The distillation under atmospheric pressure comes first, and vacuum distillation comes after it. The crude oil obtained from the desalter passes through the furnace heated up to 400°C. Natural gas is frequently used as a fuel because it presents the refining process’s end product, and its usage reduces the heating costs. The low boiling fractions usually vaporize below 400°C at atmospheric pressure. It is crucial to maintain the temperature below this level to avoid the thermal decomposition or so-called cracking of the hydrocarbons.
The distillation column possesses many trays along the vertical axis, and there is a temperature gradient from the bottom to the top of the column. The various fractions of the crude oil are separated at different heights of the column, as it is presented in Figure 3. The most elevated temperature occurs at the bottom of the column, and its value decreases as the height of the column increases. Three prime factors contribute to the formation of the temperature gradient along the column. The steam at elevated temperature enters the column at the lowest tray. The saturated steam carries a lot of energy, and it transfers heat to the liquid fraction of oil. On the other side, the gas at the top is condensed in the reflux drum and moved back to the highest tray in the column. Therefore, the reflux stream contributes to the cooling of the upper section of the column. The last factor that affects the temperature distribution is the change of mixture composition along the column. Specifically, the volatile compounds are more abundant in the higher sections, and their evaporation temperatures are lesser than the one of the heavier compounds.

Figure 3. Atmospheric distillation
The water steam is another inlet stream in the distillation column. The steam is in the form of the saturated or reboiled steam. It enters the column in a temperature range from 90 to 120 °C, and a pressure range from 1 to 2 bars. Steam distillation is a complex process to control due to many manipulative variables of the process and the number of present compounds in crude oil.
The primary role of the steam is to carry the volatile compounds through the column. The steam entrance in the vapor phase causes a decrease in the partial pressures of all compounds in the oil. The reduction of vapor pressure causes a drop in the volatile compounds boiling point. In that way, the volatile compounds evaporate at the lower temperatures. It is exceptionally significant to mention that this process is only feasible if compounds possess higher vapor pressure than water, which is the case with the crude oil compounds.
Content and temperatures of the outlet fractions:
The thermodynamical equilibrium between the vapor and liquid phase is reached in every tray. The change of the molar ratio of compounds, during the distillation process, in both phases is shown in the graph below. The compound’s molar ratio rises as the temperature of the mixture approach the boiling point of the compound.

Figure 4. The x-y diagram of the distillation column
The crude oil and steam enter the first tray, after which the equilibrium between the gas and liquid phase is reached. The temperature is around 400°C, which causes all compounds besides the residue to evaporate, while the residue travels down the column in the form of the liquid. With the increase of the column’s height, the molar ratios of the heavier fractions decrease, while the composure of volatile compounds increases.
Let’s take, for example, the tray where the kerosene is separated. The vapor phase, mostly composed of kerosene and all fractions of naphtha, is coming to that tray. At that particular tray, the thermodynamical equilibrium is reached, and most of the kerosene is converted into the liquid phase due to the appropriate temperature, while other compounds continue to flow upwards in the vapor phase. The outlet stream, mostly composed of the kerosene, exits out of the column in the liquid phase.
That liquid stream enters the vessel where the steam stripping occurs. Namely, the liquid stream enters at the top of the vessel, while steam enters at the bottom and flows upwards. The steam retains a role to sustain the appropriate temperature, cause evaporation of the residual volatile compounds, and transport them back to the distillation column. In that way, the clean kerosene is obtained in the liquid phase at the bottom of the vessel.
Analogically, all other fractions are separated by the usage of the steam stripping.
The residue from the atmospheric distillation column travels to the vacuum distillation column. The primary purpose of the vacuum distillation is the separation of the residue fraction without affecting its structure. The temperatures higher than 400°C would cause the decomposition of the hydrocarbons. Accordingly, the invention of the vacuum contributes to the separation process. The evaporation of any compound occurs when its vapor pressure is equal to the pressure of its surroundings. The vapor pressure of the compound in the liquid phase rises, with the increase in temperature, as presented in Figure 5. The decreased pressure in the column enables the evaporation of the compounds at significantly lower temperatures.
The vacuum distillation column usually operates at 0.03bar pressure to enable evaporation of the heavy hydrocarbon with a boiling point higher than 450 degrees Celsius. The vacuum distillation may be designed to operate with or without the presence of the steam. The regular distillation is commonly used for gas oil and fuel production. The incorporation of stream enables the same separation efficiency, but it significantly reduces the operational temperatures. The steam stripping is widely used in the production of gas oil, lube oils, asphalt, or waxes.

Figure 5. Vapor pressure dependence on temperature
Vacuum columns posses greater diameters in comparison to the ones of atmospheric distillation columns. The vacuum may be generated in two following ways. Firstly, the usage of steam ejectors at the top of the column. The pressure drops in the throat of the ejector. That drop causes vapor suction, resulting in a vacuum generation. Secondly, the vacuum pump can be used at the top of the column.
The products from vacuum distillation are light vacuum gas oil, heavy vacuum gas oil, asphalt, and vacuum residue.
Different types of asphalt can be produced depending on the crude oil composure. The asphalt is a highly viscous liquid, and the addition of additives seriously affects that feature as well as other asphalt characteristics. The additives are a type of emulsification agent, and the most abundant substances in these agents are fatty amines. The contribution of the fatty amines is up to 25% of emulsifying agents’ content. Another important role of the fatty amines is the enhancement of the asphalt binding to the crushed rock’s surface. The de-asphalting unit is not presented in figure 2, but it is very important for producing pure and high-quality asphalt. The vacuum residue is treated with propane or butane in a supercritical phase to absorb the residual lighter molecules. The lighter molecules are transferred to the top of the column with the propane or butane, while purified asphalt is extracted at the bottom.
The essential difference between the asphalt and the petroleum coke is their structure. Namely, the asphalt has an aromatic structure while the coke has an aliphatic one. To convert the vacuum residue into coke, there is a need for a thermal cracking process.
The essential process, in the petroleum coke formation, is delayed cooking. In contrary to all previously described processes that are continuous, this process is batch continuous. The vacuum residue flows continuously through the furnace, heated to 480°C, which is sufficient temperature for the thermal cracking. The cracking of the hydrocarbons takes place in the drum. The cocker naphtha and the cocker gas oils are produced from the vapor phase, while the bottom outlet stream is composed of the coke.
The primary purpose of the hydrotreating process is the removal of sulfur and nitrogen compounds. The naphtha hydrotreating unit commonly uses a cobalt-molybdenum catalyst to remove sulfur by converting it to hydrogen sulfide. The unreacted hydrogen is removed along with unreacted hydrogen. The part of the hydrogen sulfide-hydrogen stream is recycled back to the reactor to transfer the unreacted hydrogen, using a compressor.

Figure 6. The process flow diagram of the hydrotreating unit
Reactor conditions for the naphtha hydrotreating process are temperature from 205 to 260˚C and pressure from 25 to 45 bar. The coke precipitates around the walls blocking the catalyst, so reactor temperature must be raised to maintain the desired process efficiency. At the moment, when the temperature in the reactor reaches 400 ˚C, the catalyst must be recovered.
Heavy naphtha is mostly composed of the C7-C10 hydrocarbons. Catalytic reforming represents the process of C7–C10 hydrocarbons conversion to aromatic compounds and isoparaffins. The main goal of catalytic reforming is to increase the octane number of the heavy naphtha. The increase of the octane number means greater power of the engine and the higher fuel quality.
The reduction of the nitrogen and sulfur below 1ppm is mandatory for the successful catalytic reforming process. That is why the hydrotreating process must be monitored continuously, and the catalyst in that process must be recovered promptly. The catalytic reforming process is endothermic, and it requires extensive energy input.
The light naphtha is mainly composed of the C4-C7 hydrocarbons. The isomerization of those hydrocarbons presents the process of their transformation into branched chains.
The isomerization and catalytic reforming have similar working conditions, and both reactions require the excessive inlet of the hydrogen stream. Regarding the naphtha’s content, the reaction conditions are in the following range: temperature from 495 to 525 °C and pressure from 5 to 45 bars.
The following reactions take place in these two processes:




Conversion of naphthenes to aromatics and isomerization of n-paraffins to i-paraffins are two most important reactions of interest. With proper control of the working parameters, aromatics in the feed and those produced in the reactor should remain its structure.
The by-product of the reformation reaction is hydrogen. It is essential to mention that the dehydrogenation catalyst can also catalyze the hydrogenation and hydrocracking. Noticing reactions 1 and 3, the excessive amount of hydrogen moves equilibrium to the left side by Le Chatelier’s principle. Therefore, the kinetics effect is not favorable in this case, and the thermodynamics effect must compensate it and ensure avoidance of potential side reactions.
The article will give an overview of a typical natural gas compression facility. The article will also cover other ancillaries in a gas compression facility. Though gas compression facilities have similar functional equipment, there are usually differences in configuration and equipment type, therefore there might be differences between the equipment described in this article and other facilities.
Gas is a substance (element or compound) existing in a free expanding state, it freely expands to fill an entire container. Gas molecules are far apart, this implies they can be compressed to a smaller volume.
Various elements and compounds exist in a gaseous state including natural gas, oxygen, and hydrogen.
Amongst these gaseous substances, Natural gas is one of the most important because of its wide applications. It is a source of fuel for electricity generation, cars, cooking, heating, etc.
Before Natural gas is put into use, it must undergo series of processing to rid the gas of impurities. These impurities may include water, sulfur dioxide, and hydrocarbons in liquid state. The degree of processing required for Non-associated gas is different from that required for associated gas.
This article will only cover the compression facility for a Non-Associated gas, most of the connected ancillaries will be explained in further sections of this article.
Natural Gas is a naturally occurring hydrocarbon gas that consists mainly of methane and other higher alkanes. A small percentage of carbon dioxide, hydrogen sulfide, etc. may co-exist with these alkanes which may include ethane, propane, and butane.
Natural Gas is formed when plants and animals (organic materials) buried deep in the earth’s crust are exposed to intense heat and pressure for a long period.
Natural gas is extracted from wells containing only gas or containing liquid (hydrocarbon and water) and gas. Natural gas may be classified either as associated or non-associated depending on the mode of existence.
This is natural gas existing in hydrocarbon reservoir along with crude oil. The gas may be dissolved in the oil or exist as a free gas cap above the oil. The gas dissolved in the oil can only be extracted from the processing of crude oil.
This is also referred to as dry gas or free gas. In some wells, they may co-exist with little quantity of crude oil or condensate.
It should be noted that a large volume of the gas is not dissolved in the liquid but there is usually entrained liquid (Condensate or water) in the gas, therefore, the gas must undergo processing to remove the entrained liquid. The condensate Gas Ratio (CGR) and the Water Gas Ratio (WGR) vary depending on the well composition. Natural gas processing is done by separating all the undesired components from the gas.

