The Works entail the supply and installation of a Sacrificial Anode Cathodic Protection (SACP) system for the Shemla Pipeliine located near Shemula/Jozini (Kwa-Zulu Natal). The Pipeline links the new Shemula Reservoir with the Existing pipeline.
The total length of the Shemula Pipeline is nominally 15 000 meters. The pipe material is typically SANS 719 Grade B. The Shemula pipeline has been coated with 1.22mm 3LPE coating
Services Provided:
- Provision of permanent SACP system;
- Provision of electrical continuity;
- SACP Quality Control and Quality Assurance (QC/QA)
- SACP Installation check out and Hand-Over.
Client
LR Civils