Figure 1: Overview of a Compression Facility
In this section, the equipment installed in a typical gas compression facility will be explained. The components described in this section may not be found in all compression facilities, also the quantity of the equipment may vary depending on the project. The major types of equipment installed in a gas compression facility are inlet separator, compressor suction scrubber, compressor, compressor driver, heat exchanger and a discharge scrubber (optional). There are other equipment’s connected to those listed above which will be explained in this article. The selection of the type and size of equipment is a rigorous task performed by a joint team of engineers made up of process, mechanical, electrical, and instrumentation engineers.
It should be noted that some of the recommendations in this article are company-specific and may not be applicable to other companies, however, they can be used as general guidelines.
Natural gas obtained from well is usually in commingled phase vapour and liquid, therefore, it is necessary to separate the gaseous components from the liquid. To achieve this a separator is used in combination with a scrubber, it should be noted that the initial separation process may be more than one stage depending on the fluid composition and the level of separation desired.
The separator is the primary process equipment in a gas compression train, it separates the components of the fluid (well stream) into liquid and gas component, however, the separated gas may contain entrained gases therefore a scrubber should be installed downstream of the separator.
As defined in section 2.6 of API 12J, A separator is a vessel used in the field to remove well stream liquid(s) from gas components that may be either two-phase which removes the total liquid from the gas or three-phase which also remove free water from the hydrocarbon liquid.
Some of the reasons why separation is necessary are stated below
Separators are usually classified based on physical appearance in the field. They are categorized as horizontal or vertical separators. Separators may also be classified as two or three-phase separators. A vertical or horizontal vessel can be used as a two or three-phase separator.
The horizontal separators are physically identified by their obvious length in the horizontal direction i.e. the axis of the cylinder is horizontal. They are more suitable for processing gas feed with high liquid content; they are more efficient in handling three-phase separation. In addition, they are more efficient in handling foaming crude oil.
Horizontal separators are rarely used in NAG (Non-associated gas) compression facilities.

Figure 2: Horizontal Separators
Vertical separators are easily identified in the field by the cylindrical axis been vertical. They are mostly used in processing facilities were more gas is produced compared to liquid. Most vertical separators can handle production containing sand and other sediments without fouling. When there is little space available, they have a comparative advantage because they occupy less plot area. Vertical separators are the most applicable in a gas compression train.
The components of a two-phase separator are the same as a scrubber except for vessel internals which may differ to obtain higher liquid droplets removal. Below is a short description of the components of a typical pressure vessel (separator)
“Vessel body” as used in this context is the combination of the vessel shell and the heads.
The vessel body is the pressure-containing element of the separator. Separators are usually cylindrical with varying types of head. Head types used in gas compression trains are usually hemispherical, ellipsoidal or torispherical, however, this is dependent on the pressure, service, or company requirements. As specified in section 5.11 of DEP 31220031 (Unfired Pressure Vessels), SPDC requires that:
Vessel Heads shall be 2:1 ellipsoidal unless specified by or approved by PRINCIPAL.
Hemispherical heads shall not be used except in high pressure services were specified by or approved by the PRINCIPAL
Torispherical heads shall not be used unless specified by or approved by PRINCIPAL
The nozzles are the connecting point of all piping.
Inlet Feed Nozzle and Connected Piping
The inlet nozzle is usually the largest amongst all process nozzles connected to the separator, its size should be equal to the inlet feed pipe. It is installed at an appropriate height above the liquid level on the shell of vertical separators, on the top or head of a horizontal vessel.
Some of the criteria for feed inlet nozzle/pipe sizing as specified in SPDC DEP 31.22.05.12-Gen section 3.1.1 are:
Momentum Sizing Criteria

Erosional sizing criteria should also be considered in nozzle/pipe sizing.
Gas Outlet Nozzle and Connected piping
The gas outlet nozzle should be located on the shell above the demisting element in a vertical vessel or on the top head.
For separators with vertical inline vane pack mounted perpendicular to the inlet nozzle, the gas outlet nozzle should have its centreline axis coincide with or above the inlet nozzle.
SPDC requires a vertical vessel gas outlet to be fitted in the middle of the top head.
The momentum criteria for sizing gas outlet nozzle/piping as specified in SPDC DEP 31.22.05.12-Gen section 3.1.1 is:
Gas flow Momentum sizing criteria of gas outlet nozzle/piping is:
![]()
Liquid Outlet Nozzle and Connected Piping
Liquid outlet nozzle is installed on the bottom head of vertical vessels, but not in the middle of the head because the drain nozzle is usually installed in the middle of the bottom head.
Some of the criteria for liquid outlet nozzle/pipe sizing as specified in SPDC DEP 31.22.05.12-Gen section 3.1.1 are
Manways
All Separators (pressure vessels) should have at least one manhole or handhole installed. Manhole size and installation should satisfy vessel design code such as ASME Sec. VIII, PD5500, etc.
Other nozzles
There are other nozzles installed on a separator, they include the drain nozzle usually installed at the middle of the bottom head of vertical pressure vessels or the bottom part of the shell of a horizontal vessel.
Other nozzle connections are for level transmitters, pressure transmitters, flare line etc.
Inlet Distributor
The inlet distributor is used to reduce the momentum of the fluid as it enters the separator. It provide primary separation of the liquid from the gas. There are different types of inlet devices the most common types include: half open pipe, perforated or slotted pipe distributors, v-baffles, deflector plate, vane type inlet device, inlet cyclones.
Separators should be equipped with an inlet distributor to aid gas/liquid disengagement, promote separation, minimize splashing, minimize solids plugging, and prevent erosion of the vessel wall. Vane-type inlet devices and inlet cyclones are preferred to other types of devices. ExxonMobil and SPDC gives preference to vane type inlet devices
Gas Phase Internals (Demisters)
The gas phase internals (demister) is used to separate the entrained liquid from the gas. There are various demisting internals used in separators however, the most common is the wire mesh demister and the vane pack demister
Vortex Breaker
As the liquid in the separator flows out, it will swirl and create a vortex; this will cause some gas to be entrained in the liquid. To mitigate the formation of vortex, a vortex breaker should be installed in the liquid outlet of a separator (pressure vessel)
The separation process may be broken down into various sections as described below
The fluid (a mixture of gas and liquid) flows into the separator with a high velocity, the flow is usually turbulent. The primary separation is achieved by impacting the fluid on an inlet distributor device which changes the fluid flow direction. The inlet distributor absorbs the fluid momentum, as the collision continues most of the gas escapes from the well stream (fluid) while the liquid drops down to the separator base.
Note there are other types of inlet device including half open pipe, perforated or slotted pipe distributors, v-baffles, deflector plate, vane type inlet devices, inlet cyclones
As the gas and entrained liquid enter the large area of the separator, its velocity drops. As the liquid and gas are flowing at a reduced velocity, further separation is achieved in the gravity settling zone. The separator should be sized such that the residence time is sufficient for the gas vapor to escape from the liquid and further into the gravity settling zone. The size of liquid particles exiting the gravity settling zone should not exceed 200 microns because they can overload the coalescing section installed before the gas outlet nozzle. The forces acting on the fluid in the gravity settling zone are the gravity force pulling the droplets downward and the force generated as a result of the forward velocity of the fluid. The velocity force either lifts the droplet upward or horizontally however when both gravitational force and the velocity force balances out the liquid droplet will remain suspended. The velocity at which this occurs is termed the critical velocity. The critical velocity is used for sizing the gravity settling zone.

Figure 3: Separator Showing Different Separation Zones
The gas escaping from the gravity settling zone contains entrained liquid. The sizes of the liquid may be up to 200 microns, the entrained liquid can be efficiently removed in the coalescing section.
The coalescing element is installed close to the gas outlet nozzle. The coalescing element can be wire mesh or vane packs, however, wire mesh is mostly used and less expensive. As the gas flows through the wire mesh or vanes, it makes a series of directional changes. The liquid having a greater mass than the gas cannot follow the sudden change in direction. The liquid droplets strike and collect on the wire mesh or vanes. As the liquid droplets coalesce, they fall back into the liquid.

Figure 4: Vane Packs
The scrubber recovers carryover liquid from the separator. The liquid loading level is much lower compared to that of inlet separators. Scrubbers are two-phase separators, mostly vertical however, there are horizontal scrubbers.
As defined in API 12J section 2.5, Scrubber is a type of separator that has been designed to handle flow streams with unusually high gas-to-liquid ratios, commonly used in conjunction with dehydrators, extraction plants, instruments, or compressors for protection from entrained liquids.
The suction scrubber is installed upstream of the compressor because the entrained liquid in the gas can damage the compressor and render it ineffective.
The suction scrubber has the same physical appearance as the inlet separator; the mode of operation is also the same. The only differences that may exist between the scrubber and the inlet separator are:

Figure 5: Gas Scrubber
This is the most critical equipment in a compression train; it is the only rotating equipment in the gas compression train. As the gas flows through the separator, scrubber, and piping network, there is a pressure drop. The fluid pressure is mostly insufficient to transport the gas to other processing facilities such as liquefaction facilities, gas export facilities. It is therefore, necessary to increase the gas pressure; this is achieved by installing a compressor to boost the gas pressure
A compressor is a device used to increase the pressure of the gas by reducing the gas volume.
In a typical gas compression train, the compressor may be staged, (single stage, two stage, etc.)
Compressors with more than one stage, after each stage compression, the compressed gas is passed through a heat exchanger and scrubber to reduce the outlet gas temperature and any liquid droplet before the next stage of compression.
Designing the compressor is a task that should be performed by an expert, various process data including suction pressure range, suction temperature range, gas volumes are used in the design of the compressors. The outlet pressure of the compressor must meet the required pressure to transport the gas to its destination.

Figure 6: Single Stage Turbine Driven Compressor

Figure 7: Three-Stage Gas Compressor
Compressors are not self-driven; a prime mover externally drives them. There are various prime movers including
Of all the above the gas turbine is the most applicable and most efficient. The turbine is connected to the compressor via a shaft properly aligned. The rotation of the turbines causes the compressor rotation, which performs the gas compression. The turbine utilises natural gas as fuel, the gas s pre-treated to the desired quality as specified by the turbine OEM (Original Equipment Manufacturer). The fuel gas temperature range specified by the OEM must be adhered to. The desired temperature is achieved by installing a Preheaters, superheater, and heat tracing elements depending on the requirements. Heaters will be further explained in subsequent sections.
The heat exchanger is used to reduce the temperature of the gas to the desired temperature. Compressed gas temperature can sometimes be higher than 100oC, this temperature is too high and must be reduced. Temperature affects pipe material selection as well as piping material class. ASME B16.5 and other codes specify the temperature range for various material classes however; some Companies require lower temperature for the code defined pipe classes. It is necessary to reduce the discharged gas temperature that may eventually lead to a lower pipe class and lesser material cost.
To achieve the temperature reduction a heat exchanger is used. There are different types of heat exchanger including air-cooled heat exchanger, plate type heat exchanger, shell and tube heat exchanger,
Below is a short description of an air-cooled heat exchanger.
This type of heat exchanger is mostly used for heavy-duty gas compression facilities. It is also used where there is water shortage or where there is limited access to clean water.
The air-cooled heat exchanger also referred to as air cooler transfers the heat from the compressed gas flowing through the conducting tubes to the ambient air.
Ambient air is forced to flow vertically across the horizontal tubes, the airflow is generated by the fans installed below or above the tubes.
Air has poor thermal performance therefore to improve its efficiency, the tubes are provided with external fins.
When the fans are installed below the tube section the air cooler is referred to forced draft air-cooled heat exchanger but when the fans are installed above the tube section it is referred to as induced draft heat exchanger.
The most popular is the forced draft some of the advantages and disadvantages of the type of air coolers are:
Advantages of Forced Draft Air Cooled Heat Exchanger
Disadvantages of Forced Draft Air Cooled Heat Exchanger
Advantages of Induced Draft Air Cooled Heat Exchanger
Disadvantages of Induced Draft Air Cooled Heat Exchanger
An induced draft air-cooled heat exchanger is recommended when control of process temperature is desired and hot air recirculation is to be minimised. For other applications that do not require strict control of process temperature and recirculation, force draft air-cooled heat exchanger can be used.

Figure 8: Forced Draft Air Cooled Heat Exchanger
The discharge scrubber is similar to the suction scrubber in terms of operation. This static equipment may be installed downstream of the heat exchanger when there is a tendency of liquid droplets formation after the gas has been cooled. It is not mandatory to install this equipment however; process engineering must validate this decision.
The discharge scrubber is usually the smallest of all the “separators”.
Depending on the process requirement, fluid composition, facility location, piping material may be of carbon steel, stainless steel or duplex stainless steel. Sometimes the carbon steel pipes used may be lined with corrosion-resistant alloy.
Material selection is critical to prevent catastrophic failure of the piping system. Material selection should take into consideration environmental conditions and the process fluid composition.
When there is a possibility of internal corrosion resulting from the presence of hydrogen sulfide and carbon dioxide in the fluid, stainless steel and duplex stainless pipes are preferred to carbon steel pipes.
When there is a tendency of external corrosion in the form of crevice corrosion, chloride stress corrosion cracking, atmospheric corrosion, the selection of stainless steel, duplex stainless steel piping material in combination with external painting is recommended.
Below is a summary of some major piping connections in a gas compression facility.
Typical gas compression facility with more than one source well, the feed inlet piping originates from the inlet manifold and connects to the inlet nozzle of the separator. The inlet piping is usually the largest of all piping connected to the separator. The inlet nozzle is appropriately located on the pressure vessel shell above the highest liquid level expected in the vessel.
The inlet piping should be sized for two-phase flow (gas-liquid) as determined by the process engineer. The sizing should be performed taking into consideration the pressure drop, erosional velocity, and flow velocity. See section 3.1.2.2 for more details.
The separator gas outlet piping conveys gas with little entrained liquid from the Separator to the compressor suction scrubber. This piping should be sized for single-phase flow since the liquid entrained in the gas is minimal. The piping is connected to the gas outlet nozzle which should be appropriately located depending on the pressure vessel configuration.
This is the piping connection to the condensate outlet nozzle. In vertical vessels, it may be located on the bottom head but not in the middle of the head. The nozzle connection is usually fitted with a vortex breaker to prevent gas from been entrained in the liquid. The condensate piping conveys the condensate to the storage tank or flash drum.
The Scrubber Inlet piping is the discharge from the separator gas outlet. The gas outlet piping of the scrubber may be of the same size as the inlet piping. The piping configuration is the same as described for the separator piping
The suction line piping should be connected to the compressor suction nozzle. This piping should be routed taking into consideration piping flexibility. The maximum piping loads should not exceed the allowable compressor nozzle loads as specified by the compressor vendor.
The compressor discharge piping should be connected to the discharge nozzle of the compressor; it should be properly routed with piping flexibility taken into consideration. The discharge temperature is usually very high, therefore the entire compressor discharge piping should be insulated/lagged to protect site personnel from coming into contact with the hot surface. The discharge piping is connected to the heat exchanger where the discharged gas is cooled to a designated temperature.
The condensate storage tank is a very important component of a gas compression facility. The condensate from all the pressure vessels is routed to the storage tank for onward transportation or evacuation. The condensate tank sizing should be done taking into consideration the condensate production rate from the wells.
Condensate storage tanks are mostly made of carbon steel plates
A relief valve is a device installed on any vessel (separator, heat exchanger), piping to protect the equipment from excess pressure. Every pressure vessel in a compression train must have at least one relief valve. Relief valves have a set pressure, once the vessel pressure set pressure is reached, the valve automatically open to relieve the excess pressure and automatically close when the pressure is slightly below the set point. The relief line is connected to the pressure relief valve.

Figure 9: Pressure Relief Valves
The flare lines (High Pressure or Low Pressure) are very critical safety components of a gas compression facility. They are connected to the relief valves on all equipment and piping. They are usually at a higher elevation than all connected equipment and piping i.e. all the relief lines from each equipment are tied to relief header installed at a higher elevation. All pressure vessels and compressors have at least one pressure relief valve that is connected to the flare line. All flare lines are piped to the vent stack or flare stack. Typical flare line piping is mostly made of carbon steel. All the relief lines are piped to the HP Flare line while all low-pressure depressurization is piped to the LP flare line.
A level controlled valve should be installed on the liquid outlet line (Condensate) line. This is the valve that works with the level instrument installed on the pressure vessel. When the Level instrument on the vessel senses a high volume of liquid it triggers the level control valve to open, and automatically close when the level instrument sense low volume of liquid in the vessel.
The pressure control valves are safety-critical elements of a gas compression facility. As the name implies they are installed to control the pressure in the system. They also work with the emergency shutdown system to shutdown any section of the system with pressure higher than a particular set point. The pressure control valve can be of globe valve, ball valve or butterfly valve with a controller integrated into the valve.

Figure 10: Pressure Control Valve
The anti-surge control system is a control valve with necessary instrumentation located on a bypass line downstream of the compressor for flow recirculation to the suction line to prevent surge from occurring during compressor operation. The anti-surge system uses a control valve, measurement instruments (pressure, temperature, flow), anti-surge controller to determine the flow at which surge will occur. The bypass line on which the valve is installed should originate from downstream the heat exchanger and tie into the compressor suction scrubber inlet. The anti-surge valve is a fast opening valve with the ability to implement a control function in less than 2 seconds.
It is ideal to measure the quantity of gas entering the compressor and the gas delivered by the compressor, it is therefore, necessary to install a flowmeter upstream and downstream of the compressor. The flowmeter installed downstream of the compressor should be downstream of the discharge scrubber. Orifice flow meters are mostly used for this purpose.
In addition, the quantity of condensate generated by the inlet separator should be measured; this is achieved either by installing a Coriolis meter or any other appropriate meter.

Figure 11: Coriolis Meter
The compressor seal and separation gas system is used to prevent the escape of natural gas from the axis of the compressor and deprive the air outside from entering into the compressor. The seal gas pressure should be higher than the maximum pressure the compressor seal will ever experience during operation, a typical compressor seal gas and separation system is divided into three parts:
The seal gas should be clean, dry and compatible with the process gas, while the separation gas is dry inert gas usually nitrogen. In typical compression system, the seal gas may be taken from the compressor discharge header downstream of the discharge scrubber. Filters and dryers may be part of the seal gas control panel to achieve the desired gas quality.
The seal gas vent system is tied to a flare or vent system usually the LP flare header.
Seal gas from the compressed gas header flows into the seal gas control panel where the gas is filtered, dried, and appropriately regulated before it flows into the compressor seal unit.
The separation gas (nitrogen) also flows into the seal gas control unit where it is dried and filtered, the flow is regulated before it enters into the seal gas system.
During project execution the seal gas system is part of the compressor vendor’s package, the engineer’s responsibility is to supply dry clean seal gas to the package.
The Turbine drives the compressor; the turbine utilizes natural gas as fuel. The fuel gas system is a combination of fuel heaters, gas chromatograph, and interconnecting piping. The Turbine OEM usually specifies the fuel gas requirement.
Below are the components of a fuel gas system.
The gas scrubber is installed in the fuel gas line to remove entrained liquid. They function the same way as the compressor suction scrubbers.
Gas turbines are very sensitive mechanical equipment especially to solid particles and liquid droplets. It is therefore necessary to install a filter coalescer to remove small particle size solid and entrained liquid. Filters have the capacity to remove particle size up to 1 micron.
Coalescer filters are equipped with internal baffles and coalescing cartridge.
The Filter serves a second stage filtration for the gas to remove solid and entrained liquid.

Figure 12: Fuel Gas Filter Coalescer
The heaters are used to preheat the fuel gas to the desired temperature. In some cases, the heating system is a combination of preheaters and superheaters to raise the temperature of the fuel gas to the OEM specified temperature. The heaters may be electrically powered with thyristor control for temperature regulation. For systems with preheaters, the gas from the fuel gas manifold flows into the preheater were the gas temperature is raised to a set temperature of about 40oC. From the preheater, the gas flows through scrubber before entering the filter coalescer were the last filtration occurs. As the gas exit the filter, it enters the superheater, which raises the temperature to the desired temperature of about 60oC. The gas at this set temperature is further transported to the turbine.
Note there are other types of heaters including water bath heaters.

Figure 13: Fuel Gas Superheater
The fuel gas piping should be made of a material that does not introduce impurities into the gas through corrosion. Most fuel gas piping is made of stainless steel or duplex stainless steel.
Depending on the location of the turbine, the fuel gas piping should be insulated or heat traced to prevent loss of heat as the gas travels to the turbine generator.
The gas chromatograph is used to determine the constituent and quality of the fuel gas and validate that it is in accordance with the required gas composition. The chromatograph unit takes its suction from the fuel gas line and separates the gas into the various components and displays the composition in field or transmit to a control room.
The instrument air is used for valve operation and other pneumatic systems in the facility.
The instrument air is made up of air compressors that take in atmospheric air, filters the air, and sends it into air receiver (Pressure vessel) for storage. The compressor automatically starts when the pressure in the air receiver drops below a set value and shutdown when the pressure reaches a high a set point. The instrument air header originates from the air receiver, it is routed to all location air is needed. Smaller air bottles may be installed close to designated equipment to provide a buffer for the main utility air system.

Figure 14: Air Compressor
The air compressor generates the utility air; it is usually at a lower pressure compared to the instrument air pressure. The air is sent into a utility air receiver where the air is stored. The utility air is used for cleaning and other utility works in the facility. The utility air piping runs to all equipment especially the compressor.
The water is used for washing of equipment and other utility activities. The utility water should be free of pollutants that can cause corrosion to equipment. The clean water is stored in a tank and piped to all equipment installed in the facility. Clean water piping can be made of galvanized steel, PE, or stainless steel.
The methanol injection package may be installed in some gas compression facilities. It is installed when there is a tendency of hydrate formation in any piping including flare lines. The methanol system is made up of a storage tank/vessel, pump that meters a designated amount of methanol into the piping to prevent hydrate formation.
Nitrogen is an inert gas that can be used to displaced natural gas from piping or equipment. It is used for purging and for the compressor seal gas system.
The Firewater system is made up of jockey pumps, main firewater pumps, firewater ring main, firewater monitors and hydrants.
The ring is installed around the entire facility with monitors and hydrants strategically located.
API 12J: Specification for Oil and Gas Separators
DEP DEP 31.22.00.31-Gen: Unfired pressure vessels
DEP 31.22.05.12-Gen: GAS/LIQUID, LIQUID/LIQUID AND GAS/LIQUID/LIQUID SEPARATORS – TYPE SELECTION AND DESIGN RULES
ASME SEC. VIII. DIV I: Rules for Construction of Pressure Vessels
Hydrogen Fuel Overview: Despite most of us seeing fuel cells as the future, the basic principles are not new. Hydrogen (H2) and energy have a long shared history – powering the first internal combustion engines over 200 years ago to becoming an integral part of the modern refining industry [1].
When Henry Cavendish first isolated and characterized hydrogen in 1766 he called it inflammable air. Years later, Antoine-Laurent Lavoisier named it hydrogen and began a new programme of research on the decomposition (as well as the synthesis) of water. At that time, he was providing additional and decisive proof that water was a compound composed of hydrogen and oxygen in fixed proportions by weight, and he was investigating the possibility of a new source of inflammable air for ballooning.
It was right after these experiments that a gas was produced in large-scale for the first time when hydrogen-filled balloons were used for military purposes during the French Revolution [2]. The most common process used to produce hydrogen at that time was the iron contact process where steam was passed over red-hot iron. Even after World War I, when hydrogen was being used in large quantities in the recently developed Haber process and the hydrogenation of oils, its use as a fluid to inflate balloons and airships remained the main industrial use of this gas.
In 1839, British physicist William Grove suggested that if electricity could split water into hydrogen and oxygen, it should also work in reverse – combining hydrogen and oxygen should give electricity – and he built the world’s first fuel cell to prove it. At the University of Cambridge, UK, in the 1940s and 1950s, Thomas Bacon resurrected and refined the technology that had changed little since Grove’s work. Bacon successfully developed a 3kW fuel cell powered by hydrogen and oxygen and, eventually, an improved version of this cell was used to power NASA’s Apollo space vehicles [3].
But NASA was also working to develop fuel cell technology of its own. The proton exchange membrane (PEM) fuel cell was used during the Gemini space project and it is mainly this technology or a variation of it, that is being put into cars today. The main difference between PEM and alkali fuel cells is that PEM cells can use air directly, whereas its predecessors had to use pure – or nearly pure – oxygen.
In today’s fuel cells, as in Grove’s ’gas battery’, hydrogen and oxygen can be combined to form water and give electrical energy, but over the years the technology has changed somewhat.
Approximately 50 million metric tons of hydrogen are produced globally each year [4]. Hydrogen is an energy carrier that can be used to store, move, and deliver energy produced from other sources. It can be used for power generation in places where it is difficult to use electricity or as a CO2 neutral feedstock for chemical processes — e.g. ammonia-fertilizers. Hydrogen can fuel cars, power trucks, and ships and be a key raw material for refineries, chemical plants, and steel mills — sectors where it is proving difficult to meaningfully reduce CO2 emissions.
Today, we primarily use hydrogen for oil refining and ammonia production, but there is a growing demand for it in steel manufacturing and transportation to power vehicles, upgrade biofuels, and even produce synthetic fuels that may use carbon dioxide as a feedstock. The provision of back-up power and off-grid electricity is today often still dominated by diesel generators. Hydrogen fuel cells represent a possible alternative, in many cases reducing local air pollution as well as the need for imported diesel in non-oil-producing countries [1].
These multiple uses can be grouped into two large categories:
Hydrogen’s role in the decarbonization process can be summarized as shown in the graph below:

Source: https://hydrogeneurope.eu/hydrogen-applications
In the energy field, most hydrogen is used through Fuel Cells (FCs). A fuel cell is an electrochemical device that combines hydrogen and oxygen to produce electricity, with water and heat as by-products. In its simplest form, a single fuel cell consists of two electrodes – an anode and a cathode – with an electrolyte between them [5].
Hydrogen is the most abundant element on earth but it rarely exists alone, therefore it is produced by extracting it from its compound. It can be produced in numerous ways, some methods produce CO2 while others are carbon-free.
Hydrogen is also the lightest gas we know, but under high pressure, it does have a high energy density of 120 megajoules (MJ) per kg. That is almost three times as much as natural gas (45 MJ per kg). Pressurising — compressing — hydrogen gas, however, also requires the necessary energy (about 10%) [6].
Thermal processes
Hydrogen can be extracted from a variety of sources, such as natural gas, nuclear power, biomass, and from the water with the aid of electricity. Natural gas, via steam methane reforming (SMR), is currently the primary source of hydrogen production, accounting for around three-quarters of the annual global dedicated hydrogen production [1], and up to 95% in the United States [1]. SMR is a mature production process in which high-temperature steam (700°C–1,000°C) is used to produce hydrogen from a methane source, such as natural gas.
Firstly, methane reacts with steam under pressure in the presence of a catalyst to produce hydrogen, carbon monoxide, and a relatively small amount of carbon dioxide. This step is endothermic—that is, heat must be supplied to the process for the reaction to proceed. Subsequently, the carbon monoxide and steam are reacted using a catalyst to produce carbon dioxide and more hydrogen. In a final step, carbon dioxide and other impurities are removed from the gas stream, leaving essentially pure hydrogen.
Step 1. Steam-methane reforming reaction
CH4 + H2O (+ heat) → CO + 3H2
Step 2. Water-gas shift reaction
CO + H2O → CO2 + H2 (+ small amount of heat)
Steam reforming can also be used to produce hydrogen from other fuels, such as ethanol, propane, biofuels, gasified coal, or even gasoline. Reforming low-cost natural gas can provide hydrogen today for fuel cell electric vehicles (FCEVs) as well as other applications. Over the long term, experts expect that hydrogen production from natural gas will be augmented with production from renewable, nuclear, coal (with carbon capture and storage), and other low-carbon energy resources [7].
Electrolytic processes
Electrolysis is the process of using electricity to split water into hydrogen and oxygen and is a promising option for hydrogen production from renewable resources. To date, only small amounts of hydrogen have been generated from renewable energies, although that amount is set to increase in the future.
Like fuel cells, electrolysers consist of an anode and a cathode separated by an electrolyte. Their specific functioning depends on the different types of electrolyte material involved: in a polymer electrolyte membrane (PEM) the electrolyte is a solid speciality plastic material, alkaline electrolysers use a liquid alkaline solution of sodium or potassium hydroxide, solid oxide electrolysers use a solid ceramic material [8].
Hydrogen produced via electrolysis can result in zero greenhouse gas emissions, depending on the source of the electricity used.
The colours of hydrogen act as useful markers for telling us how the gas was produced and hence, allow us to evaluate their downsides compared to the advantages the final product can provide.
Grey hydrogen is produced industrially from natural gas generating significant carbon emissions. This is, by far, the dominant type of hydrogen up to date, over 70% of the world’s H2 is grey.
Brown hydrogen and black hydrogen are variants of the aforementioned, the first comes from brown coal, also known as Lignite, while the latter is produced from black coal [9]. The ‘gamification’ of coal creates a synthesis gas (syngas), which is then cleaned in conventional ways to recover the hydrogen but that then leaves a considerable volume of greenhouse gases to deal with. These types constitute around 30% of the current hydrogen production.
Blue hydrogen – or low carbon hydrogen – is a cleaner version, for which 80-90% of the carbon emissions are captured and stored, or reused. This is also called CCS Carbon – Capture & Storage – and only happens in empty gas fields under the North Sea on a large scale.
Green hydrogen is obtained from renewable energy. It avoids carbon emissions in the first place and has the potential to help with the variable output from renewables, like solar photovoltaics (PV) and wind, whose availability is not always well-matched with demand.
Turquoise hydrogen is produced from natural gas using the so-called molten metal pyrolysis technology. Natural gas is passed through a molten metal that releases hydrogen gas as well as solid carbon. The latter can find a useful application in, for example, car tyres. It must be outsourced that this technology is still in the laboratory phase and it will take at least ten years for the first pilot plant to be realised [6].
As governments develop specific hydrogen strategies, growing industry associations provide further evidence that something truly different is happening with hydrogen. More industry players are recognising hydrogen’s versatility and falling cost, enabling investments in a growing range of sectors. The following figure lists all the drivers and indicators for hydrogen’s growing momentum [10]:

Source: Path to Hydrogen Competitiveness: A Cost Perspective. Hydrogen Council
The future of hydrogen fuel lies with the fuel cell. The following schematic diagram represents the basic components and flows occurring in a typical fuel cell:

Source: https://www.power-technology.com/wp-content/uploads/sites/7/2019/10/shutterstock_389151193.jpg
A fuel cell is similar to a battery in that it generates electricity from electrochemical reactions. The essential difference, however, relates to how energy is provided to the cell. In the case of a battery, both the energy-out and the energy-in take the form of electricity, but in the case of a fuel cell—while the useful energy-out is primarily electricity, the energy-in is provided by fuel, such as hydrogen. A key issue with fuel cells is fuel purity and different fuel cell technologies have different abilities to cope with variable fuel quality [4].
PEM Fuel CellsThe proton exchange membrane (PEM) uses a solid proton exchange membrane as the electrolyte, either side of which is a platinum catalyst. Hydrogen is oxidised by the anode catalyst giving electrons and protons that migrate through the membrane to the cathode. Here the protons react with oxygen molecules and the electrons, producing water. The movement of electrons from one side of the fuel cell to the other provides the current that can be used to drive a car, i.e. a Fuel Cell Electric Vehicle (FCEV).
Today, PEM fuel cells operate at around 55 per cent efficiency, compared to an average of around 18-20 per cent for a conventional internal combustion engine. The cells are also able to vary their output quickly, and so are suited for transport applications where quick start-up and high power are needed [3].
One of the problems with membrane-based fuel cells is that they need to run at relatively low temperatures (<80°C) to prevent dehydration, thus lowering the efficiency of the catalysts. Moreover, the two platinum catalysts are pricey and that’s where a lot of current research is focused. One of the approaches used to reduce platinum cost in fuel cells is making core-shell catalysts, with the expensive platinum coating a cheaper nanoparticle made of earth-abundant transition metals (Fe, Co, Ni, and Cu) with low cost and good catalytic performance [11].
Phosphoric acid fuel cells are based on phosphoric acid as an electrolyte and are used today as stationary power generators with outputs in the 100–400 kW range. In addition to electricity, they also produce heat at around 180°C, with potential uses for space and water heating.
Molten carbonate fuel cells (MCFCs) and solid oxide fuel cells (SOFCs) operate at higher temperatures, 600°C and 800–1 000°C respectively [1]. MCFCs are used in the MW scale for power generation (due to their low power density, resulting in a relatively large size). The produced heat can be used for heating or cooling purposes in buildings and industrial applications. SOFCs have similar application areas, often at a smaller scale in the kW range, such as micro-cogeneration units or for off-grid power supply.
Innovators at NASA’s Glenn Research Center have developed a novel SOFC with five times the specific power density of currently available SOFCs. It consists of a bi-electrode supported cell (BSC) manufactured with an innovative ceramic fabrication method that replaces commonly used metal interconnects (such as steel or platinum) with ceramic interconnects [12].
Fuel cells and battery-powered vehicles (BEVs) — a.k.a. electric vehicles — are working towards the same aim, and are complementary. Some suggest a portfolio approach: batteries, with their limited range and long recharge time, are best suited to small cars and short trips, with fuel cell vehicles for long drives and larger cars [13].
Nonetheless, many specialists think at the moment, looking at the technical and economic analysis, that electric vehicles are the most promising option to decarbonise transport in the short-term. This may be due to the overall efficiency process from the electricity generation to the use of the car being better in BEVs than for the multiple conversion processes of FCEVs. Moreover, the cost of hydrogen refuelling infrastructure per vehicle is initially three to four times higher than for BEVs.
In favour of FCEVs, it must be outsourced that their autonomy is much higher — 500+ km; they can be refuelled/refilled much faster — under 5 min; the business model and operation of a hydrogen infrastructure is the same as for a current gas station — this means infrastructure can be built on existing gasoline distribution and retail infrastructure, creating cost advantage, preserving jobs and capital assets; the current value chain and corresponding jobs are safeguarded; a much higher energy density of the hydrogen storage system (compared to batteries), the sensitivity of the FCEV powertrain cost and weight to the amount of energy stored (kWh) is low. This means that as the range, the weight or the volume to be transported grow in importance, the value proposition of FCEV increases. This is specifically important for Heavy-duty vehicles as the increased required amount of hydrogen for these applications is much less than the number of batteries needed as their requirement means that the increased number of batteries in a truck would be linear [14].
If one asks anyone today what the future of cars looks like, they’ll probably answer it’s electric and that Tesla is at the forefront of the movement. But if and when fuel-cell vehicles scale, Tesla and other BEVs will have a tough challenge: they’ll have to increase range while simultaneously decreasing recharging time and price. On the other side, for FCEVs to become the breakthrough that automotive executives believe in, a vast network for hydrogen stations is vital [15].
Most hydrogen on the market today is made from natural gas reforming. Although hydrogen produces no direct emissions of pollutants or greenhouse gases, its production is responsible for CO2 emissions of around 830 million tonnes of carbon dioxide per year, equivalent to the CO2 emissions of the United Kingdom and Indonesia combined [1].
As the world moves to a low-carbon future, hydrogen offers diverse applications as an energy carrier and chemical feedstock and has great potential to support decarbonisation of the world’s energy and industrial sectors. The EU objective of reducing emissions by 80–95% by 2050 compared to 1990 levels, for example, implies almost complete decarbonisation of power generation and high levels of variable renewables (VRE).
Because of this, there is a growing global demand for renewable and low-emissions hydrogen. One pathway for producing green renewable hydrogen is shown below:

Source: Western Australian Renewable Hydrogen Strategy [16]
There is a major concern with hydrogen — where it comes from. Most hydrogen at the moment comes from refining methanol or electrolysis of water, so the power from that should be renewable — otherwise, the emission problem is just being transferred to a different part of the chain. Many argue that hydrogen is the perfect energy storage medium for wind power, with its variable output, producing truly green hydrogen for chemical energy storage.
Achieving a decarbonised electricity supply still faces major economic and technical challenges, in particular in the integration of variable renewable power output. Hydrogen-based fuels are also options for large-scale and long-term energy storage to balance seasonal variations in electricity demand or variable renewable power generation. Also, among the alternative energy sources for the transport sector, hydrogen shows the best performance for the environmental and social bottom line when renewable electricity is employed for hydrogen production [17].
In electricity systems with increasing shares of VRE, surplus electricity may be available at low cost. Producing hydrogen through electrolysis and storing the hydrogen for later use could be one way to take advantage of this surplus electricity. Yet, if surplus electricity is only available on an occasional basis it is unlikely to make sense to rely on it to keep costs down [1].
So, in the long term, with very high VRE shares, there is a need for large-scale and long-term storage for seasonal imbalances or longer periods with no generation. This should be achieved in combination with long-distance trade to take advantage of seasonal differences in global renewable supply.
Hydrogen production via electrolysis is being pursued renewable (wind) and nuclear energy options. These pathways result in virtually zero greenhouse gas and criteria pollutant emissions. However, over the last decade, nuclear units have been shut down prematurely with others currently scheduled for early retirement worldwide, mainly due to lack of market value and socio-political concerns. This is a particularly important trend in the United States, Japan, and Western Europe.
With the rise of more renewables coming onto the grid, many utilities are considering a hybrid or integrated systems approach to improve the economics for baseload energy sources like nuclear reactors [18]. One opportunity is to utilize nuclear thermal heat and electricity to produce hydrogen. Existing nuclear plants could produce high-quality steam at lower costs than natural gas boilers and could be used in many industrial processes, including steam-methane reforming. However, the case for nuclear becomes even more compelling when this high-quality steam is electrolysed and split into pure hydrogen and oxygen.
Solid oxide electrolysers are a good match for atomic energy. They must operate at temperatures high enough for the solid oxide membranes to function properly (about 700°–800°C, compared to PEM electrolysers, which operate at 70°–90°C, and commercial alkaline electrolysers, which operate at 100°–150°C). The solid oxide electrolyser can effectively use heat available at these elevated temperatures (from various sources, including nuclear energy) to decrease the amount of electrical energy needed to produce hydrogen from water [8].
These processes would allow utilities to produce and sell hydrogen regionally as a commodity in addition to providing clean and reliable electricity to the grid. By extending the life of the commercial fleet, it will give the industry time to bring new advanced reactors online. Advanced reactors are expected to operate at considerably higher temperatures and would allow nuclear plants to more efficiently produce hydrogen to dramatically scale-up the industry.
Also, hydrogen-based chemistry could serve as a carbon sink and complement or decarbonize parts of the petrochemical value chain. Today, crude oil (derivatives) are used as feedstock in the production of industrial chemicals, fuels, plastics, and pharmaceutical goods.
If the application of carbon capture and utilization (CCU) technology takes off (as part of a circular economy or an alternative to carbon storage), the technology will need green hydrogen to convert the captured carbon into usable chemicals like methanol, methane, formic acid, or urea. This use of hydrogen would make CCU a viable alternative for other hard-to-decarbonize sectors like cement and steel production [19].
Cleaning the air and improving health is feasible with hydrogen fuel-cell vehicles. Nitrogen and sulphur oxides (NOx, SOx) and particulate matter enter the bloodstream and lungs and are at the root of the cause of many deceases in big urban agglomerations. It is therefore important to tackle one of the main causes of these issues at the city but also rural level: the transport sector [14]
Concerning FCEVs, petroleum use and emissions are lower than for gasoline-powered internal combustion engine vehicles. The only product from an FCEV tailpipe is water vapour but even with the upstream process of producing hydrogen from natural gas, the total greenhouse gas emissions are cut in half and petroleum is reduced over 90% compared to today’s gasoline vehicles [7].
Using hydrogen instead of carbon-containing fuels in energy end-uses could also reduce local air pollution, improving environmental and health outcomes. Urban air pollution concerns and its related health impacts are now major drivers of energy policy decisions, and governments are keenly interested in ways of reducing air pollution and improving air quality. When used in vehicles and heating appliances, hydrogen does not produce particulates or sulphur oxides or raise ground-level ozone. When used in a fuel cell, hydrogen does not produce nitrogen oxides [1].
Hydrogen-powered vehicles can bring significant environmental benefits to transport, society, and the wider energy system. A new study found that if EVs replaced only 25% of combustion-engine cars currently on the road, the United States would save approximately $17 billion annually by avoiding damages from climate change and air pollution. Wind offers the greatest potential health benefits and could save thousands of lives annually [20].
Until now, the cost of producing hydrogen energy has put it out of reach for everyday use. Although renewable hydrogen for transport, industry, and export is a key opportunity for many countries, it will not occur without significant investment and lead times. According to economics, scaling up the hydrogen value chain will be the biggest driver to unlock further cost reductions in the future.
Scaling up manufacturing is a proven way to reduce costs for many hydrogen applications where costs of end-use equipment comprise a large component of Total cost of ownership (TCO) — e.g. fuel cells and tanks in transportation. The scale in manufacturing of equipment would account for up to 70 per cent of this reduction [10]. Around USD 70 billion of investment from various sources will be needed to reach scale, this accounts for less than 5% of annual global energy spend. In transport, the refuelling and distribution networks required and the cost differential for fuel cells and hydrogen tanks compared with low-carbon alternatives imply an additional required investment of USD 30 billion to cover the economic gap.
Governments hold the key to enabling investment. Eighteen countries and several regions and provinces, whose economies account for 70% of global GDP, have developed detailed strategies for deploying hydrogen energy solutions. The Western Australian Government is such an example, it will establish a $10 million Renewable Hydrogen Fund to facilitate private sector investment and leverage financial support to the renewable hydrogen industry [16].
Likewise, the U.S. Department of Energy announced it will provide up to $30 million for cost-shared research and development projects focused on small scale solid oxide fuel cells. The funding seeks to develop advanced technologies which can take the small scale SOFC hybrid systems by using solid oxide electrolyzer cell technologies. Also in the U.S, H2@Scale is a concept from the Department of Energy that explores the potential for wide-scale domestic hydrogen production and utilization to enable resiliency of the power generation and transmission sectors. In 2020 has secured funding for 18 projects that will support the next round of research, development, and demonstration activities under H2@Scale’s multi-year initiative to fully realize hydrogen’s benefits across the economy [21].
As the market grows for hydrogen fuel cell electric vehicles, so does the need for a comprehensive hydrogen fueling infrastructure. Refineries, chemical plants, and steel mills — sectors where it is proving difficult to meaningfully reduce CO2 emissions and thus are future consumers of hydrogen — tend to cluster at major industrial ports, offering an opportunity to build combined infrastructure and thus complementarity in hydrogen solutions. The development of combined solutions can create a virtuous cycle that makes other hydrogen applications viable, reducing the costs of each application.
Cost improvement depends on the scale-up of demand and the associated increase in the utilisation of distribution infrastructure. For example, through an increase in trucking capacity, an increase in size and density of refuelling infrastructure, storage tanks, liquefaction and regasification plants, and conversion and reconversion plants are limiting factors that need to be addressed within the next 5-10 years.
All energy carriers, including fossil fuels, encounter efficiency losses each time they are produced, converted or used. In the case of hydrogen, these losses can accumulate across different steps in the value chain. This makes hydrogen more “expensive” than electricity or the natural gas used to produce it.
Hydrogen-based storage options also suffer from low round-trip efficiency: in the process of converting electricity through electrolysis into hydrogen and then hydrogen back into electricity, around 60% of the original electricity is lost, whereas for a lithium-ion battery the losses of a storage cycle are around 15%. Pumped-hydro storage facilities and batteries offer alternatives, although the latter is unlikely to be used for long-term and large-scale storage [1].
Uncertainty remains about the most effective type of carrier for shipping hydrogen, with much scope for a thorough investigation of the options and improvement of efficiency and capital costs. Liquefaction efficiency, boil-off management, scalability and the efficiency of the cooling cycle require improvement. Publicly funded research efforts might focus primarily on key cost components, such as fuel cell durability and recycling, on-board storage options and electrolyser efficiency.
Around 9 litres of water are needed to produce 1 kgH2 producing 8 kilograms of oxygen as a by-product. If all of today’s dedicated hydrogen production of around 70 MtH2 were to be produced by electrolysis, this would result in water demand of 617 million cubic metres, which would correspond to 1.3% of the water consumption of the global energy sector today [22] or roughly twice the current water consumption for hydrogen from SMR.
Freshwater access can be an issue in water-stressed areas. Using seawater could become an alternative in coastal areas. Using reverse osmosis for desalination requires a manageable electricity demand and its costs have only a minor impact on the total costs of water electrolysis. Direct use of seawater in electrolysis currently leads to corrosive damage and the production of chlorine, but research is looking at how to make it easier to use seawater in electrolysis in the future.
So what of the safety concerns of having a pressurised gas cylinder in the back of your car? Experts believe there are no such issues, but public perception is another thing. For that reason, hydrogen entrepreneurs are trying very hard to convince the public that it is safe. They believe hydrogen is safer than the fuel we currently use to power our cars. Carbon-based fuels tend to spread as liquids. When it burns, conventional fuel produces hot ash, creating radiant heat. This isn’t the case with hydrogen. In its pure form, hydrogen burns no carbon and produces no hot ash and very little radiant heat [23].
Likewise, If hydrogen needs to be shipped overseas, it generally has to be liquefied or transported as ammonia or in liquid organic hydrogen carriers (LOHCs). For distances below 1 500 km, transporting hydrogen as a gas by pipeline is likely to be the cheapest delivery option; above 1 500 km, shipping hydrogen as ammonia or a LOHC is likely to be more cost-effective. These alternatives may also sometimes give rise to safety and public acceptance issues [1].
There is also a lot of work to be done within the framework of ISO/TS 19880-1:2016 standard that recommends the minimum design characteristics for safety and, where appropriate, for the performance of public and non-public fuelling stations that dispense gaseous hydrogen to FCEV.
The technology is working and being pushed by car manufacturers, start-ups, universities, and governments. Supplying hydrogen to industrial users is now a major business around the world. Globally, this industry is dominated by a set of competing for industrial companies comprising: Air Products and Chemicals Inc. (USA), Air Liquide (France), Linde AG (Germany) incorporating BOC Ltd (UK), and Praxair (USA) [4]. Demand for hydrogen continues to rise – almost entirely supplied from fossil fuels, with 6% of global natural gas going to hydrogen production [1]. The world is also looking at how hydrogen can be established as a transport fuel of the future.
Road transport remains a central feature of most hydrogen projects and policies worldwide. Several cities included fuel cell vehicles as part of green transport strategies to promote the use of fuel cell public buses in metropolitan and peri-urban areas of the country. About 4,000 fuel cell electric cars were sold in 2018, growth of almost 56% over the previous year, but this still represents a small fraction compared with the 2018 BEV stock of 5.1 million or the global car stock of more than 1 billion. [1].
Hydrogen fuel cell electric forklifts are already commercially viable as replacements for existing battery electric forklifts and it is estimated that 25,000 forklifts have fuel cells globally. In the case of buses, China has reported the largest deployment, with more than 400 registered by the end of 2018 for demonstration projects. An estimated 50 fuel cell electric buses were also in operation in Europe in 2017, 25 in California and about 30 in other US states. Other demonstration projects have rolled out fuel cell electric buses in Korea and Japan. Volumes are scaling up rapidly and thousands are expected to be in operation by the end of 2020 – mostly in China.
Hydrogen is also combined with CO2 to produce synthetic hydrocarbons such as methane, or synthetic liquid fuels such as methanol, diesel, gasoline, and jet fuel via a process called Fischer-Tropsch [FT] synthesis. FT synthesis is a fully commercial process, the largest coal-to-liquid plant of this kind has operated since the 1980s in Secunda, South Africa [1] [24].
Hydrogen technologies currently have niche status, and there is significant potential for both achieving economies of scale in the manufacturing process and improving the technology further.
The global hydrogen generation market continues to grow driven by increasing demand. It is currently over $100 billion, and it is estimated that it will reach $200 billion by 2025 [4]. It is also noteworthy that Asian countries, such as China and India, have proposed to tighten their sulphur standards for vehicle fuels. This will further drive up hydrogen demand.
On a research-level, teams are looking at all kinds of advanced hydrogen storage. These hydrogen storage efforts include metal-organic frameworks and metal hydride solutions, like sodium alanate or ammonia boranes, but so far none of the proposed solutions works on all the fronts needed for hydrogen storage on a vehicle. Research and pilot projects to introduce hydrogen and ammonia as a fuel for gas turbines and coal power plants are being pursued in Japan, the Netherlands, and Australia.
Fuel cell costs could be further reduced in the future through research-driven advances in technology. It may be possible to increase catalyst activity and thus reduce the platinum content, which is one of the expensive components of the fuel cell. It may also be possible to develop a platinum-free catalyst.
Looking ahead, it seems probable that the long-term potential of hydrogen as a low-CO2 energy carrier will not, by itself, be sufficient to prompt industrial innovations that are not otherwise economically sustainable. The difficulties encountered worldwide in attempts to establish a meaningful price for greenhouse gas emissions suggest that a progressive hydrogen economy might emerge more incrementally from the global hydrogen industry as it already exists today, rather than any disruptive innovation [4].
Hydrogen is an energy carrier that can be used to store massive amounts of energy for grid resilience and security and it is a critical feedstock for most of the chemicals industry. It can, therefore, be considered as an energy vector, a fuel and a raw material. Hydrogen fuel provides a potentially clean alternative to transform electricity into an energy vector for use in transport. Additionally, it can be used as zero-emission mobility in the different transport sectors whilst keeping the infrastructure and value chain in these equations.
Clearly, the proportion of hydrogen coming as green hydrogen from electrolysis using renewable electricity is currently very small, but clean hydrogen is currently enjoying unprecedented political and business momentum, with the number of policies and projects around the world expanding rapidly. Now is the time to scale up technologies and bring down costs to allow hydrogen to become widely used. Government actions and investment in partnerships, seed funding, and fit-for-purpose regulatory support, as well as efficient approval processes, will assist the hydrogen industry to overcome its economic, regulatory and technical challenges.
[1] IEA (2019), The Future of Hydrogen, IEA, Paris https://www.iea.org/reports/the-future-of-hydrogen
[2] Janis Langins. Hydrogen production for ballooning during the French Revolution: An early example of chemical process development, Annals of Science, 1983. 40:6, 531-558, DOI: 10.1080/00033798300200381
[3] https://www.chemistryworld.com/features/fuelling-the-future/3004604.article
[4] Nuttall, William J., and Adetokunboh T. Bakenne. Fossil Fuel Hydrogen: Technical, Economic and Environmental Potential. Springer Nature, 2019.
[5] https://hydrogeneurope.eu/hydrogen-applications
[6] https://www.tno.nl/en/focus-areas/energy-transition/roadmaps/towards-co2-neutral-fuels-and-feedstock/hydrogen-for-a-sustainable-energy-supply/ten-things-you-need-to-know-about-hydrogen/
[7] https://www.energy.gov/eere/fuelcells/hydrogen-production-natural-gas-reforming
[8] https://www.energy.gov/eere/fuelcells/hydrogen-production-electrolysis
[9] https://storymaps.arcgis.com/stories/1eb98332059d493592151ded4d5ada9a
[10] Path to Hydrogen Competitiveness: A Cost Perspective. Hydrogen Council: Brussels, Belgium, 2020.
[11] Ren, Xuefeng & Lv, Qianyuan & Liu, Lifen & Liu, Bike & Wang, Yiran & Liu, Anmin & Wu, Gang. The current progress of Pt and Pt-based electrocatalysts used for fuel cells. Sustainable Energy & Fuels, 2019. 10.1039/C9SE00460B.
[12] https://technology.nasa.gov/patent/LEW-TOPS-120
[13] Coalition-McKinsey, E. U. A portfolio of power-trains for Europe: a fact-based analysis-the role of battery electric vehicles, plug-in hybrids and fuel cell electric vehicles. Brussels, Belgium 2010.
[14] https://hydrogeneurope.eu/zero-emission-mobility
[15] https://www.businessinsider.com/hydrogen-fuel-cell-cars-teslas-biggest-threat-2019-12
[16] http://www.drd.wa.gov.au/Publications/Documents/wa_renewable_hydrogen_strategy.pdf
[17] Hoque, Najmul, et al. “Life cycle sustainability assessment of alternative energy sources for the Western Australian transport sector.” Sustainability in 2020. 12.14: 5565.
[18] https://www.energy.gov/ne/articles/could-hydrogen-help-save-nuclear
[19] https://hydrogeneurope.eu/hydrogen-basics-0
[20] Jacobson MZ, Colella WG, Golden DM. Cleaning the air and improving health with hydrogen fuel-cell vehicles. Science. 2005, 308(5730):1901-1905. DOI: 10.1126/science.1109157.
[21] https://www.energy.gov/eere/fuelcells/h2scale
[22] IEA (2016), World Energy Outlook 2016, IEA, Paris.
[23] https://hydrogeneurope.eu/hydrogen-safety
[24] https://www.sasol.com/sites/sasol/files/content/files/Sasol%2050%20year%20Brochure_1039069422306_0_0_1.pdf
About EPCM

Figure 1: Gender inequality and biases in South Africa in the Architectural Profession (Cullis, 2015). Political and social relations, climate and environmental issues, gender and racial inequality, and the list goes on – all transforming aspects of our country. So is the Architecture Industry. Women’s participation in architecture across the world’s borders has been remarkably varied and has its scars on the face of history to show for it. The nature of this participation depended on time, place, and custom, where women have historically served as patrons, architects, engineers, managers, and muses; acting as key figures on small and large scale construction projects.
When looking at gender inequality and biases, the architectural profession has shown extremely high numbers in the past few years. In 2015, according to the South African Council for the Architectural Profession, 8,842 of the Registered Professionals in South Africa, only twenty-one per cent (21%) accounted for female professionals while 271 Professionals (15%) were of the previously disadvantaged individuals group (Cullis, 2015). This might seem like an insignificant amount of individuals, spread far and wide across South Africa. Still, the reality of this low 21% means only 50 422 912 individuals of 240 109 104 recorded at the time in South Africa, were women (Stats South Africa, 2015). This illustrates the profound racial and gender imbalance in the Architectural Profession in South Africa. In 2016, the situation seemed to take a turn for the better when 36% of newly licensed architects and 42% of new Architect Registration Examination were accounted for as female candidates.
The New York Times published a project called “Overlooked,” which consisted of a series of obituaries for historic female figures who were not recognised for their accomplishments or their share in certain aspects of shaping society at their deaths. Emily Warren Roebling was one such woman. Wife of the 19th-century civil engineer Washington A. Roebling, Emily oversaw the final construction phase of the iconic Brooklyn Bridge after the passing of her husband, Washington A. Roebling. Shortly after this publication, in December 2017, the New York-based Beverly Willis Architecture Foundation (BWAF) celebrated 50 astounding women in American architecture (PRACTICE). Of those listed, Georgia Louise Harris Brown (1918–99) appeared and was celebrated as the second African-American licensed female architect in the United States.

Image 1: Emily Warren Roebling: The Woman Who Saved the Brooklyn Bridge, a Mighty Girl Blog
Although progress is observed within this field and recognition is given where it is long overdue, it is a slow and challenging process to achieve equality within the architecture community and our society. In light of celebrating Women in Architecture and Construction for International Women’s Month, EPCM Architects is highlighting some of the achievements of women in the architectural and construction industry to help rekindle their drive, passion, love and voice in architecture and address the systematic oversight of an entire gender.
Architecture is filled with stereotypes and status quos that are not productive. In a world where we increasingly require a collaborative model of production and building, I often disrupt and reset the framework and mindset to have everyone focus on common goals and vision. I think one needs to speak up and one needs to be decisive and aggressive. — Toshiko Mori, in The Harvard Gazette

Image 2: Tia Kanakakis, MDS Architects
Name: Tia Kanakakis
Practice: MDS Architects
Profession: Architect
In 1990 Tia Kanakakis joined MDS Architecture after obtaining her Master’s Degree in Architecture, cum laude – receiving several awards through the course of her Architectural Studies. In 1994, fulfilling the design and project architect role, she became a partner at MDS Architects. Kanakakis specialises in typologies of retail shopping centres, hotels, casinos and office developments (MDS Architecture: Online). Tia’s drive, passion, work-life balance and interactive management style have equipped her with the tools to build lifelong relationships with her clients while leading her team of professionals on various projects all over South Africa.
Working for 22 years on the refurbishment, alterations, and additions to Sandton City Shopping Centre, Tia has played an integral part in the long-term vision and developmental transformation of Sandton City. Completed in April 2016, Tia’s responsibilities included principal designer and lead architect. Well respected by both her contemporaries and colleagues, Tia effectively heads and manages the management systems and finances of MDS Architects.
Project: Mall of Africa, Gauteng
Completed: April 2016

Image 3: Mall of Africa, Midrand, Gauteng. Bird’s-eye view of the Mall of Africa (MDS Architecture: Online).
Mall of Africa is well-known as the largest single-phase shopping centre built in Southern Africa, functioning as a mixed-use Waterfall City development in Midrand, Gauteng with a total retail area of 130 000 m² – setting a new record in retail design. The design, construction and management of this Architectural feat has promised many awards (MDS Architecture: Online), including:

Image 4: Mall of Africa interior crystal court. (MDS Architecture: Online).

Image 5: Mall of Africa exterior court. (MDS Architecture: Online).
The main design inspiration for the mall’s design (MDS Architecture: Online). And various interior and exterior courts were the natural and geological beauty of the African continent. The four courts depict the different climatic zones in Africa: an oleum court for the oil-rich West Africa, a great lakes court showcasing East Africa, a crystal court celebrating the mineral wealth in South Africa and a sand court depicting the desert area of North Africa. Striking and unique elements of the mall include high shop fronts, wide passages, and a rolling roof feature in the centre, which is equipped with specialist animated LED lighting and a large public space underneath.

Image 6: Ilze Wolff, Wolff Architects
Name: Ilze Wolff
Practice: Wolff Architects
Profession: Architect & Interior Designer
Obtaining her B.Arch and M.Phil in Heritage and Public Culture at the University of Cape Town, Ilze Wolff is now a partner at Wolff Architects and co-founder of Open House Architecture (Wolff Architects: Online). Recently added to the prestigious Women in Architecture Award shortlist, Wolff also has The Moira Gemmill prize on her list of many, highly esteemed awards. The Moira Gemmill prize, named after the late Moira Gemmill, the design director at the Victoria and Albert Museum, recognises brilliantly abled architects under 45. With all these staggering achievements on her mantel, Ilze and her husband Heinrich Wolff are championing intersectional planning in the Architectural and Design industry in their Cape Town-based practice.
Wolff’s design studio and architectural outlook on society and the built environment is concentrated on and developed around an architectural practice of consequence. Utilizing design, advocacy, research, and documentation mediums, Wolff’s highly skilled, committed, and engaging interaction has favoured her in teaching and lecturing internationally. Countries such as Switzerland, Germany, Italy, USA, Canada, Japan and India have come to experience the sharing of knowledge and insights by Wolff and has been included at various international exhibitions: The Venice Architecture Biennale, Shenzhen Biennale of Architecture and Urbanism, Louisiana Museum of Modern Art, the Chicago Architectural Biennale, the Sao Paulo Biennale and the South American Architecture Biennale.
Project: Cheré Botha School – a school for learners with special educational needs
Completed: April 2016

Image 7: View from afar. Cheré Botha School, Western Cape. (Wolff Architects: Online)
Commissioned by the Western Cape Provincial Government, the Cheré Botha School was mindfully designed for learners ages 3-18 on the autism spectrum and with intellectual disabilities.

Image 8: Internal, covered courtyard. Cheré Botha School, Western Cape. (Wolff Architects: Online)
In South Africa, many special educational needs schools are a composition of clustered classrooms looped along a central corridor – mainly due to the vulnerability of these learners to respiratory diseases. Open courtyard typologies become highly inappropriate due to the persistent wind and winter rainfall of Cape Town. The result: no interaction or clustering beyond the classroom. Although both learners with autism and intellectual disabilities are taught in separate classrooms, it is highly encouraged and mutually beneficial for both groups of the learner to play and interact together.
Sculptural volumes, characteristic roof profiles and corrugated iron are the central celebrations of the architectural composition (Wolff Architects: Online). Volumes are clad in corrugated iron and rise like cumulus clouds at their base, while the hall’s interior is triangulated in A-framed spaces – enabling the hall to become an exaggerated version of other surrounding forms. Low glare within the interior of the spaces is ensured by placing openings for the light at carefully arranged positions.

Image 9: Student Hall, Cheré Botha School, Western Cape. (Wolff Architects: Online)
The architecture enhances Fumihiko Maki’s speculations about the nature of collective form. According to Wolff (Wolff Architects: Online), ‘’Fumihiko Maki focuses on the design of authentic urban patterns which respond to the lifestyle, terrain, urban economies and contemporary challenges of societies or urban districts. The character and coherence of villages which developed over long periods served for Maki as a benchmark of significant collective form at an urban scale.’’
Writer, scholar, a Master’s in African Studies at the University of Cape Town, a keen focus on heritage, architectural history and public culture, Ilze Wolff embodies the 21st-century female Architect.

Image 10: Khensani de Klerk, co-director of Matri-Archi(texture) and Architect at Local Studio. (Local Studio: Online)
Name: Khensani de Klerk
Practice: co-director of Matri-Archi(texture) and Architect at Local Studio
Profession: Architect
Khensani de Klerk is an architectural designer, researcher, writer, and founder of the blog Matri-Archi(tecture). The blog is dedicated to discussing gender and racial equality in the design and architecture industry.
Working as an architect for Local Studio, Khensani attempts to apply lessons learned in urban environments to rural communities, which share one common factor: a fair number of people using the same facilities (Local Studio: online). With this approach to architecture, applying principles of public space and place-making is highly relevant in the 21st century, where buildings are subject to natural or city surroundings.
Project: Limpopo Youth Hostel, Droogekloof, Limpopo
Project Type: Education, Housing
Completion Year: 2018-2019

Image 11: A main approach to the new hostel facility and hall. Limpopo Youth Hostel, Droogekloof. (Local Studio: online)
Commissioned by a global non-profit organization, this project was designed with the focus on encouraging training for the youth. The site was originally built to function as a wedding venue, with its accompanying chalets and dining hall (Local Studio: online). The brief to the architects, including de Klerk and the design team of Local Studio, was to build two new hostel blocks to house 120 individuals, create healthy and interactive communal spaces, and extend the existing function hall.

Image 12-1: Hostel bedroom units and communal bathroom. Limpopo Youth Hostel, Droogekloof. (Local Studio: online).

Image 12-2: Library space. Limpopo Youth Hostel, Droogekloof. (Local Studio: online).
The proposed new two hostel buildings are made up of living pods that can house eight students each. These pods have bunk-beds, offering each student privacy through screen walls and subtle lighting elements. Openable windows are installed above each bed for improved ventilation, creating the irregular window pattern on three of the building facades. Communal space at ground floor level is added to each hostel cluster, with one dedicated as a library and the second as an art centre. A material palette with sensitivity to nature and the capacity to age gracefully is poetically combined to celebrate space, education, individuality and interaction (Local Studio: online). A lightweight, primary structure with Hebel concrete blocks is used to construct this hostel complex, with Rhinowood exterior cladding and a local wax-treated South African pine.

Image 13: A material combination of concrete and timber cladding. Limpopo Youth Hostel, Droogekloof. (Local Studio: online).
Dr Jane Hall and Audrey Thomas-Hayes, authors of their new book Breaking Ground: Architecture by Women, acknowledge that the barrier keeping women from front-leading positions in the Built Environment isn’t always all-pervasive.
“For many women working in and around the profession, architecture, as building, is not a central occupation,” they write in their introduction. “The flexibility of non-studio-based working environments and barriers to access in the building industry has meant that women, out of necessity, have been heavily influential in shaping theoretical discourse rather than construction.’’
For us, as 21 Century female architects, to see our legacy succeed and change the face of the Built Environment, we need to advocate a form of architecture that is thoughtful of everyday life and participatory approaches to design – an antidote based on observations of the way we as a society live and interact with one another. Universities, technicians, and even informal knowledge sharing have proven successful in spaces where being and thinking differently are positively embraced and celebrated. Of course, we must acknowledge that a university education is not open to everyone, yet that does not mean there are ways of opening it up or creating opportunities for skills transfer within the industry, especially with the help of new technologies.
Despite resistance, barriers and restrictions, women’s involvement in shaping the built environment has embodied manifold forms. Yet the relatively short history of women as primary architectural designers is shocking, to say the least. Professionalising the female contribution to architecture in many countries in the nineteenth century has seen many women fight to overturn existing limits and be equal contributors to space and place. With this, its attendant professional training and licensing processes created new possibilities and obstacles for women in their fight to act as primary designers of the built world.
Educational barriers aside, women have continued to pressure other longstanding exclusionary mechanisms within their field of architecture and design. Denise Scott Brown, born and educated in South Africa, has lived and worked in the United States since 1958. She has identified cultural barriers as early as the 1970s, dating back to when she spoke to groups of women about her work. With many contributions to architecture, theory, and planning, Brown has built her career on analysing how people experience spaces with both their eyes and body – a provocative juxtaposition between high and low, familiar and unfamiliar, formal and vernacular.
She has spent her long career investigating how. Married and working alongside her husband Robert Venturi since the 1960s, Scott Brown has committed her work to make others aware of cases of gender bias.
Architects, historians, and critics have invested countless hours of energetic work to combat gender discrimination. However, these efforts are ongoing, and it must be noted that light is shed on other overlooked or misunderstood issues in architectural production. It seems more applicable than in the coming years, and inclusive recognition of the creative process and the individuals behind it in making any element of the built environment.
A Mighty Girl blog. Emily Warren Roebling: The Woman Who Saved The Brooklyn Bridge. October 1, 2019. [Online] Available from:
https://www.amightygirl.com/blog?p=25975 [Accessed: 02/09/2020].
Cullis, Jacquie. SACAP Announces Women In Architecture South Africa (WiASA) program. September 2015, 2015. [Online] Available from:
http://www.sacapsa.com/news/249829/SACAP-Announces-Women-In-Architecture-South-Africa-WiASA-programme.htm [Accessed: 15/08/2020].
Local Studio, Practice. Unknown date. [Online] Available from:
https://localstudio.co.za/practice [Accessed: 11/08/2020].
MDS Architects, Mall of Africa. Unknown date. [Online] Available from:
https://www.mdsarch.co.za/listingDetail.php?Mall-of-Africa-17 [Accessed: 11/08/2020].
PRACTICE, Architect Magazine. Celebrating Women in Architecture. Unknown date. [Online] Available from: from: from:whttps://www.architectmagazine.com/practice/celebrating-women-in-architecture_o [Accessed: 15/08/2020].
Stats South Africa. Mid-year population estimates. Statistical release, Pretoria: StatsSA, 2015, 8.
Toshiko Mori, Archinet: The Harvard Gazette. Unknown date. [Online] Available from: https://archinect.com/news/article/150064876/be-persistent-and-then-be-resilient-toshiko-mori-looks-back-on-her-path-to-architecture. [Accessed: 21/08/2020].
Wolff Architects, Projects: Education. Unknown date. [Online] Available from:
https://www.wolffarchitects.co.za/projects/all/special-needs-school/ [Accessed: 21/08/2020].